Sei sulla pagina 1di 218

Dell Compellent Storage Center

SC8000 Controller

Deployment Guide

Storage Center SC8000 Controller Deployment Guide


DocumentNumber:680087001
Revision

Date

Description

July2013

Initialrelease

August2013

ChangedSSN#setuptoreflectpreviousmethod,addedrecommendedEthernet
speed,updatednumberofbackendchainssupported,removedreferencesto
directconnectFCfrontendconnection.

December2013

Changednumberofsupportedchains.

May2014

RevisesoftwarestartupprocedureforSecureDataandSEDsimplementedin
version6.5software.

Notes, Cautions, and Warnings


Note: Indicatesimportantinformationthathelpsyoucompleteaprocedure.

Caution: Indicateseitherpotentialdamagetohardwareorlossofdataandtellsyouhowtoavoid
theproblem.
Warning: Indicatesthatfailuretofollowdirectionscouldresultinpropertydamage,personal
injury,ordeath.

Copyright Notice and Trademarks


2014DellInc.
Trademarksusedinthistext:Dell,theDelllogo,andCompellentaretrademarksofDellInc.

Contacting Dell Technical Support Services


Fortechnicalsupport,gotosupport.dell.com/compellent/.

Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage Center Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage Center Architecture Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Communication Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Front End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Back End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Administration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC8000 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC8000 Front-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC8000 Back-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 SAS Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 Enclosure Front Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 Drawer Front-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 Back-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 EMM Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 Power Supply Unit Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Module Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 Enterprise Plus Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC280 Drive Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC200/220 SAS Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC200/220 Front-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC200/220 Back-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC200/220 EMM Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC200/220 Enterprise Plus Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SC200/220 Drive Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dell Compellent

1
2
2
2
2
3
4
5
5
5
6
7
10
12
13
14
15
16
17
18
19
20
20
21
22
23
24
25

iii

Contents

EN-SASx6x12/24 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN-SASx6x12/24 Front-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN-SASx6x12/24 Back-Panel Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN-SASx6x12/24 SBB Module Features and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN-SASx6x12/24 Standard SAS Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EN-SASx6x12/24 Drive Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26
26
27
28
29
30

2 Install the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31


Prepare for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unpack and Inventory the Storage Center Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prepare the Installation Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gather Required Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic Discharge Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install IO Cards the Controller(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Open the Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install IO Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Close the Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Label the Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mount the Hardware in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2U and 3U Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5U Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Drives in SC280 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Drives in EN-SASx6x12/24 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing 3.5" Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing 2.5" Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Enterprise Plus Drives in SC200/220 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31
31
31
32
32
32
33
34
35
35
37
43
44
45
45
46
48
48
50
50
52
53

3 Connect the Back End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55


SAS Enclosure Cabling Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
SAS Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
SC8000 SAS Port Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

iv

Storage Center SC8000 Controller Deployment Guide

Contents

Connect IPC for Dual-Controller Storage Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Connect the Controllers with Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect the Controllers with SAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect SC200/SC220 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Single Enclosure, Low Profile SAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Single Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Four Enclosures, Single Chain, Low Profile SAS . . . . . . . . . . . . . . . . . .
Single Controller, Four Enclosures, Single Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Four Enclosures, Two IO Cards, Two Chains, Low Profile SAS . . . . . .
Single Controller, Four Enclosures, Two IO Cards, Two Chains . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, One Enclosure, Single Chain, Low Profile SAS . . . . . . . . . . . . . . . . . . . .
Dual Controllers, One Enclosure, Single Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Two Enclosures, Single Chain, Low Profile SAS . . . . . . . . . . . . . . . . . . .
Dual Controllers, Two Enclosures, Single Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Four Enclosures, Two Chains, Low Profile SAS . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Four Enclosures, Two Chains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Eight Enclosures, Two Chains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect SC280 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Single SC280 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Two SC280 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controller, Single SC280 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controller, Two SC280 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Two SC280 and Two SC200/SC220 Enclosures, Two Chains . . . . . . . . .
Connect EN-SASx6x12/24 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Single Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Four Enclosures, Single Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Controller, Four Enclosures, Two IO Cards, Two Chains . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Two Enclosures, Single Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dual Controllers, Four Enclosures, Single Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Label the Back-End Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

56
57
59
60
61
62
63
64
65
66
67
68
69
70
71
73
74
75
76
77
78
79
81
84
85
86
87
88
90
93

4 Connect the Front End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95


Types of Redundancy for Front-End Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multipath IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MPIO Behavior for Dual-Controller Storage Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MPIO Configuration Instructions for Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dell Compellent

95
96
96
96
v

Contents

Front-End Connectivity Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


Virtual Port Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Legacy Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Failover Behavior for Legacy Mode and Virtual Port Mode . . . . . . . . . . . . . . . . . . . . . . . . .
Fibre Channel Zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WWN Zoning Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Port Zoning Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect the Front End for a Single-Controller Storage Center . . . . . . . . . . . . . . . . . . . . . . . . .
Connect Servers to a Single Controller with No Redundancy . . . . . . . . . . . . . . . . . . . . . . .
Connect Servers to a Single Controller with Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect the Front End for a Dual-Controller Storage Center . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect Fibre Channel Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect iSCSI Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Label the Front-End Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

96
97
99
101
102
102
102
103
103
104
105
105
111
116

5 Set up the Storage Center Software . . . . . . . . . . . . . . . . . . . . . . . . . . . 119


Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hardware Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Software Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect the Ethernet Management and iDRAC Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect Single-Controller Management Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect Dual-Controller Management Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Label the Management Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Turn on the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure the Controller(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reset Hardware and System Serial Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Set Controller IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manage the iDRAC IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verify Software Support for Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Start the Storage Center Startup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Complete the Startup Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
License Agreement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Load the License File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Create a Disk Folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vi

119
119
120
120
120
121
121
122
122
124
124
124
125
126
127
128
129
129
130
132

Storage Center SC8000 Controller Deployment Guide

Contents

Add a Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Set the Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Set the System IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure a Key Management Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure SMTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Select Update Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Set Admin Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure IO Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Generate SSL Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Label SC200 and SC220 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

136
138
139
141
142
144
145
146
147
160
163

6 Perform Post-Setup Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165


Verify Connectivity and Failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Create Test Volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Test Connectivity and Failover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clean up Test Volumes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Change Administrative Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configure a Phone Home Proxy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phone Home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check for Storage Center Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Next Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

165
165
166
167
168
170
170
172
172

A Adding or Removing an Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173


Adding SC280 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding an SC280 Enclosure in a New Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding to an Existing SC280 Enclosure Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding SC200/220 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a New Chain of SC200/220 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding to an Existing SAS Enclosure Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding a Second SAS Enclosure, Second Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Release Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remove an SC280 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remove an SC200/SC220 Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dell Compellent

174
174
178
184
184
186
191
193
193
193
199

vii

Contents

B Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Troubleshooting the Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Troubleshooting Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Troubleshooting Licenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
Troubleshooting Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206

viii

Storage Center SC8000 Controller Deployment Guide

Preface
TheprefaceintroducesyoutotheStorageCenterdocumentation.Itprovidesthepurposeandaudienceof
thisdocumentaswellasalistofrelatedpublications.

Purpose
TheStorageCenterSC8000ControllerDeploymentGuideprovidescablinginstructionsforStorageCenter
controllers,switches,andenclosuresandprovidesinstructionsforconfiguringanewDellCompellent
StorageCenterusingtheSystemManagerStartupwizard.

Audience
TargetaudiencesforthisdocumentareDellinstallersandDellbusinesspartners.Theintendedreaderhas
aworkingknowledgeofstorageconcepts.

Related Publications
ThefollowingdocumentscomprisethecoreStorageCenterdocumentationset:

StorageCenterReleaseNotes
Containsinformationaboutfeaturesandopenandresolvedissuesforaparticularproductversion.

StorageCenterSystemManagerAdministratorsGuide
DescribestheStorageCenterSystemManagersoftwarethatmanagesanindividualStorageCenter.

StorageCenterSoftwareUpdateGuide
DescribeshowtoupgradeStorageCentersoftwarefromanearlierversiontothecurrentversion.

StorageCenterMaintenanceCDInstructions
DescribeshowtoinstallStorageCentersoftwareonStorageCentercontrollers.InstallingStorageCenter
softwareusingtheStorageCenterMaintenanceCDisintendedforuseonlybysitesthatcannotupdate
StorageCenterusingthestandardupdateoptionsavailablethroughtheStorageCenterSystem
Manager.

StorageCenterCommandUtilityReferenceGuide
ProvidesinstructionsforusingtheStorageCenterCommandUtility.TheCommandUtilityprovidesa
commandlineinterface(CLI)toenablemanagementofStorageCenterfunctionalityonWindows,
Linux,Solaris,andAIXplatforms.

StorageCenterCommandSetforWindowsPowerShell
ProvidesinstructionsforgettingstartedwithWindowsPowerShellcmdletsandscriptingobjectsthat
interactwiththeStorageCenterviathePowerShellinteractiveshell,scripts,andPowerShellhosting
applications.Helpforindividualcmdletsisavailableonline.

Dell Compellent

ix

DellTechCenter
Providestechnicalwhitepapers,bestpracticeguides, andfrequentlyaskedquestionsaboutDell
Storageproducts.Goto:http://en.community.dell.com/techcenter/storage/andselectDellCompellent
intheTableofContents.

Storage Center SC8000 Controller Deployment Guide

Introduction
TheStorageCenterSC8000ControllerDeploymentGuidedescribeshowtoinstalland
configureDell CompellentStorageCenter.TheinformationprovidedinthisDeployment
GuideisintendedtobeusedbyDellinstallersandDellbusinesspartners.

Contents
StorageCenterHardwareComponents .......................................... 2
StorageCenterArchitectureOptions ............................................ 3
CommunicationLinks ........................................................ 4
SC8000Controller ............................................................ 6
SC280SASEnclosures ....................................................... 12
SC200/220SASEnclosures .................................................... 20
ENSASx6x12/24Enclosures .................................................. 26

Dell Compellent

Chapter 1 Introduction

Storage Center Hardware Components


ADellCompellentStorageCenterconsistsofoneortwocontrollers,switches,andoneor
moreenclosures.

Controllers
AStorageCentercontrollerprovidesthecentralprocessingcapabilityfortheStorage
CenterOperatingSystem(OS),applicationsoftware(StorageCenterSystemManager),and
managingRAIDstorage.AStorageCentercanbeconfiguredwithasinglecontroller
(singlecontrollerStorageCenter)orapairofcontrollers(dualcontrollerStorageCenter).
InadualcontrollerStorageCenterconfiguration,thepairofcontrollersmustbethesame
controllermodel.
IOcardsinthecontrollerprovidecommunicationwithdriveenclosuresandserversthat
usethestorage.ControllersprovidetwotypesofIOports:

Frontendports:Hosts,servers,orNetworkAttachedStorage(NAS)appliancesaccess
storagebyconnectingtocontrollerFibreChannelIOcards,FCoEIOcards,oriSCSIIO
cardsthroughoneormoreFibreChannelorEthernetnetworkswitches.Portsforthese
connectionsarelocatedonthebackofthecontroller,butaredesignatedasfrontend
ports.

Backendports:Enclosures,whichholdthephysicaldrivesthatprovidebackend
storage,connectdirectlytothecontroller.FibreChannelandSAStransportsare
supportedthroughportsdesignatedasbackendports.Backendportsareintheirown
privatenetworkbetweenthecontrollersandthedriveenclosures.

Switches
DellCompellentoffersFibreChannel(FC)andiSCSIswitchesandIOcardsaspartofthe
totalStorageCenterproductpackage.Switchesproviderobustconnectivitytoservers,
allowingfortheuseofmultiplecontrollersandredundanttransportpaths.Cabling
betweenthecontrollerIOcardsandswitches(andservers)isreferredtoasfrontend
connectivity.

Enclosures
Enclosureshouseandcontroldrivesthatprovidestorage.Enclosuresareconnected
directlytocontrollerIOcards.Theseconnectionsarereferredtoasbackendconnectivity.

NewStorageCenterdeploymentsuse6GBSerialAttachedSCSI(SAS)diskenclosures.

FibreChannelSwitchedBunchofDisks(SBOD)andSerialAdvancedTechnology
Attachment(SATA)enclosuresaresupportedforexistingStorageCentersandfor
controllermigrationsonly(forexample,upgradinganexistingStorageCenterby
migratingfromaCTSC040controllertoanSC8000controller).

Storage Center SC8000 Controller Deployment Guide

Storage Center Architecture Options

Storage Center Architecture Options


TheDellCompellentStorageCentercanbedeployedinavarietyofconfigurations:

SingleController,SingleEnclosure

SingleController,MultipleEnclosures

DualController,SingleEnclosure

DualController,MultipleEnclosures

Figure 1. Storage Center Architectures


Additionally,StorageCentersitescanbecolocatedorremotelyconnectedandcontinueto
shareandreplicatedatabetweensites.Replicationisusedtoduplicatevolumedatato
supportaDisasterRecoveryPlanortoproviderapidlocalaccesstoaremotedatavolume.
Typically,dataisreplicatedremotelytosafeguardagainstlocalorevenregionaldata
threatsaspartofanoverallDisasterRecoveryPlan.

Dell Compellent

Chapter 1 Introduction

Communication Links
AStorageCentercontrollerusesmultipletypesofcommunicationlinksforbothdata
transferandadministrativefunctions.Communicationlinksareclassifiedintothreetypes:
frontend,backend,andsystemadministration.
1

Figure 2. SC8000 Controller Communication Links


Item Description

Speed

Type

ServerwithFibreChannelHostBus
Adapters(HBAs)

8Gbor16Gb

FrontEnd

FibreChannelSwitches

8Gbor16Gb

FrontEnd

ServerwithFibreChanneloverEthernet
(FCoE)HBAsoriSCSIHBAs

10Gb

FrontEnd

EthernetSwitches

1Gbor10Gb

FrontEnd

SC8000Controller

IOcarddependent

N/A

SASEnclosure

6Gbperchannel

BackEnd

1Gbor10Gb

Note: FCenclosuresaresupportedfor
SC8000controllermigrationsonly.

Ethernet

10Mb,100Mb,or1Gb System
capability(seeNote,
Administration
page 5)

Serial

115,200Kbps

System
Administration

Storage Center SC8000 Controller Deployment Guide

Communication Links

Front End
FrontEndconnectivityprovidesconnectionsfromserverstocontrollersusingeither
Ethernet(iSCSI)orFibreChannelswitches.FrontEndconnectivityalsosupportsall
replicationtraffic.

iSCSIconnectionsprovidereadsandwritesfromaservertoacontrollerthroughan
Ethernetswitch.

FibreChanneloverEthernet(FCoE)usestheFCoEprotocolfordataonthefrontendfor
losslesstransmissionofdata.

FibreChannel(FC)connectionsonthefrontendareusedtoprovidereadsandwrites
fromaservertoacontroller.

Back End
Backendconnectivityisstrictlybetweenthecontrollersandenclosures.Thefollowing
protocolsaresupportedtocommunicatewiththeenclosures.

SASusesapointtopointswitchedtoptopologyonfourlanes.Eachlanecanperform
concurrentIOtransactionsat6Gb/sec.(Transferspeedsforearlierversionsare3Gb/
sec.)

FibreChannelconnectionswereusedonthebackendforCTSC040controllers.Fibre
ChannelIOcardscanbemigratedfromCTSC040controllerstoSC8000controllers.

System Administration
ThefollowingconnectionsareusedforcommunicatingwithcomputersoutsideofStorage
Center:

Serial:Usedforinitialconfigurationandotherservicerelatedtasks.

Ethernet:UsedforadministrationandIPCbetweenthecontrollers.

ETH0port:Configuration,administration,andmanagementofaStorageCenter.

ETH1port:InterProcessCommunications(IPC)betweencontrollers.
Note: TheEthernetportsonthebackofthecontrollercanoperateat10Mb,100
Mbor1Gb.Theseportsarenotusedforserverorenclosureconnectivity.For
optimalperformance,connecttotheportusing1Gbps.

Dell Compellent

iDRAC:ProvidesaccesstotheIntegratedDellRemoteAccessController(iDRAC)for
integratedpeercontrollermanagementthroughadedicated1GbEthernetport.

Chapter 1 Introduction

SC8000 Controller
TheStorageCenterSC8000controllershipswithtwoCPUs,acachecard,anIntegratedDell
RemoteAccessController7(iDRAC7),andafourportIntelnetworkdaughtercard.Upto
sixIOcardscanbeinstalled:threefullheightandthreelowprofile.TheStorageCenterOS
isinstalledonanembeddedSecureDigital(SD)card.

Figure 3. Dell Compellent SC8000 Controllers


Component

Description

Processor

2.50GHzDual6core

BusSpeed

1333MHz

SystemCache

16GB
(expandableto64GB)

CacheCard

512MB
PCIe(Slot7)

ExpansionSlots

Gen3PCIe:
Threefullheight,
Threelowprofile

TransportSpeeds
FibreChannel
FCoE
SAS
iSCSI

8Gbor16Gb
10Gb
3Gb,6Gb
1Gb,10Gb
Note: 3GbSASissupportedformigrationsonly;3 GbSAS
enclosuresaresupportedusinga6GbIOCard.

MaximumFrontEnd(FC)Ports 14
(Usingtwo4portIOcardsplusthree2portIOcards)

MaximumBackEndPorts

20
(Usingfive4portIOcards)

MaximumBackEndSAS
ChainsSupported

Maximum6GbSASDrives

168drives/chain,upto1008totaldrives

Maximum3GbSASDrives

48drives/chain=288

Storage Center SC8000 Controller Deployment Guide

SC8000 Controller

Component

Description

FormFactor

2U

PowerSupplies

Fans

SC8000 Front-Panel Features and Indicators


Thefrontpanelofthecontrollercontainspowerandresetswitches,andanLCDpanelthat
showssystemID,status,anderrorinformation.
1

3 4

Figure 4. Front Panel Features and Indicators


Item Name

Icon Description

Poweronindicator,
powerbutton

Thepoweronindicatorisilluminatedwhenthecontroller
powerispoweredon.Thepowerbuttoncontrolsthepower
supplyoutputtothecontroller.

NMIbutton

FortheSC8000,thisbuttonisdisabledintheBIOS.

System
identification
button

Usedtolocateaparticularcontrollerwithinarack.Whena
SystemIDbuttononthefrontorbackpanelispressed,thefront
LCDpanelandthebacksystemstatusindicatorflashuntilone
ofthebuttonsispressedagain.
PresstotogglethesystemIDonandoff.
IfthecontrollerstopsrespondingduringPOST,pressand
holdthesystemIDbuttonformorethanfivesecondstoenter
BIOSprogressmode.

Videoconnector

AllowsyoutoconnectaVGAmonitortothecontroller.

LCDmenubuttons

AllowsyoutonavigatethecontrolpanelLCDmenu.

LCDpanel

DisplayssystemID,statusinformation,andsystemerror
messages.
TheLCDlightsblueduringnormalcontrolleroperation.
TheLCDlightsamberwhenthecontrollerneedsattention,
andtheLCDpaneldisplaysanerrorcodefollowedby
descriptivetext.
Note: Ifthecontrollerisconnectedtoapowersourceandan
errorisdetected,theLCDlightsamberregardlessofwhether
thecontrolleristurnedonoroff.

Dell Compellent

Chapter 1 Introduction

Item Name

Icon Description

vFlashmediacard
slot

NotusedfortheSC8000.

USBconnectors(2)

AllowsyoutoconnectUSBdevicestothecontroller.Theports
areUSB2.0compliant.

ESTpanel

Aslideoutpanelcontaininganinformationtagthatlists
systeminformationincludingtheExpressServiceTag,
embeddedNICport1MACaddress,andiDRAC7Enterprise
cardMACaddress.

SC8000 LCD Panel Features


TheLCDpanelprovidescontrollerinformation,statusmessages,anderrormessagesto
indicatewhenthecontrollerisoperatingcorrectlyorwhenitneedsattention.

TheLCDbacklightlightsblueduringnormaloperatingconditionsandlightsamberto
indicateanerrorcondition.

TheLCDbacklightremainsoffifLCDmessagingisturnedoffthroughtheiDRAC,the
LCDpanel,orothertools.

Figure 5. LCD Panel Features


Item Button

Description

Left

Movesthecursorbackinonestepincrements.

Select

Selectsthemenuitemhighlightedbythecursor.

Right

Movesthecursorforwardinonestepincrements.
Duringmessagescrolling:
Pressoncetoincreasescrollingspeed
Pressagaintostop
Pressagaintoreturntodefaultscrollingspeed
Pressagaintorepeatthecycle

Home Screen
TheHomescreendisplaysuserconfigurableinformationaboutthecontroller.Thisscreen
isdisplayedduringnormaloperationwhentherearenostatusmessagesorerrors.
TonavigatetotheHomescreenfromanothermenu,continuetoselecttheuparrow
untiltheHomeicon isdisplayed,andthenselecttheHomeicon.

FromtheHomescreen,presstheSelectbuttontoenterthemainmenu.

Storage Center SC8000 Controller Deployment Guide

SC8000 Controller

Setup Menu
TheSetupmenudisplaysuserconfigurabledefaultsforiDRAC,LCDerrormessages,and
theHomescreen.
Note: WhenyouselectanoptionintheSetupmenu,youmustconfirmtheoption
beforeproceedingtothenextaction.
Option

Description

iDRAC

SelectDHCPorStaticIPtoconfigurethenetworkmode.IfStaticIPisselected,the
availablefieldsareIP,Subnet(Sub),andGateway(Gtw).SelectSetupDNSto
enableDNSandtoviewdomainaddresses.TwoseparateDNSentriesareavailable.

Seterror

SelectSELtodisplayLCDerrormessagesinaformthatmatchesthedescriptionin
theSystemEventLog.ThisisusefulwhentryingtomatchanLCDmessagewitha
SystemEventLogentry.
SelectSimpletodisplayLCDerrormessagesinasimplifieduserfriendly
description.SeeSC8000ServiceGuideforalistofmessagesinthisformat.

Sethome

SelectthedefaultinformationdisplayontheLCDHomescreen.SeeViewMenuto
seetheoptionsandoptionitemsthatcanbesetasthedefaultontheHomescreen.

View Menu
TheSetupmenudisplaysiDRAC,asset,power,andtemperatureinformation.
Note: WhenyouselectanoptionintheViewmenu,youmustconfirmtheoption
beforeproceedingtothenextaction.

Dell Compellent

Option

Description

iDRACIP

DisplaystheIPv4orIPv6addressesfortheiDRAC7.AddressesincludeDNS
(PrimaryandSecondary),Gateway,IP,andSubnet(IPv6doesnothaveSubnet).

MAC

DisplaystheMACaddressesforiDRAC,iSCSI,orNetworkdevices.

Name

DisplaysthenameoftheHost,Model,orUserStringforthecontroller.

Number

DisplaystheAssettagortheServiceTagforthecontroller.

Power

DisplaysthepoweroutputofthecontrollerinBTU/hrorWatts.Thedisplayformat
canbeconfiguredintheSethomesubmenuoftheSetupmenu.

Temperature

DisplaysthetemperatureofthecontrollerinCelsiusorFahrenheit.Thedisplay
formatcanbeconfiguredintheSethomesubmenuoftheSetupmenu.

Chapter 1 Introduction

SC8000 Back-Panel Features and Indicators


ThebackpanelofthecontrollercontainsIOcardslots,asystemidentificationbutton,
connectors,andpowersupplies.
IO card

IO card

IO card

IO card

IO card

cache card

IO card
1
3
IPC
1

2 3

0 2
MGMT

Figure 6. SC8000 Controller Back View


Item

Name

Icon Description

Slots13

LowprofileIOcard
slots

Portsarenumberedbeginningwithport1ontheleft.

Slots46

FullheightIOcard
slots

Portsarenumberedbeginningwithport1ontheright.

Slot7

Cachecardslot

Hoststhecachecard.

System
identification
button

Usedtolocateaparticularcontrollerwithinarack.Whena
SystemIDbuttononthefrontorbackpanelispressed,the
frontLCDpanelandthebacksystemstatusindicatorflash
untiloneofthebuttonsispressedagain.
PresstotogglethesystemIDonandoff.
IfthecontrollerstopsrespondingduringPOST,press
andholdthesystemIDbuttonformorethanfive
secondstoenterBIOSprogressmode.

System
identification
connector

Connectstheoptionalsystemstatusindicatorassembly
throughtheoptionalcablemanagementarm.

iDRAC

ConnectstotheEthernetswitchintherack.

Serialport

Allowsyoutoconnecttothecontrollerusingaserial
interface.

Videoconnector

AllowsyoutoconnectaVGAmonitortothecontroller.

USBconnectors

AllowsyoutoconnectUSBdevicestothecontroller.The
portsareUSB2.0compliant.

Embedded
Ethernetconnectors

ConnectsthecontrollertotheEthernetswitchandtoother
controllersintherack.Theportsfunctionasfollows:
Port1:ETH110GbEcapable,configuredfor1GbE
(ConnecttosecondcontrollerforIPC).
Port0:ETH01GbE(ConnectstotheEthernetswitchfor
systemlogin,email,alerts,SNMPtraps,PhoneHome
data,andaccessforsoftware).
Note: Ports2and3arenotused.

10

PowerSupply1

PowerSupply2

Hotswappable,750WAC
100240VAC,autoranging,50/60Hz.

Storage Center SC8000 Controller Deployment Guide

SC8000 Controller

NIC Indicator Codes


TheembeddedEthernetconnectorsincludestatusindicators.

Figure 7. NIC Indicator


Item Name

Indicator Code

Off:TheNICisnotconnectedtothenetwork.

Linkindicator

Green:TheNICisconnectedtoavalidnetworkatitsmaximumport
speed(1Gbpsor10Gbps).
Amber:TheNICisconnectedtoavalidnetworkatlessthanits
maximumportspeed.
2

Activity
indicator

Flashing:Indicatestransmit/receiveactivity.
Steady:Indicatesvalidnetworkconnection.

Power Indicator Codes


EachACpowersupplyhasanilluminatedtranslucenthandle.

Figure 8. AC Power Supply Status Indicator


Item Name
1

ACpower
supplystatus
indicator/
handle

Indicator Code
Notlit:Powerisnotconnected.
Green:Avalidpowersourceisconnectedtothepowersupplyandthe
powersupplyisoperational.
Flashingamber:Indicatesaproblemwiththepowersupply.
Flashinggreen:Whenhotaddingapowersupply,thisindicatesthat
thepowersupplyismismatchedwiththeotherpowersupply(interms
ofefficiency,featureset,systemstatus,orsupportedvoltage).Replace
thepowersupplythathastheflashingindicatorwithapowersupply
thatmatchesthecapacityoftheotherinstalledpowersupply.

Dell Compellent

11

Chapter 1 Introduction

Caution: Thepowersuppliesmustbeofthesameinputtypeandhavethesame
maximumoutputpower.Mismatchedpowersuppliesresultinanerrorcondition.
Caution: ACpowersuppliessupportboth220Vand110Vinputvoltages.When
twoidenticalpowersuppliesreceivedifferentinputvoltages,theycanoutput
differentwattagesandtriggeramismatch.
Caution: Whencorrectingapowersupplymismatch,replaceonlythepower
supplywiththeflashingindicator.Swappingtheoppositepowersupplytomakea
matchedpaircanresultinanerrorconditionandunexpectedcontrollershutdown.

