Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
FACULTATEA DE HIDROTEHNICA
DEPARTAMENTUL DE INGINERIE HIDROTEHNICA
Bd. Lacul Tei 124 * Sector 2 * RO-020396 * Bucuresti - ROMANIA
Tel.: +40-21-242.12.08, Tel./Fax: +40-21-242.07.81, www.utcb.ro
BENEFICIAR FINAL:
BENEFICIAR:
Martie 2016
BENEFICIAR FINAL:
BENEFICIAR:
Decan,
Prof.dr.ing. Ioan Bica
Colectiv elaborare
Prof.dr.ing. Gabriel Racoviteanu Director proiect
Conf.dr.ing. Elena Vulpasu
Sef lucrari dr.ing. Eduard Dinet
Martie 2016
CUPRINS
CUPRINS
Abrevieri ............................................................................................................................................... 4
1
Consideratii teoretice................................................................................................................. 12
3.1
3.1.1
3.1.1.1
3.1.1.2
3.1.1.3
3.1.1.4
3.1.1.5
3.1.1.6
3.1.2
3.2
3.2.1
3.2.2
3.2.2.1
3.2.2.2
3.2.2.3
3.2.2.4
3.2.2.5
4.2
4.3
Bibliografie ......................................................................................................................................... 46
TABELE
Tabel 2.1. Calitatea apei din localitatea Slatina, Statia de pompare Balcescu, 12.11.2015..................... 9
Tabel 2.2. Calitatea apei din localitatea Slatina, Statia de pompare Balcescu (analize efectuate de
ECOIND). ................................................................................................................................................. 10
CUPRINS
Tabel 3.1. Avantaje si dezavantaje ale tehnologiilor de indepartare a azotului amoniacal din apa
destinata potabilizarii. ............................................................................................................................... 22
Tabel 4.1. Parametrii de functionare ai instalatiei ciclul I. .................................................................... 26
Tabel 4.2. Calitatea apei tratate si a apei brute din localitatea Slatina, SP Balcescuciclul experimental
I. ................................................................................................................................................................ 28
Tabel 4.3. Parametrii de functionare ai instalatiei ciclul II. ................................................................... 35
Tabel 4.4. Calitatea apei tratate si a apei brute din localitatea Slatina, SP Balcescu ciclul
experimental II. ......................................................................................................................................... 37
Tabel 5.1. Calitatea apei tratate si a apei brute din localitatea Slatina, SP Balcescuciclul experimental
I. ................................................................................................................................................................ 43
Tabel 5.2. Parametrii recomandati pentru schema de tratare propusa................................................... 44
FIGURI
Figura 1.1. Imagine de ansamblu Statie Pilot de Tratarea Apei, Laborator Alimentari cu Apa U.T.C.B.
.................................................................................................................................................................... 6
Figura 1.2. Statia pilot camera de reactie rapida, camera de reactie lenta. .......................................... 6
Figura 1.3. Statia pilot decantor si filtru rapid de nisip. .......................................................................... 7
Figura 1.4. Statie pilot generator de ozon, coloana post-oxidare, filtre cu carbune activ granular. ...... 8
Figura 3.1. Variatia concentratiei de amoniu, respectiv amoniac in functie de pH. ................................ 16
Figura 3.2. Variatia procentajului de HClO in solutie apoasa la 20 0C. .................................................. 18
Figura 3.3. Reprezentarea grafica a curbei de clorinare a apelor cu continut de azot amoniacal [1]. ... 19
Figura 4.1. Schema tehnologica ciclul experimental I............................................................................. 25
Figura 4.2. Curba clorare apa bruta Slatina, SP Balcescu ciclul experimental I. ................................ 26
Figura 4.3. Sistem injectie hipoclorit de sodiu ciclul I........................................................................... 28
Figura 4.4. Filtru nisip si filtru CAG ciclul I ........................................................................................... 28
Figura 4.5. Concentratii medii pentru Amoniu si Fe - ciclul I. ................................................................. 30
Figura 4.6. Variatia in timp a principalilor indicatori pentru apa filtrata pe nisip - ciclul I. ....................... 31
Figura 4.7. Schema tehnologica ciclul experimental II............................................................................ 33
Figura 4.8. Curba clorare apa filtrata Slatina, SP Balcescu, ciclul experimental II. ................................ 34
Figura 4.9. Sistem injectie permanganat de potasiu si coloana pre-oxidare - ciclul II. .......................... 37
Figura 4.10. Variatia concentratiei de amoniu si de mangan pe schema de tratare ciclul II. .............. 39
Figura 4.11. Variatia in timp a concentratiei de mangan si amoniu din apa filtrata pe nisip si a
concentratiilor de clor din apa post-oxidata cu clor ciclul II. ................................................................. 40
Figura 5.1. Schema de tratare propusa. ................................................................................................. 42
ANEXE
Anexa 1
Anexa 2
Anexa 2
ABREVIERI
Abrevieri
AB
Apa bruta
AFRN
AFCAG
APREOX
Apa Pre-Oxidata
APOX
Apa Post-Oxidata
AT
Apa tratata
CMA
EBCT
FNU
d10
Diametrul ochiurilor sitei prin care trece 10% din materialul cernut
d60
Diametrul ochiurilor sitei prin care trece 60% din materialul cernut
HAP
MON
NTU
O2
Oxigen
O3
Ozon
Debit
SDWA
ST
Statie de Tratare
STAP
Tc
Timp de Contact
TDS
THM
Trihalometani
THMFP
TOC
U.M.
Unitate de masura
CAPITOLUL 1
Descrierea instalatiei pilot
instalatii de dozare reactivi care cuprind pompe dozatoare si bazine de stocare reactivi;
instalatii de dozare clor cu vacuum, care cuprind butelii de clor, pompa de circulatie,
injector si dozatorul propriu-zis;
instalatie de apa spalare filtre constituita din rezervor cu volumul V=300 dm3 si pompa
apa spalare;
sunt prevazute dotari pentru recoltarea probelor atat in fazele finale ale proceselor cat
si in fazele intermediare.
CAPITOLUL 1
Descrierea instalatiei pilot
pentru a nu se denatura calitatea acesteia. Apa procesata pe instalatia pilot a avut o temperatura
medie de 10 - 150C. In anexa 1 este prezentata schema tehnologica a instalatiei pilot.
In figurile urmatoare sunt prezentate fotografii cu obiectele tehnologice din cadrul
instalatiei pilot.
Figura 1.1. Imagine de ansamblu Statie Pilot de Tratarea Apei, Laborator Alimentari cu Apa U.T.C.B.
Figura 1.2. Statia pilot camera de reactie rapida, camera de reactie lenta.
