Drives and Tunnels

Drives and tunnels must be refilled above the embedment zone using the following materials
and methods:

20 mm Class 4 crushed rock, or embedment concrete sand or 5 mm minus (blown in,


not compacted),

Grouting, either by gravity, or under pressure. (Gravity grouting shall only be used for
tunnels where there is sufficient head.)

1.5m

ORDINARY BACKFILL

CLASS 4 BACKFILL

Figure 3: Backfill Around Shafts and Vertical Structures in Non-Trafficable Areas

Issue Date: Nov 2013

MRWA Specification No 04-03.2

Page 24 of 34

MRWA Melbourne Retail Water Agencies

1.5m

ORDINARY BACKFILL

Figure 4: Backfill Type 2 Property Service Jump Ups in Non-Trafficable Areas

Issue Date: Nov 2013

MRWA Specification No 04-03.2

Page 25 of 34

1.5m

MRWA Melbourne Retail Water Agencies

Figure 5: Backfill Type 4 Property Service Jump Ups in Non-Trafficable Areas