SC280 SAS Enclosures


SASenclosuresholddrivesfordatastorageandconnecttothecontrollersthrough
backendports.TheStorageCenterSC280isa5Usize6GBSASenclosure.TheSC280
enclosuresupportsupto84harddrivesinstalledintwodrawersof42driveseach.The
SC280enclosuresalsocontaintwopowersupplyunits,fivecoolingfanmodules,andtwo
redundantenclosuremanagementmodules(EMMs).
ThefollowingrequirementsapplytoSC280enclosures:

12

SC280enclosurescannotbeconnectedtothesamechainasanyotherenclosures.

EachchainsupportsamaximumoftwoSC280enclosures.

ASASIOcardcansupportmixedchains(forexample,achainofSC280enclosures,and
achainofSC200enclosures),howevertheenclosuresmustallbe6GB.

ControllersmustberunningStorageCenterOS6.4.1orlatertodetectSC280enclosures.

Storage Center SC8000 Controller Deployment Guide

SC280 SAS Enclosures

SC280 Enclosure Front Panel Features and Indicators


Theoverallenclosurestatusisshownonapanellocatedontheleftsideoftheenclosure.

3
4
5
6
7

Figure 9. SC280 Enclosure Front Panel Features and Indicators


Item

Feature/Indicator

Icon

Description

UnitIDdisplay

Anumericaldisplayoftheenclosureunit
identificationnumber.ThisnumberissetbyStorage
Center.

Inputswitch

Notcurrentlyused(thoughitcanbeusedtosetthe
UnitIDDisplay,theIDisautomaticallyresetbythe
StorageCenter).

Systempowerindicator

Amber:Enclosureisinstandby(notoperational).
Green:Enclosureison(operational).

Dell Compellent

Modulefault

Amber:Hardwarefault(PCMfault,Fanfault,SSB
modulefault.Checkindicatorsonindividual
modules).

Logicalstatusindicator

Amber:changeofstatusorfaultfromsomethingother
thantheenclosureitself(thismaybefromaninternal
orexternalRAIDcontrollerorHBA,butisusually
associatedwithadiskdriveasindicatedbyitsown
faultLED).

DrawerFault1

Amber:drive,cable,orsideplanefaulthasoccurredin
drawer1.

DrawerFault2

Amber:drive,cable,orsideplanefaulthasoccurredin
drawer2.

13

Chapter 1 Introduction

SC280 Drawer Front-Panel Features and Indicators


EachsideofeachdrawershowsstatususingLEDindicators.

1
2
3
4

Figure 10. SC280 Drawer Front Panel Features and Indicators


Item

Feature/Indicator

SideplaneOK/Power

Icon

Description
Off:Sideplanecardorcablefault.
Green:Sideplanecardandcablearefunctional.

DrawerFault

Amber:Sideplanecardfaultordrivefailurecausing
lossofavailabilityorredundancy.

Logicalfaultindicator

Amber:Hostindicateddrivefault.
FlashingAmber:Array(s)inimpactedstate.

14

CableFault

Amber:Cablefault.

ActivityBarGraph

SixvariableintensityLEDsdynamicallydisplaydrive
accessintheenclosuredrawer.

Storage Center SC8000 Controller Deployment Guide

SC280 SAS Enclosures

SC280 Back-Panel Features and Indicators


Theenclosurebackpanelprovidescontrolstopowerupandresettheenclosure,indicators
toshowtheenclosurestatus,andconnectionsforbackendcabling.
1
2

4
5
6

Figure 11. SC280 Back Panel Identification

Dell Compellent

Item

Name

Optionalcableretentionpositions(4).

IOenclosuremanagementmodules(2).SeeSC280EMMFeaturesandIndicatorson
page 16.

Fanmodules(5).

Powersupplyunits(2).SeeSC280PowerSupplyUnitFeaturesandIndicatorsonpage 17.

Powerswitches(2).

Optionalcableretentionpositions(2).

15

Chapter 1 Introduction

SC280 EMM Features and Indicators


SC280enclosuresincludetwoEnclosureManagementModules(EMM)intwointerface
slots.EachEMMIOModuleincludesanEEPROMthatholdsdatadescribingthefunction
andcapabilityoftheEMMmodule.EachEMMmodulecandiscoverthetypeand
capabilitiesofitspartnerEMMmodulewithintheenclosure.Incompatibleconfigurations
resultinanenclosuresystemalarm.
Eachporthasfourseparatelyarbitratedphysicallanes.AgreenLEDindicatesthestatusof
eachlane.TheIOModuleandFaultindicatorsprovidestatusasdescribedbelow.
1

Figure 12. IO Module Indicators


Item Name
1

Icon

Powerindicator

Description
Green(steady):ModuleOK.
Green(flashing):Vitalproductdata(VPD)fault.
Off:Modulefault.

IOModulefault
indicator

Amber:IOmoduleerror.

Console

LaneLEDs

Factoryuseonly.
SolidGreen:Connected,Noactivity.
Flashing:Activity.

16

SASportA(in)

Connectstootherenclosures.

SASportB(out)

Connectstootherenclosures.

SASPortC

TheCportalwaysconnectstothecontroller.

Storage Center SC8000 Controller Deployment Guide

SC280 SAS Enclosures

SC280 Power Supply Unit Features and Indicators


SC280enclosuresincludetwoPowerSupplyUnits(PSUs)intwointerfaceslots.

Figure 13. SC280 PSU Features and Indicators

Item

Name

Releaselatch

PSUfaultindicator

Icon Description

Amber(steady)PSUfault,PSUnotsupplying
power
Amber(flashing)PSUfirmwareisdownloading

ACpowerindicator

Amber(steady)ACpowerisnotdetected
Amber(flashing)PSUfirmwareisdownloading

PowerOKindicator

Green(steady)ThisPSUisprovidingpower
Green(flashing)ACpowerispresent,butthis
PSUisinstandbymode(theotherPSUisproviding
power)

Powerswitch

Controlspowerfortheenclosure.

SeparateanduniqueconditionsareindicatedifallthreeLEDsareinthesamestate:

Dell Compellent

IfallthreeLEDsareoff,thenthereisnoACpowertoeitherPSU.

IfallthreeLEDsareon,thentheGeneralEnclosureManagement(GEM)softwarehas
lostcommunicationwiththePSU.

17

Chapter 1 Introduction

Fan Module Features and Indicators


SC280enclosuresincludefivefanmodulesinfiveinterfaceslots.

2
3
4

Figure 14. SC280 Fan Module Features and Indicators

18

Item

Control/Feature

Icon Description

Releaselatch

ModuleOK

GreenModuleOK

Batteryfault

Notcurrentlyused

Fanfault

AmberLossofcommunicationwiththefanmodule,
orreportedfanspeedisoutoftolerance

Storage Center SC8000 Controller Deployment Guide

SC280 SAS Enclosures

SC280 Enterprise Plus Drives


EnterprisePlusDrivescanonlybeinstalledinSC280enclosures.Anindicatorgivesstatus
andactivityinformationasdescribedbelow.

Figure 15. SC280 Hard Drive Indicators


Item Name
1

Indicator Code

Harddriveactivityindicator SteadyAmberDrivefault
FlashingAmber(on1sec/off1sec)Driveorenclosure
indicatorissettoOninSystemManager.(Withthedrive
indicator,thecontainingdrawerfaultLEDalsoflashes;
withtheenclosureindicator,alldrivesandbothdrawers
faultLEDsflash.)

Dell Compellent

19

Chapter 1 Introduction

SC280 Drive Numbering


SC280drivesarelocatedintwodrawers,eachcontainingthreerowsofdrives.Thedrives
arenumbered142indrawer1,fromfronttobackandlefttoright,and4384indrawer2.

Figure 16. Hard Drive Numbering

SC200/220 SAS Enclosures


SASenclosuresholddrivesfordatastorageandconnecttothecontrollersthrough
backendports.TheStorageCenterSC200andSC220are2UsizeSASenclosures.The
SC200enclosuresupportsupto123.5inchharddrivesinstalledinafourcolumn,three
rowconfiguration.TheSC220enclosuresupportsupto242.5inchharddrivesinstalled
verticallysidebyside.TheSC200andSC220enclosuresshipwithtwopowersupply/
coolingfanmodulesandtworedundantenclosuremanagementmodules(EMMs).
ThefollowingrequirementsapplytoSC200andSC220enclosures:

20

SC200andSC220enclosurescannotbeconnectedtothesamechainasanyother
enclosures.

ControllersmustberunningStorageCenterOS6.2orlatertodetectSC200andSC220
enclosures.

Storage Center SC8000 Controller Deployment Guide

SC200/220 SAS Enclosures

SC200/220 Front-Panel Features and Indicators


Thefrontpanelshowstheenclosureandpowerstatus.
1
2

Figure 17. SC200 Front Panel Features and Indicators

1
2

Figure 18. SC220 Front Panel Features and Indicators


Item Name
1

Icon Description

Enclosurestatus
indicator

Lightswhentheenclosurepowerison.
Off:Nopower.
Onsteadyblue:Normaloperation.
Flashingblue:IndicatesthatStorageCenterisidentifying
theenclosure.
Onsteadyamber:Enclosureisturningonorwasreset.
Flashingamber:Enclosureisinthefaultstate.

Powerstatus
indicator

Lightswhenatleastonepowersupplyissupplyingpowerto
theenclosure.
Off:Bothpowersuppliesareoff.
Onsteadygreen:Atleastonepowersupplyisproviding
powertotheenclosure.

Harddrives

SC200:Upto123.5inchharddrives.
SC220:Upto242.5inchharddrives.

Dell Compellent

21

Chapter 1 Introduction

SC200/220 Back-Panel Features and Indicators


Theenclosurebackpanelprovidescontrolstopowerupandresettheenclosure,indicators
toshowtheenclosurestatus,andconnectionsforbackendcabling.
1
2
3

Compellent SC2

Compellent SC2

Figure 19. SC200/SC220 Back Panel Features and Indicators


Item

Name

DCpowerindicator

Icon Description
Green:Normaloperation.Thepowersupply
moduleissupplyingDCpowertotheenclosure.
Off:Powerswitchisoff,thepowersupplyisnot
connectedtoACpower,orthereisafaultcondition

Powersupply/cooling
fanindicator

Amber:Powersupply/coolingfanfaultisdetected

ACpowerindicator

Green:Powersupplymoduleisconnectedtoa
sourceofACpower,whetherthepowerswitchison

Off:Normaloperation

Off:Powersupplymoduleisdisconnectedfroma
sourceofACpower

22

Powerswitches(2)

Controlspowerfortheenclosure.Thereisoneswitch
foreachpowersupply/coolingfanmodule.

Powersupply/cooling
fanmodules(2)

Containsa700Wpowersupplyandfansthatprovide
coolingfortheenclosure

EnclosureManagement
Modules(2)

EMMsprovidethedatapathandenclosure
managementfunctionsfortheenclosure

Storage Center SC8000 Controller Deployment Guide

SC200/220 SAS Enclosures

SC200/220 EMM Features and Indicators


SC200andSC220enclosuresincludetwoEnclosureManagementModule(EMM)IO
modulesintwointerfaceslots.
Compellent SC2

Figure 20. SC200/SC220 EMM Features and Indicators


Item Name

Icon

Description

Systemstatusindicator

NotusedonSC200/220enclosures

Debugport

Forengineeringuseonly

SASportA(in)

Connectstothecontrollerortootherenclosures.SASports
AandBcanbeusedforeitherinputoroutput,howeverfor
cablingconsistency,useportAasaninputport.

PortAlinkstatus

Green:Allthelinkstotheportareconnected
Amber:Oneormorelinksarenotconnected
Off:Enclosureisnotconnected

SASportB(out)

Connectstothecontrollerortootherenclosures.SASports
AandBcanbeusedforeitherinputoroutput,howeverfor
cablingconsistency,useportBasanoutputport.

PortBlinkstatus

Green:Allthelinkstotheportareconnected
Amber:Oneormorelinksarenotconnected
Off:Enclosureisnotconnected

EMMstatusindicator

SteadyGreen:Normaloperation
Amber:Enclosuredidnotbootorisnotproperly
configured
FlashingGreen:Automaticupdateinprocess
FlashingAmberTwice:Enclosureisunableto
communicatewithotherenclosures
FlashingAmberFourTimes:Firmwareupdatefailed
FlashingAmberFiveTimes:Firmwareversionsare
differentbetweenthetwoEMMs

Dell Compellent

23

Chapter 1 Introduction

SC200/220 Enterprise Plus Drives


EnterprisePlusDrivescanonlybeinstalledinSC200/220enclosures.Drivesareinstalled
eithervertically(SC220)orhorizontally(SC200)intheenclosure.Indicatorsgivestatusand
activityinformationasdescribedbelow.
2
1

Figure 21. SC200 Hard Drive Indicators


1 2

Figure 22. SC220 Hard Drive Indicators


Item Name
1

Indicator Code

Harddriveactivityindicator Flashinggreen:Indicatesdriveactivity
Steadygreen:Indicatesnodriveactivity

Harddrivestatusindicator

Steadygreen:Normaloperation
Flashinggreen(on1sec/off1sec):Driveorenclosure
indicatorissettoOninSystemManager.(Withthe
enclosureindicator,alldrivesfaultLEDsflash.)
Off:Nopowertothedrive

24

Storage Center SC8000 Controller Deployment Guide

SC200/220 SAS Enclosures

SC200/220 Drive Numbering


InSC200andSC220enclosures,drivesarenumberedfromlefttorightstartingfrom0.
StorageCenteridentifiesdrivesasDisk-XXYY,whereXXisthenumberoftheenclosure
thatphysicallycontainsthedrive,andYYisthedrivepositioninsidetheenclosure.

SC200:Drivesarenumberedinrowsstartingfrom0atthetopleftdrive.
Drive 0

Drive 1

Drive 2

Drive 3

Drive 4

Drive 5

Drive 6

Drive 7

Drive 8

Drive 9

Drive 10

Drive 11

Figure 23. SC200 Enclosure Drive Numbering

SC220:Drivesarenumberedstartingfrom0attheleftmostdrive.
0

2 3 4 5

6 7

8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Figure 24. SC220 Enclosure Drive Numbering

Dell Compellent

25

Chapter 1 Introduction

EN-SASx6x12/24 Enclosures
SASenclosuresholddrivesfordatastorageandconnecttothecontrollersthrough
backendports.ENSASX6X12enclosurescanholdupto123.5drives,andENSASX6X24
canholdupto242.5drives.
ENSASx6x12/24enclosurescannotbeconnectedtothesamechainasSC200orSC220
enclosures.

EN-SASx6x12/24 Front-Panel Features and Indicators


Theenclosurefrontpanelprovidescontrolstopowerupandresettheenclosureand
indicatorstoshowtheenclosurestatus.InserttheenclosureintoaracksothattheLED
displayisontheleftside.
1

EN-SASX6X12 Enclosure

5
EN-SASX6X24 Enclosure

Figure 25. SAS Enclosures Front View Controls and Indicators


Item Name

Icon

Description

Mutebutton

Mutesthealarm

Systempowerindicator

Green:Powerison
Amber:Unitisonstandby

Modulefaultindicator

Amber:Enclosuremodulefailure(PCMfault,Fanfault,
SSBmodulefault.Checkindicatorsonindividual
modules)

Logicalfaultindicator

Amber:Drivefailure
FlashingAmber:UnexpectedenclosureID(Module
Faultalsoflashesamber)

26

LEDdisplay

IndicatestheenclosureIDnumberthesoftwaresetsthis
numberduringinstallation,andmatchestheDiskID
displayedintheStorageCenterSystemManager

Storage Center SC8000 Controller Deployment Guide

EN-SASx6x12/24 Enclosures

EN-SASx6x12/24 Back-Panel Features and Indicators


Theenclosurebackpanelprovidescontrolstopowerupandresettheenclosure,indicators
toshowtheenclosurestatus,andconnectionsforbackendcabling.

Figure 26. SAS Enclosure Rear View Controls and Indicators


Item Name
1

Icon

ACpowerindicator

Description
Green:Normaloperation
Amber:NoACpower

Fanindicator

Green:Normaloperation
Amber:Fanfailure

PCMstatusindicator

Green:Normaloperation
Amber:Powersupplyfailure

DCpowerindicator

Green:Normaloperation
Amber:NoDCpower

Dell Compellent

Powerswitch

Controlspowerfortheenclosure

PowerCoolingModule(PCM)oneof
two

Containsfansthatprovidecoolingfor
theenclosure

StorageBridgeBay(SBB)oneoftwo

SeeENSASx6x12/24SBBModule
FeaturesandIndicatorsonpage 28

27

Chapter 1 Introduction

EN-SASx6x12/24 SBB Module Features and Indicators


SASenclosuresincludetwoStorageBridgeBay(SBB)IOmodulesintwoSBBcompliant
interfaceslots.EachSBBIOModuleincludesanEEPROMthatholdsdatadescribingthe
functionandcapabilityoftheSBBmodule.EachSBBmodulecandiscoverthetypeand
capabilitiesofitspartnerSBBmodulewithintheenclosure.Incompatibleconfigurations
resultinanenclosuresystemalarm.
Eachporthasfourseparatelyarbitratedphysicallanes.AgreenLEDindicatesthestatusof
eachlane.TheIOModuleandFaultindicatorsprovidestatusasdescribedbelow.
1

Figure 27. IO Module Indicators


Item Name

Icon

Description

IOModuleindicator

OnSteady:Normaloperation

IOModulefault
indicator

On:IOmoduleerror

SASportA(in)

Connectstootherenclosures

LaneLEDs

SolidGreen:Connected,Noactivity
Flashing:Activity

28

SASportB(out)

Connectstootherenclosures

SASPortC

TheCportalwaysconnectstothecontroller.

Storage Center SC8000 Controller Deployment Guide

EN-SASx6x12/24 Enclosures

EN-SASx6x12/24 Standard SAS Drives


StandardSASdrivescanonlybeinstalledinENSASx6x12/24enclosures.Drivesare
installedeitherverticallyorhorizontallyintheenclosure.Indicatorsgivestatusand
activityinformationasdescribedbelow.
3

Figure 28. EN-SASx6x12 Standard SAS Drive Indicators

Figure 29. EN-SASx6x24 Standard SAS Drive Indicators


Item Name
1

AmberLED

Description
Off:Nodrive,ordriveisoperating
On:Drivefault
Flashing(on1sec/off1sec):Driveorenclosure
indicatorissettoOninSystemManager.

GreenLED

Green:Connected,Noactivity
Flashing:Activity

Dell Compellent

AntitamperIndicator(when
present)

Red:Locked

Lock(whenpresent)

InsertkeyorT10Torxdriverandturntolock/unlock

Black:Unlocked

29

Chapter 1 Introduction

EN-SASx6x12/24 Drive Numbering


InENSASX6X12andENSASX6X24enclosures,drivesarenumberedfromlefttoright
startingfrom1.StorageCenteridentifiesdrivesasDisk-XXYY,whereXXisthenumberof
theenclosurethatphysicallycontainsthedrive,andYYisthedrivepositioninsidethe
enclosure.

ENSASX6X12:Drivesarenumberedinrowsstartingfrom1atthetopleftdrive.
Drive 1

Drive 2

Drive 3

Drive 4

Drive 5

Drive 6

Drive 7

Drive 8

Drive 9

Drive 10

Drive 11

Drive 12

Figure 30. EN-SASx6x12 Enclosure Drive Numbering

ENSASX6X24:Drivesarenumberedstartingfrom1attheleftmostdrive.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Figure 31. EN-SASx6x24 Enclosure Drive Numbering

30

Storage Center SC8000 Controller Deployment Guide

Install the Hardware


Verifythattheorderedequipmentarrivedsafely,installIOcardsinthecontroller(s),disks
intheenclosures(asrequired)andmounttheequipmentinarack.

Contents
PrepareforInstallation ....................................................... 31
SafetyPrecautions ........................................................... 32
InstallIOCardstheController(s) .............................................. 35
LabeltheControllers ......................................................... 44
MounttheHardwareinaRack ................................................ 45
InstallDrivesinSC280Enclosures ............................................. 48
InstallDrivesinENSASx6x12/24Enclosures .................................... 50
InstallEnterprisePlusDrivesinSC200/220Enclosures ........................... 53

Prepare for Installation


Beforeyoubegin,makesurethatthecorrectequipmentisavailable,theinstallation
environmentisready,andyouhavethenecessarymaterials.

Unpack and Inventory the Storage Center Equipment


Makesuretheequipmentthatwasorderedarrivedsafelyonsite:

Controllers

Enclosuresanddrives

IOcards

Frontendcables

Backendcables

Switches

Prepare the Installation Environment


Makesurethattheenvironmentisreadyforinstallation.

Dell Compellent

RackSpace:TheremustbesufficientspaceintheracktoaccommodatetheStorage
Centercontroller(s),enclosures,andswitches.

Power:Powermustbeavailableintherack,andthepowerdeliverysystemmustmeet
thepowerrequirementsfortheStorageCenter.

31

Chapter 2 Install the Hardware

Connectivity:Therackmustbewiredforconnectivitytothemanagementnetworkand
anynetworksthatcarryfrontendIOfromtheStorageCentertoservers.

Gather Required Materials


Makesurethatyouhavethefollowingitemsbeforeyoubegintheinstallation.
Required Item

Description

StorageCenterlicensefile

Makessettingsavailabledependingonwhatfeatureswere
purchased.

RS232serialcableandPCor Usedtoruncommandsandviewconsolemessagesduring
laptop
controllerconfiguration.
Computerconnectedtothe UsedtoconnecttotheStorageCenterSystemManager(througha
samenetworkastheStorage webbrowser)tocompletetheStorageCenterconfiguration.
Center
HardwareSerialNumber
(HSN)andSystemSerial
Number(SSN)

Usedtoconfigurethecontroller(s).

StorageArchitectorBusiness (Optional)Providesitespecificsettingsusedduringdeployment:
Partnersuppliedpre
Listofhardwareneededtosupportstoragerequirements
installationdocument(s)
Optionalconnectivitydiagramstoillustratecablingbetweenthe
controllers,enclosures,switches,andservers
Optionalnetworkinformation,suchasIPaddresses,subnet
masks,gateways
StorageCenterMaintenance (Optional)UsedtoupdatetheStorageCenterOSwheninternet
CD
accessisnotavailable.

Safety Precautions
Toavoidinjuryanddamagetotheequipment,alwaysfollowthesesafetyprecautions.
IfequipmentdescribedinthedocumentisusedinamannernotspecifiedbyDell
Compellent,theprotectionprovidedbytheequipmentmaybeimpaired.Foryoursafety
andprotection,observethefollowingrules:
Note: SeethesafetyandregulatoryinformationthatshippedwitheachStorage
Centercomponent.Warrantyinformationmaybeincludedwithinthisdocumentor
asaseparatedocument.

Electrical Safety Precautions


Alwaysfollowelectricalsafetyprecautionstoavoidinjuryanddamagetotheequipment.

32

Provideasuitablepowersourcewithelectricaloverloadprotection.Allcomponentsin
theStorageCentermustbegroundedbeforeapplyingpower.Makesurethatthereisa
safeelectricalearthconnectiontopowersupplycords.Checkthegroundingbefore
applyingpower.

Theplugsonthepowersupplycordsareusedasthemaindisconnectdevice.Makesure
thatthesocketoutletsarelocatedneartheequipmentandareeasilyaccessible.

Knowthelocationsoftheequipmentpowerswitchesandtheroomsemergencypower
offswitch,disconnectionswitch,orelectricaloutlet.

Storage Center SC8000 Controller Deployment Guide

Safety Precautions

Donotworkalonewhenworkingwithhighvoltagecomponents.

Donotusematsdesignedtodecreaseelectrostaticdischargeasprotectionfrom
electricalshock.Instead,userubbermatsthathavebeenspecificallydesignedas
electricalinsulators.

DonotremovecoversfromthePowerControlModule(PCM).Disconnectthepower
connectionbeforeremovingaPCMfromtheenclosure.

DonotremoveafaultyPCMunlessyouhaveareplacementmodelofthecorrecttype
readyforinsertion.AfaultyPCMmustbereplacedwithafullyoperationalmodule
within24hours.

Permanentlyunplugtheenclosurebeforeyoumoveitorifyouthinkithasbecome
damagedinanyway.WhenpoweredbymultipleACsources,disconnectallsupply
powerforcompleteisolation.
Warning: Disconnectpowerfromthecontrollerwhenremovingorinstalling
componentsthatarenothotswappable.Whendisconnectingpower,firstpower
downthecontrollerusingtheStorageCenterSystemManagerandthenunplugthe
powercordsfromallthepowersupplymodulesinthecontroller.

General Safety Precautions


Toavoidinjuryanddamagetotheequipment,alwaysfollowgeneralsafetyprecautions.

Keeptheareaaroundthechassiscleanandfreeofclutter.

Placethechassiscoverandanysystemcomponentsthathavebeenremovedawayfrom
thecontrolleroronatablesothattheyarenotinthewayoffoottraffic.

Whileworkingonthecontroller,donotwearlooseclothingsuchasnecktiesand
unbuttonedshirtsleeves,whichcancomeintocontactwithelectricalcircuitsorbe
pulledintoacoolingfan.

Removeanyjewelryormetalobjectsfromyourbodybecausetheyareexcellentmetal
conductorsthatcancreateshortcircuitsandharmyouiftheycomeintocontactwith
printedcircuitboardsorareaswherepowerispresent.

DonotliftanenclosurebythehandlesofthePowerCoolingModules(PCMs).Theyare
notdesignedtoholdtheweightoftheentireenclosure,andtheenclosurecovermay
becomebent.

Beforemovinganenclosure,removethePCMstominimizeweight.

Inordertocomplywithapplicablesafety,emission,andthermalrequirements,donot
removebaycoversfromenclosures.Makesurethatallbaysarepopulatedwithplugin
modules.

Donotremovebaycoversordrivesuntilreadytoreplacethem.
Warning: Toavoidinjury,donotattempttotheliftacontrollerorenclosureby
yourself.Alwaysgetassistancewhenliftingthecontroller.
Caution: Donotoperatethecontrollerwithoutthecover,exceptwhenreplacing
coolingfans.
Warning: Thememorymodulesmaybehotforseveralminutesafterthecontroller
hasbeenpowereddown.Waitforthememorymodulestocoolbeforehandling
them.

Dell Compellent

33

Chapter 2 Install the Hardware

Caution: Toensurepropercontrollercooling,memorymoduleblanksmustbe
installedinanymemorysocketthatisnotoccupied.
Warning: Topreventeyedamage,donotstareintothelaserbeamapertureofan
SFP+transceiver.