CAPITOLUL 1
Descrierea instalatiei pilot
CAPITOLUL 1
Descrierea instalatiei pilot
Figura 1.4. Statie pilot generator de ozon, coloana post-oxidare, filtre cu carbune activ granular.
CAPITOLUL 2
Calitatea apei brute
pH
Unitati pH
7.7
6.5-9.5
Turbiditate
FNU
11
<5
Conductivitate
S/cm
512
2500
Cloruri
mg/l
19.86
250
Fier
g/l
61.55
200
Mangan
g/l
124
50
Duritate totala
grade de duritate
5.27
min.5
Amoniu
mg/l
2.06
0.5
Azotati
mg/l
0.2209
50
10
Azotiti
mg/l
0.0174
0.5
11
Indice permanganat
mgO2 /l
<LOQ
12
mg/l
<LOQ/0.014
0.1
S-au efectuat 2 analize complete privind calitatea apei brute din cele doua probe furnizate
pentru realizarea studiului de tratabilitate. Rezultatele acestora sunt prezentate in tabelul
urmator.
Analiza rezultatelor a pus in evidenta urmatoarele:
apa a avut un pH de 7.4, in domeniul usor alcalin, iar turbiditatea a fost 0.17 0.36
FNU, sub limita admisa pentru apa potabila (1 NTU valoarea maxim admisa de legea
458/2002 pentru eficienta dezinfectiei);
conductivitatea de 506 - 512 S/cm pune in evidenta o mineralizare medie a apei,
specifica apelor subterane;
duritatea apei a fost relativ redusa, cu valori de 4.58 5.15 grade de duritate;
concentratia de mangan a fost 79.5 g/l in prima zi de teste, respectiv 82.8 g/l, in
ziua a doua, fata de 50 g/l, concentratia maxim admisa pentru apa potabila conform
legii privind calitatea apei potabile;
concentratia de fier a fost 23.8 40.1 g/l fata de 200 g/l, concentratia maxim
admisa pentru apa potabila;
CAPITOLUL 2
Calitatea apei brute
concentratiile de azotati si azotiti pentru cele doua probe analizate au fost reduse,
sub limitele admise pentru apa potabila;
concentratia de amoniu a fost in domeniul 1.63 mg/l 1.7 mg/l fata de 0.5 mg/l,
concentratia maxim admisa pentru apa potabila;
incarcarea organica evaluata prin oxidabilitate si concentratia de carbon organic total
a fost redusa incat se estimeaza ca nu exista riscul de a se forma trihalometani cu
clorul adaugat pentru dezinfectie;
din punct de vedere al continutului de metale grele apa sursei este de buna calitate,
concentratia acestora fiind sub limita admisa pentru apa potabila;
de asemenea concentratia de micropoluanti organici a fost sub limita admisa pentru
apa potabila;
pH
Unitati pH
7.4
7.4
6.5-9.5
Turbiditate
FNU
0.36
0.17
<5
Conductivitate
S/cm
506
512
2500
Duritate totala
Grade
germane
5.15
4.58
min.5
Fier
g/l
40.1
23.8
200
Mangan
g/l
79.5
82.8
50
Sulfat
mg/l
7.75
7.06
250
Cloruri
mg/l
20.18
19.48
250
Sodiu
mg/l
89.1
82.7
200
10
Amoniu
mg/l
1.7
1.63
0.5
11
Azotati
mg/l
0.47
0.51
50
12
Azotiti
mg/l
0.08
0.069
0.5
13
Indice permanganat
mgO2 /l
1.6
1.6
14
Bor
mg/l
0.796
0.076
1.0
15
g/l
<10
<10
100
16
Arsen
g/l
<0.2
<0.2
10
17
Cadmiu
g/l
<0.12
<0.12
18
Crom total
g/l
<0.4
<0.4
50
19
Cupru
mg/l
1.4
1.1
0.1
20
Plumb
g/l
<0.05
<0.05
10
21
Nichel
g/l
<0.4
<0.4
20
22
Seleniu
g/l
<0.1
<0.1
10
10
Indicator
CAPITOLUL 2
Calitatea apei brute
U.M.
Valoare
8.02.2016
9.02.2016
Legea 458/2002 cu
modificarile si
completarile
ulterioare
23
Stibiu
g/l
<0.3
<0.3
5.0
24
Fluoruri
mg/l
0.31
0.29
1.2
25
Mercur
g/l
<0.01
<0.01
26
mg/l
1.24
1.23
Nici o modificare
anormala
27
Aluminiu
g/l
16.7
17.1
200
28
Zinc
g/l
27.7
27.2
5000
-benzo(b)fluoranten
g/l
<0.0006
<0.0006
-benzo(k)fluoranten
g/l
<0.0006
<0.0006
-benzo(ghi)perilen
g/l
<0.0006
<0.0006
-indeno(1,2,3-cd)piren
g/l
<0.0006
<0.0006
30
Pesticide organoclorurate
g/l
<0.001
<0.001
0.1
31
Pesticide triazinice
g/l
<0.008
<0.008
0.1
32
Pesticide organofosforice
g/l
<0.001
<0.001
0.1
Tetracloretena si
g/l
<0.05
<0.05
Tricloretena
g/l
<0.05
<0.05
34
Bromati**
g/l
<0.5
<0.5
10
35
Benzen
g/l
<0.05
<0.05
36
Cianuri totale
g/l
<10
<10
50
37
Cianuri libere**
g/l
<10
<10
38
1,2 Dicloretan
g/l
<0.25
<0.25
39
Epiclorhidrina
g/l
<0.05
<0.05
0.10
40
Clorura de vinil
g/l
<0.05
<0.05
0.50
Hidrocarburi aromatice
policiclice
29
33
0.1
10
11
CAPITOLUL 3
Consideratii teoretice
3 Consideratii teoretice
3.1 Consideratii privind prezenta fierului si manganului in apele
naturale
Fierul si manganul se numara printre metalele cel mai des intalnite in alcatuirea scoartei
terestre si reprezinta elemente importante pentru nutritia oamenilor si animalelor [7].
Aceste elemente sunt solubile in apa in forma lor redusa (ioni bivalenti) si sunt intalnite in
ape subterane, lacuri naturale si lacuri artificiale. In forma redusa ionii de fier si mangan se pot
intalni ca ioni liberi ( Fe2+ si Mn2+ ) in cazul majoritatii apelor subterane, sau legati in combinatii
complexe cu materii organice, in cazul apelor de suprafata sau apelor subterane puternic colorate.
In forma lor oxidata, fierul si manganul sunt insolubile in apa, cum este cazul apelor curgatoare si
lacurilor aerate artificial pentru mentinerea gradului de oxigenare.
