Product : imagePRESS C6000 / C6010 / C6000VP / C6010VP / C7000 / C7000VP


Title : E260-1000 Error

Error :
The Error occurred after a jam removal. E260-1000 is defined as 12V/ 24V power supply
error to the black developer HVT. (UN136). UN136 receives 24 VDC from the Main
Station Power Supply Relay Board (UN102). UN136 was not the cause of the error, just
the first to detect the loss of 24 Volts and indicated the error code.
The sources of 24 VDC power to the Main Station Power Supply Relay Board are
UN500 and UN501 in the Power Supply Unit.

7/3/2015 11:31 AM

2 of 5

http://www.techsupport.cusa.canon.com/kb/article?articleid=77615&sou...

UN500 get 208 VAC directly from the power cord terminal assembly when the breaker is
turned on. While UN501 receives 208 VAC from the AC Relay .
UN501 not receiving 208 VAC supply voltage is the focus of this article.
Check for 208 VAC at J4727 on UN501, if the voltage is not there manually engage the
AC Relay solenoid by pushing the black button on the bottom of the relay.

The AC Relay solenoid is activated by J1848 on the Main Station Power Supply
Relay Board UN102. This only happens when the main station front cover switches
SW111 and SW112 and the vertical path cover switch SW116 are closed.

7/3/2015 11:31 AM

3 of 5

http://www.techsupport.cusa.canon.com/kb/article?articleid=77615&sou...

Check the AC Relay or J1848 for these approximate voltages:


Cover Open: Purple 12.9mVDC / Orange: 13.1 mVDC.
Cover open: Purple 102 mVDC / Orange 12.3 VDC.
If DC is not measured on the orange wire with the covers closed, power off the machine
and disconnect J1814 on the Main Station Power Supply Relay PCB.
Check continuity of the switches using J1814 of the Main station Power supply Relay
Board. Use the pins shown in the diagram below.
0 Ohms should be measured with the covers closed.

7/3/2015 11:31 AM

4 of 5

http://www.techsupport.cusa.canon.com/kb/article?articleid=77615&sou...

If continuity is confirmed and 12VDC was not measured on the orange wire with all the
covers closed, Suspect a blown fuse FU6 on the Main station Power Supply Relay PCB.

7/3/2015 11:31 AM

5 of 5

http://www.techsupport.cusa.canon.com/kb/article?articleid=77615&sou...

Workaround :
In this case, fuse FU6 was open. Replacing the Main station Power Supply
FM2-2254-000 corrected the issue.
Canon USA, Inc. Engineering Services & Solutions Division