Electrostatic Discharge Precautions


Toavoidinjuryanddamagetotheequipment,alwaysfollowelectrostaticdischarge(ESD)
precautionst
Electrostaticdischarge(ESD)isgeneratedbytwoobjectswithdifferentelectricalcharges
comingintocontactwitheachother.Theresultingelectricaldischargecandamage
electroniccomponentsandprintedcircuitboards.Followtheseguidelinestoprotectyour
equipmentfromESD:

34

Itisrecommendedthatyoualwaysuseastaticmatandstaticstrapwhileworkingon
componentsintheinteriorofthecontroller.

ObserveallconventionalESDprecautionswhenhandlingpluginmodulesand
components.

UseasuitableESDwristoranklestrap.

Avoidcontactwithbackplanecomponentsandmoduleconnectors.

Keepallcomponentsandprintedcircuitboards(PCBs)intheirantistaticbagsuntil
readyforuse.

Storage Center SC8000 Controller Deployment Guide

Install IO Cards the Controller(s)

Install IO Cards the Controller(s)


Beforeyoumountthecontroller(s)inarack,installtheIOcards.

Open the Cover


Openthecovertogainaccesstotheinsideofthecontroller.
Caution: Donotoperatethecontrollerwithoutthecover,exceptwhenreplacing
coolingfans.
Caution: Donotslidethecontrollerintoarackwiththecoveropen.Riser 2
containsachassisintrusiondetectionswitchthatcanbeeasilydamagedwhen
slidingacontrollerintotherackwiththecoveropen.
1 Rotatethelatchreleaselockcounterclockwisetotheunlockedposition.
2 Liftthelatchontopofthecontrollerandslidethecoverback.
3 Graspthecoveronbothsides,andcarefullyliftthecoverawayfromthecontroller.
2

Figure 32. Opening the Cover


1 Controller cover
2 Latch
3 Latch release lock

Dell Compellent

35

Chapter 2 Install the Hardware

Remove the Cooling Shroud


Removethecoolingshroudtogainaccesstothememorysockets.
1 Holdontothetwotouchpointsofthecoolingshroud.
2 Liftthecoolingshroudawayfromthecontroller.
2
1

Figure 33. Removing and Inserting the Cooling Shroud


1 Cooling shroud
2 Touch points

Insert the Cooling Shroud


Usethisproceduretoinstallthecoolingshroud.
1 Alignthetabsonthecoolingshroudwiththesecuringslotsonthechassis.
2 Lowerthecoolingshroudintothechassisuntilitisfirmlyseated.
Note: Forproperseatingofthecoolingshroudinthechassis,ensurethatthe
cablesinsidethecontrollerareroutedalongthechassiswallandsecuredusing
thecablesecuringbracket.

36

Storage Center SC8000 Controller Deployment Guide

Install IO Cards the Controller(s)

Install IO Cards
InstalltheIOcardsinthecontroller(s)basedontheIOcardpriorityrules.Fordual
controllersystems,installIOcardsinthesamelocationsinbothcontrollers.

Determine Where IO Cards Should Be Installed


ThefollowingtableprovidesguidelinesforinstallingIOcardstoensurepropercooling
andmechanicalfit.InstallIOcardsusingthecardpriorityandslotpriorityorderindicated.
Populatetheslotsasfollows:

InstalllowprofileIOcardsinslots3through1.Afterfillingtheseslots,lowprofile
cardsmaybeinstalledinslots4,5,and6whenusedwiththeadaptivebracket.

InstallfullheightIOcardsbeginninginslot6,followedbyslot5,thenslot4ifneeded.

Slot7isreservedfortheCacheCard.
Note: LowprofileIOcardsareshippedwithanadaptivefullheightbracketthat
mustbeinstalledtousetheIOcardinaslotdesignedforafullheightIOcard.When
alowprofilecardisinstalledinafullheightslottheportsarereversed,soport
number1isontheright.
Note: TouseMultiVLANTagging(MVLAN)installaChelsio10GbiSCSIcard.
MVLANismanagedinEnterpriseManager.

Dell Compellent

Speed
(Gb)

Number
of Ports

Card
Priority

Slot
Priority

11

3,2,1,4,5

10

4,5,6

Lowprofile 1

3,2,1,4,5

LSISAS920116E

Fullheight

6,5,4

LSISAS920616E

Lowprofile 6

3,2,1,6,5,
4

FibreChannel EmulexLPe12004M8*

Fullheight

4,5,6

FibreChannel EmulexLPe12002M8*

Lowprofile 8

3,2,1,4,5

FibreChannel QLogicQLE2662

Lowprofile 16

3,2,1,4,5,
6

FibreChannel QLogicQLE2562

Lowprofile 8

3,2,1,4,5,
6

FibreChannel QLogicQLE2564

Fullheight

4,5,6

3,2,1,4,5

n/a

Type

Card

Height

iSCSI

ChelsioS320ELPCR
(SFP+transceiver
requiredforoptical
support)

Lowprofile 10

iSCSI

ChelsioS320ECR*(SFP+ Fullheight
transceiverrequiredfor
opticalsupport)

iSCSI

QLogicQLE4062

SAS
SAS

10

FCoE

QlogicQLE8152(SFP+ Lowprofile 10
transceiverrequiredfor
opticalsupport)

Cachecard

Dell

Fullheight

n/a

37

Chapter 2 Install the Hardware

*TheseIOcardscannotbeorderedforSC8000controllers.AnSC8000controllercancontaintheseIOcardsonlyiftheywere
transferredtotheSC8000controllerduringanupgradefromaCTSC030orCTSC040controller.

See Also
SC8000BackPanelFeaturesandIndicatorsonpage 10

Install Low-Profile IO Cards in Slots 13


ToinstalllowprofileIOcards,firstremoveriser1.
1 Removeriser1.
a Holdontothetouchpointsoftheriser.
b Lifttheriserfromtheriserconnectoronthesystemboard.
2
1

Table 1. Removing Riser 1

38

1 Riser 1 cage

4 Riser guide, back (left)

2 Riser 1

5 Riser 1 connector

3 Riser guide, back (right)

6 Riser guide, front

Storage Center SC8000 Controller Deployment Guide

Install IO Cards the Controller(s)

2 OpentheIOcardlatchbypressingthelatchtabandrotatingthelatchdown.
1

Figure 34. Installing an IO Card in Riser 1


1 Riser 1 cage

4 IO card latch

2 IO card connector

5 IO card latch tab

3 IO card

3 InstalleachlowprofileIOcard.
a LocatetheslotwheretheIOcardisinstalled.
2

Figure 35. Identifying Connectors on Riser 1


1 IO card slot 1
2 IO card slot 2
3 IO card slot 3

b UnpackthereplacementIOcardandprepareitforinstallation.Forinstructions,see
thedocumentationaccompanyingtheIOcard.
c

HoldingtheIOcardbyitsedges,positionthecardsothatthecardedgeconnector
alignswiththeIOcardconnectorontheriser.

d InsertthecardedgeconnectorfirmlyintotheIOcardconnectoruntilthecardis
fullyseated.
Caution: MakesurethattheIOcardisfullyseatedintheIOcardconnector.
IOcardsthatarenotinfullcontactwiththeconnectorcauseunpredictable
failuresintheStorageCenter.
e ClosetheIOcardlatch.
Dell Compellent

39

Chapter 2 Install the Hardware

4 Insertriser1.
a Aligntheriserwiththeconnectorandtheriserguides.
b Lowertheriserintoplaceuntiltheriserisfullyseatedintheconnector.
2
1

Table 2. Removing Riser 1

40

1 Riser 1 cage

4 Riser guide, back (left)

2 Riser 1

5 Riser 1 connector

3 Riser guide, back (right)

6 Riser guide, front

Storage Center SC8000 Controller Deployment Guide

Install IO Cards the Controller(s)

Install Full-Height IO Cards in Slots 46


InstallfullheightIOcardsinstalledinriser2and3.Slots4and5arelocatedinriser2,and
slot6islocatedinriser3.
1 LocatetheslotwheretheIOcardisinstalled.
2

Figure 36. Identifying Connectors on Riser 2


1 Chassis intrusion switch
2 IO card slot 4
3 IO card slot 5
1

Figure 37. Identifying Connectors on Riser 3


1 IO card slot 6
2 IO card slot 7

Dell Compellent

41

Chapter 2 Install the Hardware

2 LifttheIOcardlatchoutoftheslot.
2

1
3

Figure 38. Replacing the IO Card in Riser 2 or 3


1 IO card

3 IO card connector

2 IO card latch

4 Riser

3 UnpackthereplacementIOcardandprepareitforinstallation.Forinstructions,seethe
documentationaccompanyingtheIOcard.
4 HoldtheIOcardbyitsedgesandpositionthecardsothatthecardedgeconnector
alignswiththeIOcardconnectorontheriser.
5 InsertthecardedgeconnectorfirmlyintotheIOcardconnectoruntilthecardisfully
seated.Usethesupportsprovidedonthecoolingshroud.
Caution: MakesurethattheIOcardisfullyseatedintheIOcardconnector.IO
cardsthatarenotinfullcontactwiththeconnectorcauseunpredictablefailures
inStorageCenter.

42

Storage Center SC8000 Controller Deployment Guide

Install IO Cards the Controller(s)

Figure 39. Seating the IO Card


6 ReplacetheIOcardlatch.
7 Pressthetouchpointtoreleasethecardretentiontab(notshown)androtatethetab
untilitlocksinplaceovertheIOcard.

Close the Cover


Performthisproceduretoclosethecover.
1 Liftthelatchonthecover.
2 Placethecoverontothechassisandoffsetthecoverslightlybacksothatitclearsthe
chassishooksandlaysflushonthechassis.
3 Pushdownthelatchtomovethecoverintotheclosedposition.
4 Rotatethelatchreleaselockclockwisetosecurethecover.
2

Figure 40. Closing the Cover


1 Controller cover
2 Latch
3 Latch release lock

Dell Compellent

43

Chapter 2 Install the Hardware

Label the Controllers


Createtwolabelsforeachcontrollertofacilitateidentificationintherack.Applylabelsto
thefrontandbackofeachcontroller.

Prerequisites
Youmusthavealabelmaker,orfourblanklabelsandawritingutensil.

Steps
1 Createtwolabelsforeachcontroller.Eachlabelshouldcontainthecontrollernumber
andSystemSerialNumber(SSN).
Line Label Information

Example

Controllernumber

CONTR1orCONTR2

SystemSerialNumber

10011

2 Applytwolabelstoeachcontroller.
a Applyonelabeltothefrontofthecontrolleronthetopleftcorner.
b Applyonelabeltotherearofthecontrolleronthemiddleofthehandle.

CONTR1
10011

Figure 41. SC8000 Controller Labels

44

Storage Center SC8000 Controller Deployment Guide

Mount the Hardware in a Rack

Mount the Hardware in a Rack


DellCompellentrecommendsmountingthehardwareinaracktoensureracksafetyand
toallowforexpansion.

2U and 3U Enclosures
Install2Uand3Uenclosuresintheracktoallowforexpansionandsothattherackdoes
notbecometopheavy.Thiscanbeaccomplishedinoneoftwoconfigurations.

Installthecontrollersonthebottomoftherackandtheenclosuresabovethecontrollers.

Installthecontrollersinthemiddleoftherackandtheenclosuresaboveandbelowthe
controllers.

Steps
1 Mountthecontroller(s)inarack.Seetheinstructionsincludedwiththerailkitfor
detailedsteps.
2 Mounttheenclosure(s)intherack.Seetheinstructionsincludedwiththerailkitfor
detailedsteps.

Figure 42. Recommended Mounting Order 2U and 3U Enclosures


1 Controllers
2 Enclosures

Dell Compellent

45

Chapter 2 Install the Hardware

5U Enclosures
The5Uenclosurescanweighupto131kg(288lb)andshouldbeinstalledinthelower
portionoftheracktoensurerackstability.
Wheninstalledinarack,theSC280enclosureextends36in.fromthefrontrackpoststothe
backofthechassis.RackmodificationsmayberequiredtoavoidblockingPDUsortoallow
properstrainreliefforSAScables.ContactDellTechnicalSupportServicesifsite
preparationhasnotalreadybeendone.
Warning: AfullyconfiguredSC280enclosureweighsupto130.7kg(287.5lb).An
unpopulatedenclosureweighs62kg(137lb).Toavoidinjury,alwaysliftwithtwo
people,anduseliftingstrapswhenrequired.
Ifinstalledabovethelower20Uofarack,acustomerprovidedmechanicalliftmust
beused.

Prerequisites
Makesurethatthesitehasthefollowing:

208VpowerfromanindependentsourceorarackpowerdistributionunitwithaUPS.
(110Vpowerwillnotwork.)

A5Uspaceinthelower20Uoftherack.Iftheenclosureistobeinstalledabovethe20U
mark(notrecommended),acustomerprovidedmechanicalliftisrequired.

PowerDistributionUnit(PDU)outletsmustbetypeIEC320C19,withaminimum
outputAmperageof20Aperconnection.

Steps
MounttheSC280enclosureintotherackusingmountingrails,andoptionallysecurewith
bracketstopreventtipping.
1 Mountthecontroller(s)inarack.Seetheinstructionsincludedwiththerailkitfor
detailedsteps.
2 Mounttherailsintherackaccordingtoinstructionsincludedintherailkit.
Warning: Whenunpackingthe5Uenclosure,twopeopleusingliftstrapsare
requiredtoavoidinjury.
3 Mounttheenclosureontotherackrails,usingtwopeopletolifttheenclosureinto
position.
4 InstallHoldDownBrackets(HDBs).
a Securethefixingscrewstotherearoftheenclosure.
b SecuretheHDBstotherearoftherack.

46

Storage Center SC8000 Controller Deployment Guide

Mount the Hardware in a Rack

Figure 43. Recommended Mounting Order 5U Enclosures


1 Controllers
2 Enclosures

Dell Compellent

47

Chapter 2 Install the Hardware

Install Drives in SC280 Enclosures


TheSC280enclosuresupportsupto843.5inchharddrivesinstalledintwodrawerswithin
theenclosure.HarddrivesconnecttothebackplaneusingDiskDriveinCarrier(DDIC)
harddrivecarriers.
Caution: Iftheenclosureoperatesfortoolong(dependingonaltitude)withdrive
drawersopen,theenclosurecanoverheat,causingpotentialdrivefailureanddata
loss.Suchusemayinvalidatethewarranty.

Installing Drives
Followtheserequirementswheninstallingdrivesintheenclosure.

Anyrowwithdrivesinstalledmustbefilledentirely(14drives).

Theminimumnumberofdrivesinanenclosureis14(onerow).

Thenumberofpopulatedrowsbetweendrawersmustnotdifferbymorethanone.

Populaterowsbeginningatthefrontoftheenclosureandmovingtotherear.

Foranewinstallation,followtheserecommendationsforpopulating42driveenclosures.

14drivesintopdrawer,frontrow

14drivesinbottomdrawer,frontrow

14drivesintopdrawer,middlerow

Steps
Caution: RemovingadrivefromtheDDICcandamagetheDDIC.Donotremove
drivesfromDDICs.
1 LowertheDDICintotheslot.
2 PushandholddowntheDDICandslideittowardthebackoftheenclosureuntilthe
DDIClatchestothebackplane.
3 Afteralldrivesareinstalled,closethedrawer.
4 Whentheenclosureisturnedon,makesurethatthedriveLEDsarenotlit,indicating
normalconditions.
Caution: Whentheenclosureturnsoff,thediskscontinuetospinafterlosing
power.Toavoiddamagetothedisk,waitforthedisktostopspinning
(approximately10secondsaftershutdown)beforepullingthediskfromthe
enclosure.

48

Storage Center SC8000 Controller Deployment Guide

Install Drives in SC280 Enclosures

1
2

Figure 44. Inserting an SC280 DDIC


1 DDIC

3 Drive fault LED

2 Release button

See Also
SC280EnterprisePlusDrivesonpage 19

Dell Compellent

49

Chapter 2 Install the Hardware

Install Drives in EN-SASx6x12/24 Enclosures


IfyouareinstallingENSASx6x12and/orENSASx6x24enclosures,installdrivesinthe
enclosures.
Wheninstallingdrivesintoa12driveenclosure,makesurethatalldrivesinacolumnare
ofthesamespindlerateasshowninthefollowingexample.Populatetheoutercolumns
first.
Column 1

Column 2

Column 3

Column 4

Row 1

7.2K

15K

10K

15K

Row 2

7.2K

15K

10K

15K

Row 3

7.2K

15K

10K

15K

Installing 3.5" Drives


Install3.5drivecarriershorizontallyintothe12driveenclosure.Ifnecessary,remove
driveblanksfromtheenclosurestomakeroomforthedrives.
1 Releasethedrivecarrierhandlebydepressingthelatchinthehandle.

Figure 45. Release Drive Carrier Handle


2 InserttheDriveCarrierModuleintotheenclosure.

Figure 46. Installing a Drive Carrier Module


3 Makesurethatthedrivecarrierisorientedsothatthedrivefacesupandthehandle
opensfromtheleft.
4 Gentlyslidethedrivecarrierallthewayintotheenclosure.

50

Storage Center SC8000 Controller Deployment Guide

Install Drives in EN-SASx6x12/24 Enclosures

5 Rotatethehandleuntilitfullyengagesandclicksintoplace.
6 Makesurethatalldrivecarriersarefullyengagedintheenclosurebyfirmlypushing
eachoneintotheslot.

Figure 47. Engaging a Drive Carrier Module in an Enclosure


7 Activatetheantitamperlocksbyinsertingthekeyintothecutoutinthehandle.
8 Rotatethekeyclockwiseuntiltheindicatorisvisibleintheaperturebesidethekey.
9 Removethekey.

Figure 48. Activating the Anti-tamper Lock


10 Whentheenclosureisturnedonandthedrivesspinup,makesurethatthedriveLEDs
areon(green),indicatingnormalconditions.

See Also
ENSASx6x12/24StandardSASDrivesonpage 29

Dell Compellent

51

Chapter 2 Install the Hardware

Installing 2.5" Drives


Install2.5drivecarriersverticallyintothe24driveenclosure.
1 Makesurethatthecarrierisorientedsothatthedriveisontheleftsideandthehandle
opensfromthetop.
2 Releasethecarrierhandlebypressingthelatchinthehandledownwards.
3 Insertthecarrierintotheenclosureintheverticalposition.

Figure 49. 2.5" Drive Carrier Module in Open Position


4 Gentlyslidethecarrierallthewayintotheenclosureuntilitisstoppedbytheleveron
thebottomofthecarrier.

Figure 50. Inserting a 2.5" Drive Carrier Module (1)


5 Rotatethehandlefirmlyuntilthehandlefullyengages.Youwillhearaclickasthelatch
engagesandholdsthehandleclosed.

See Also
ENSASx6x12/24StandardSASDrivesonpage 29
ENSASx6x12/24DriveNumberingonpage 30

52

Storage Center SC8000 Controller Deployment Guide

Install Enterprise Plus Drives in SC200/220 Enclosures

Install Enterprise Plus Drives in SC200/220 Enclosures


SC200/220enclosuresareshippedwithdisksinstalledand/oremptydriveblanksin
unusedslots.ThefollowinginstructionsshowtheinstallationoftheDellEnterprisePlus
driveforreferenceonly.
Note: DellEnterprisePlusdrivesandEnterpriseSolidStateDrives(ESSDs)can
onlybeinstalledinSC200/220enclosures.

Figure 51. Installing a Drive


1 Inserttheharddrivecarrierintotheharddrivebay.
2 Slidethedriveintothebayuntilthecarriercontactsthebackplane.
3 Closetheharddrivecarrierhandletolocktheharddriveinplace.
4 Continuetopushfirmlyuntilyouhearaclickandthehandlefullyengages.
5 Whentheenclosureisturnedonandthedrivesspinup,makesurethatthedriveLEDs
areon(green),indicatingnormalconditions.

See Also
SC200/220EnterprisePlusDrivesonpage 24
SC200/220DriveNumberingonpage 25

Dell Compellent

53

Chapter 2 Install the Hardware

54

Storage Center SC8000 Controller Deployment Guide

Connect the Back End


EnclosuresareconnectedtocontrollersusingSAS,apointtopointswitchedtopologyon
fourlanes.EachlanecanperformconcurrentIOtransactionsat6Gb/sec.DellCompellent
recommendsconnectingtheSASdriveenclosurestothecontroller(s)usingthemost
redundantoptionsthatareavailable.

Contents
SASEnclosureCablingGuidelines ............................................. 55
ConnectIPCforDualControllerStorageCenters ................................ 56
ConnectSC200/SC220Enclosures .............................................. 60
ConnectSC280Enclosures .................................................... 75
ConnectENSASx6x12/24Enclosures .......................................... 84
LabeltheBackEndCables .................................................... 93

SAS Enclosure Cabling Guidelines


MultipleSASenclosuresareconnectedtoacontrollerbycablingtheenclosuresinseries.A
seriesofinterconnectedenclosuresisreferredtoasachain.Eachchaincancontainupto
1686GbpsSASdrives.
ASASchainbeginsataninitiatorportinacontrollerIOcardandconnectstothefirst
enclosure.Subsequentenclosuresareconnectedinseries.ForsinglecontrollerStorage
Centers,thechainendsatthelastenclosure.FordualcontrollerStorageCenters,thechain
endsinatargetportintheoppositecontroller.

SAS Redundancy
RedundantSAScablingensuresthatintheeventanIOCardorportfails,IOcontinuesto
flowthroughtheremainingfunctioningpath(s).FordualcontrollerStorageCenters,
redundantcablingalsoprovidesprotectionforcontrollerfailures.Toachieveredundancy,
eachSASchainismadeupoftwopathsthatarereferredtoastheAsideandBside.

Dell Compellent

55

Chapter 3 Connect the Back End

SC8000 SAS Port Types


TherearetwotypesofcontrollerSASports:initiatoronlyandinitiator/target.SASchains
beginwithaninitiatorport.Asshowninthefollowingfigure,ports12(circledinblue)on
SASIOcardsareinitiatoronly,andports34(circledinred)areinitiator/target.
1

Figure 52. Controller SAS Port Types


1 Initiator Only (Ports 12)
2 Initiator/Target (Ports 34)

Connect IPC for Dual-Controller Storage Centers


IfyouareconfiguringadualcontrollerStorageCenter,connectthecontrollerswitha
Category(Cat)6Ethernetcable.IftheStorageCenteronlyusesasingleSASchain,you
mustalsointerconnectthecontrollerswithadditionalSASconnectionstomakesurethat
sufficientIPCbandwidthisavailable.

56

Storage Center SC8000 Controller Deployment Guide

Connect IPC for Dual-Controller Storage Centers

Connect the Controllers with Ethernet


InadualcontrollerStorageCenter,theETH1portsofthecontrollersmustbedirectly
connectedtoeachother.
1 ConnecttheETH1(port1)ononecontrollertothesameportonthesecondcontroller.
UseaCat6cableforthisconnection.
Note: StorageCentercurrentlyrunsthe10Gbportsat1Gbspeed.UseaCat.6
cabletoensurethatahardwarechangeisunnecessarywhen10Gbratesare
implemented.

1 3 0 2
IPC MGMT

1 3 0 2
IPC MGMT

Figure 53. Ethernet IPC Connection


2 LabelbothendsoftheEthernetIPCcable.
a LocatetheIPClabelsthatshippedwiththecontroller(s).

Figure 54. IPC Cable Label


b Neartheconnector,alignthelabelperpendiculartothecableandaffixitstarting
withthetopedgeofthelabel.

Dell Compellent

57

Chapter 3 Connect the Back End

Figure 55. Align Cable Label


c

Wrapthelabelaroundthecableuntilitfullyencirclesthecable.Thebottomofeach
premadelabelisclearsothatitdoesnotobscurethetext.

Figure 56. Wrap Cable Label


d Applyamatchinglabeltotheotherendofthecable.

58

Storage Center SC8000 Controller Deployment Guide

Connect IPC for Dual-Controller Storage Centers

Connect the Controllers with SAS


IftheStorageCenterhasonlyasingleSASchain,interconnectthecontrollerswith
additionalSASconnectionstoprovideredundancyandtomakesurethatsufficientIPC
bandwidthisavailable.Iftwoormoreenclosurechainsexist,IPCDirectConnectis
optional.
IftheStorageCenterrequiresSASIPC,addcablingbetweentheinitiatorandtargetports
onthecontrollers.
1 ControllerA:IOCardport2(initiator)ControllerB:IOCardport4(target).
2 ControllerB:IOCardport2(initiator)ControllerA:IOCardport 4(target).
3 LabelbothendsofeachSASIPCcable.
a LocatetheIPClabelsthatshippedwiththecontroller(s).

Figure 57. IPC Cable Label


b Neartheconnector,alignthelabelperpendiculartothecableandaffixitstarting
withthetopedgeofthelabel.

Figure 58. Align Cable Label

Dell Compellent

59

Chapter 3 Connect the Back End

Wrapthelabelaroundthecableuntilitfullyencirclesthecable.Thebottomofeach
premadelabelisclearsothatitdoesnotobscurethetext.

Figure 59. Wrap Cable Label


d Applyamatchinglabeltotheotherendofthecable.

Connect SC200/SC220 Enclosures


ThissectionshowscommoncablingbetweentheSC8000controllerandSC200/220SAS
enclosures.LocatethescenariothatmostcloselymatchestheStorageCenteryouare
configuringandfollowtheinstructions,modifyingthemasnecessary.
AnSC200/SC220cablingchaincancontainupto168SASdrives,usingeithertypeof
enclosure.Themaximumnumberofanyonetypeofenclosureis:

SC200:14enclosures

SC220:7enclosures

EachSASIOcardsupportsuptotwochainsofenclosures.Allenclosuresattachedtothe
sameSASIOcardmustberunningatthesamespeed(all6Gbor3Gb).
SC200/220SASenclosurechainsarecabledasfollows.

60

SideA:EnclosuresareconnectedfromBporttoAport,usingthetopEMMs.

SideB:EnclosuresareconnectedfromAporttoBport,usingthebottomEMMs.

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Path

High-Level Steps

Chain1:SideA 1 Connectthefirstcontrollerport1tothefirstenclosure,topEMM,portA.
2 ConnecttheremainingenclosuresinseriesfromBporttoAportusingthetop
EMMs.
3 IftheStorageCenterhasdualcontrollers,connectthelastenclosure,topEMM,
portBtothesecondcontroller,port3.
Chain1:SideB 1 Connectthefirstcontrollerport3tothelastenclosure,bottomEMM,portB.
2 ConnecttheremainingenclosuresinseriesfromAporttoBportusingthe
bottomEMM.
3 IftheStorageCenterhasdualcontrollers,connectthetopenclosure,bottom
EMM,portAtothesecondcontroller,port1.

Note: ThecablingillustrationsinthischapterrefertoenclosuresasEnclosure1,
Enclosure2,andsoon.Thenumbersshownintheillustrationsmaynotmatchthe
IndexnumberassignedbytheSystemManager.StorageCenterassignsanIndex
onlyafterthesystemispoweredupandatleastonedriveisassignedtoaDisk
Folder.