Prezenta acestor elemente confera apei culoare, turbiditate si gust metalic. In plus, aceste
elemente favorizeaza dezvoltarea ferobacteriilor si formarea de depuneri in retelele de distributie,
cu efecte negative cum sunt coroziunea conductelor, aparitia de pete la spalarea tesaturilor si
furnizarea la consumator a unei ape cu aspect inestetic.
Analizand efectele prezentate, rezulta ca fierul si manganul pot genera probleme de
acceptabilitate a apei la consumator, crescand importanta acestor elemente in procesul de
selectie a schemelor de tratare [7].
12
CAPITOLUL 3
Consideratii teoretice
Tabelul urmator prezinta recomandari privind utilizarea diversilor agenti oxidanti in functie
de eficienta lor in procesele de demanganizare:
Tabel 3.1 Agenti oxidanti in procesele de demanganizare [1].
Aer
Cl2
ClO2
O3
KMnO4
++
+++
+++
(3.1)
(3.2)
(3.3)
13
CAPITOLUL 3
Consideratii teoretice
(3.4)
Doza teoretica necesara este de 1.3 g Cl2 : 1 g Mn2+, dar in practica dozele utilizate sunt
mult mai mari, pentru asigurarea oxidarii simultane si pentru alti constituenti ai apei (fier,
substante organice, etc).
Procesul de oxidare a manganului cu clor necesita timpi de contact mari (peste o ora in
conditii de pH sub 7). Spre deosebire de fier, care este oxidat rapid de clor, in cazul manganului
este necesara atingerea unui pH de 9 si utilizarea de clor in exces. Astfel, un aspect foarte
important in selectia clorului ca agent oxidant pentru demanganizare este compozitia apei brute,
fiind necesara evaluarea potentialului de formare a subprodusilor de tipul trihalometanilor. Daca
exista risc mare de aparitie a THM se recomanda utilizarea unor agenti oxidanti mai puternici, care
nu produc THM, cum sunt dioxidul de clor sau permanganatul de potasiu.
(3.5)
Doza teoretica necesara este de 2.45 g ClO2 : 1 g Mn2+, insa dioxidul de clor se utilizeaza
destul de rar pentru oxidarea manganului, atingerea eficientei dorite impunand depasirea dozei
stoechiometrice datorita materiilor organice prezente in apa. Prin oxidarea materiilor organice se
reduce dioxidul de clor la ioni clorit (ClO2-), subprodusi nedoriti [1], care prezinta potential risc
toxicologic si imunologic privind oxidarea hematiilor.
(3.6)
Valoarea pH-ului optim pentru oxidare este 8, iar doza teoretica necesara este de 0.9 g O 3
:1 g Mn2+. Este necesara dozarea astfel incat oxidarea sa conduca numai la formarea de dioxid de
mangan.
Supradozarea ozonului conduce la formarea MnO4-, conferind apei tratate culoarea roz [1].
In cazul reactiei manganului cu ozonul rezulta suspensii coloidale ce nu pot fi retinute
direct in treapta de filtrare. Astfel, este esentiala pentru eficienta procesului de demanganizare,
destabilizarea suspensiilor coloidale inainte de treapta de filtrare. Daca ozonul este aplicat la
punctul de intrare in schema de tratare, deci inainte de injectarea agentului de coagulare,
suspensiile sunt destabilizate si se pot retine in treptele de decantare si filtrare. Daca injectarea
ozonului se realizeaza intre treapta de decantare si treapta de filtrare este necesara destabilizarea
particulelor coloidale prin adaugarea unei mici doze suplimentare de coagulant [9].
14
CAPITOLUL 3
Consideratii teoretice
In mod uzual schemele de tratare continand treapta de ozonare si treapta de filtrare pot
produce ape cu un continut total de mangan dizolvat sub 0.03 mg/l [9].
In cazul in care manganul se afla in combinatii cu substante organice si sunt necesare
procese de coagulare-floculare si decantare, pentru evitarea utilizarii unor doze excesive de ozon,
implicand costuri de productie ridicate, se recomanda utilizarea altui agent oxidant inainte de
treapta de decantare, sau ozonarea apei numai dupa decantare, cu eliminarea in treapta de
filtrare a manganului precipitat [1].
(3.7)
Doza teoretica necesara este de 1.9 g KmnO4: 1 g Mn2+, dar in practica valoarea este
influentata de pH si de compozitia apei, o parte din permanganatul de potasiu fiind redus de
materiile organice din apa. De asemenea se impune determinarea exacta a necesarului de KMnO4,
supradozarea conducand la aparitia unei ape de culoare roz in obiectele statiei de tratare, care
ulterior in conductele de aductiune devine de culoare galbena [1]
In cazul in care manganul nu se afla in combinatii cu materii organice, pH-ul optim pentru
oxidare este de 7.27.3, iar timpul de contact necesar este mai mic de 5 minute.
Daca manganul se afla in combinatii cu materii organice timpul de contact necesar creste
pna la 20 de minute, pentru accelerarea reactiei fiind necesara cresterea pH-ului pna la valoarea
de 8.5 [1].
Reactivii necesari in acest proces sunt in mod uzual oxigenul, de obicei asigurat prin aerare,
si uneori, in etapa de amorsare, permanganatul de potasiu;
15
CAPITOLUL 3
Consideratii teoretice
Pentru majoritatea apelor brute timpul de contact pentru aerare este redus si corespunde
timpului necesar pentru cresterea potentialului de oxido-reducere pna la valoarea
recomandata pentru dezvoltarea speciilor bacteriene;
Ca si in cazul proceselor biologice de deferizare, din activitatea bacteriana rezulta flocoane
rezistente, care permit utilizarea de viteze de filtrare ridicate, de pna la 30-40 m/h;
diametrul efectiv al granulelor materialului filtrant trebuie sa fie mai mari decat in cazul
proceselor de deferizare biologica, incadrandu-se in jurul valorii de 1.35 mm;
Spalarea filtrelor se poate face cu apa bruta sau cu apa filtrata, neclorata;
Namolurile rezultate se pot deshidrata usor.
In cazul in care apa necesita atat deferizare cat si demanganizare, si exista posibilitatea
adoptarii de procese biologice in aceste scopuri, datorita conditiilor foarte diferite impuse pentru
dezvoltarea bacteriilor utilizate, este necesara utilizarea a 2 trepte de filtrare [1].
16
CAPITOLUL 3
Consideratii teoretice
OCl H O 7.6
HOCl
(3.8)
Distributia formelor HOCl, OCl- este functie de pH. In conditiile apei de baut ramane o
cantitate foarte mica de clor sub forma moleculara.
Aceste trei tipuri Cl2, HClO si ClO- pot coexista, cate doua, in solutie apoasa.