Single Controller, Single Enclosure, Low Profile SAS


ThisillustrationshowsanSC8000controllercabledtoa6GbSASenclosureusingalow
profileSASIOcardinalowprofilecardslot.
1 2 3 4

Figure 60. Single SC8000 Controller, Single SAS Enclosure, Low Profile SAS IO Card
Path

Connections

Chain1:ASide Controller:slot3,port1Enclosure:topEMM,port A.
Chain1:BSide

Dell Compellent

Controller:slot3,port3Enclosure:bottomEMM,port B.

61

Chapter 3 Connect the Back End

Single Controller, Single Enclosure


ThisillustrationshowsanSC8000controllercabledtoasingleSASenclosureusingafull
heightIOcard.

Figure 61. Single SC8000 Controller, Single SAS Enclosure


Path

Connections

Chain1:ASide Controller:slot6,port1Enclosure:topEMM,port A.
Chain1:BSide

62

Controller:slot6,port3Enclosure:bottomEMM,port B.

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Single Controller, Four Enclosures, Single Chain, Low Profile SAS


ThisillustrationshowsasingleSC8000controllercabledtofourSASenclosuresusingthe
lowprofileSASIOcardinalowprofileslot.
Controller

Enclosure 1

A
A

B
B

Enclosure 2

Enclosure 3

Enclosure 4

Figure 62. Single SC8000 Controller, Single SAS Chain, Low-profile SAS Card
Path

Connections

Chain1:ASide 1 Controller:slot3,port1Enclosure1:topEMM,portA.
2 Enclosure1:topEMM,portBEnclosure2:topEMM,port A.
3 Enclosure2:topEMM,portBEnclosure3:topEMM,port A.
4 Enclosure3:topEMM,portBEnclosure4:topEMM,port A.
Chain1:BSide

1 Enclosure1:bottomEMM,portBEnclosure2:bottomEMM,portA.
2 Enclosure2:bottomEMM,portBEnclosure3:bottomEMM,portA.
3 Enclosure3:bottomEMM,portBEnclosure4:bottomEMM,portA.
4 Enclosure4:bottomEMM,portBController:slot3,port3.

Dell Compellent

63

Chapter 3 Connect the Back End

Single Controller, Four Enclosures, Single Chain


ThisillustrationshowsasingleSC8000controllercabledtofourSASenclosures.
Controller

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 63. Single SC8000 Controller, Single SAS Chain


Path

Connections

Chain1:ASide 1 Controller:slot6,port1Enclosure1:topEMM,portA.
2 Enclosure1:topEMM,portBEnclosure2:topEMM,port A.
3 Enclosure2:topEMM,portBEnclosure3:topEMM,port A.
4 Enclosure3:topEMM,portBEnclosure4:topEMM,port A.
Chain1:BSide

1 Enclosure1:bottomEMM,portBEnclosure2:bottomEMM,portA.
2 Enclosure2:bottomEMM,portBEnclosure3:bottomEMM,portA.
3 Enclosure3:bottomEMM,portBEnclosure4:bottomEMM,portA.
4 Enclosure4:bottomEMM,portBController:slot6,port3.

64

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Single Controller, Four Enclosures, Two IO Cards, Two Chains, Low


Profile SAS
ThisillustrationshowsasingleSC8000controllercabledtofourSASenclosuresintwo
chainsusinglowprofileSASIOcardsinlowprofilecardslots.Whencablingasecond
chainofenclosures,useasecondIOcardtoimproveredundancy.
Controller
1 2 3 4

Enclosure 1
A

Enclosure 2

Enclosure 3
A

Enclosure 4
A

Figure 64. Single SC8000 Controller, Four SAS Enclosures, Two IO Cards, Two Chains, Low-profile
SAS
Path

Connections

Chain1:ASide 1 Controller:slot2,port1Enclosure1:topEMM,portA.
2 Enclosure1:topEMM,portBEnclosure2:topEMM,portA.
Chain1:BSide

1 Enclosure1:bottomEMM,portBEnclosure2:bottomEMM,portA.
2 Enclosure2:bottomEMM,portBController:slot3,port 3.

Chain2:ASide 1 Controller:slot2port3Enclosure3:topEMM,portA.
2 Enclosure3:topEMM,portBEnclosure4:topEMM,portA.
Chain2:BSide

1 Enclosure3:bottomEMM,portBEnclosure4:bottomEMM,portA.
2 Enclosure4:bottomEMM,portBControllerslot3port 1.

Dell Compellent

65

Chapter 3 Connect the Back End

Single Controller, Four Enclosures, Two IO Cards, Two Chains


ThisillustrationshowsasingleSC8000controllercabledtofourSASenclosuresintwo
chains.Whencablingasecondchainofenclosures,useasecondIOcardtoimprove
redundancy.
Controller

4 3 2 1

3 2 1

Enclosure 1
A

Enclosure 2

Enclosure 3

Enclosure 4
A

Figure 65. Single SC8000 Controller, Four SAS Enclosures, Two IO Cards, Two Chains
Path

Connections

Chain1:ASide 1 Controller:slot6,port1Enclosure1:topEMM,portA.
2 Enclosure1:topEMM,portBEnclosure2:topEMM,portA.
Chain1:BSide

1 Enclosure1:bottomEMM,portBEnclosure2:bottomEMM,portA.
2 Enclosure2:bottomEMM,portBController:slot5,port 3.

Chain2:ASide 1 Controller:slot6,port3Enclosure3:topEMM,portA.
2 Enclosure3:topEMM,portBEnclosure4:topEMM,portA.
Chain2:BSide

1 Enclosure3:bottomEMM,portBEnclosure4:bottomEMM,portA.
2 Enclosure4:bottomEMM,portBControllerslot5,port 1.

66

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Dual Controllers, One Enclosure, Single Chain, Low Profile SAS


ThisillustrationshowstwoSC8000controllerscabledtotwo6Gbenclosuresusingalow
profileSASIOcardinalowprofilecardslotandcreatingasinglechain.
Note: Inasinglechainconfiguration,useSASports2(initiator)and4(target)to
createaredundantIPCconnection.WhenyouconfiguretheseportsusingtheIO
portwizard,settheportPurposetoUnknown.

Controller A

1 2 3 4

Controller B

Enclosure
A

Figure 66. Dual SC8000 Controllers, One Enclosure, One Chain, Low Profile SAS
Path

Connections

IPC

1 ControllerA:slot3,port2ControllerB:slot3,port4.
2 ControllerB:slot3,port2ControllerA:slot3,port 4.

Chain1:ASide 1 ControllerA:slot3,port1Enclosure:topEMM,portA.
2 Enclosure:topEMM,portBController B:slot3,port3.
Chain1:BSide

1 ControllerB:slot3,port1Enclosure:bottomEMM,portA.
2 Enclosure:bottomEMM,portBControllerA:slot3,port3.

Dell Compellent

67

Chapter 3 Connect the Back End

Dual Controllers, One Enclosure, Single Chain


ThisillustrationshowstwoSC8000controllerscabledtooneSASenclosureinasingle
chain.
Note: Inasinglechainconfiguration,useSASports2(initiator)and4(target)to
createaredundantIPCconnection.WhenyouconfiguretheseportsusingtheIO
portwizard,settheportPurposetoUnknown.

Controller A

Controller B

3 2

3 2

Enclosure
A

Figure 67. Dual SC8000 Controllers, One Enclosure, One Chain


Path

Connections

IPC

1 ControllerA:slot6,port2ControllerB:slot6,port4.
2 ControllerB:slot6,port2ControllerA:slot6,port 4.

Chain1:ASide 1 ControllerA:slot6,port1Enclosure:topEMM,portA.
2 Enclosure:topEMM,portBController B:slot6,port3.
Chain1:BSide

1 ControllerB:slot6,port1Enclosure:bottomEMM,portA.
2 Enclosure:bottomEMM,portBControllerA:slot6,port3.

68

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Dual Controllers, Two Enclosures, Single Chain, Low Profile SAS


ThisillustrationshowstwoSC8000controllerscabledtotwo6Gbenclosuresusingalow
profileSASIOcardinalowprofilecardslotandcreatingasinglechain.
Note: Inasinglechainconfiguration,useSASports2(initiator)and4(target)to
createaredundantIPCconnection.WhenyouconfiguretheseportsusingtheIO
portwizard,settheportPurposetoUnknown.
Controller A

1 2 34

Controller B

Enclosure 1
A

Enclosure 2

Figure 68. Dual SC8000 Controllers, Two Enclosures, One Chain, Low Profile SAS
Path

Connections

IPC

1 ControllerA:slot3,port2ControllerB:slot3,port4.
2 ControllerB:slot3,port2ControllerA:slot3,port 4.

Chain1:ASide 1 ControllerA:slot3,port1Enclosure1:topEMM,portA.
2 Enclosure1:topEMM,portBEnclosure2:topEMM,portA.
3 Enclosure2:topEMM,portB Controller B:slot3,port3.
Chain1:BSide

1 ControllerB:slot3,port1Enclosure1:bottomEMM,portA.
2 Enclosure1:bottomEMM,portBEnclosure 2:bottomEMM,portA.
3 Enclosure2:bottomEMM,portBControllerA:slot3,port3.

Dell Compellent

69

Chapter 3 Connect the Back End

Dual Controllers, Two Enclosures, Single Chain


ThisillustrationshowstwoSC8000controllerscabledtotwoSASenclosuresforminga
singlechain.Inasinglechainconfiguration,useSASports2(initiator)and4(target)to
createaredundantIPCconnection.WhenyouconfiguretheseportsusingtheIOport
wizard,settheportPurposetoUnknown.
Controller A

Controller B

Enclosure 1
A

Enclosure 2

Figure 69. Dual SC8000 Controllers, Two Enclosures, One Chain


Path

Connections

IPC

1 ControllerA:slot6,port2ControllerB:slot6,port4.
2 ControllerB:slot6,port2ControllerA:slot6,port 4.

Chain1:ASide 1 ControllerA:slot6,port1Enclosure1:topEMM,portA.
2 Enclosure1:topEMM,portBEnclosure2:topEMM,portA.
3 Enclosure2:topEMM,portB Controller B:slot6,port3.
Chain1:BSide

1 ControllerB:slot6,port1Enclosure1:bottomEMM,portA.
2 Enclosure1:bottomEMM,portBEnclosure 2:bottomEMM,portA.
3 Enclosure2:bottomEMM,portBControllerA:slot6,port3.

70

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Dual Controllers, Four Enclosures, Two Chains, Low Profile SAS


ThisillustrationshowstwoSC8000controllerscabledtotwo6Gbenclosures.Inthiscase,
theSC8000controllerscontainlowprofile,highdensitySAScardsinlowprofileslots2and
3.Eachenclosureisonaseparatechain.Whentwochainsareused,IPCisnotrequired.
Controller A

Controller B

Enclosure 1
A

Enclosure 2
A

Enclosure 3

Enclosure 4

Figure 70. Dual SC8000 Controllers, Two Enclosures, Two Chains, Low-profile SAS Card

Dell Compellent

71

Chapter 3 Connect the Back End

Path

Connections

Chain1:ASide 1 Controller A:slot2port1Enclosure1:topEMM,portA.


2 Enclosure1:topEMM,portBEnclosure2:topEMM,portA.
3 Enclosure2:topEMM,portBControllerB:slot2,port3.
Chain1:BSide

1 Controller B:slot3port1Enclosure1:bottomEMM,portA.
2 Enclosure1:bottomEMM,portBEnclosure2:bottomEMM,portA.
3 Enclosure2:bottomEMM,portBControllerA:slot3,port3.

Chain2:ASide 1 Controller A:slot2,port 3Enclosure3:topEMM,portA.


2 Enclosure3:topEMM,portBEnclosure4:topEMM,portA.
3 Enclosure4:topEMM,portBControllerB:slot2,port1.
Chain2:BSide

1 Controller B:slot3,port3Enclosure3:bottomEMM,portA.
2 Enclosure3:bottomEMM,portBEnclosure4:bottomEMM,portA.
3 Enclosure4:bottomEMM,portBControllerA:slot3,port1.

72

Storage Center SC8000 Controller Deployment Guide

Connect SC200/SC220 Enclosures

Dual Controllers, Four Enclosures, Two Chains


ThisillustrationshowstwoSC8000controllerscabledtotwoSASenclosures.Each
enclosureisonaseparatechain.Whentwochainsareused,IPCisoptional.
Controller A

Controller B

4 3 2 1

4 3 2 1

4 3 2 1

4 3 2 1

Enclosure 1
A

Enclosure 2

Enclosure 3

Enclosure 4

Figure 71. Dual SC8000 Controllers, Four Enclosures, Two Chains


Path

Connections

Chain1:ASide 1 Controller A:slot6,port1Enclosure1:topEMM,portA.


2 Enclosure1:topEMM,portBEnclosure2:topEMM,portA.
3 Enclosure2:topEMM,portBControllerB:slot6,port3.
Chain1:BSide

1 Controller B:slot5,port1Enclosure1:bottomEMM,portA.
2 Enclosure1:bottomEMM,portBEnclosure2:bottomEMM,portA.
3 Enclosure2:bottomEMM,portBControllerA:slot5,port3.

Chain2:ASide 1 Controller A:slot6,port 3Enclosure3:topEMM,portA.


2 Enclosure3:topEMM,portBEnclosure4:topEMM,portA.
3 Enclosure4:topEMM,portBControllerB:slot6,port1.

Dell Compellent

73

Chapter 3 Connect the Back End

Path

Connections

Chain2:BSide

1 Controller B:slot5,port3Enclosure3:bottomEMM,portA.
2 Enclosure3:bottomEMM,portBEnclosure4:bottomEMM,portA.
3 Enclosure4:bottomEMM,portBControllerA:slot5,port1.

Dual Controllers, Eight Enclosures, Two Chains


ThisillustrationshowstwoSC8000controllerscabledtoeight6Gbenclosuresusingtwo
chains.ToaddredundancywithmultipleIOcards,addasecondSASIOcard.Createthe
AsideofeachchainontheIO cardinslot6andcreatetheBsideofeachchainontheIO
cardinslot5.IfanIOcard,cable,enclosure,orcontrollerfails,atleastonesideofaloop
continuesoperating.IPCisoptionalinthisconfiguration.
Controller A 4 3 2 1

Controller B

Enclosure 1

4 3 2 1

4 32 1

4 3 2 1

Enclosure 5
A

Enclosure 2

Enclosure 6
A

Enclosure 3

Enclosure 7
A

Enclosure 4

Enclosure 8
A

Figure 72. Dual SC8000 Controllers, Eight Enclosures, Two Chains


Path

Connections

IPC

(Optional)CreateIPCconnectionsbetweenbothcontrollersonports2and4of
eachIOcard.

Chain1:ASide 1 ControllerA:slot6,port1Enclosure1:topEMM,portA.
2 StartingwithEnclosure1,daisychaintheAsideofChain1bycabling:top
EMM,portBnextenclosuredown:topEMM,portA.
3 FinishwithEnclosure 4:topEMM,portBControllerB:slot6,port3.

74

Storage Center SC8000 Controller Deployment Guide

Connect SC280 Enclosures

Path

Connections

Chain1:BSide

1 ControllerA:slot5,port3Enclosure4:bottomEMM,portB.
2 StartingwithEnclosure4,daisychaintheBsideofChain1bycabling:bottom
EMM,portAnextenclosureup:bottomEMM,portB.
3 FinishwithEnclosure1:bottomEMM,portAControllerB:slot5,port1.

Chain2:ASide 1 ControllerA:slot6,port3Enclosure5:topEMM,portA.
2 StartingwithEnclosure5,daisychaintheAsideofChain2bycabling:top
EMM,portBnextenclosuredown:topEMM,portA.
3 FinishwithEnclosure8:top,portBControllerB:slot 6,port1.
Chain2:BSide

1 ControllerA:slot5,port1Enclosure8:bottomEMM,portB.
2 StartingwithEnclosure8,daisychaintheBsideofChain2bycabling:bottom
EMM,portAnextenclosureup:bottomEMM,portB.
3 FinishwithEnclosure5:bottom,portAControllerB:slot 5,port3.

Connect SC280 Enclosures


ThissectionshowscommoncablingbetweentheSC8000controllerandSC280SAS
enclosures.LocatethescenariothatmostcloselymatchestheStorageCenteryouare
configuringandfollowtheinstructions,modifyingthemasnecessary.
AcablingchainfortheSC280cancontainuptotwoenclosuresof84SASdriveseach(168
drivestotal).Eachchainmustcontainthesametypeofenclosures,suchasallSC280.Do
notmixenclosuretypesinachain.
EachSASIOcardsupportsuptotwochainsofenclosures.Allenclosuresattachedtothe
sameSASIOcardmustberunningat6Gb.
SC280enclosurechainsarecabledasfollows.

SideA:EnclosuresareconnectedfromBporttoAport,usingtheleftEMMs.

SideB:EnclosuresareconnectedfromAporttoBport,usingtherightEMMs.

Path

High-Level Steps

Chain1:SideA 1 Connectcontrollerport1tothefirstenclosure,leftEMM,portC.
2 ConnecttheremainingenclosuresinseriesfromBporttoAportusingtheleft
EMMs.
3 IftheStorageCenterhasdualcontrollers,connectthelastenclosure,left
EMM,portCtothesecondcontroller,port3.
Chain1:SideB 1 Connectcontrollerport3tothelastenclosure,rightEMM,portC.
2 ConnecttheremainingenclosuresinseriesfromBporttoAportusingtheright
EMM.
3 IftheStorageCenterhasdualcontrollers,connectthetopenclosure,right
EMM,portCtothesecondcontroller,port1.

Note: ThecablingillustrationsinthischapterrefertoenclosuresasEnclosure1,
Enclosure2,andsoon.Thenumbersshownintheillustrationsmaynotmatchthe
IndexnumberassignedbytheSystemManager.StorageCenterassignsanIndex
onlyafterthesystemispoweredupandatleastonedriveisassignedtoaDisk
Folder.

Dell Compellent

75

Chapter 3 Connect the Back End

See Also
SASEnclosureCablingGuidelinesonpage 55

Single Controller, Single SC280 Enclosure


ThisillustrationshowsanSC8000controllercabledtoasingleSC280enclosure.
1234

Figure 73. Single SC8000 Controller, Single SC280 Enclosure


Path

Connections

Chain1:ASide Controller:slot3,port1Enclosure:leftEMM,port C.
Chain1:BSide

76

Controller:slot3,port3Enclosure:rightEMM,port C.

Storage Center SC8000 Controller Deployment Guide

Connect SC280 Enclosures

Single Controller, Two SC280 Enclosures


ThisillustrationshowsasingleSC8000controllercabledtotwoSC280enclosures.
Controller
4

1 234

Enclosure 1

Enclosure 2

Figure 74. Single SC8000 Controller, Two SC280 Enclosures, Single Chain
Path

Connections

Chain1:ASide 1 Controller:slot3,port1Enclosure1:leftEMM,port C.
2 Enclosure1:leftEMM,portBEnclosure2:leftEMM,port A.
Chain1:BSide

1 Controller:slot3,port3Enclosure2:rightEMM,portC.
2 Enclosure2:rightEMM,portBEnclosure1:rightEMM,portA.

Dell Compellent

77

Chapter 3 Connect the Back End

Dual Controller, Single SC280 Enclosure


ThisillustrationshowstwoSC8000controllerscabledtooneSC280enclosureinasingle
chain.
Note: Inasinglechainconfiguration,useSASports2(initiator)and4(target)to
createaredundantIPCconnection.WhenyouconfiguretheseportsusingtheIO
portwizard,settheportPurposetoUnknown.
Controller A
1 2 3 4

Controller B
1 23 4

Enclosure

Figure 75. Dual SC8000 Controllers, One SC280 Enclosure, One Chain
Path

Connections

IPC

1 ControllerA:slot3,port2ControllerB:slot3,port4.
2 ControllerB:slot3,port2ControllerA:slot3,port 4.

Chain1:ASide 1 ControllerA:slot3,port1Enclosure:leftEMM,portC.
2 Enclosure:leftEMM,portBController B:slot3,port3.
Chain1:BSide

1 ControllerB:slot3,port1Enclosure:rightEMM,portC.
2 Enclosure:rightEMM,portBControllerA:slot3,port3.

78

Storage Center SC8000 Controller Deployment Guide

Connect SC280 Enclosures

Dual Controller, Two SC280 Enclosures


ThisillustrationshowstwoSC8000controllerscabledtotwoSC280enclosuresinasingle
chain.
Note: Inasinglechainconfiguration,useSASports2(initiator)and4(target)to
createaredundantIPCconnection.WhenyouconfiguretheseportsusingtheIO
portwizard,settheportPurposetoUnknown.
Controller A
1 23 4

Controller B
1 23 4

Enclosure 1

Enclosure 2

Figure 76. Dual SC8000 Controllers, Two SC280 Enclosures, One Chain

Dell Compellent

79

Chapter 3 Connect the Back End

Path

Connections

IPC

1 ControllerA:slot3,port2ControllerB:slot3,port4.
2 ControllerB:slot3,port2ControllerA:slot3,port 4.

Chain1:ASide 1 ControllerA:slot3,port1Enclosure:1leftEMM,portC.
2 Enclosure1:leftEMM,portBEnclosure:2leftEMM,portA.
3 Enclosure2:leftEMM,portCControllerB:slot3,port3.
Chain1:BSide

1 ControllerB:slot3,port1Enclosure:1rightEMM,portC.
2 Enclosure1:rightEMM,portAEnclosure:2rightEMM,portB.
3 Enclosure2:rightEMM,portCControllerA:slot3,port3.

80

Storage Center SC8000 Controller Deployment Guide

Connect SC280 Enclosures

Dual Controllers, Two SC280 and Two SC200/SC220 Enclosures,


Two Chains
ThisillustrationshowstwoSC8000controllerscabledtotwoSC280Enclosuresandtwo
SC200/220enclosuresintwochains.
ToaddredundancywithmultipleIOcards,addasecondSASIOcard.CreatetheAsides
ofeachchainontheIOcardinslot2andcreatetheBsidesofeachchainontheIOcardin
slot3.IfanIOcard,cable,enclosure,orcontrollerfails,atleastonesideofachaincontinues
operating.IPCisoptionalinthisconfiguration.
Whenconnectingdifferenttypesofenclosures,eachtypemustresideonitsownchain.For
example,donotmixSC280EnclosuresandSC200Enclosuresinthesamechain.In
addition,allenclosuresmustbe6Gbenclosures.
Note: Themaximumstoragespaceis1petabyte,regardlessofthenumberortype
ofenclosures.

Dell Compellent

81

Chapter 3 Connect the Back End

1234

1234

3 2 1

3 2 1

Controller A

Controller B

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 77. Dual SC8000 Controllers, Mixed Enclosures, Two Chains

82

Storage Center SC8000 Controller Deployment Guide

Connect SC280 Enclosures

Path

Connections

IPC

(Optional)CreateIPCconnectionsbetweenbothcontrollersonports2and4of
eachSASIOcard.

SC280 Enclosures
Chain1:ASide 1 ControllerA:slot2,port1Enclosure1:leftEMM,portC.
2 Enclosure1leftEMM,portBEnclosure2:leftEMM,portA.
3 FinishwithEnclosure 2:leftEMM,portCControllerB:slot2,port3.
Chain1:BSide

1 ControllerB:slot3,port1Enclosure1:rightEMM,portC.
2 Enclosure1rightEMM,portAEnclosure2:rightEMM,portB.
3 FinishwithEnclosure 2:rightEMM,portCControllerA:slot3,port3.

SC200/220 Enclosures
Chain2:ASide 1 ControllerA:slot2,port3Enclosure3:topEMM,portA.
2 Enclosure3topEMM,portBEnclosure4:topEMM,portA.
3 FinishwithEnclosure 4:topEMM,portBControllerB:slot2,port1.
Chain2:BSide

1 ControllerA:slot3,port1Enclosure4:bottomEMM,portB.
2 Enclosure4bottomEMM,portAEnclosure3:bottomEMM,portB.
3 FinishwithEnclosure 3:bottomEMM,portAControllerB:slot3,port3.

Dell Compellent

83

Chapter 3 Connect the Back End

Connect EN-SASx6x12/24 Enclosures


ThissectionshowscommoncablingbetweentheSC8000controllerandENSASx6x12/24
SASenclosures.LocatethescenariothatmostcloselymatchestheStorageCenteryouare
configuringandfollowtheinstructions,modifyingthemasnecessary.
ASAScablingchaincancontainupto14enclosuresandupto1686GbpsSASdrives.Each
chainmustcontainthesametypeofenclosures,suchasallENSASx6x12/24.Donotmix
enclosuretypesinachain.
ENSASx6x12/24SASenclosurechainsarecabledasfollows.

SideA:EnclosuresareconnectedfromBporttoAport,usingthetopSBBs.

SideB:EnclosuresareconnectedfromAporttoBport,usingthebottomSBBs.

Path

High-Level Steps

Chain1:SideA 1 Connectcontrollerport1tothefirstenclosure,topSBB,portC.
2 ConnecttheremainingenclosuresinseriesfromBporttoAportusingthetop
SBBs.
3 IftheStorageCenterhasdualcontrollers,connectthelastenclosure,topSBB,
portCtothesecondcontroller,port3.
Chain1:SideB 1 Connectcontrollerport3tothelastenclosure,bottomSBB,portC.
2 ConnecttheremainingenclosuresinseriesfromBporttoAportusingthe
bottomSBB.
3 IftheStorageCenterhasdualcontrollers,connectthetopenclosure,bottom
SBB,portCtothesecondcontroller,port1.

Note: ThecablingillustrationsinthischapterrefertoenclosuresasEnclosure1,
Enclosure2,andsoon.Thenumbersshownintheillustrationsmaynotmatchthe
IndexnumberassignedbytheSystemManager.StorageCenterwhichassignsan
IndexonlyafterthesystemispoweredupandatleastonedriveisassignedtoaDisk
Folder.

See Also
SASEnclosureCablingGuidelinesonpage 55

84

Storage Center SC8000 Controller Deployment Guide

Connect EN-SASx6x12/24 Enclosures

Single Controller, Single Enclosure


ThisillustrationshowsanSC8000controllercabledtooneSASenclosure.

Figure 78. Single SC8000 Controller, Single SAS Enclosure


Path

Connections

Chain1:ASide Controller:slot6,port1Enclosure:topSBB,port C.
Chain1:BSide

Dell Compellent

Controller:slot6,port3Enclosure:bottomSBB,port C.

85

Chapter 3 Connect the Back End

Single Controller, Four Enclosures, Single Chain


ThisillustrationshowsasingleSC8000controllercabledtofourSASenclosures.
Controller

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 79. Single SC8000 Controller, Single 6 Gb Chain


Path

Connections

Chain1:ASide 1 Controller:slot6,port1Enclosure1:topSBB,portC.
2 Enclosure1:topSBB,portBEnclosure2:topSBB,port A.
3 Enclosure2:topSBB,portBEnclosure3:topSBB,port A.
4 Enclosure3:topSBB,portBEnclosure4:topSBB,port A.
Chain1:BSide

1 Enclosure1:bottomSBB,portAEnclosure2:bottomSBB,portB.
2 Enclosure2:bottomSBB,portAEnclosure3:bottomSBB,portB.
3 Enclosure3:bottomSBB,portAEnclosure4:bottomSBB,portB.
4 Enclosure4:bottomSBB,portCController:slot6,port3.