17
CAPITOLUL 3
Consideratii teoretice
Alura acestor curbe este influentata de numerosi parametri cum ar fi: pH, alcalinitate,
forma de clor utilizata (gazos sau hipoclorit).
18
CAPITOLUL 3
Consideratii teoretice
Figura 3.3. Reprezentarea grafica a curbei de clorinare a apelor cu continut de azot amoniacal [1].
19
CAPITOLUL 3
Consideratii teoretice
NO3-
20
CAPITOLUL 3
Consideratii teoretice
Epuizarea - procesul se desfasoara pana cand matricea se satureaza, iar ionii ce trebuie
separati nu mai sunt retinuti de rasina, si apar la iesirea din coloana, momentul fiind
marcat de cresterea brusca a concentratiei ionice;
Datele din literatura pun in evidenta posibilitatea reducerii concentratiei de amoniu din
apa prin utilizarea cationitilor sintetici puternic acizi in forma Na respectiv in forma H si a zeolitilor
artificiali.
Capacitatea de schimb a zeolitilor, determinata pe apa sintetica (apa care nu contine si alti
cationi in afara de amoniu) a fost de 9 mg N-NH4+/ g zeolit.
S-a demonstrat ca in cazul rasinii sintetice Lewatit 500A capacitatea de schimb a acesteia
se epuizeaza dupa un volum de apa trecut prin rasina de 2750 BV (bed volumes) cu o concentratie
initiala de amoniu de 10 mg/l [16]. In cazul unei ape naturale cu aceeasi concentratie de amoniu
capacitatea de schimb a cationitului se epuizeaza dupa trecerea unui volum de apa de 295 BV [16].
Acesta pune in evidenta faptul ca ionul amoniu intra in competitie cu ceilalti cationi
prezenti in apa naturala (Ca2+, Mg2+) ceea ce conduce la epuizarea prematura a acpacitatii ed
schimb.
In cazul apelor cu mineralizare ridicata in care concentratia de calciu si magneziu este
ridicata iar concentratia de amoniu relativ scazuta schimbul ionic conduce la costuri ridicate
datorate regenerarii frecvente a cationitului. In plus, solutia rezultata de la regenerare care
contine concentratii ridicate de sare si amoniu reprezinta un deseu care poate crea complicatii in
gestionare (nu poate fi acceptat in statia de epurare).
21
CAPITOLUL 3
Consideratii teoretice
2.
Proces
Clorare
point
la
Avantaje
break-
Procese biologice
Dezavantaje
eficiente ridicate;
necesar automatizare;
proces
dependent
temperatura, alcalinitate,
oxigen dizolvat;
de
pH,
22
Nr.crt.
3.
4.
Proces
Schimb ionic
Osmoza inversa
CAPITOLUL 3
Consideratii teoretice
Avantaje
Dezavantaje
cazul apelor cu alcalinitate
redusa;
gestionare
biomasei;
complicata
eficienta ridicata;
operare simpla;
necesar automatizare;
necesar
reactivi
regenerare;
pentru
eficienta ridicata;
operare simpla
necesar automatizare;
necesar remineralizare
23
CAPITOLUL 4
Rezultatele cercetarilor experimentale
Dezinfectie.
Ciclul experimental nr. II. In acest ciclu expeimental s-a optat pentru retinerea separata a
manganului si apoi, intr-o treapta de tratare ulterioara, prin clorare la break-point, retinerea
azotului amoniacal.
Retinere mangan:
Dezinfectie.
24
CAPITOLUL 4
Rezultatele cercetarilor experimentale
BAZIN PRE-OXIDARE
Tc=27 min.
Q =200 dm /h
ADSORBTIE CAG
EBCT=17.7 min.
DEZINFECTIE
Tc=42 min.
Doza de clor necesara a fost determinata experimental, prin efectuarea unei curbe de
clorare la break-point, prezentata in figura urmatoare.
25
CAPITOLUL 4
Rezultatele cercetarilor experimentale
3.5
3
Amoniu
Clor total
NH4 (mg/l)
2.5
2
1.5
1
0.5
0
0
10
15
20
Figura 4.2. Curba clorare apa bruta Slatina, SP Balcescu ciclul experimental I.
NR.
CRT.
PARAMETRU
UM
VALOARE
GENERAL
1
l/s
l/h
PARAMETRII CALITATE APA BRUTA
TURBIDITATE
NTU
pH
Fe
mg/l
Mn
mg/l
NH4+
mg/l
SCHEMA DE TRATARE
PRE-OXIDARE CU CLOR
FILTRARE RAPIDA PE NISIP
ADSORBTIE PE CARBUNE ACTIV GRANULAR
DEBIT APA BRUTA
0.056
200.0
0.3
8.4
0.04
0.084
1.710
26
4
4.1
4.2
4.3
4.4
5
5.1
5.2
CAPITOLUL 4
Rezultatele cercetarilor experimentale
TIMP DE CONTACT
DOZA Cl2
CONCENTRATIE Cl2
DEBIT POMPA
mg/l
%
ml/min
FILTRU RAPID DE NISIP
m/h
VITEZA DE FILTRARE
INTENSITATE APA SPALARE
l/s,m2
ETAPA 1
l/s,m
ETAPA 2
27.33
15.00
0.140
36.00
5.0
3.0
6.0
TIMP SPALARE
5.3
min
min
ETAPA 1
ETAPA 2
10.0
15.0
ETAPA 1
ETAPA 2
l/h
l/h
FILTRU CARBUNE ACTIV GRANULAR
6.1
6.2
7
EBCT
VITEZA DE FILTRARE
7.1
TIMP DE CONTACT
DOZA NaOCl
7.2
675.0
1350.0
min
m/h
17.7
4.1
min
41.8
0.5
DEZINFECTIE (CLOR)
mg Cl2/l
In figurile care urmeaza sunt prezentate imagini din timpul experimentelor efectuate in
acest ciclu experimental.
Instalatia pilot a functionat cu un debit de 200 dm3/h, o perioada de 10 ore iar tratarea a
constat in:
In tabelul urmator este prezentata calitatea apei tratate comparativ cu calitatea apei brute
utilizand schema de tratare mentionata. Buletinele de analiza sunt date in anexa 2.
Prin clorare la break-point si filtrare rapida pe nisip s-a redus atat concentratia de mangan
cat si concentratia de amoniu sub limita admisa pentru apa potabila.
Doza de clor a fost ajustata astfel incat concentratia de amoniu in apa filtrata sa fie sub
limita admisa pentru apa potabila.
27
CAPITOLUL 4
Rezultatele cercetarilor experimentale
Tabel 4.2. Calitatea apei tratate si a apei brute din localitatea Slatina, SP Balcescuciclul experimental I.
Nr.
Indicator
U.M.