86

Storage Center SC8000 Controller Deployment Guide

Connect EN-SASx6x12/24 Enclosures

Single Controller, Four Enclosures, Two IO Cards, Two Chains


ThisillustrationshowsasingleSC8000controllercabledtofourSASenclosuresintwo
chains.Whenyouaddasecondchain,youshouldalsohaveasecondIOcardinthe
controller.
Controller

4 3

2 1

4 3

2 1

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 80. Single SC8000 Controller, Four 6 Gb Enclosures, Two IO Cards, Two Chains
Path

Connections

Chain1:ASide 1 Controller:slot6,port1Enclosure1:topSBB,portC.
2 Enclosure1:topSBB,portBEnclosure2:topSBB,portA.
Chain1:BSide

1 Enclosure1:bottomSBB,portAEnclosure2:bottomSBB,portB.
2 Enclosure2:bottomSBB,portCController:slot5,port 3.

Chain2:ASide 1 Controller:slot6,port3Enclosure3:topSBB,port C.
2 Enclosure3:topSBB,portBEnclosure4:topSBB,portA.
Chain2:BSide

1 Enclosure3:bottomSBB,portAEnclosure4:bottomSBB,portB.
2 Enclosure4:bottomSBB,portCControllerslot5,port 1.

Dell Compellent

87

Chapter 3 Connect the Back End

Dual Controllers, Two Enclosures, Single Chain


ThisillustrationshowstwoSC8000controllerscabledtotwoSASenclosuresforminga
singlechain.Inasinglechainconfiguration,useSASports2and4tocreatearedundant
IPCconnection.WhenyouconfiguretheseportsusingtheIOportwizard,settheport
PurposetoUnknown.
Controller A

Controller B

Enclosure 1

Enclosure 2

Figure 81. Dual SC8000 Controllers, Two Enclosures, One Chain


Path

Connections

IPC

1 ControllerA:slot6,port2ControllerB:slot6,port4.
2 ControllerB:slot6,port2ControllerA:slot6,port 4.

Chain1:ASide 1 ControllerA:slot6,port1Enclosure1:topSBB,portC.
2 Enclosure1:topSBB,portBEnclosure2:topSBB,portA.
3 Enclosure2:topSBB,portCController B:slot6,port3.
Chain1:BSide

1 ControllerB:slot6,port1Enclosure1:bottomSBB,portC.
2 Enclosure1:bottomSBB,portAEnclosure 2:bottomSBB,portB.
3 Enclosure2:bottomSBB,portCControllerA:slot6,port3.

88

Storage Center SC8000 Controller Deployment Guide

Connect EN-SASx6x12/24 Enclosures

Dual Controllers, Four Enclosures, Two Chains


ThisillustrationshowstwoSC8000controllerscabledtotwoSASenclosures.Each
enclosureisonaseparatechain.Whentwochainsareused,IPCisoptional.
Controller A 4 3 2 1

4 3 2 1

Controller B

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 82. Dual SC8000 Controllers, Two Enclosures, Two Chains


Path

Connections

Chain1:ASide 1 Controller A:slot6,port1Enclosure1:topSBB,portC.


2 Enclosure1:topSBB,portBEnclosure2:topSBB,port A.
3 Enclosure2:topSBB,portCControllerB:slot6,port3.
Chain1:BSide

1 ControllerA:slot5,port 3Enclosure2:bottomSBB,portC.
2 Enclosure2:bottomSBB,portBEnclosure1:bottomSBB,portA.
3 Enclosure1:bottomSBB,portCControllerB:slot5,port 1.

Chain2:ASide 1 Controller A:slot6port 3Enclosure3:topSBB,portC.


2 Enclosure3:topSBB,portBEnclosure4:topSBB,port A.
3 Enclosure4:topSBB,portCControllerB:slot6,port1.
Chain2:BSide

1 Controller A:slot5port1Enclosure4:bottomSBB,portC.
2 Enclosure4:bottomSBB,portBEnclosure3:bottomSBB,portA.
3 Enclosure3:bottomSBB,portCControllerB:slot5,port 3.

Dell Compellent

89

Chapter 3 Connect the Back End

Dual Controllers, Four Enclosures, Single Chain


ThisillustrationshowstwoSC8000controllerswithoneSASIOCardcabledtofourSAS
enclosures.Inasinglechainconfiguration,useSASports2and4tocreatearedundantIPC
connection.WhenyouconfiguretheseportsusingtheIOportwizard,settheportPurpose
toUnknown.
Controller A

4 3 2 1

Controller B

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 83. Dual SC8000 Controllers, Four Enclosures, One IO Card, One Chain
Path

Connections

IPC

1 ControllerA:slot6,port2Controller B:slot6,port4.
2 ControllerB:slot6,port2Controller A: slot6,port 4.

Chain1:ASide 1 ControllerA:slot6,port1Enclosure1:topSBB,portC.
2 Enclosure1,topSBB,portBEnclosure2,topSBB,portA.
3 Continuetodaisychainenclosures:topSBB,portBnextenclosuredown:
topSBB,port A.
4 Enclosure4:topSBB,portCController B: slot6,port3.
Chain1:BSide

1 ControllerB:slot6,port1Enclosure 1: bottomSBB,portC.
2 Enclosure1:bottomSBB,portAEnclosure 2:bottomSBB,portB.
3 Continuetodaisychainenclosures:bottomSBB,portAnextenclosure
down:bottomSBB,portB.
4 Enclosure4:bottomSBB,portCController A:slot6,port 3.

90

Storage Center SC8000 Controller Deployment Guide

Connect EN-SASx6x12/24 Enclosures

Dual Controllers, Eight Enclosures, Two Chains


ThisillustrationshowstwoSC8000controllerscabledtoeightSASenclosuresintwo
chains.ToaddredundancywithmultipleIOcards,addasecondSASIOcard.Createthe
AsidesofeachchainontheIOcardinslot6andcreatetheBsidesofeachchainontheIO
cardinslot5.IfanIOcard,cable,enclosure,orcontrollerfails,atleastonesideofachain
continuesoperating.IPCisoptionalinthisconfiguration.

Controller A

Controller

4 3 2 1

4 3 2 1

Enclosure 1

Enclosure 5

Enclosure 2

Enclosure 6

Enclosure 3

Enclosure 7

Enclosure 4

Enclosure 8

Figure 84. Dual SC8000 Controllers, Eight Enclosures, Two Chains


Path

Connections

IPC

(Optional)CreateIPCconnectionsbetweenbothcontrollersonports2and4of
eachIOcard.

Chain1:ASide 1 ControllerA:slot6,port1Enclosure1:topSBB,portC.
2 StartingwithEnclosure1,daisychaintheAsideofChain1bycabling:top
SBB,portBnextenclosuredown:topSBB,portA.
3 FinishwithEnclosure 4:topSBB,portC?ControllerB:slot6,port3.
Chain1:BSide

1 ControllerA:slot5,port3Enclosure4:bottomSBB,portC.
2 StartingwithEnclosure4,daisychaintheBsideofChain1bycabling:bottom
SBB,portBnextenclosureup:bottomSBB,portA.
3 FinishwithEnclosure1:bottomSBB,portCControllerB:slot5,port1.

Dell Compellent

91

Chapter 3 Connect the Back End

Path

Connections

Chain2:ASide 1 ControllerA:slot6,port3Enclosure5:topSBB,portC.
2 StartingwithEnclosure5,daisychaintheAsideofChain2bycabling:top
SBB,portBnextenclosuredown:topSBB,portA.
3 FinishwithEnclosure8:topSBB,portC?ControllerB:slot 6,port1.
Chain2:BSide

1 ControllerA:slot5,port1Enclosure8:bottomSBB,portC.
2 StartingwithEnclosure8,daisychaintheBsideofChain2bycabling:bottom
SBB,portBnextenclosureup:bottomSBB,portA.
3 FinishwithEnclosure5:bottomSBB,portCControllerB:slot 5,port3.

92

Storage Center SC8000 Controller Deployment Guide

Label the Back-End Cables

Label the Back-End Cables


Labelthebackendcablesthatconnectcontrollerstoenclosurestoindicatethechain
numberandside(AorB).PremadelabelsareprovidedforSC200/220enclosures.Labels
arenotprovidedforENSASx6x12/24enclosures,solabelsmustbecreatedmanuallyfor
cablesthatconnecttothoseenclosures.
Note: Cablesthatconnectoneenclosuretoanotherdonotneedtobelabeled.

Prerequisites
IftheStorageCenterhasENSASx6x12/24enclosures,youmusthavealabelmaker,orfour
blanklabelsandawritingutensil.

Steps
1 Locateorcreatelabelsforthebackendcables.

ENSASx6x12/24enclosures:Createlabelsthatlabelthepurpose(Backend),chain
number,andside(AorB).
Example:Backend1A

SC200/220enclosures:Locatethebackendcablelabelsthatshippedwiththe
enclosures.Thepremadelabelsincludethepurpose(Backend),chainnumber,and
side(AorB).

Figure 85. SC200/220 Back-End Cable Label

Dell Compellent

93

Chapter 3 Connect the Back End

2 ApplycablelabelstobothendsofeachSAScablethatconnectsacontrollertoan
enclosure.
a Neartheconnector,alignthelabelperpendiculartothecableandaffixitstarting
withthetopedgeofthelabel.

Figure 86. Align Cable Label


b Wrapthelabelaroundthecableuntilitfullyencirclesthecable.Thebottomofeach
premadelabelisclearsothatitdoesnotobscurethetext.

Figure 87. Wrap Cable Label


c

94

Applyamatchinglabeltotheotherendofthecable.

Storage Center SC8000 Controller Deployment Guide

Connect the Front End


Frontendcablingreferstoconnectionsbetweenthecontrollerandtheserver.Frontend
connectionscanbemadeusingiSCSI,FibreChannel,orFibreChanneloverEthernet
(FCoE).DellCompellentrecommendsconnectingserverstothecontroller(s)usingthe
mostredundantoptionsavailable.

Contents
TypesofRedundancyforFrontEndConnections ................................ 95
MultipathIO ................................................................ 96
FrontEndConnectivityModes ................................................ 96
FibreChannelZoning ....................................................... 102
ConnecttheFrontEndforaSingleControllerStorageCenter .................... 103
ConnecttheFrontEndforaDualControllerStorageCenter ..................... 105
LabeltheFrontEndCables .................................................. 116

Types of Redundancy for Front-End Connections


Frontendredundancyisachievedbyeliminatingsinglepointsoffailurethatcouldcause
aservertoloseconnectivitytotheStorageCenter.
DependingonhowtheStorageCenterisconfigured,thefollowingtypesofredundancy
areavailable.

Pathredundancy:WhenmultiplepathsareavailablefromaservertoaStorageCenter,
aserverconfiguredformultipathIO(MPIO)canusemultiplepathsforIO.Ifapath
fails,theservercontinuestousetheremainingactivepath(s).

Controllerredundancy:IfonecontrollerfailsinadualcontrollerStorageCenter,the
frontendportsfailovertothefunctioningcontroller.Bothfrontendconnectivity
modes(legacymodeandvirtualportmode)providecontrollerredundancy.

Portredundancy:Invirtualportmode,ifaportgoesdownbecauseitisdisconnected
orthereisahardwarefailure,theportcanfailovertoanotherfunctioningportinthe
samefaultdomain.Portredundancyisavailableforsinglecontrolleranddual
controllerStorageCentersoperatinginvirtualportmode.

See Also
MultipathIOonpage 96
LegacyModeonpage 99
VirtualPortModeonpage 97

Dell Compellent

95

Chapter 4 Connect the Front End

Multipath IO
MultipathIO(MPIO)allowsaservertousemultiplepathsforIOiftheyareavailable.
MPIOsoftwareoffersredundancyatthepathlevel.MPIOloadsasadriverontheserver,
andtypicallyoperatesinaroundrobinmannerbysendingpacketsfirstdownonepath
andthentheother.Ifapathfails,MPIOsoftwarecontinuestosendpacketsdownthe
functioningpath.MPIOisoperatingsystemspecific.

MPIO Behavior for Dual-Controller Storage Centers


WhenMPIOisconfigured,aservercansendIOtobothcontrollers.However,asingle
volumeisownedbyonecontrolleratatime.Evenifthereareactivepathsfromaserverto
bothcontrollers,IOforasinglevolumeisalwaysprocessedbyonecontroller.
Thislimitationonlyappliestoindividualvolumes.Ifaserverhastwoormorevolumes
ownedbydifferentcontrollers,theservercansendIOtobothcontrollers.

MPIO Configuration Instructions for Servers


TouseMPIO,configureMPIOontheserverpriortoconnectingtheStorageCenterfront
end.Dependingontheoperatingsystem,thismayrequireinstallingMPIOsoftwareor
mayonlyrequiresettingserveroptions.
ToconfigureMPIOonaserver,seetheDellCompellentdocumentthatcorrespondstothe
serveroperatingsystem.
Operating System

Document with MPIO Instructions

IBMAIX

DellCompellentAIXBestPractices

Linux

DellCompellentStorageCenterLinuxBestPractices
DellCompellentBestPractices:StorageCenterwithSUSELinux
EnterpriseServer11

VMwarevSphere5.x

DellCompellentStorageCenterBestPracticeswithvSphere5.x

WindowsServer2003

StorageCenterMultipathIO(MPIO)ManagerforMicrosoftServersUser
Guide

WindowsServer2008,2008
R2,and2012

DellCompellentStorageCenterMicrosoftMultipathIO(MPIO)Best
PracticesGuide

Front-End Connectivity Modes


StorageCenteruseseitherlegacymodeorvirtualportmodetotransportdatatoservers
thatuseSANstorage.Inlegacymode,frontendIOportsareconfiguredinpairsofprimary
andreservedports.Invirtualportmode,allportsareactive,andifoneportfailstheload
isdistributedbetweentheremainingportswithinthesamefaultdomain.
Note: InLegacymode,reserveportsandprimaryportsresideonseparate
controllers,providingcontrollerlevelfailoveronly.Legacymodedoesnotprovide
portlevelfailover.
ThefrontendconnectivitymodeisconfiguredindependentlyforFibreChannelandiSCSI.
Bothtransporttypescanbeconfiguredtousethesamemodeordifferentmodestomeet
theneedsofthenetworkinfrastructure.Forexample,aStorageCentercanbeconfigured
tousevirtualportmodeforFCandlegacymodeforiSCSI.

96

Storage Center SC8000 Controller Deployment Guide

Front-End Connectivity Modes

Note: DellCompellentstronglyrecommendsusingvirtualportmodeunlessthe
networkenvironmentdoesnotmeettherequirementsforvirtualportmode.

Virtual Port Mode


Virtualportmodeprovidesportandcontrollerredundancybyconnectingmultipleactive
portstoeachFibreChannelorEthernetswitch.
Invirtualportmode,eachphysicalporthasaWWN(WorldWideName),andisalso
assignedanadditionalvirtualWWN.ServerstargetonlythevirtualWWNs.During
normalconditions,allportsprocessIO.Ifaportorcontrollerfails,avirtualWWNcanbe
movedtoanotherphysicalWWNinthesamefaultdomain.Whenthefailureisresolved
andportsarerebalanced,thevirtualportreturnstothepreferredphysicalport.
Virtualportmodeprovidesthefollowingadvantagesoverlegacymode:

Increasedperformance:Becauseallportsareactive,additionalfrontendbandwidthis
availablewithoutsacrificingredundancy.

Improvedredundancy:Portscanfailoverindividuallyinsteadofbycontroller.

SimplifiediSCSIconfiguration:EachfaultdomainhasaniSCSIcontrolportthat
coordinatesdiscoveryoftheiSCSIportsinthedomain.WhenaservertargetstheiSCSI
portIPaddress,itautomaticallydiscoversallportsinthefaultdomain.

Fault Domains in Virtual Port Mode


FaultdomainsgroupfrontendportsthatareconnectedtothesameFibreChannelfabric
orEthernetnetwork.Portsthatbelongtothesamefaultdomaincanfailovertoeachother
becausetheyhavethesameconnectivity.
Thefollowingrequirementsapplytofaultdomainsinvirtualportmode:

AseparatefaultdomainmustbecreatedforeachfrontendFibreChannelfabricor
Ethernetnetwork.

Afaultdomainmustcontainasingletypeoftransportmedia(FCoriSCSI,butnot
both).

DellCompellentrecommendsconfiguringatleasttwoconnectionsfromeachcontroller
toeachFibreChannelorEthernetnetwork(faultdomain).

Requirements for Virtual Port Mode


ThefollowingrequirementsmustbemettoconfigureaStorageCenterinvirtualport
mode.

Dell Compellent

Requirement

Description

License

TheStorageCentermustbelicensedforvirtualportmode.

Switches

FrontendportsmustbeconnectedtoFibreChannelorEthernetswitches;
serverscannotbedirectlyconnectedtocontrollerfrontendports.

97

Chapter 4 Connect the Front End

Requirement

Description

Multipathing

Ifmultipleactivepathsareavailabletoaserver,theservermustbe
configuredforMPIOtousemorethanonepathsimultaneously.

iSCSInetworks

NATmustbedisabledforiSCSIreplicationtraffic.
CHAPauthenticationmustbedisabled.

FibreChannelfabrics

TheFCtopologymustbeswitchedfabric.Pointtopointandarbitrated
looptopologiesarenotsupported.
FCswitchesmustbezonedtomeetthevirtualportmodezoning
requirements.
FCswitchesmustsupportN_PortIDVirtualization(NPIV).
PersistentFCIDmustbedisabledonFCswitches.
Note: AIXserversarenotsupported.

See Also
FibreChannelZoningonpage 102

Example Virtual Port Mode Configuration


ThefollowingfigureshowsadualcontrollerStorageCenterinvirtualportmode
connectedtoaFibreChannelserverwithasinglefaultdomain.Allportsbelongtoasingle
faultdomainbecausetheyareconnectedtothesameFCswitch.
Server

FC Switch
Active Ports
Controller A

Controller B

Figure 88. Virtual Ports Example with FC


Note: Tousebothprimarypathssimultaneously,theservermustbeconfiguredto
useMPIO.
Thefollowingtablesummarizesthefailoverbehaviorsforthisconfiguration.
Scenario

Failover Behavior

Normaloperatingconditions AllportsareactiveandpassIO.

98

ControllerAfails

VirtualportsoncontrollerAfailoverbymovingtophysicalports
oncontrollerB.

ControllerBfails

VirtualportsoncontrollerBfailoverbymovingtophysicalportson
controllerA.

Asingleportfails

Thevirtualportassociatedwiththefailedphysicalportmovesto
anotherphysicalportinthefaultdomain.

Storage Center SC8000 Controller Deployment Guide

Front-End Connectivity Modes

Legacy Mode
LegacymodeprovidescontrollerredundancyforadualcontrollerStorageCenterby
connectingmultipleprimaryandreservedportstoeachFibreChannelorEthernetswitch.
Inlegacymode,eachprimaryportonacontrollerispairedwithacorrespondingreserved
portontheothercontroller.Duringnormalconditions,theprimaryportsprocessIOand
thereservedportsareinstandbymode.Ifacontrollerfails,theprimaryportsfailoverto
thecorrespondingreservedportsontheothercontroller.Thisapproachensuresthat
serversconnectedtotheswitchdonotloseconnectivityifoneofthecontrollersfails.For
optimalperformance,theprimaryportsshouldbeevenlydistributedacrossboth
controllers.Whenpossible,frontendconnectionsshouldbemadetoseparatecontrollerIO
cardstoimproveredundancy.

Fault Domains in Legacy Mode


EachpairofprimaryandreservedportsisgroupedintoafaultdomainintheStorage
Centersoftware.Thefaultdomaindetermineswhichportsareallowedtofailovertoeach
other.
Thefollowingrequirementsapplytofaultdomainsinlegacymodeonadualcontroller
StorageCenter:

Afaultdomainmustcontainaonetypeoftransportmedia(FCoriSCSI,butnotboth).

Afaultdomainmustcontainoneprimaryportandonereservedport.

Thereservedportmustbelocatedonadifferentcontrollerthantheprimaryport.
Note: ForasinglecontrollerStorageCenter,onlyonefaultdomainisrequiredfor
eachtransporttype(FCoriSCSI)becausetherearenoreservedports.

Requirements for Legacy Mode


ThefollowingrequirementsmustbemettoconfigureaStorageCenterinlegacymode.
Requirement

Description

Controllerfrontend
ports

Eachcontrollermusthaveenoughfrontendportstoconnecttwopathsto
eachFibreChannelorEthernetswitch.

Multipathing

Ifmultipleactivepathsareavailabletoaserver,theservermustbe
configuredforMPIOtousemorethanonepathsimultaneously.

FibreChannelzoning

FCswitchesmustbezonedtomeetthelegacymodezoningrequirements.

See Also
FibreChannelZoningonpage 102

Dell Compellent

99

Chapter 4 Connect the Front End

Example Legacy Mode Configuration


ThefollowingfigureshowsadualcontrollerStorageCenterinlegacymodeconnectedto
aFibreChannelserverwithtwofaultdomains.Faultdomain1(showninorange)is
comprisedofprimaryportP1oncontrollerAandreservedportR1oncontrollerB.Fault
domain2(showningreen)iscomprisedofprimaryportP2oncontrollerBandreserved
portR2oncontrollerA.
Server

FC Switch
Reserved Port R1

Primary Port P1

Primary Port P2

Reserved Port R2
Controller A

Controller B

Figure 89. Legacy Mode Example with FC


Note: Tousemultiplepathssimultaneously,theservermustbeconfiguredtouse
MPIO.
Thefollowingtablesummarizesthefailoverbehaviorsforthisconfiguration.
Scenario

Failover Behavior

Normaloperatingconditions PrimaryportsP1andP2(bothfaultdomains)passIO.
ReservedportsR1andR2remaininastandbymodeuntila
controllerfailure.

100

ControllerAfails

Infaultdomain1,primaryportP1failsovertoreservedportR1.

ControllerBfails

Infaultdomain2,primaryportP2failsovertoreservedportR2.

Asingleportfails

Theportdoesnotfailoverbecausetherewasnocontrollerfailure.If
asecondpathisavailable,MPIOsoftwareontheserverprovides
faulttolerancebysendingIOtothefunctioningportintheother
faultdomain.

Storage Center SC8000 Controller Deployment Guide

Front-End Connectivity Modes

Failover Behavior for Legacy Mode and Virtual Port Mode


Legacymodeandvirtualportmodebehavedifferentlyduringfailureconditionsbecause
theyusedifferentmechanismstoprovidefaulttolerance.
Scenario

Virtual Port Mode

Normaloperatingconditions AllportsareactiveandpassIO.

Legacy Mode
PrimaryportspassIO.
Reservedportsremainina
standbymodeuntila
controllerfailure.

Acontrollerfailsinadual
controllerStorageCenter

Virtualportsonthefailed
Primaryportsonthefailed
controllermovetophysicalports controllerfailovertoreserved
portsonthefunctioning
onthefunctioningcontroller.
controller.

Asingleportfails(singleor Anindividualportfailsoverto Theportdoesnotfailover


dualcontrollerStorage
anotherportinthefaultdomain. becausetherewasnocontroller
Center)
failure.Ifasecondpathis
available,MPIOsoftwareonthe
serverprovidesfaulttolerance.

Note: InLegacymode,reserveportsandprimaryportsresideonseparate
controllers,providingcontrollerlevelfailoveronly.Legacymodedoesnotprovide
portlevelfailover.

Dell Compellent

101

Chapter 4 Connect the Front End

Fibre Channel Zoning


WhenusingFibreChannelforfrontendconnectivity,zonesmustbeestablishedtoensure
thatstorageisvisibletotheservers.Planthefrontendconnectivityusingzoningconcepts
discussedinthissectionbeforestartingtocablethecontroller.
ZoningcanbeappliedtoeithertheportsonswitchesortotheWorldWideNames(WWNs)
oftheenddevices.Zonesshouldbecreatedusingasingleinitiator(usingphysicalWWNs)
andmultipletargets(usingvirtualWWNs).
Inadualcontrollerconfiguration,thevirtualWWNsfromeachcontrollermustbe
includedinthezonewitheachhostsWWN.
Note: Forvirtualportmode,WWNzoningisrecommended.

WWN Zoning Guidelines


WhenWWNzoningisconfigured,adevicemayresideonanyportorchangephysical
portsandstillbevisiblebecausetheswitchisseekingaWWN.
Connectivity Type

Guidelines

Legacymode

IncludeallStorageCenterfrontendWWNsorportsinasingle
zone.
Createserverzonesthatcontainasingleinitiatorandmultiple
targets,andwhichincludetheserverHBAWWN.

Virtualportmode

IncludeallStorageCentervirtualWWNsinasinglezone.
IncludeallStorageCenterphysicalWWNsinasinglezone.
Createserverzonesthatcontainasingleinitiatorandmultiple
targets(StorageCentervirtualWWNs),andwhichincludethe
serverHBAWWN.

FibreChannelreplication

IncludeallStorageCenterphysicalWWNsfromSystemAandB
inasinglezone.
IncludeallStorageCenterphysicalWWNsofSystemAandthe
virtualWWNsofSystemBontheparticularFabric.
IncludeallStorageCenterphysicalWWNsofSystemBandthe
virtualWWNsofSystemAontheparticularFabric.
Note: Someportsmaynotbeusedordedicatedforreplication,
howeverportsthatareusedmustbeinthesezones.

Port Zoning Guidelines


Whenportzoningisconfigured,onlyspecificswitchportsarevisible.Ifastoragedeviceis
movedtoadifferentportthatisnotpartofthezone,itisnolongervisibletotheotherports
inthezone.
Connectivity Type

Guidelines

Legacymodeorvirtualport IncludeallStorageCenterfrontendports.
mode
CreateserverzoneswhichcontainallStorageCenterfrontend
portsandasingleserverport.
FibreChannelreplication

102

IncludeallStorageCenterfrontendportsfromSystemAand
SystemBinasinglezone.

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Single-Controller Storage Center

Connect the Front End for a Single-Controller Storage Center


UseFibreChannelandiSCSItoconnectserverstotheStorageCenter.Foreachtransport
type,chooseafrontendconnectivitymode(legacymodeorvirtualportmode),andthen
connecttheserversinawaythatmeetstherequirementsofthechosenconnectivitymode.
Applycablelabelstobothendsofeachcable.
Note: Thecablinginstructionsanddiagramsinthissectionarevalidforaparticular
IOcardconfiguration.IfthecontrollersyouareinstallingcontaindifferentIOcards,
adjustthecablingaccordingly.

Connect Servers to a Single Controller with No Redundancy


Connectserverswithoutusingredundancyifthecontrollerdoesnothaveenoughfront
endportstoallowredundantpathstoeachFCfabric,directlyconnectedFCserver,and
Ethernetswitch.

Prerequisites
ThecontrollermusthaveanavailablefrontendportforeachFCfabric,Ethernetswitch
(iSCSInetwork),andstandaloneFCserverthatyouwanttodirectlyconnect.
Note: iSCSIserversmustbeconnectedtoEthernetswitches.AniSCSIservercannot
bedirectlyconnectedtoafrontendiSCSIportonthecontroller.