Valoare
Legea 458/2002 cu
crt.
modificarile si
AB
AFRN
AFCAG
completarile
ulterioare
1
pH*
Unitati pH
8.38
8.35
8.27
6.5-9.5
Turbiditate*
FNU
0.314
0.25
0.05
<5
Conductivitate
S/cm
506
2500
Duritate totala
Grade
5.15
min.5
28
Indicator
CAPITOLUL 4
Rezultatele cercetarilor experimentale
U.M.
Valoare
AB
AFRN
AFCAG
Legea 458/2002 cu
modificarile si
completarile
ulterioare
germane
5
Fier
g/l
40
3.8
8.3
200
Mangan*
g/l
84
28
13
50
Sulfat
mg/l
7.75
250
Cloruri
mg/l
20.18
250
Sodiu
mg/l
89.1
200
10
Amoniu*
mg/l
1.7
0.12
0.11
0.5
11
Azotati
mg/l
0.47
1.94
0.33
50
12
Azotiti
mg/l
0.08
0.023
0.014
0.5
13
Indice permanganat
mgO2 /l
1.6
1.44
1.76
14
Bor
mg/l
0.796
1.0
15
g/l
<10
100
16
Arsen
g/l
<0.2
10
17
Cadmiu
g/l
<0.12
18
Crom total
g/l
<0.4
50
19
Cupru
mg/l
1.4
0.1
20
Plumb
g/l
<0.05
10
21
Nichel
g/l
<0.4
20
22
Seleniu
g/l
<0.1
10
23
Stibiu
g/l
<0.3
5.0
24
Fluoruri
mg/l
0.31
1.2
25
Mercur
g/l
<0.01
26
mg/l
1.24
1.15
0.56
Nici o modificare
anormala
27
Aluminiu
g/l
16.7
200
28
Zinc
g/l
27.7
5000
Hidrocarburi aromatice
policiclice
-benzo(b)fluoranten
g/l
<0.0006
-benzo(k)fluoranten
g/l
<0.0006
-benzo(ghi)perilen
g/l
<0.0006
-indeno(1,2,3-cd)piren
g/l
<0.0006
30
Pesticide organoclorurate
g/l
<0.001
0.1
31
Pesticide triazinice
g/l
<0.008
0.1
32
Pesticide organofosforice
g/l
<0.001
0.1
Tetracloretena si
g/l
<0.05
Tricloretena
g/l
<0.05
Bromati**
g/l
<0.5
29
33
34
0.1
10
10
29
Indicator
CAPITOLUL 4
Rezultatele cercetarilor experimentale
U.M.
Valoare
AB
AFRN
AFCAG
Legea 458/2002 cu
modificarile si
completarile
ulterioare
35
Benzen
g/l
<0.05
36
Cianuri totale
g/l
<10
50
37
Cianuri libere**
g/l
<10
38
1,2 Dicloretan
g/l
<0.25
39
Epiclorhidrina
g/l
<0.05
0.10
40
Clorura de vinil
g/l
<0.05
0.50
41
Clor liber*
mg/l
0.081
<0.01
0.5
42
Clor total*
mg/l
0.31
<0.01
43
Trihalometani
g/l
<0.15
<0.15
100
pentru indicatorii ale caror valori determinate pe apa bruta nu au depasit limitele maxim admise
pentru apa potabila nu s-au efectuat analize pe apa tratata deoarece acestia nu se schimba in
procesul de tratare aplicat;
10.00
Amoniu
Mn
1.00
mg/l
Legea 458/2002 - Mn
0.10
0.01
AB
AB
AFRN
APREOX
AFCAG
AFRN
AFCAG
30
CAPITOLUL 4
Rezultatele cercetarilor experimentale
Mangan
Amoniu
Clor liber
Clor total
mg/l
0.1
0.01
1
Timp (ore)
Figura 4.6. Variatia in timp a principalilor indicatori pentru apa filtrata pe nisip - ciclul I.
Pe parcursul experimentelor a fost monitorizat pH-ul care a avut valori de 8.33 pentru apa
bruta si valori cuprinse in domeniul 8.2 8.3 pentru apa filtrata pe nisip respectiv 8.2 8.4 pentru
apa filtrata pe carbune activ granular.
31
CAPITOLUL 4
Rezultatele cercetarilor experimentale
32
CAPITOLUL 4
Rezultatele cercetarilor experimentale
BAZIN PRE-OXIDARE
Tc=27.3 min.
Q =200 dm /h
CLORARE BREAK-POINT
Tc=41.8 min.
ADSORBTIE CAG
EBCT=17.7 min.
DEZINFECTIE
Tc=42 min.
33
CAPITOLUL 4
Rezultatele cercetarilor experimentale
precipitatul negru de MnO2 se retine usor din apa prin filtrare pe nisip;
dioxidul de mangan format are proprietatea de a adsorbi alti ioni din apa (Fe 2+,
Mn2+, Ra2+) marind astfel eficienta de reducere a acestor ioni;
2.5
Amoniu
NH4 (mg/l)
Clor total
1.5
0.5
0
0
10
15
20
Figura 4.8. Curba clorare apa filtrata Slatina, SP Balcescu, ciclul experimental II.
CAPITOLUL 4
Rezultatele cercetarilor experimentale
NR.
CRT.
PARAMETRU
UM
VALOARE
GENERAL
1
4
4.1
4.2
4.3
4.4
5
5.1
5.2
l/s
l/h
PARAMETRII CALITATE APA BRUTA
TURBIDITATE
NTU
pH
Fe
mg/l
Mn
mg/l
+
NH4
mg/l
SCHEMA DE TRATARE
PRE-OXIDARE CU PERMANGANAT DE POTASIU
FILTRARE RAPIDA PE NISIP
POST-OXIDARE CU CLOR
ADSORBTIE PE CARBUNE ACTIV GRANULAR
DEZINFECTIE (HIPOCLORIT DE SODIU)
PREOXIDARE
0.056
200.0
min
TIMP DE CONTACT
mg/l
DOZA KMnO4
%
CONCENTRATIE KMnO4
ml/min
DEBIT POMPA
FILTRU RAPID DE NISIP
m/h
VITEZA DE FILTRARE
INTENSITATE APA SPALARE
l/s,m2
ETAPA 1
27.33
0.21
0.007
10.20
l/s,m
ETAPA 2
0.25
8.4
0.04
0.091
1.200
5.0
3.0
6.0
TIMP SPALARE
5.3
min
min
ETAPA 1
ETAPA 2
10.0
15.0
l/h
l/h
POSTOXIDARE CU HIPOCLORIT DE SODIU
DEBIT APA FILTRATA
l/h
675.0
1350.0
6.3
6.4
6.5
7
min
TIMP DE CONTACT
mg Cl2/l
DOZA NaOCl
%
CONCENTRATIE NaOCl
ml/min.