Steps
1 ConnecttheFCfabrics.
a ConnectacontrollerFCporttoeachFCfabric.
b ConnectoneormoreFCserverstoeachFCfabric.
c

ConfigureFCzoningtomeetthezoningrequirements.

IfyouareplanningtoconfigureFCinlegacymode,configurezoningtomeetthe
legacymodezoningrequirements.

IfyouareplanningtoconfigureFCinvirtualportmode,configurezoningto
meetthevirtualportmodezoningrequirements.

2 ConnecttheiSCSInetworks.
a ConnectacontrolleriSCSIporttoeachiSCSInetwork.
b ConnectoneormoreiSCSIserverstoeachiSCSInetwork.
3 Duringthesoftwaresetupprocess,configurefaultdomainsbasedontheconnectivity
mode:

Dell Compellent

Legacymode:Createonefaultdomainforeachtransporttype(FCandiSCSI).

Virtualportmode:CreateonefaultdomainforeachfabricordirectlyconnectedFC
server.

103

Chapter 4 Connect the Front End

FC Server

SCSI Server

FC Switch

Ethernet Switch

Controller

Figure 90. Single Controller Without Front-End Redundancy

See Also
FibreChannelZoningonpage 102

Connect Servers to a Single Controller with Redundancy


Connectserverstoasinglecontrollerusingredundancyifyouwanttoprotectagainstport
failureonthecontroller,switch,orserver.Inlegacymode,faulttoleranceisprovidedby
MPIOontheconnectedservers.Invirtualportmode,faulttolerancecanbeprovidedby
MPIOorcontrollerportfailoverwithineachfaultdomain.

Prerequisites
ThecontrollermusthavetwoavailablefrontendportsforeachFCfabric,Ethernetswitch
(iSCSInetwork),andstandaloneFCserverthatyouwanttodirectlyconnect.
Note: iSCSIserversmustbeconnectedtoEthernetswitches.AniSCSIservercannot
bedirectlyconnectedtoafrontendiSCSIportonthecontroller.

Steps
1 ConnecttheFCfabrics.
a ConnecttwocontrollerFCportstoeachFCfabric.
b ConnectoneormoreFCserverstoeachFCfabric,makingtwoconnectionsfrom
eachservertothefabric.
c

ConfigureFCzoningtomeetthezoningrequirements.

IfyouareplanningtoconfigureFCinlegacymode,configurezoningtomeetthe
legacymodezoningrequirements.

IfyouareplanningtoconfigureFCinvirtualportmode,configurezoningto
meetthevirtualportmodezoningrequirements.

2 ConnecttheiSCSInetworks.
a ConnecttwocontrolleriSCSIportstoeachiSCSInetwork.
b ConnectoneormoreiSCSIserverstoeachiSCSInetwork,makingtwoconnections
fromeachservertothenetwork.
3 Duringthesoftwaresetupprocess,configurefaultdomainsbasedontheconnectivity
mode:

104

Legacymode:Createonefaultdomainforeachtransporttype(FCandiSCSI).

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Dual-Controller Storage Center

Virtualportmode:CreateonefaultdomainforeachfabricordirectlyconnectedFC
server.

FC Server

SCSI Server

FC Switch

Ethernet Switch

Controller

Figure 91. Single Controller With Front-End Redundancy

See Also
FibreChannelZoningonpage 102

Connect the Front End for a Dual-Controller Storage Center


UseFibreChannelandiSCSItoconnectserverstotheStorageCenter.Foreachtransport
type,chooseafrontendconnectivitymode(legacymodeorvirtualportmode),andthen
connecttheserversinawaythatmeetstherequirementsofthechosenconnectivitymode.
Applycablelabelstobothendsofeachcable.
Note: Thecablinginstructionsanddiagramsinthissectionarevalidforaparticular
IOcardconfiguration.IfthecontrollersyouareinstallingcontaindifferentIOcards,
adjustthecablingaccordingly.

Connect Fibre Channel Servers


ChoosetheFibreChannelconnectivityoptionthatbestsuitsthefrontendredundancy
requirementsandnetworkinfrastructure.

LegacyModewithSingleFabricFibreChannelonpage 105

LegacyModewithDualFabricFibreChannelonpage 107

VirtualPortModewithSingleFabricFibreChannelonpage 108

VirtualPortModewithDualFabricFibreChannelonpage 110

Legacy Mode with Single-Fabric Fibre Channel


ConnectlegacymodeFibreChanneltoasinglefabricifonlyoneFCswitchisavailableand
youwanttoprotectagainstcontrollerfailure.
Inthisconfiguration,twofaultdomainsarespreadacrossbothcontrollers.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1andP2R2).Thereservedpaths
provideredundancyforsinglecontrollerfailure.Thisconfigurationisvulnerabletoswitch
failure.

Dell Compellent

105

Chapter 4 Connect the Front End

Note: Topreventaportorcablefailurefromblockingaccesstovolumesmappedto
acontroller,connecttwoadditionalfaultdomainssothateachcontrollerhastwo
primarypathstotheFCfabric.

Prerequisites
EachcontrollermusthavetwoavailableFCfrontendports.

Steps
1 ConnecteachFCservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.

PrimaryportP1:ControllerA,slot1,port1Fabric1

ReservedportR1:ControllerB,slot1,port1Fabric1

3 Connectfaultdomain2(showninblue)tofabric1.

PrimaryportP2:ControllerB,slot2,port1Fabric1

ReservedportR2:ControllerA,slot2,port1Fabric1

4 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
Server 2

Server 1

Fabric 1

R1 R2
P2

P1
1

Controller A

Controller B

Figure 92. Dual-controller with Single-Fabric FC in Legacy Mode

See Also
FibreChannelZoningonpage 102

106

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Dual-Controller Storage Center

Legacy Mode with Dual-Fabric Fibre Channel


UsetwofabricswithlegacymodetopreventaFCswitchfailureorcontrollerfailurefrom
causinganoutage.
Inthisconfiguration,fourfaultdomainsarespreadacrossbothcontrollers.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1,P2R2,P3R3,andP4R4).To
provideredundancy,theprimaryportandthecorrespondingreserveportinafault
domainmustconnecttothesamefabric.WhenMPIOisconfiguredontheFCservers,the
primarypathsprovideredundancyforasingleportorcablefailure.Thereservedpaths
provideredundancyforsinglecontrollerfailure.

Prerequisites
EachcontrollermusthavetwoavailableFCfrontendportsforeachFCfabric.

Steps
1 ConnecteachFCservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.

PrimaryportP1:ControllerA,slot1,port1Fabric1

ReservedportR1:ControllerB,slot1,port1Fabric1

3 Connectfaultdomain2(showninblue)tofabric1.

PrimaryportP2:ControllerB,slot2,port1Fabric1

ReservedportR2:ControllerA,slot2,port1Fabric1

4 Connectfaultdomain3(showningreen)tofabric2.

PrimaryportP3:ControllerA,slot1,port2Fabric2

ReservedportR3:ControllerB,slot1,port2Fabric2

5 Connectfaultdomain4(showninpurple)tofabric2.

PrimaryportP4:ControllerB,slot2,port2Fabric2

ReservedportR4:ControllerA,slot2,port2Fabric2

6 ConfigureFCzoningtomeetthelegacymodezoningrequirements.

Dell Compellent

107

Chapter 4 Connect the Front End

Server 1

Server 2

Fabric 1

Fabric 2

R1 R2
P2

R4 P3 P4 R3
P1
1

Controller A

Controller B

Figure 93. Dual-controller with Dual-Fabric FC in Legacy Mode

See Also
FibreChannelZoningonpage 102

Virtual Port Mode with Single-Fabric Fibre Channel


ConnectvirtualportmodeFibreChanneltoasinglefabricifonlyoneFCisavailableand
youwanttoprotectagainstportorcontrollerfailure.
Inthisconfiguration,thereisonefaultdomainbecausethereisasingleFCfabric.Each
controllerisconnectedtothefabricbyatleasttwoFCconnectionstoprovideport
redundancy.Ifasingleportfails,itsvirtualportfailsovertoanotherport.Ifacontroller
fails,thevirtualportsonthefailedcontrollermovetoportsontheothercontroller.This
configurationisvulnerabletoswitchfailure.

Prerequisites

EachcontrollermusthavetwoavailableFCfrontendports.

Therequirementsforvirtualportmodemustbemet.

Steps
1 ConnecteachservertotheFCfabric.
2 Connectfaultdomain1(showninorange)tofabric1.

108

ControllerA,slot1,port1Fabric1

ControllerA,slot2,port1Fabric1

ControllerB,slot1,port1Fabric1

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Dual-Controller Storage Center

ControllerB,slot2,port1Fabric1

3 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
Server 1

Server 2

Fabric 1

1 2

1 2

Controller A

Controller B

Figure 94. Dual-controller with Single-Fabric FC in Virtual Port Mode

See Also
RequirementsforVirtualPortModeonpage 97
FibreChannelZoningonpage 102

Dell Compellent

109

Chapter 4 Connect the Front End

Virtual Port Mode with Dual-Fabric Fibre Channel


UsetwofabricswithvirtualportmodetopreventaFCswitchfailureorcontrollerfailure
fromcausinganoutage.
Inthisconfiguration,thereisonefaultdomainforeachFCfabric.Eachcontrolleris
connectedtobothfabricsbytwoFCconnections.Ifasingleportfails,itsvirtualportfails
overtoanotherportinthesamefaultdomain.Ifacontrollerfails,thevirtualportsonthe
failedcontrollermovetoportsontheothercontrollerinthesamefaultdomain.

Prerequisites

EachcontrollermusthavetwoavailableFCfrontendportsforeachFCfabric.

Therequirementsforvirtualportmodemustbemet.

Steps
1 ConnecteachservertobothFCfabrics.
2 Connectfaultdomain1(showninorange)tofabric1.

ControllerA,slot1,port1Fabric1

ControllerA,slot2,port1Fabric1

ControllerB,slot1,port1Fabric1

ControllerB,slot2,port1Fabric1

3 Connectfaultdomain2(showninblue)tofabric2.

ControllerA,slot1,port2Fabric2

ControllerA,slot2,port2Fabric2

ControllerB,slot1,port2Fabric2

ControllerB,slot2,port2Fabric2

4 ConfigureFCzoningtomeetthelegacymodezoningrequirements.
Server 1

Server 2

Fabric 1

Fabric 2

1 2

1 2

Controller A

Controller B

Figure 95. Dual-controller with Dual-Fabric FC in Virtual Port Mode

110

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Dual-Controller Storage Center

See Also
RequirementsforVirtualPortModeonpage 97
FibreChannelZoningonpage 102

Connect iSCSI Servers


ChoosetheiSCSIconnectivityoptionthatbestsuitsthefrontendredundancy
requirementsandnetworkinfrastructure.

LegacyModewithSingleNetworkiSCSIonpage 111

LegacyModewithDualNetworkiSCSIonpage 112

VirtualPortModewithSingleNetworkiSCSIonpage 114

VirtualPortModewithDualNetworkiSCSIonpage 115

Legacy Mode with Single-Network iSCSI


ConnectlegacymodeiSCSItoasinglenetworkifonlyoneEthernetswitchisavailableand
youwanttoprotectagainstcontrollerfailure.
Inthisconfiguration,twofaultdomainsarespreadacrossbothcontrollers.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1andP2R2).Thereservedpaths
provideredundancyforsinglecontrollerfailure.Thisconfigurationisvulnerabletoswitch
failure.
Note: Topreventaportorcablefailurefromblockingaccesstovolumesmappedto
acontroller,connecttwoadditionalfaultdomainssothateachcontrollerhastwo
primarypathstotheiSCSInetwork.

Prerequisites
EachcontrollermusthavetwoavailableiSCSIfrontendports.

Steps
1 ConnecteachiSCSIservertobothEthernetswitches.
2 Connectfaultdomain1(showninorange)toswitch1.

PrimaryportP1:ControllerA,slot3,port1Switch1

ReservedportR1:ControllerB,slot3,port1Switch1

3 Connectfaultdomain2(showninblue)toswitch1.

Dell Compellent

PrimaryportP2:ControllerB,slot4,port2Switch1

ReservedportR2:ControllerA,slot4,port2Switch1

111

Chapter 4 Connect the Front End

Server

Ethernet Switch 1
iSCSI Network 1

P1

R1

P2

R2

Controller A
1 2

2 1

4 3 2 1

2 1

Controller B
1 2

3 2 1

Figure 96. Dual-controller with Single-Network iSCSI in Legacy Mode

Legacy Mode with Dual-Network iSCSI


Usetwonetworkswithlegacymodetopreventaswitchfailureorcontrollerfailurefrom
causinganoutage.
Inthisconfiguration,fourfaultdomainsarespreadacrossbothcontrollers.Eachfault
domaincontainssetsofprimaryandreservepaths(P1R1,P2R2,P3R3,andP4R4).To
provideredundancy,theprimaryportandthecorrespondingreserveportinafault
domainmustconnecttothesamenetwork.WhenMPIOisconfiguredontheiSCSIservers,
theprimarypathsprovideredundancyforasingleportorcablefailure.Thereservedpaths
provideredundancyforsinglecontrollerfailure.

Prerequisites
EachcontrollermusthavetwoavailableiSCSIfrontendportsforeachEthernetswitch.

Steps
1 ConnecteachiSCSIservertobothEthernetswitches.
2 Connectfaultdomain1(showninorange)toswitch1.

112

PrimaryportP1:ControllerA,slot3,port1Switch1

ReservedportR1:ControllerB,slot3,port1Switch1

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Dual-Controller Storage Center

3 Connectfaultdomain2(showninblue)toswitch1.

PrimaryportP2:ControllerB,slot4,port2Switch1

ReservedportR2:ControllerA,slot4,port2Switch1

4 Connectfaultdomain3(showningreen)toswitch2.

PrimaryportP3:ControllerA,slot4,port1Switch2

ReservedportR3:ControllerB,slot4,port1Switch2

5 Connectfaultdomain4(showninpurple)toswitch2.

PrimaryportP4:ControllerB,slot3,port2Switch2

ReservedportR4:ControllerA,slot3,port2Switch2
Server

Ethernet Switch 1
iSCSI Network 1

Ethernet Switch 2
iSCSI Network 2

P1 R1 P2 R2

R4 P3 R3 P4

Controller A

2 1

4 3 2 1

Controller B

2 1

1 2

3 2 1

1 2

Figure 97. Dual-controller with Dual-Network iSCSI in Legacy Mode

Dell Compellent

113

Chapter 4 Connect the Front End

Virtual Port Mode with Single-Network iSCSI


ConnectvirtualportmodeiSCSItoasinglenetworkifonlyoneEthernetswitchisavailable
andyouwanttoprotectagainstportorcontrollerfailure.
Inthisconfiguration,thereisonefaultdomainbecausethereisasinglenetwork.Each
controllerisconnectedtothefabricbyatleasttwoiSCSIconnectionstoprovideport
redundancy.Ifasingleportfails,itsvirtualportfailsovertoanotherport.Ifacontroller
fails,thevirtualportsonthefailedcontrollermovetoportsontheothercontroller.This
configurationisvulnerabletoswitchfailure.

Prerequisites

EachcontrollermusthavetwoavailableiSCSIfrontendports.

Therequirementsforvirtualportmodemustbemet.

Steps
1 ConnecteachservertotheiSCSInetwork.
2 Connectfaultdomain1(showninorange)toiSCSInetwork1.

ControllerA,slot3,port1Switch1

ControllerB,slot3,port1Switch1

ControllerB,slot4,port2Switch1

ControllerA,slot4,port2Switch1
Server

Ethernet Switch 1
iSCSI Network 1

Controller A

2 1

4 3 2 1

Controller B

2 1

1 2

3 2 1

1 2

Figure 98. Dual-Controller with Single-Network iSCSI in Virtual Port Mode

114

Storage Center SC8000 Controller Deployment Guide

Connect the Front End for a Dual-Controller Storage Center

Virtual Port Mode with Dual-Network iSCSI


UsetwonetworkswithvirtualportmodetopreventanEthernetswitchfailureor
controllerfailurefromcausinganoutage.
Inthisconfiguration,thereisonefaultdomainforeachiSCSInetwork.Eachcontrolleris
connectedtobothEthernetnetworksbytwoiSCSIconnections.Ifasingleportfails,its
virtualportfailsovertoanotherportinthesamefaultdomain.Ifacontrollerfails,the
virtualportsonthefailedcontrollermovetoportsontheothercontrollerinthesamefault
domain.

Prerequisites

EachcontrollermusthavetwoavailableiSCSIfrontendportsforeachiSCSInetwork.

Therequirementsforvirtualportmodemustbemet.

Steps
1 ConnecteachiSCSIservertobothEthernetswitches.
2 Connectfaultdomain1(showninorange)toiSCSInetwork1.

ControllerA,slot3,port1Switch1

ControllerB,slot3,port1Switch1

ControllerB,slot4,port2Switch1

ControllerA,slot4,port2Switch1

3 Connectfaultdomain2(showninpurple)toiSCSInetwork2.

Dell Compellent

ControllerA,slot4,port1Switch2

ControllerB,slot4,port1Switch2

ControllerB,slot3,port2Switch2

ControllerA,slot3,port2Switch2

115

Chapter 4 Connect the Front End

Server

Ethernet Switch 1
iSCSI Network 1

Ethernet Switch 2
iSCSI Network 2

Controller A

2 1

4 3 2 1

Controller B

2 1

1 2

3 2 1

1 2

Figure 99. Dual-Controller with Dual-Network iSCSI in Virtual Port Mode

Label the Front-End Cables


Labelthefrontendcablestoindicatewhichcontrollertheyareconnectedto,aswellasthe
controllerslotandport.PremadelabelsareshippedwithSC8000controllers.
1 Locatethepremadefrontendcablesthatshippedwiththecontroller(s).

Figure 100. Front-End Cable Label

116

Storage Center SC8000 Controller Deployment Guide

Label the Front-End Cables

2 ApplycablelabelstobothendsofeachiSCSIcablethatconnectsacontrollertoafront
endswitch.
a Preparetwolabelsbywritingthecontrollernumber,slot,andportthatthecableis
connectedto.
b Neartheconnector,alignthelabelperpendiculartothecableandaffixitstarting
withthetopedgeofthelabel.

Figure 101. Align Cable Label


c

Wrapthelabelaroundthecableuntilitfullyencirclesthecable.Thebottomofeach
premadelabelisclearsothatitdoesnotobscurethetext.

Figure 102. Wrap Cable Label


d Applyamatchinglabeltotheotherendofthecable.

Dell Compellent

117

Chapter 4 Connect the Front End

3 ApplycablelabelstobothendsofeachFCcablethatconnectsacontrollerafrontend
fabricorserver.
a Preparetwolabelsbywritingthecontrollernumber,slot,andportthatthecableis
connectedto.
b Neartheconnector,alignthedottedlineonthelabelwiththeedgeofthecableand
affixitstartingwiththetopedgeofthelabel.

Figure 103. Align Cable Label


c

Wrapthelabelaroundthecableuntilitfullyencirclesthecable.Thebottomofeach
premadelabelisclearsothatitdoesnotobscurethetext.

Figure 104. Wrap Cable Label


d Applyamatchinglabeltotheotherendofthecable.

118

Storage Center SC8000 Controller Deployment Guide

Set up the Storage Center Software


ConnecttheStorageCentermanagementinterfacesandconfiguretheStorageCenter
software.

Contents
Prerequisites ............................................................... 119
ConnecttheEthernetManagementandiDRACInterfaces ....................... 121
TurnontheHardware ...................................................... 124
ConfiguretheController(s) .................................................. 124
VerifySoftwareSupportforEnclosures ........................................ 127
StarttheStorageCenterStartupWizard ....................................... 128
CompletetheStartupWizard ................................................ 129
LabelSC200andSC220Enclosures ........................................... 163

Prerequisites
BeforetheStorageCentersoftwarecanbeconfigured,thehardwaremustbeconnected,
andyoumusthavetherequiredmaterialsanddocuments.

Hardware Configuration
Allhardwaremustbeinstalledandcabledbeforebeginningthesoftwaresetupprocess.If
serverconnectivityisthroughFibreChannel(FC),theFCswitchesmustbeconfiguredand
zonedbeforeconfigureingthecontroller(s).

Dell Compellent

119

Chapter 5 Set up the Storage Center Software

Required Materials
RemoteconnectionstotheStorageCenterarerequiredduringdifferentstagesof
configuration.
Makesurethatyouhavetheitemslistedinthefollowingtable.
Required Item

Purpose

RS232serialcableandPCor Usedtoruncommandsandviewconsolemessagesduring
laptop
controllerconfiguration.
Computerconnectedtothe UsedtoconnecttotheStorageCenterSystemManager(througha
samenetworkastheStorage webbrowser)tocompletetheStorageCenterconfiguration.
Center
StorageCenterlicensefile

Usedtoactivatepurchasedfeatures.
Licensefilesusethenamingconventionsnxxx_35_date.lic,where:
snxxxistheserialnumberoftheStorageCenter.
35indicatesthatthesystemrunssoftwarehigherthanversion3.5.
dateshowsthelicensegenerationdateinYYMMDDformat.
.licisthefileextension.

Required Documents
AStorageArchitectorBusinessPartnerdesignedthecomponentsofStorageCenterforthe
specificsite.Preinstallationdocumentationcontainsdetailedinformationfromthedesign
thatisusedduringthesetupprocess.
Preinstallationdocumentsinclude:

Listofhardwareneededtosupportstoragerequirements

HardwareSerialNumber(HSN)andSystemSerialNumber(SSN)usedtoconfigurethe
controller(s)

Optionalconnectivitydiagramstoillustratecablingbetweenthecontrollers,
enclosures,switches,andservers

Optionalnetworkinformation,suchasIPaddresses,subnetmasks,gateways

Refertothesedocumentsforinformationaboutsitespecificsettingsusedduringcontroller
configuration.

Required Software Versions


StorageCenterhardwarehasminimumsoftwareversionrequirements.

120

Hardware

Minimum Software Version

SC8000(controller)

6.1.2

SC200/220(enclosures)

6.2.1

SC280(enclosures)

6.4.1

Storage Center SC8000 Controller Deployment Guide

Connect the Ethernet Management and iDRAC Interfaces

Connect the Ethernet Management and iDRAC Interfaces


TheiDRACandEthernetmanagementportsmustbeconnectedtoamanagementnetwork.

TheETH0portsupportssystemloginandaccesstothemanagementsoftware.Itisalso
usedtosendemail,alerts,SNMPtraps,andsystemdatausingPhoneHome.

TheiDRACconnectionprovidesaccesstothecontrollerforsysteminformationand
diagnostics.

Connect Single-Controller Management Ports


ConnectthecontrollerEthernetmanagementandiDRACportstoamanagementnetwork.
1 Connectthe1GbETH0(port0)toanEthernetswitch.
2 ConnecttheiDRACporttotheEthernetswitchusinga1GbEthernetcable.
Switch (Corporate/Public Network)

Controller

3
IPC

0
2
MGMT

iDRAC
1 Gb ETH 0 Port

Figure 105. Single Controller Management Connections

Dell Compellent

121

Chapter 5 Set up the Storage Center Software

Connect Dual-Controller Management Ports


ConnectEthernetmanagementandiDRACportsforbothcontrollerstoamanagement
network.
1 Connectthe1GbETH0(port0)oneachcontrollertoanEthernetswitchorVLAN.
2 ConnecttheiDRACporttothesameEthernetswitchusinga1GbEthernetcable.
Switch (Corporate/Public Network)

1 Gb ETH 0 Port
Controller A

3
IPC

0
2
MGMT

3
IPC

0
2
MGMT

iDRAC

Controller B

iDRAC

1 Gb ETH 0 Port

Figure 106. Dual-Controller Management Connections

Label the Management Cables


LabeltheEthernetmanagementcablesandiDRACcableswiththepremadelabelsthat
shippedwiththecontroller(s).
1 LocatetheEthernetmanagementandiDRAClabelsthatshippedwiththecontroller(s).

Figure 107. Management Cable Label

122

Storage Center SC8000 Controller Deployment Guide

Connect the Ethernet Management and iDRAC Interfaces

2 LabelbothendsofeachEthernetcablewiththeappropriatemanagementoriDRAC
label.
a Neartheconnector,alignthelabelperpendiculartothecableandaffixitstarting
withthetopedgeofthelabel.

Figure 108. Align Cable Label


b Wrapthelabelaroundthecableuntilitfullyencirclesthecable.Thebottomofeach
premadelabelisclearsothatitdoesnotobscurethetext.

Figure 109. Wrap Cable Label


c

Dell Compellent

Applyamatchinglabeltotheotherendofthecable.

123

Chapter 5 Set up the Storage Center Software

Turn on the Hardware


Turnontheenclosuresfirst,andafterthedisksspinup,turnonthecontrollers.
1 Connecttheenclosuresandcontroller(s)toapowersource.
2 TurnoneachenclosureattachedtotheStorageCenter.
a Simultaneouslypressbothpowerswitchesontherearoftheenclosuretoturnonthe
enclosure.
b RepeatwitheachenclosureattachedtotheStorageCenter,waitingforthedisksto
spinupbetweenenclosures.
Note: Makesurethatalldisksareupandspinningatfullspeedbeforeturning
onanycontrollers.
3 Turnoneachcontrollerbypressingandholdingthepowerbuttononthefrontofthe
controller.Thefansturnonasanindicationthatthecontrollerisstartingtocomeup.

Configure the Controller(s)


Useaserialconnectiontothecontroller(s)tosettheinitialconfiguration.

Reset Hardware and System Serial Numbers


Configurethecontroller(s)withtheHSNandSSNprovidedinthepreinstallation
documents.
Note: IfconfiguringadualcontrollerStorageCenter,performthistaskforboth
controllers.UsethelowestserialnumberforController1.
1 Establishaserialconnectiontothecontroller.
a UseanRS232serialcabletoconnectaPCorlaptoptoaStorageCentercontrollers
RS232serialport.(ToconnectfromaUSBport,useaUSBtoRS232converter.)
b TurnonthePC.
c

Openaterminalemulatororacommandlineinterface.Configuretheconnectionas
showninthefollowingtable.
Setting

Value

Emulation

VT220

ColumnMode

132

LineWrapping

Off

Connection

SerialPort

ConnectionType Direct

124

BaudRate

115,200

Parity

None

DataBits

StopBits

FlowControl

Hardwareordefault

Storage Center SC8000 Controller Deployment Guide

Configure the Controller(s)

Note: Tofacilitatetroubleshooting,enableloggingforthesession.
d PresstheEnterkeyseveraltimestoinitiatetheconnection.Theterminalechoesback
toindicatethatconnectivityhasbeenestablished.Iftheprompt(>)isnotdisplayed,
seeTroubleshootingtheSerialConnectiononpage 205.
2 SettheHSNandSSNusingtheSSN(s)providedinthepreinstallationdocuments.
Caution: Thefollowingcommandsarefornewinstallationsonly.Runningthe
cs purge all commandonanexistingStorageCentercontrollerdeletesthe
existingconfigurationandcanmakedatainaccessible.