DEBIT POMPA
FILTRU CARBUNE ACTIV GRANULAR
41.8
15.0
0.140
36
7.1
EBCT
6
6.1
6.2
ETAPA 1
ETAPA 2
min
200.0
17.7
35
NR.
CRT.
7.2
8
8.1
8.2
PARAMETRU
VITEZA DE FILTRARE
CAPITOLUL 4
Rezultatele cercetarilor experimentale
UM
VALOARE
m/h
4.1
min
23.6
0.5
DEZINFECTIE (CLOR)
TIMP DE CONTACT
DOZA NaOCl
mg Cl2/l
O analiza in detaliu a calitatii apei brute a fost efectuata de laboratoarele ECOIND. Buletinul
de analiza este dat in anexa 3. Apa bruta a avut o calitate similara cu cea procesata in ciclul
experimental I.
In figurile urmatoare sunt prezentate imagini din timpul experimentelor.
Solutia de permanganat de potasiu a fost injectata pe la partea inferioara a coloanei de
preoxidare iar aceasta a fost alimentata cu apa bruta prin partea superioara. Timpul de contact in
pre-oxidare a fost de 27.33 min.
Apa pre-oxidata, evacuata in zona inferioara a coloanei de pre-oxidare a intrat in filtrul
rapid de nisip pe la partea superioara. Viteza de filtrare a fost de 5 m/h.
Efluentul filtrului de nisip a fost pompat in coloana de post-oxidare unde s-a dozat
hipoclorit de sodiu 15 mg Cl2/l. Timpul de contact in coloana de post-oxidare a fost de 41.8 min.
Apa post-oxidata a fost pompata in filtrul cu carbune activ granular pentru retinerea prin
adsorbtie a eventualilor sub-produsi de reactie formati in timpul clorarii la break-point.
Dat fiind faptul ca dozele de clor necesare reactiei azotului amoniacal sunt foarte mari, si
timpii de contact necesari sunt mai mari de 30 min. probabilitatea de a se forma sub-produsi de
reactie (cloramine, trihalometani) este ridicata.
In tabelul urmator este data calitatea apei brute comparativ cu cea a apei filtrate pe nisip
respectiv efluentul filtrului de carbune activ granular.
36
CAPITOLUL 4
Rezultatele cercetarilor experimentale
Figura 4.9. Sistem injectie permanganat de potasiu si coloana pre-oxidare - ciclul II.
Tabel 4.4. Calitatea apei tratate si a apei brute din localitatea Slatina, SP Balcescu ciclul experimental II.
Nr.
Indicator
U.M.
Valoare
Legea 458/2002
crt.
cu modificarile
AB
AFRN APOX AFCAG si completarile
ulterioare
1
pH*
Unitati pH
8.36
8.32
8.28
8.31
6.5-9.5
Turbiditate*
FNU
0.21
0.2
0.22
0.28
<5
Conductivitate
S/cm
512
2500
Duritate totala
Grade
germane
4.58
min.5
Fier
g/l
23.8
4.4
38.2
200
37
Indicator
CAPITOLUL 4
Rezultatele cercetarilor experimentale
U.M.
Valoare
Mangan*
g/l
91
20
10
Legea 458/2002
cu modificarile
si completarile
ulterioare
50
Sulfat
mg/l
7.06
250
Cloruri
mg/l
19.48
250
Sodiu
mg/l
82.7
200
10
Amoniu*
mg/l
1.2
0.99
0.02
0.02
0.5
11
Azotati
mg/l
0.51
0.64
4.84
50
12
Azotiti
mg/l
0.069
0.04
<0.003
0.5
13
Indice permanganat
mgO2 /l
1.6
1.44
1.76
14
Bor
mg/l
0.076
1.0
15
g/l
<10
100
16
Arsen
g/l
<0.2
10
17
Cadmiu
g/l
<0.12
18
Crom total
g/l
<0.4
50
19
Cupru
mg/l
1.1
0.1
20
Plumb
g/l
<0.05
10
21
Nichel
g/l
<0.4
20
22
Seleniu
g/l
<0.1
10
23
Stibiu
g/l
<0.3
5.0
24
Fluoruri
mg/l
0.29
1.2
25
Mercur
g/l
<0.01
26
mg/l
1.23
1.22
0.54
Nici o modificare
anormala
27
Aluminiu
g/l
17.1
200
28
Zinc
g/l
27.2
5000
AB
AFRN
APOX
AFCAG
Hidrocarburi aromatice
policiclice
-benzo(b)fluoranten
g/l
<0.0006
-benzo(k)fluoranten
g/l
<0.0006
-benzo(ghi)perilen
g/l
<0.0006
-indeno(1,2,3-cd)piren
g/l
<0.0006
30
Pesticide organoclorurate
g/l
<0.001
0.1
31
Pesticide triazinice
g/l
<0.008
0.1
32
Pesticide organofosforice
g/l
<0.001
0.1
Tetracloretena si
g/l
<0.05
Tricloretena
g/l
<0.05
34
Bromati**
g/l
<0.5
10
35
Benzen
g/l
<0.05
36
Cianuri totale
g/l
<10
50
29
33
0.1
10
38
Indicator
CAPITOLUL 4
Rezultatele cercetarilor experimentale
U.M.
Valoare
AB
AFRN
APOX
AFCAG
Legea 458/2002
cu modificarile
si completarile
ulterioare
37
Cianuri libere**
g/l
<10
38
1,2 Dicloretan
g/l
<0.25
39
Epiclorhidrina
g/l
<0.05
0.10
40
Clorura de vinil
g/l
<0.05
0.50
41
Clor liber*
mg/l
0.58
0.01
0.5
42
Clor total*
mg/l
0.62
0.01
43
Trihalometani
g/l
<0.15
100
pentru indicatorii ale caror valori determinate pe apa bruta nu au depasit limitele maxim admise
pentru apa potabila nu s-au efectuat analize pe apa tratata deoarece acestia nu se schimba in
procesul de tratare aplicat;
10.00
Amoniu
Mn
Legea 458/2002 - NH4+
1.00
0.10
mg/l
Legea 458/2002 - Mn
0.01
0.00
AB
AB
AFRN
APOX
AFCAG
AFRN
APOX
AFCAG
Figura 4.10. Variatia concentratiei de amoniu si de mangan pe schema de tratare ciclul II.
AB apa bruta; AFRN apa filtrata rapid pe nisip; APOX apa post-oxidata cu clor; AFCAG apa filtrata pe
carbune activ granular.
Se observa ca prin oxidare cu permanganat de potasiu si filtrare rapida pe nisip s-a redus
concentratia de mangan la valori sub limita admisa pentru apa potabila (0.02 mg/l, valoarea
medie, fata de 0.05 mg/l concentratia maxim admisa pentru apa potabila). Concentratia de
amoniu nu s-a redus semnificativ, astfel ca in apa filtrata pe nisip aceasta a fost de 1 mg/l.
39
CAPITOLUL 4
Rezultatele cercetarilor experimentale
10
Mangan
Amoniu
Clor liber
Clor total
mg/l
0.1
0.01
1
Timp (ore)
Figura 4.11. Variatia in timp a concentratiei de mangan si amoniu din apa filtrata pe nisip si a concentratiilor
de clor din apa post-oxidata cu clor ciclul II.
40
CAPITOLUL 5
Concluzii si recomandari
5 Concluzii si recomandari
In vederea stabilirii tehnologiei optime, a parametrilor de functionare precum si a tipurilor
si dozelor de reactivi pentru tratarea apei prelevata de la statia de pompare Nicolae Balcescu,
Localitatea Slatina, jud. Olt s-au realizat doua cicluri experimentale pe instalatia pilot.
Analiza rezultatelor analizelor efectuate pe apra bruta in cadrul ciclurilor experimentale a
pus in evidenta urmatoarele:
conform datelor puse la dispozitie de beneficiar apa bruta prelevata din SP Balcescu
localitatea Slatina, jud. Olt prezinta depasiri ale concentratiei admise la turbiditate,
amoniu si mangan;
Azotul amoniacal poate fi redus la concentratii mai mici de 0.5 mg/l prin clorare la break-point.
Deoarece doza de clor stoechiometrica necesara este de 7.6 mg Cl2/mg N-NH4+, iar in practica
aceasta variaza in domeniul 9 14 mg Cl2/mg N-NH4+ variatia debitelor si a concentratiilor de
amoniu in apa bruta conduce la variatii ale concentratiilor de amoniu in efluent dar si la variatii
ale concentratiilor de clor rezidual liber si de clor total in apa tratata. In vederea asigurarii unui
proces stabil este necesara automatizarea procesului.
CAPITOLUL 5
Concluzii si recomandari
peste limita admisa si dozele de clor necesare oxidarii acestuia sunt extrem de reduse, se
prefera schema cu dozare de clor in pre-oxidare care sa asigure atat oxidarea manganului cat si
reactia cu ionul amoniu.
Pe baza celor prezentate se recomanda urmatoarea schema tehnologica pentru tratarea
apei din statia de pompare Balcescu, localitatea Slatina:
Preoxidare cu clor (10 - 20 mg/l) cu asigurarea unui timp de reactie de cel putin 30 min.;
Dezinfectie cu clor (0.5 mg/l) pentru a asigura doza de marcaj conform Legii privind calitatea
apei potabile cu completarile si adaugirile ulterioare.
ADSORBTIE CAG
EBCT=15 min.
DEZINFECTIE
Tc=30 min.
Calitatea apei tratate pe aceasta filiera de tratate, comparativ cu calitatea apei brute este
prezentata in tebelul urmator.
42
CAPITOLUL 5
Concluzii si recomandari
Tabel 5.1. Calitatea apei tratate si a apei brute din localitatea Slatina, SP Balcescuciclul experimental I.
Nr.
Indicator
U.M.
Valoare
Legea 458/2002 cu
crt.
modificarile si
AB
AFRN
AFCAG
completarile
ulterioare
1
pH*
Unitati pH
8.38
8.35
8.27
6.5-9.5
Turbiditate*
FNU
0.314
0.25
0.05
<5
Conductivitate
S/cm
506
2500
Duritate totala
Grade
germane
5.15
min.5
Fier
g/l
40
3.8
8.3
200
Mangan*
g/l
84
28
13
50
Sulfat
mg/l
7.75
250
Cloruri
mg/l
20.18
250
Sodiu
mg/l
89.1
200
10
Amoniu*
mg/l
1.7
0.12
0.11
0.5
11
Azotati
mg/l
0.47
1.94
0.33
50
12
Azotiti
mg/l
0.08
0.023
0.014
0.5
13
Indice permanganat
mgO2 /l
1.6
1.44
1.76
14
Bor
mg/l
0.796
1.0
15
g/l
<10
100
16
Arsen
g/l
<0.2
10
17
Cadmiu
g/l
<0.12
18
Crom total
g/l
<0.4
50
19
Cupru
mg/l
1.4
0.1
20
Plumb
g/l
<0.05
10
21
Nichel
g/l
<0.4
20
22
Seleniu
g/l
<0.1
10
23
Stibiu
g/l
<0.3
5.0
24
Fluoruri
mg/l
0.31
1.2
25
Mercur
g/l
<0.01
26
mg/l
1.24
1.15
0.56
Nici o modificare
anormala
27
Aluminiu
g/l
16.7
200
28
Zinc
g/l
27.7
5000
Hidrocarburi aromatice
policiclice
-benzo(b)fluoranten
g/l
<0.0006
-benzo(k)fluoranten
g/l
<0.0006
-benzo(ghi)perilen
g/l
<0.0006
-indeno(1,2,3-cd)piren
g/l
<0.0006
30
Pesticide organoclorurate
g/l
<0.001
0.1
31
Pesticide triazinice
g/l
<0.008
0.1
29
0.1
43
Indicator
CAPITOLUL 5
Concluzii si recomandari
U.M.
Valoare
AB
AFRN
AFCAG
Legea 458/2002 cu
modificarile si
completarile
ulterioare
Pesticide organofosforice
g/l
<0.001
Tetracloretena si
g/l
<0.05
Tricloretena
g/l
<0.05
34
Bromati**
g/l
<0.5
10
35
Benzen
g/l
<0.05
36
Cianuri totale
g/l
<10
50
37
Cianuri libere**
g/l
<10
38
1,2 Dicloretan
g/l
<0.25
39
Epiclorhidrina
g/l
<0.05
0.10
40
Clorura de vinil
g/l
<0.05
0.50
41
Clor liber*
mg/l
0.081
<0.01
0.5
42
Clor total*
mg/l
0.31
<0.01
43
Trihalometani
g/l
<0.15
<0.15
100
32
33
0.1
10
pentru indicatorii ale caror valori determinate pe apa bruta nu au depasit limitele maxim admise
pentru apa potabila nu s-au efectuat analize pe apa tratata deoarece acestia nu se schimba in
procesul de tratare aplicat;
NR.
CRT.
PARAMETRU
U.M.