Controller1:SettheHSNandSSNtothelowerSSN.
shellaccess developer
platform init hsn set [lowerSSN]
platform init ssn set [lowerSSN]
cs purge all
-reset

Controller2:(Dualcontrolleronly)SettheHSNandSSNtothehigherSSN.
shellaccess developer
platform init hsn set [higherSSN]
platform init ssn set [higherSSN]
cs purge all
-reset

Thecontrollertakesseveralminutestoreboot.Thecontrollermayrebootmorethan
oncethisisnormal.
3 Whentherebootiscomplete,verifythatthetablethatisdisplayedendswith:
2 1 Finish

4 Verifythenewsettingsbyrunningthecontroller showcommand.
Note: Althoughenteredindecimal,thenewHSNandSSNvaluesarereturned
inhexadecimal.
5 Recordthefactorydefaulteth1address.FordualcontrollerStorageCenters,theeth1
addressfromController2isneededduringthesetupprocess.

Set Controller IP Addresses


StorageCentercontrollersusestaticIPaddresses.ConfigureanIPaddressforthe
managementinterface(eth0),specifyoneormoreDNSservers,andsetthedomainname
towhichtheStorageCenterbelongs.

eth0supportssystemloginandaccessforthesoftware.Itisusedtosendemails,alerts,
SNMPtraps,andPhoneHomedata.

eth1isusedfordedicatedInterProcessCommunication(IPC)betweencontrollersina
dualcontrollerStorageCenter.Becauseeth1isdirectlyconnectedtotheother
controller,nodefaultgatewayisrequired.
Donotchangetheeth1addressunlessbothcontrollerswerefactoryconfiguredwiththe
sameaddressorthecustomerrequeststhechange.Theeth1addresscannotresidein
thesamesubnetaseth0.

Dell Compellent

125

Chapter 5 Set up the Storage Center Software

Note: IfconfiguringadualcontrollerStorageCenter,performthistaskforboth
controllers.
1 Runthefollowingcommandtoconfigurethemanagementinterface(etho).
controller ipconfig eth0 [IP address] [netmask] [gateway]

Example:
controller ipconfig eth0 172.31.1.101 255.255.0.0 172.31.0.1

2 RunthefollowingcommandtospecifyoneormoreDNSservers.
controller dnsserver [DNS server 1 IP address] [DNS server 2 IP address]

Example:
controller dnsserver 172.31.0.50 172.31.0.60

3 RunthefollowingcommandtospecifythedomaintowhichtheStorageCenterbelongs.
controller domainname [domain name]

Example:
controller domainname corp.dom

4 Verifythechangestothenetworksettingsbyrunningthefollowingcommand:
controller show

Manage the iDRAC IP Address


TheSC8000controllerincludestheIntegratedDellRemoteAccessController(iDRAC7)
thatisfactoryconfiguredforDynamicHostConfigurationProtocol(DHCP).TheiDRAC
canbeleftwiththeoriginalconfigurationoritcanbeassignedastaticIPaddress.
Note: TousetheiDRACinanonDHCPenvironment,astaticIPaddressmustbe
set.

ToseeiftheiDRACissettouseastaticIPaddressorDHCP,runthefollowing
command:
platform bmc get source

ToseewhatIPaddressisassignedtotheiDRAC,runthefollowingcommand:
platform bmc show

TosettheiDRACtoastaticIPaddress,runthefollowingcommands:
platform bmc set ip [IP address]
platform bmc set netmask [netmask]
platform bmc set gateway [gateway]

Example:
platform bmc set ip 10.0.0.12
platform bmc set netmask 255.255.255.0
platform bmc set gateway 10.0.0.1

Note: OnadualcontrollerStorageCenter,changetheiDRACIPaddresson
bothSC8000controllers.

TosettheiDRACtouseDHCP,runthefollowingcommand:
platform bmc set source DHCP

NotethatDHCPmustbeenteredinallcaps.
126

Storage Center SC8000 Controller Deployment Guide

Verify Software Support for Enclosures

Verify Software Support for Enclosures


IftheStorageCenterhasoneormoreSC200/220orSC280enclosures,usethecommand
lineinterfacetoverifythatthecontrollerisrunningthecorrectStorageCenterOSversion.
Ifnecessary,upgradethecontrollerstoaversionthatsupportstheenclosures.
1 Atthecommandline,runthecommandcontroller show.
2 Intheoutputofthecommand,findthethreeVersioncolumns.
Version

Version

Version

06

04

01

Intheexampleabove,thecontrollerisrunningStorageCenterOS6.4.1.
3 Ifthecontrollerisrunningaversionolderthantheminimumversionspecifiedbelow,
upgradeStorageCenterOStotheminimumversionorlater.
Enclosure

Minimum Storage Center OS Version

SC200/220

6.2.1

SC280

6.4.1

a UseawebbrowsertoconnecttothemanagementIPofthecontroller.TheStorage
CenterStartupWizardappears.
b Acceptthelicenseagreement,thenclosetheStartupWizard.
c

UpdateStorageCenterOStothelatestversion.

IftheStorageCenterhasinternetconnectivity,usetheSystemManagerto
downloadandinstallthelatestStorageCenterOS.Forinstructions,seethe
StorageCenterSoftwareUpdateGuide.

IftheStorageCenterdoesnothaveinternetconnectivity,usetheStorageCenter
MaintenanceCDtoperformtheupgrade.SeetheStorageCenterMaintenanceCD
Instructionsdocumentfordetails.

4 AfterupdatingtheStorageCenterOS,checkforadditionalupdatesagain.Enclosure
firmwareupdatesmaynotinstallwiththeOSupdate,sinceStorageCenterdoesnot
recognizesomenewhardwareuntilaftertheOSisinstalled.
Note: WhenusingthenetworktoupgradeStorageCentertoOS6.4.1foran
SC280enclosure,theenclosurefirmwareupdatesmustbeinstalledseparately
afterStorageCenterOS6.4.1isinstalled.
ChecktheUpdateDetailswindowforEnclosureupdatesmarkedDeferrable,and
installthemnow.Theenclosurefirmwareupdatesmaytake2030minutes.Donot
interrupttheupdateafterithasstarted.
5 IfyouareconfiguringadualcontrollerStorageCenter,performsteps14onthesecond
controller.Firmwareupgradesshouldhaveinstalledwhenthefirstcontrollerwas
updated.
6 Afterbothcontrollersareupgradedtothelatestversion,logoutofSystemManagerand
logbackintocontinuewiththesetupprocess(seeStep 3onpage 128).

Dell Compellent

127

Chapter 5 Set up the Storage Center Software

Start the Storage Center Startup Wizard


UseawebbrowseronacomputerwithnetworkaccesstotheStorageCentertoaccess
StorageCenterSystemManagerandlaunchtheStartupWizard.

Prerequisites
YoumusthaveacomputerthathasconnectivitytotheStorageCentermanagement
interface.Thecomputermusthavethefollowingsoftwareinstalled:

Oneofthefollowingsupportedwebbrowsers(otherbrowsersandversionsmayhave
limitedcompatibility):

MicrosoftWindowsInternetExplorerVersions7,8,and9

MicrosoftWindowsInternetExplorer10onthedesktop(InternetExplorer10
Modernversionisnotsupported)

MozillaFirefoxonMicrosoftWindows

The32bit(x86)JavaRuntimeEnvironmentmustbeinstalledtorunStorageCenter
SystemManagerinany32bitbrowser.

Steps
1 Useasupportedwebbrowsertoconnecttotheeth0IPaddressorhostnameof
controller1.
2 Acknowledgeanysecuritymessages.
Note: Messagesthatappearmaydifferdependingonthebrowserused.(Click
ContinuetothiswebsiteinInternetExploreroraddasecurityexceptionin
Firefox.)
TheStorageCenterLoginpageappears.

3 Enterthedefaultusernameandpassword:

User:Admin

Password:mmm
Note: Theusernameandpasswordarecasesensitive.

4 ClickLogin.

128

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

5 Ifprompted,clickYestoacknowledgecertificatemessages.
TheStartupWizardappearsanddisplaystheSoftwareEndUserLicenseAgreement
(EULA).

Complete the Startup Wizard


UsetheStartupWizardtoconfiguretheStorageCenter.Thewizardcontainsthefollowing
pages.

License Agreement
UsetheLicenseAgreementpagetoreadandaccepttheSoftwareEndUserLicense
Agreement(EULA).
1 EnterinformationfortherequiredApprovingCustomerNameandApproving
CustomerTitlefields.Theapprovingcustomersnameandtitleandtheapprovaldate
arerecordedandsenttoDellTechnicalSupportServicesusingPhoneHome.
Note: TheEndUserLicenseAgreementisalsodisplayedthefirsttimeanynew
userlogsontotheStorageCenter.Whendisplayedforanewuser,theEULA
doesnotrequireacustomernameortitle.
2 AfterreadingtheEULA,clickAccepttocontinuewithsetup.TheLoadLicensepage
appears.

Dell Compellent

129

Chapter 5 Set up the Storage Center Software

Load the License File


UsetheLoadLicensepagetouploadtheStorageCenterlicensefile.Thelicensefilemakes
settingsavailabledependingonwhatfeatureswerepurchased.
1 Browsetothelocationofthelicensefile.
2 Verifythattheserialnumberofthelicensefilematchestheserialnumberofthe
controllerbycomparingthenameofthelicensefiletothetitlebaroftheStartupWizard.
Licensefilesusethenamingconventionsnxxx_35_date.lic,where:

snxxxistheserialnumberoftheStorageCenter.

35indicatesthatthesystemrunssoftwarehigherthanversion3.5.

dateshowsthelicensegenerationdateinYYMMDDformat.

.licisthefileextension.

3 Selectthelicensefile,thenclickLoadLicense.TheStartupWizarddisplaysamessage
whenthelicenseissuccessfullyloaded.

Ifthelicenseloadssuccessfully,themessageThelicensesubmissionhascompleted
successfullyappears.

IfthemessageError:Thelicensefileisnotvalidmessageisdisplayed,see
TroubleshootingLicensesonpage 206.

4 ClickContinue.

130

Ifstandarddrivesaredetected,theCreateDiskFolderpageappears.

IfSelfEncryptingDrives(SEDs)thatareFederalInformationProcessingStandard
(FIPS)1402certifiedaredetected,StorageCenterformatsthedrivesasifSecure
Datawillbeused,andyouareaskedwhethertocreateaSecureDatafolder.See
AboutSecureDataonpage 131.

IftheNodiskscouldbefoundmessageisdisplayed,seeTroubleshootingEnclosures
onpage 205.

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

About Secure Data


SecureDataisalicensedfeaturethatprovidesdataatrestencryptionwithkey
management.UsingSecureDatatomanageSEDsrequiresanexternalkeymanagement
server.Ifakeymanagementserverhasnotbeenconfiguredorisunavailable,youcan
manageFIPSSEDsintoaSecureDatafolder,howeverthedisksremaininapendingstate
untilthekeymanagementserverisavailable.
EachFIPSdiskinStorageCenterhasaninternalMediaEncryptionKey(MEK).Thekey
residesonthedisk,providingencryptionfordatawrittentothediskanddecryptionfor
dataasitisreadfromthedisk.Destroyingthekeymakesanydataonthediskimmediately
andpermanentlyunreadable,aprocessreferredtoasacryptoerase.WhenyouaddanSED
to,orreleaseanSEDfromaSecureDatafolder,theMEKisdestroyedandanewkeyis
generated.Thisallowsthedisktobereused,althoughallpreviousdataislost.
Note: BecausedisksthatcontainuserdatacannotbemovedfromaSecureData
folder,StorageCenterdoesnotcryptoerasedisksthatcontainuserdata.
Toprotectdataatrest,allSEDsinaSecureDatadiskfolderlockwhenpowerisremoved
(LockonResetenabled).Whenpowerisremovedfromthedrive,thedrivecannotbe
unlockedwithoutaccesstotheauthoritycredentialstoredinthekeymanagementserver.

Dell Compellent

131

Chapter 5 Set up the Storage Center Software

Create a Disk Folder


UsetheCreateDiskFolderpagestoassigndiskstoafolderinordertocreateasinglepool
ofstorageforvolumes.

1 Selectdisksforthediskfolder.Bydefault,theStartupWizardselectsallavailable
disks.
Note: ASecureDatafoldercanonlycontainselfencryptingFIPSdrives,which
areindicatedbyayellowlockicon.
a ScrollthroughthelistlookingattheEnclosurecolumnandthePositionorName
columntoverifythatalltheexpectedenclosuresanddisksarelisted.
Ifenclosuresordisksaremissing,theissuesmightbefixedbyfollowing
TroubleshootingEnclosuresonpage 205.
b (Optional)Fromthelistofdisks,selectdiskstoincludeinthediskfolder.Bydefault,
alldisksareselected.

Toexcludeindividualdisksfromthediskfolder,clearthecorrespondingcheck
boxes.

Toincludeindividualdisksinthediskfolder,clickUnselectAllandthenselect
theindividualdiskstoinclude.

Toselectalldisks,clickSelectAll.
Note: Dell Compellentrecommendsselectingallavailablediskstomaximize
thebenefitsofDataProgression.

132

ClickContinue.TheStartupWizarddisplaysaprompttoselectdiskstodesignate
ashotspares.

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

2 ReviewthehotsparedisksautomaticallyselectedbytheStartupWizard.
Ahotsparediskisheldinreserveuntiladiskfails,atwhichpointthehotsparereplaces
thefaileddisk.Thehotsparediskmustbeaslargeorlargerthanthelargestdiskofits
typeinthediskfolder.Forredundancy,theremustbeatleastonehotspareforeach
enclosure.
Ingeneral,SystemManagerusesthefollowingbestpracticesindesignatinghotspares:

For2Uenclosures,onesparediskforeverydiskclass(10K,7.5K,andsoon).

For5Uenclosures,onesparediskforevery21disks,howevernosinglerowwill
containmorethanonesparedisk.

a (Optional)Changetheselectionbyselectingorclearingdiskstobeusedashot
spares.
b ClickContinue,andifprompted,clickOKtoconfirm.TheStartupWizarddisplays
asummaryofthediskfolderthatwillbecreated.

Dell Compellent

133

Chapter 5 Set up the Storage Center Software

3 (Optional)ModifythedefaultfoldernameandenteradescriptionintheNotesfield.
4 (Optional)ClickAdvancedtoconfigureadvanceddiskfolderoptions.Thewizard
displaysoptionsforredundancyanddatapagesize.
Note: Thedefaultmanageddiskfoldersettingsareappropriateformostsites.If
youareconsideringchangingthedefaultsettings,contactDellTechnical
SupportServicesforadvice.

a SelectPrepareDiskFolderforredundantstorage.

134

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

b ConfiguretheTierRedundancyforeachtier.
Theredundancylevelforeachtierdefaultstoeithersingleredundantordual
redundantdependinguponthedisksexpectedtobefoundinthetier.Ifatier
containsatleastsixmanageddisksofwhichoneis900GBorgreater,thenthattier
andalltiersbelowitaresettodualredundantstoragebydefault.Ifatiercontains
atleastsixmanageddisksof1.8TBorgreater,thenthattierandalltiersbelowitare
settodualredundantstorageandcannotbechanged.
Singleredundantstorageprotectsagainstthelossofanyonedrive.

RAID10(eachdiskismirrored)

RAID55(4datasegments/1paritysegmentperstripe)

RAID59(8datasegments/1paritysegmentperstripe)

Dualredundantstorageprotectsagainstthelossofanytwodrives:

RAID10DualMirror(dataiswrittensimultaneouslytothreeseparatedisks)

RAID66(4datasegments/2paritysegmentsperstripe)

RAID610(8datasegments/2paritysegmentsperstripe)

FromtheDatapageSizedropdownmenu,chooseadatapagesize.

2MB:(Default)Recommendedformostapplicationneeds.

512KB:Appropriateforapplicationswithhighperformanceneeds(suchas
certaindatabases)orenvironmentsinwhichReplaysaretakenfrequentlyunder
heavyIO.SelectingthissizereducestheamountofspacetheSystemManager
canpresenttoservers.

4MB:Appropriateforsystemsthatusealargeamountofdiskspacewith
infrequentReplays(suchasvideostreaming).
Caution: Whenconsideringusingeitherthe512KBor4MBdatapage
settings,itisrecommendedthatyoucontactDellTechnicalSupportServices
foradviceonbalancingresourcesandtounderstandtheimpacton
performance.

d ToconfigurethediskfoldertouseRAID0,selectthePrepareforNonRedundant
Storagecheckbox.Nonredundantstoragedoesnotprotectdataintheeventofa
diskfailure.Selectthisoptiononlyfordatathatisbackedupsomeotherway.
e ClickContinue.Thediskfoldersummaryappears.
5 ClickCreateNow,andifprompted,clickOKtoconfirm.TheAddControllerpage
appears.

Dell Compellent

135

Chapter 5 Set up the Storage Center Software

Add a Controller
UsetheAddControllerpagestoconfigurethesecondcontrollerandtoentertheIPv6
address,ifused,ontheleadercontroller.

1 ProceedbasedonthenumberofcontrollersintheStorageCenter.

136

SinglecontrollerStorageCenter:ClickContinueSetup.TheTimeSettingspage
appears.

DualcontrollerStorageCenter:ClickAddController.Thewizardpromptsyouto
enterIPv6addressinformationforthefirst(Leader)controller.

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

2 ProceedbasedonwhetheryouuseIPv6forcontrolleraddressing.
a IfIPv6isused,enterIPv6informationforthefirstcontrollerandclickContinue.
b IfIPv6isnotused,clickSkipIPv6Configuration.
Note: Informationdisplayedinthefollowingfigureisforillustrationonly.
ThevaluesdisplayedareuniquetoeachStorageCenter.

3 Configurethefollowingfields:

ControllerID:IftheHSNforController2isincludedinthelicensefile,theadd
controllerprocessusesthatvalueastheControllerIDandadifferentvaluecannot
beentered.IftheHSNforController2isnotinthelicensefile,entertheHSNvalue.
ThedimmedboxintheprecedingfigureindicatesthattheHSNwasinthelicense
filemakingtheControllerIDboxunavailable.

Ether0Interface:EntertheIPAddress,NetMask,andGatewayfortheEther0
interfaceonController 2.

Ether1Interface:EntertheIPAddress,NetMask,andGatewayfortheEther1
interface.UsetheIPaddressfromthecontroller showconsolecommandfor
Controller2.(Usedforcommunicationbetweencontrollers.)

PrimaryDNSServer:EntertheIPaddressoftheprimaryDNSserver.

SecondaryDNSServer:(Optional)EntertheIPaddressofasecondaryDNSserver.

DomainName:(Optional)Enterthedomainnameforthecontroller.

4 ClickContinue.
TheStartupWizarddisplaysamessagethatdataandconfigurationinformationonthe
secondcontrollerislostandasksforconfirmation.

Dell Compellent

137

Chapter 5 Set up the Storage Center Software

5 ClickJoinNow.Waitfortheprocesstocompleteandforthecontrollertoreboot,which
cantakeafewminutes.Whencomplete,theTimeSettingspageappears.

Set the Time


UsetheTimeSettingspageistosetthesystemtimefortheStorageCenter.

1 Setthetimezone.
a FromtheRegiondropdownmenu,selectthegeographicalregioninwhichthe
StorageCenterislocated.
b FromtheTimeZonedropdownmenu,selectthetimezoneinwhichtheStorage
Centerislocated.

138

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

Note: ForlocationsintheUnitedStates,eitherselectUSastheregionandselect
atimezonename,orselectAmericaastheregionandselectacitywithinthe
sametimezone.
2 Setthesystemtimeusingoneofthefollowingmethods.

Toconfiguretimemanually,selectConfigureTimeManually,thenenterthedate
andtime.

ToconfiguretimeusingaNetworkTimeProtocol(NTP)server,selectUseNTP
TimeServer,thenenterthefullyqualifieddomainname(FQDN)orIPaddressof
anNTPserver.
Note: Accuratetimesynchronizationiscriticalforreplications.DellCompellent
recommendsusingNTPtosetthesystemtime.Formoreinformation,see:
support.ntp.org/bin/view/Support/WebHome.

3 Whenthesystemtimehasbeenset,clickContinue.TheSystemSetuppageappears.

Set the System IP Address


UsetheSystemSetuppagethesystemnameandmanagementIPaddressfortheentire
StorageCenter(oneormorecontrollersandoneormoreenclosures).

1 IntheSystemNamefield,enteranamefortheStorageCenter.Thisistypicallythe
serialnumberofController1.
2 (Dualcontrolleronly)IntheManagementIPAddressfield,enterthemanagementIP
addressspecifiedinthepreinstallationdocuments.(Onsinglecontrollersystems,this
fieldisnotdisplayedandthemessageatthetopofthepanereadssimply,Setthe
Systemsname.)
ThemanagementIPaddressisdistinctfromthecontroller1andcontroller2addresses.
ItistheaddressthatmanagesadualcontrollerStorageCenterasawhole.Ifeither
controllerfails,themanagementIPaddressremainsvalid.

Dell Compellent

139

Chapter 5 Set up the Storage Center Software

3 ClickContinue.Thewizardpromptsyoutoenableordisablethereadandwritecache.

4 Selectorclearthecheckboxestoenableordisablereadandwritecache.
Note: Disablecacheonlyifnovolumeswilleverusecache.Ifcacheisleft
enabledonthispage,itcanbedisabledlaterforindividualvolumes.Seethe
StorageCenterSystemManagerAdministratorsGuideforinformationondisabling
cacheonavolumebyvolumebasis.
5 ClickContinue.

140

IfaSecureDatafolderisusedwithFIPSSEDs,youarepromptedtoconfigureakey
managementserver.

ifstandarddrivesareused,theConfigureSMTPpageappears.

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

Configure a Key Management Server


UsingSecureDatatomanageSelfEncryptingDrives(SEDs)requiresanexternalkey
managementserver.Establishaconnectiontoanexistingkeymanagementserverinthis
step.
Note: Thekeymanagementservermustbeavailabletomanagenewself
encryptingFIPSdisksintoaSecureDatafolderthathasalreadybeenintheSecure
state.

1 EntertheHostnameorIPaddressofthekeymanagementserver,theportnumberto
use,andacommunicationtimeoutvalue.
2 (Optional)Enterthenameofthehostorhoststouseiftheprimaryhostisunavailable.
3 Ifthekeymanagementserverisconfiguredtovalidatetheclientcertificate,enterthe
keymanagementcredentialsintheClientUsernameandClientPasswordboxes.
4 ClickContinue.ThenextpageofthewizardprovidesinformationabouttheSSL
certificatefilesrequiredtocommunicatewiththekeymanagementserver.Thenext
pageofthewizardprovidesinformationabouttheSSLcertificatefilesrequiredto
communicatewiththekeymanagementserver.Thecertificatefilesaregeneratedby
yoursystemadministrator;theyarenotsuppliedbyDell Compellent.
5 ClickUploadClientCerts.
6 Navigatetoandselecttheexistingpublickey(*.pem)file.
7 ClickContinue.
8 RepeatStep 5throughStep 7forthesecondcontroller(ifpresent).
9 ClickUploadCertstoreCert.
10 Navigatetoandselecttheexistingpublickey(*.pem)file.
11 ClickContinue.Thelastpageofthewizardappears.
12 ClickFinishNow.TheConfigureSMTPpageappears.

Dell Compellent

141

Chapter 5 Set up the Storage Center Software

Configure SMTP
UsetheConfigureSMTPpagetoconfiguretheSMTPmailserverandthesenderemail
address.Thisconfigurationenablesalertmessageemailstobesenttouserswhohave
specifiedarecipientaddressintheircontactproperties.
Note: ToconfigureSMTPlater,clickSkipSMTPConfiguration.SMTPsettingscan
beconfiguredlaterintheSystemManagerthroughtheStorageManagement
menu.

1 IntheSMTPMailServerfield,entertheIPaddressorfullyqualifieddomainnameof
theSMTPemailserver.ClickTestservertoverifyconnectivitytotheSMTPserver.
2 IntheSenderEmailAddressfield,entertheemailaddressofthesender.Thisaddress
isrequiredbymostSMTPserversandisusedastheMAILFROMaddressofemail
messages.

142

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

3 (Optional)ClickAdvancedtoconfigureadditionalSMTPsettingsforsitesthatusean
advancedSMTPconfiguration.Thepageforadvancedoptionsappears.

a VerifythattheEnableSMTPEmailcheckboxisselected.
b IntheSMTPMailServerfield,verifytheIPaddressorfullyqualifieddomainname
oftheSMTPmailserverthatyouenteredinStep 1onpage 142.Modifythisfieldif
necessary.
c

IntheBackupSMTPMailServerfield,entertheIPaddressorfullyqualified
domainnameofthebackupSMTPmailserver.

d ClickTestservertotesttheconnection(s).
e IntheSenderEmailAddress(MAILFROM)field,verifytheemailaddressofthe
senderthatyouenteredinStep 2onpage 142.Modifythisfieldifnecessary.
f

IntheCommonSubjectLinefield,enteracommonsubjectlineforallemailsfrom
StorageCenter.

g (Optional)SelectSendExtendedHello(EHLO)toconfigureuseofextendedhello
formailsystemcompatibility.
InsteadofbeginningthesessionwiththeHELOcommand,thereceivinghostissues
theHELOcommand.Ifthesendinghostacceptsthiscommand,thereceivinghost
thensendsitalistofSMTPextensionsitunderstands,andthesendinghostthen
knowswhichSMTPextensionsitcanusetocommunicatewiththereceivinghost.
ImplementingExtendedSMTP(ESMTP)requiresnomodificationoftheSMTP
configurationforeithertheclientorthemailserver.
h (Optional)SelectUseAuthorizedLogin(AUTHLOGIN)andentertheLoginID
andPasswordiftheemailsystemrequirestheuseofanauthorizedlogin.
4 ClickContinue.TheUpdateSetuppageappears.

Dell Compellent

143

Chapter 5 Set up the Storage Center Software

Select Update Option


UsetheUpdateSetuppagetoconfigurehowStorageCenterhandlessoftwareupdates.

1 Selectanupdateoptionfromthedropdownmenu:

Donotautomaticallycheckforsoftwareupdates:Selectthisoptiontodisable
automaticcheckingforupdates.Ifthisoptionisselected,thefollowingisstill
available:

ManuallycheckforupdatesbyselectingStorageManagementSystem
UpdateCheckforUpdateasdescribedintheStorageCenterSystemManager
AdministratorsGuide.

ChangeupdateoptionsbyselectingStorageManagementSystem
UpdateConfigureAutomaticUpdatesasdescribedintheStorageCenter
SystemManagerAdministratorsGuide.

Notifymeofasoftwareupdatebutdonotdownloadautomatically:Selectthis
optiontoautomaticallycheckforupdatesandreceivenotificationwhenanupdate
isavailable.Updatesarenotdownloadeduntilyouexplicitlydownloadtheupdate.
(Thisisthedefaultsetting.)