VALOARE
SCHEMA DE TRATARE
PRE-OXIDARE CU CLOR
1
FILTRARE RAPIDA PE NISIP
ADSORBTIE PE CARBUNE ACTIV GRANULAR
DEZINFECTIE CU CLOR
2
BAZIN CONTACT PRE-OXIDARE
2.1 TIMP CONTACT
min
2.3 DOZA DE CLOR
FILTRU RAPID DE NISIP
TIP PROCES: FILTRARE CU NIVEL CONSTANT SI
3.1
DEBIT VARIABIL
3.2 VITEZA DE FILTRARE IN CICLU DE FILTRARE
3.3 VITEZA DE FILTRARE IN CICLU DE SPALARE
30
mg Cl2/l
10 - 20
m/h
m/h
5
MAX 8
%
mm
MIN. 95
0.9 1.0
3.4
44
NR.
CRT.
3.5
3.6
4
4.1
4.2
5
5.1
PARAMETRU
CAPITOLUL 5
Concluzii si recomandari
U.M.
- COEFICIENT DE UNIFORMITATE
- DENSITATE APARENTA
g/cm3
- DENSITATE REALA
g/cm3
- POROZITATE
%
- FRIABILITATE
%
- PIERDEREA LA ACID
%
- INALTIME STRAT
m
DRENAJ CU PLACI CU CREPINE
SPALARE IN CONTRACURENT CU APA SI AER:
- ETAPA 1: CU AER SI APA SIMULTAN:
- INTENSITATE APA:
l/s,m2
- INTENSITATE AER:
l/s,m2
- DURATA:
min.
- ETAPA 2: CU APA:
- INTENSITATE APA:
l/s,m2
- DURATA:
min.
ADSORBTIE - FILTRU CARBUNE ACTIV GRANULAR
min
EBCT (Empty Bed Contact Time)
TIP PROCES: FILTRARE CU NIVEL CONSTANT SI
DEBIT VARIABIL
DEZINFECTIE
min
TIMP CONTACT
mg Cl2/l
VALOARE
< 1.6
1.4 1.6
2.4 2.6
40
<5
<2
1.20
4
18
10
8
15
15
15
0.5
45
BIBLIOGRAFIE
Bibliografie
1.
2.
3.
Legea 458/2002 M.O. Nr. 552/29 iulie 2002 - Legea privind calitatea apei potabile cu
completarile si modificarile ulterioare.
4.
AWWA - Water Quality and Treatment a handbook of community water supplies fifth
edition;
5.
http://www.nhmrc.gov.au/_files_nhmrc/publications/attachments/eh52_aust_drinking_water_gu
idelines_update_131216.pdf
6.
HDR ENGINEERING INC. Handbook of Public Water Systems, 2nd Edition. John Wiley &
Sons, Inc, 2001.
7.
WHO. Guidelines for Drinking Water Quality, Third Edition, Volume 1. Geneva, 2008;
8.
9.
10.
John F. McPeak, Harold L. Aronovitch. Iron in water and processes for its removal.
Hungerford & Terry, Inc, Philadelphia, Pennsylvania, 1983.
11.
Szabolcs Tak - Ammonium removal from drinking water - comparison of the breakpoint
chlorination and the biological technology - Conference of Junior Researchers in Civil
Engineering pag. 248 254.
12.
S. Chen, C Zhun: Nitrification kinetics of biofilm as affected by water quality factors Original Research Article, Aquacultural Engineering, Volume 34, Issue 3, May 2002, Pages
179-197.
13.
Wilczak, Andrzej - Chloramine Decay Rate: Factors and Research Needs - 2001 AWWA,
Annual Conference Proceedings. Washington, D.C.: AWWA. 2001.
14.
Kirmeyer, Gregory J., Lee H. Odell, Joe Jacangelo, Andrzej Wilczak and Roy Wolfe. Nitrification Occurrence and Control in Chloraminated Water Systems. Denver,
Colo.:AwwaRF and AWWA. (1995).
15.
Shulin Chen, Jian Ling, Jean-Paul Blancheton - Nitrification kinetics of biofilm as affected by
water quqlity factors - Water Research, Aquacultural Engineering 34, 179197 (2006).
16.
46
ANEXA 1
SCHEMA TEHNOLOGICA A STATIEI PILOT
ANEXE
ANEXE
ANEXA 2
BULETINE ANALIZA CICLUL EXPERIMENTAL I
ANEXA 2.1
BULETINE DE ANALIZA BENEFICIAR
ANEXE
ANEXA 2.2
BULETINE DE ANALIZA UTCB
ANEXE
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
8.38
0.31
1.7
0.04
0.084
6.5 9.5
1
0.5
0.2
0.05
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
Clor liber
Clor total
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
mg/l
mg/l
8.35
0.25
0.12
0.01
0.028
0.081
0.31
6.5 9.5
1
0.5
0.2
0.05
0.5
-
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
Clor liber
Clor total
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
mg/l
mg/l
8.27
0.05
0.11
0.01
0.013
<0.01
<0.01
6.5 9.5
1
0.5
0.2
0.05
0.5
-
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
ANEXA 2.3
BULETINE DE ANALIZA ECOIND
ANEXE
ANEXA 3
ANEXA 3
BULETINE DE ANALIZA CICLUL EXPERIMENTAL
II
ANEXA 3.1
BULETINE DE ANALIZA BENEFICIAR
ANEXA 3
ANEXA 3.2
BULETINE DE ANALIZA UTCB
ANEXA 3
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
8.36
0.21
1.2
0.04
0.091
6.5 9.5
1
0.5
0.2
0.05
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
Clor liber
Clor total
AFRN Ciclul experimental II, jud. Olt, loc Slatina, SP Nicolae Balcescu;
Proba a fost recoltata de la iesirea din filtrul de nisip de Elena Vulpasu;
9.02.2016;
9.02.2016;
-
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
mg/l
mg/l
8.32
0.2
0.99
0.02
-
6.5 9.5
1
0.5
0.2
0.05
0.5
-
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
Clor liber
Clor total
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
mg/l
mg/l
8.31
0.28
0.02
0.01
<0.01
<0.01
6.5 9.5
1
0.5
0.2
0.05
0.5
-
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
FACULTATEA DE HIDROTEHNICA
DEPARTAMENT DE INGINERIE HIDROTEHNICA
LABORATORUL DE CHIMIA APEI SI A POLUANTILOR
Indicator
pH
Turbiditate
Amoniu
Fier
Mangan
Clor liber
Clor total
U.M.
Valoare
uniti
NTU
mg/l
mg/l
mg/l
mg/l
mg/l
8.28
0.22
0.02
0.58
0.62
6.5 9.5
1
0.5
0.2
0.05
0.5
-
incercari
c Se interzice reproducerea partiala a prezentului document fara acordul scris al UTCB.
Decan,
Prof.dr.ing. Ioan Bica
Elaborat,
Conf.dr.ing. chim. E. Vulpasu
ANEXA 3.3
BULETINE DE ANALIZA ECOIND
ANEXA 3