Downloadsoftwareupdatesautomaticallyandnotifyme:Selectthisoptionto
automaticallydownloadupdatesandreceivenotificationwhenthedownloadis
complete.

Nevercheckforsoftwareupdates(PhoneHomenotavailable):Selectthisoption
topreventthesystemfromevercheckingforupdates.Thisoptionisforsecuresites
atwhichPhoneHomeisnotavailable.

2 ClickContinue.TheUserSetuppageappears.

144

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

Set Admin Account


UsetheUserSetuppagetothesessiontimeoutandemailaddressesfortheAdmin
account.

3 FromtheSessionTimeoutdropdownlist,selectthesessiontimeout.
4 IntheEmail,Email2,andEmail3fields,enteremailaddressestowhichtheStorage
Centersendssystemalerts.
5 (Optional)ClickSendtestemailtomakesurethattheemailaddressesareaccurate.
Note: Makesurethattheadministratorreceivesthetestemail(s).StorageCenter
usesemailtosendsystemalerts.
6 ClickContinue.

Dell Compellent

IftheStorageCenterhasiSCSIIOcards,theConfigureIOCardspageappears.

IftherearenoiSCSIIOcards,theConfigurePortspageappears.

145

Chapter 5 Set up the Storage Center Software

Configure IO Cards
TheConfigureIOCardspageappearsiftheStorageCenterdetectsiSCSIIOcards.Usethis
pagetoconfigurenetworksettingsforiSCSIIOcards.

1 (Optional)ClickSkipiSCSIIOCardConfigurationtoconfigurenetworksettingsfor
theiSCSIIOcardslater.TheConfigurePortspageappears.
Note: DellCompellentrecommendsthatyouconfigureiSCSIIOcardsduring
setup.
2 ForeachiSCSIIOcardthatisused,completetheIPAddress,aSubnetMask,and
Gatewayfields.UninitializediSCSIIOcardshaveanIPAddressof0.0.0.0andwillbe
listedonawarningspageinthenextstep.
3 Whenyouarefinished,clickContinue.

146

Ifnomessagesaregenerated,iSCSIIOcardconfigurationissavedandthe
ConfigurePortspageappears.

Ifthereareissues,amessageappears.

ClickNotogobackandcorrecttheIPAddress,SubnetMask,and/orGateway
addressforcardsthatgeneratederrorsand/orwarnings.

ClickYestoignorethemessageandcontinue.TheConfigurePortspageappears.

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

Configure Ports
UsetheConfigurePortspagetoconfigurethefrontendandbackendports.

Select the Front-End Connectivity Mode(s)


Selectthefrontendconnectivitymodeforeachtransporttype(FCand/oriSCSI).Ifvirtual
portmodeislicensed,thetransporttypescanbeconfiguredtousedifferentmodes.If
virtualportmodeisnotlicensed,alltransporttypesmustuselegacymode.
If

Then

VirtualPortsisNotLicensed

AlltransporttypesuseLegacyMode.Inthiscase,theStartup
WizarddisplaystheInitialPortConfigurationpage.To
continue,gotoConfigurePortsWhenVirtualPortModeIsNot
Licensedonpage 147.

VirtualPortsisLicensed

FCandiSCSItransporttypescanuselegacymodeorvirtualport
mode.Inthiscase,theStartupWizarddisplaysanoperational
modechoicepagethatallowsforthechoicebetweenmodesfor
eachsupportedtransporttype.Tocontinue,gotoConfigure
PortsWhenVirtualPortModeIsLicensedonpage 149.

Note: ToskipportinitializationorifthereisnoFCswitchsetup,clickSkipPort
Initialization.

Configure Ports When Virtual Port Mode Is Not Licensed


IfVirtualPortsisnotlicensed,thewizardinformsyouthatthelocalportshavenotbeen
configured.

1 ClickContinuetogeneratetheinitialportconfiguration.
Whiletheinitialportconfigurationisbeinggenerated,theStartupWizarddisplaysa
pageshowingprogress.Aftertheconfigurationhasbeengenerated,itisautomatically
validated.

Dell Compellent

147

Chapter 5 Set up the Storage Center Software

Ifthevalidationissuccessful,aconfirmationpageappearsstatingthattheport
configurationhasbeengenerated.

Ifthevalidationfails,apagedisplayingwarningsappears.

2 ClickConfigureLocalPorts.ThewizarddisplaysatabforeachtypeofIOcardthatis
installedintheStorageCenter(FC,iSCSI,andSAS).

3 ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.See
ConfigureLocalPortsonpage 154.
4 Whenyouarefinishedconfiguringthelocalports,clickAssignNow.Thewizard
informsyouthattheportconfigurationhasbeengenerated.

148

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

5 ClickContinue.TheGenerateSSLCertpageappears.

Configure Ports When Virtual Port Mode Is Licensed


IfVirtualPortsislicensed,thewizardinformspromptsyoutochoosethefrontend
connectivitymode(s)fortheavailabletransporttypes(FCand/oriSCSI).

1 Selectthefrontendconnectivitymode(s).
a SelecttheoperationalmodeforFCandiSCSItransports.
b ClickContinuetoconfiguretheselectedoperationalmode(s).Thewizardinforms
youthattheoperationalmodeshavebeenconfigured.

Dell Compellent

149

Chapter 5 Set up the Storage Center Software

ClickContinuetobeginportinitializationintheselectedoperationalmode(s).
Thewizardverifiestheconfiguration,convertsselectedtransportstotheselected
mode,displaysprogresspages,andpresentsaconfirmationpagewhenoperational
modesfortransporttypeshavebeenconfiguredandinitialized.

150

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

d ClickContinue.ThepagethatappearsnextdependsonwhetherthereareanyiSCSI
transportsinvirtualportmode:

iSCSIinvirtualportmode:ArequestisdisplayedtoprovidetheIPaddress
informationrequiredtocreatethedefaultiSCSIFaultDomain.GotoStep 2on
page 151.

iSCSIinlegacyportmode(ornoiSCSIports):Whiletheinitialport
configurationisbeinggenerated,theStartupWizarddisplaysapageshowing
progress.Aftertheconfigurationhasbeengenerated,itisautomatically
validated.Ifthevalidationissuccessful,theconfirmationpageappears.Ifthere
areissues,apageappearslistingerrormessages.GotoStep 3onpage 152.

2 (iSCSIvirtualportmodeonly)ConfigurethecontrolportfortheiSCSIfaultdomain.

a EntertheIPaddress,netmask,gateway,andportforthecontrolportforthenew
iSCSIfaultdomain.Checkthepreinstallationdocumentationforthisaddress.
b ClickContinue.
TheStartupWizardgeneratesthenewiSCSIfaultdomainandtheinitialport
configuration.Whiletheinitialportconfigurationisbeinggenerated,theStartup
Wizarddisplaysapageshowingprogress.Aftertheconfigurationhasbeen
generated,itisautomaticallyvalidated.

Dell Compellent

Ifthereareissues,anerrormessagepageappears.

Ifthevalidationissuccessful,aconfirmationpageappears.

151

Chapter 5 Set up the Storage Center Software

3 ClickConfigureLocalPorts.ThewizarddisplaysatabforeachtypeofIOcardthatis
installedintheStorageCenter(FC,iSCSI,andSAS).

4 ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.See
ConfigureLocalPortsonpage 154.
5 Whenyouarefinishedconfiguringthelocalports,clickAssignNow.Thewizard
informsyouthattheportconfigurationhasbeengenerated.

152

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

6 ClickContinue.TheGenerateSSLCertpageappears.

Dell Compellent

153

Chapter 5 Set up the Storage Center Software

Configure Local Ports


ConfigurethePurpose,FaultDomain,andUserAliasforalltransporttypes.Validport
purposesfortransporttypesdependonwhethervirtualportsmodeislicensedonStorage
Center.

ConfigureFCPortsLegacyModeonpage 154

ConfigureFCPortsVirtualPortModeonpage 156

ConfigureiSCSIPortsLegacyModeonpage 157

ConfigureiSCSIPortsVirtualPortModeonpage 158

ConfigureSASPortsonpage 159

Thefollowingtableshowstheportpurposesforeachtransporttype.
Port Purpose

Transport Type

Description

FC,iSCSI,andSAS

Oneofthefollowing:

Legacy Mode
Unknown

Portpurposeisnotyetdefined.
Theportisunused.
(SASandFConly)Theportisusedfordirect
connectinterprocesscommunication(IPC).
FrontEndPrimary

FCandiSCSI

Portisconnectedtoserversandisusedfortheserver
IOpath.

FrontEndReserved

FCandiSCSI

Portisconnectedtoserversandusedasafailover
path.OnlyusedfordualcontrollerStorageCenters.

BackEnd

FCandSAS

Portisconnectedtodiskenclosures.

DirectConnect

FCandiSCSI

Thisportpurposeisnotused.Donotselectitforany
ports.

FC,iSCSI,andSAS

Oneofthefollowing:

Virtual Port Mode


Unknown

Portpurposeisnotyetdefined.
Theportisunused.
(SASandFConly)Theportisusedfordirect
connectinterprocesscommunication(IPC).
FrontEnd

FCandiSCSI

Portisconnectedtoserversandisusedfortheserver
IOpath.

BackEnd

FC

Portisconnectedtodiskenclosures.

Configure FC Ports Legacy Mode


UsetheFCtabtoconfiguretheFibreChannelportsinlegacymode.
1 ClicktheFCtab.

154

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

2 Createtherequiredfaultdomains.ForadualcontrollerStorageCenter,createafault
domainforeachpairofredundantFCports.ForasinglecontrollerStorageCenter,
createasinglefaultdomainforallFCports.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfault
domains.
b ClickCreateFaultDomain.Adialogboxappears.
c

IntheNamefield,typeanameforthefaultdomain.

d FromtheTypedropdownmenu,selectFC.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f

ClickContinue.Thedialogboxdisplaysasummary.

g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i

Whenyouarefinishedcreatingfaultdomains,clickReturn.TheFCtabappears.

3 ConfigureeachbackendFCport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

4 ConfigureeachfrontendFCport.
a SetthePurposefieldtoFrontEndPrimaryorFrontEndReservedasappropriate.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

5 ConfigureeachportthatisunusedorusedforIPCbetweencontrollers.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

Dell Compellent

(Optional)TypeadescriptivenameintheUserAliasfield.

155

Chapter 5 Set up the Storage Center Software

Configure FC Ports Virtual Port Mode


UsetheFCtabtoconfiguretheFibreChannelportsinvirtualportmode.
1 ClicktheFCtab.

2 CreateafaultdomainforeachFCfabric.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfault
domains.
b ClickCreateFaultDomain.Adialogboxappears.
c

IntheNamefield,typeanameforthefaultdomain.

d FromtheTypedropdownmenu,selectFC.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f

ClickContinue.Thedialogboxdisplaysasummary.

g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i

Whenyouarefinishedcreatingfaultdomains,clickReturn.TheFCtabappears.

3 ConfigureeachbackendFCport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

4 ConfigureeachfrontendFCport.
a SetthePurposefieldtoFrontEnd.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

5 (Optional)Changethepreferredphysicalportforoneormorevirtualports.
a ClickEditVirtualPorts.Thewizarddisplaysalistofvirtualports.
b Foreachvirtualportthatyouwanttomodify,selectthepreferredphysicalportIn
thePreferredPhysicalPort.

156

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

Whenyouarefinished,clickApplyChanges.TheiSCSItabappears.

6 ConfigureeachportthatisunusedorusedforIPCbetweencontrollers.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

Configure iSCSI Ports Legacy Mode


UsetheiSCSItabtoconfiguretheiSCSIportsinlegacymode.
1 ClicktheiSCSItab.

2 Createtherequiredfaultdomains.ForadualcontrollerStorageCenter,createafault
domainforeachpairofredundantiSCSIports.ForasinglecontrollerStorageCenter,
createasinglefaultdomainforalliSCSIports.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfault
domains.
b ClickCreateFaultDomain.Adialogboxappears.
c

IntheNamefield,typeanameforthefaultdomain.

d FromtheTypedropdownmenu,selectiSCSI.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f

ClickContinue.Thedialogboxdisplaysasummary.

g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i

Whenyouarefinishedcreatingfaultdomains,clickReturn.TheiSCSItabappears.

3 ConfigureeachfrontendiSCSIport.
a SetthePurposefieldtoFrontEndPrimaryorFrontEndReservedasappropriate.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c

Dell Compellent

(Optional)TypeadescriptivenameintheUserAliasfield.

157

Chapter 5 Set up the Storage Center Software

4 Confirmthatunusedportsarenotconfigured.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

Configure iSCSI Ports Virtual Port Mode


UsetheiSCSItabtoconfiguretheiSCSIportsinvirtualportmode.
1 ClicktheiSCSItab.

2 CreateafaultdomainforeachiSCSInetwork.
a ClickEditFaultDomains.Thewizarddisplaysalistofthecurrentlydefinedfault
domains.
b ClickCreateFaultDomain.Adialogboxappears.
c

IntheNamefield,typeanameforthefaultdomain.

d FromtheTypedropdownmenu,selectiSCSI.
e (Optional)IntheNotesfield,typeadescriptionofthefaultdomain.
f

ClickContinue.Thedialogboxdisplaysasummary.

g ClickCreateNowtocreatethefaultdomain.
h Repeatstepsbgasneededtocreateadditionalfaultdomains.
i

Whenyouarefinishedcreatingfaultdomains,clickReturn.TheiSCSItabappears.

3 ConfigureeachfrontendiSCSIport.
a SetthePurposefieldtoFrontEnd.
b SettheFaultDomainfieldtotheappropriatefaultdomainthatyoucreated.
c

158

(Optional)TypeadescriptivenameintheUserAliasfield.

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

4 (Optional)Changethepreferredphysicalportforoneormorevirtualports.
a ClickEditVirtualPorts.Thewizarddisplaysalistofvirtualports.
b Foreachvirtualportthatyouwanttomodify,selectthepreferredphysicalportIn
thePreferredPhysicalPort.
c

Whenyouarefinished,clickApplyChanges.TheiSCSItabappears.

5 Confirmthatunusedportsarenotconfigured.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

Configure SAS Ports


ConfigurethebackendSASports.
1 ClicktheSAStab.

2 ConfigureeachbackendSASport.
a SetthePurposefieldtoBackEnd.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

(Optional)TypeadescriptivenameintheUserAliasfield.

3 ConfigureeachportthatisunusedorusedforIPCbetweencontrollers.
a SetthePurposefieldtoUnknown.
b ConfirmthattheFaultDomainfieldissetto<none>.
c

Dell Compellent

(Optional)TypeadescriptivenameintheUserAliasfield.

159

Chapter 5 Set up the Storage Center Software

Generate SSL Certificate


UsetheGenerateSSLCertpagetogenerateanewSecureSocketLayer(SSL)certificateor
importanexistingcertificatefortheStorageCenter.TheSSLcertificatemustmatchthe
StorageCentersIPAddressorDNShostname.
TheinitialcertificateshippedwiththeStorageCentermaynotmatchtheIPaddressor
DNShostnameassignedtotheStorageCenter.Ifso,whenconnectingtoStorageCenter,a
messageisdisplayedidentifyingamismatchbetweenthecertificateandtheIPaddressor
DNShostnameoftheStorageCenter.Importorgenerateacertificatetocorrectthe
mismatch.
Caution: DonotclickSkiptobypassthispage.ClickingSkipcanresultin
connectiondisruptionstoStorageCenterSystemManager.

Import a Certificate
IfanSSLcertificatehasalreadybeengenerated,importthecertificate.

Prerequisites
Thepublickeyfilemustbeinx.509format.

160

Storage Center SC8000 Controller Deployment Guide

Complete the Startup Wizard

Steps
1 ClickImport.Afilebrowserappears.

2 Browsetothelocationofthepublickey(*.pem)fileandselectit.
3 ClickNext.
4 Browsetothelocationoftheprivatekeyfile(*.pem).
5 ClickNext.ASummarypageappearsthatidentifiesthekeyfilesselected.
6 ClickSavetoimportthecertificates.

Dell Compellent

161

Chapter 5 Set up the Storage Center Software

Create a New Certificate


IfyoudonotalreadyhaveacertificatethatcontainstheStorageCenterhostnameorIP
address,generateonenow.
1 ClickGenerate.ThewizardpromptsyoutoentertheIPaddressesandhostnamesfor
theStorageCenter.

2 Inthetextfield,enterallDNShostname(s),IPv4address(es),andIPv6address(es)for
thisStorageCenter,separatedbycommas.Thewizardprepopulatesthefieldwith
informationitknows,butitislikelythatmoresitespecifichostnamesandaddresses
needtobeentered.
Caution: Thehostname(s)andaddress(es)mustmatchthisStorageCenteror
youwillnotbeabletoreconnecttoit.
3 ClickGenerateNow.Anewcertificateisgeneratedandthesessionends.Tocontinue,
refreshthebrowserandlogontotheStorageCenteragain.

162

Storage Center SC8000 Controller Deployment Guide

Label SC200 and SC220 Enclosures

Label SC200 and SC220 Enclosures


SC200andSC220enclosuresdonothavedisplaystoindicatetheenclosureIDassignedby
StorageCentersoftware.Tofacilitateeasyidentificationintherack,useStorageCenter
SystemManagertomatcheachenclosureIDtoaServiceTag.LocatetheServiceTagonthe
backofeachenclosureandthenlabelitwiththecorrectenclosureID.
Note: IftheenclosureisdeletedfromSystemManager,andthenaddedbackin,it
isassignedanewindexnumber,requiringalabelchange.
1 UsetheStorageCenterSystemManagertomapeachenclosureIDtoaServiceTag.
a FromtheSystemTree,expandtheEnclosuresnode.
b Selectanenclosure.
c

OntheGeneraltab,locateandrecordtheIndexandServiceTag.

2 CreatealabelforeachSC200/SC220enclosurewiththeenclosureIDnumber.

Dell Compellent

163

Chapter 5 Set up the Storage Center Software

3 ApplyanIDlabeltotheleftfrontofeachenclosure.

ID 01

Figure 110. SC200 and SC220 Enclosure Labels

164

Storage Center SC8000 Controller Deployment Guide

Perform Post-Setup Tasks


Performconnectivityandfailoverteststomakesurethatthedeploymentwassuccessful,
thenchangeadministrativepasswords,PhoneHome,andcheckforupdates.

Contents
VerifyConnectivityandFailover ............................................. 165
ConfigureaPhoneHomeProxy .............................................. 170
PhoneHome ............................................................... 170
CheckforStorageCenterUpdates ............................................ 172
NextSteps ................................................................. 172

Verify Connectivity and Failover


ThissectiondescribesthegeneralstepsneededtoverifythatStorageCenterissetup
properlyandfailsovercorrectly.Theprocessincludesconnectingaserverandcopying
datatoverifyconnectivity,andshuttingdownacontrollertoverifyfailoverandMPIO
functionality.Fordetailsabouteachstep,refertotheStorageCenterSystemManager
AdministratorsGuide.

Create Test Volumes


ConnectaservertotheStorageCenter,createoneormoretestvolumes,andmapthemto
theservertoprepareforconnectivityandfailovertesting.
1 ConnectaservertotheStorageCenterusingFibreChanneloriSCSI.
2 (iSCSIonly)ConfiguretheiSCSIinitiatorontheservertotargettheStorageCenter.
3 UseawebbrowsertoloadtheStorageCenterSystemManager.

SinglecontrollerStorageCenter:EnterthecontrollermanagementIPaddress

DualcontrollerStorageCenter:EnterthesharedsystemmanagementIPaddress.

4 LogintoSystemManager.
5 DefinetheserverinSystemManager.
a IntheSystemTree,selectServers.
b ClickCreateServer.TheCreateServerwizardappears.
c

SelecttheserverHBA(s)inthetable,thenclickContinue.

d IntheNamefield,typeanamefortheserver.
e FromtheOperatingSystemdropdownmenu,selecttheoperatingsystemthatthe
serverisrunning.

Dell Compellent

165

Chapter 6 Perform Post-Setup Tasks

ClickContinue.Thewizarddisplaysasummary.

g ClickCreateNow.Thewizarddisplaysalistofoptionalactions.
h ClickClose.Thewizardcloses.
6 Createa25GBtestvolumecalledTestVol1.
a IntheSystemTree,selectVolumes.
a IntheCreateServerwizard,clickCreateVolume.theCreateVolumewizard
appears.
b Setthevolumesizeto25GB,thenclickContinue.
c

ClickContinuetoapplythedefaultReplayProfile.

d TypeTestVol1intheNamefield,thenclickContinue.Thewizarddisplaysa
summary.
e ClickCreateNow.Thewizarddisplaysalistofoptionalactions.
f

ClickClose.

7 (Dualcontrolleronly)RepeatStep 6tocreateasecondtestvolumenamedTestVol2.
8 MapTestVol1tothefirstcontroller.
a IntheSystemTree,expandtheVolumesnode.
b SelectTestVol1.
c

ClickMapVolumetoServer.TheMapVolumetoServerwizardappears.

d Selecttheserver,thenclickContinue.Thewizarddisplaysasummary.
e ClickAdvanced.Thewizarddisplaysadvancedmappingoptions.
f

IntheRestrictMappingPathsarea,selecttheMaptocontrollercheckbox,then
selectthecontrollerfromthedropdownmenu.

g ClickContinue.Thewizarddisplaysasummary.
h ClickCreateNow.Themappingiscreatedandthewizardcloses.
9 (Dualcontrolleronly)RepeatStep 8tomapTestVol2tothesecondcontroller.
10 Ontheserver,partitionandformatthetestvolume(s).

Test Connectivity and Failover


Copydatatothetestvolumeandsimulatefailurestotestconnectivityandfailover.

Test Basic Connectivity


Verifyconnectivitybycopyingsomedatatothetestvolume(s).

Test Controller Failover


IftheStorageCenterhasdualcontrollers,performatesttomakesurethatIOisnot
interruptedbyacontrollerfailover.
1 CreateaTestfolderontheserverandcopyatleast2GBofdataintoit.
2 ManuallyshutdownthefirstcontrollerwhilecopyingdatatoTestVol1toverifythatIO
isnotinterruptedbythefailoverevent.
a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,shutdownthefirstcontroller(thecontrollerthrough
whichthevolumeismapped).
c

166

Verifythatthecopyprocesscontinuesafterthecontrollerisshutdown.

Storage Center SC8000 Controller Deployment Guide

Verify Connectivity and Failover

d Afterthecopyfinishes,turnonthecontroller.
e Wait3minutesandverifythatthecontrollerhasfinishedstarting.
f

Rebalancetheports.

3 ManuallyshutdownthesecondcontrollerwhilecopyingdatatoTestVol2toverifythat
IOisnotinterruptedbythefailoverevent.
a CopytheTestfoldertotheTestVol2volume.
b Duringthecopyprocess,shutdownthesecondcontroller(thecontrollerthrough
whichthevolumeismapped).
c

Verifythatthecopyprocesscontinuesafterthecontrollerisshutdown.

d Afterthecopyfinishes,turnonthecontroller.
e Wait3minutesandverifythatthecontrollerhasfinishedstarting.
f

Rebalancetheports.

Test MPIO
IfthenetworkenvironmentandserversareconfiguredforMPIO,performteststomake
surethatfailedpathsdonotinterruptIO.
1 CreateaTestfolderontheserverandcopyatleast2GBofdataintoit.
2 MakesurethattheFCoriSCSIserverisconfiguredtouseloadbalancingMPIO(round
robin).
3 ManuallydisconnectapathwhilecopyingdatatoTestVol1toverifythatMPIOis
functioningcorrectly.
a CopytheTestfoldertotheTestVol1volume.
b Duringthecopyprocess,disconnectoneofthepathsandverifythatthecopy
processcontinues.
c

Reconnecttheport.

4 RepeatStep 3asnecessarytotestadditionalpaths.
5 (DualcontrollerStorageCenter)Restartthecontrollerthatcontainstheactivepath
whileIOisbeingtransferred.
6 IftheStorageCenterisnotinaproductionenvironment,restarttheswitchthatcontains
theactivepathwhileIOisbeingtransferred.

Clean up Test Volumes


Aftertestingiscomplete,deletethevolumesusedfortesting.

Dell Compellent

167

Chapter 6 Perform Post-Setup Tasks

Change Administrative Passwords


StorageCenterandtheiDRACshipwithdefaultadministrativecredentials.Asasecurity
measure,changethembeforeputtingtheStorageCenterintoproduction.

Change Storage Center Administrative Password


Changetheadministrativepasswordtosomethingotherthanthedefault.
1 FromtheStorageManagementmenu,selectUserChangeUserPassword.
2 SelectAdminandclickContinue.

3 EnteranewpasswordintheEnterPasswordandReenterPasswordfields.
4 ClickOK.

Change iDRAC Administrative Password


ChangetheiDRACadministrativepasswordtosomethingotherthanthedefault.
1 UseawebbrowsertonavigatetotheIPaddressoftheiDRACincontroller1.The
iDRACloginpageappears.
2 EntertheiDRACusername(root)andpassword(calvin)andclickSubmit.TheiDRAC
webinterfaceappears.
3 IntheleftpaneoftheiDRACwebinterface,clickUserAuthentication.
4 ClicktheLocalUserstabifnecessary.LocatetheAdministratoruserrowandclickthe
number(probably2)inthefirstcelloftherow.

168

Storage Center SC8000 Controller Deployment Guide

Change Administrative Passwords

5 ClickNext.
6 (Optional)EnteranewusernameintheUserNamefield.

7 EnteranewpasswordintheNewPasswordandConfirmNewPasswordfields.
8 ClickApply.

Dell Compellent

169

Chapter 6 Perform Post-Setup Tasks

Configure a Phone Home Proxy


Ifrequireshoststouseaproxyservertoreachtheinternet,configurePhoneHometouse
theproxyserverbeforesendingdatawithPhoneHomeorcheckingforStorageCenter
updates.
1 FromtheStorageManagementmenu,selectSystemPhoneHomeConfigure
PhoneHomeProxy.TheConfigurePhoneHomeProxywizardstarts.

2 SelectUsePhoneHomeProxyServerandenterthefollowing:

ProxyServerAddress:EntertheIPaddressoftheproxyserver.

Port:EntertheTCPportnumberoftheproxyserver.

ProxyUserName:Entertheusernamefortheproxyserver.

ProxyPassword/ConfirmPassword:Passwordfortheproxyserver.

3 ClickOK.

Phone Home
CompletesetupbysendingStorageCenterconfigurationinformationtoDellTechnical
SupportServiceswithPhoneHome.
PhoneHomesendsacopyofaStorageCenterconfigurationtoDellTechnicalSupport
ServicestoenablethemtosupportaStorageCenter.TheinitialconfigurationissenttoDell
TechnicalSupportServiceswhenStorageCenterisinstalled.

Prerequisites

170

TCPports22and443mustbeallowedoutboundtotheinternet.

Ifthenetworkrequireshoststouseaproxyservertoreachtheinternet,theStorage
CentermustbeconfiguredtouseaPhoneHomeproxy.

Storage Center SC8000 Controller Deployment Guide

Phone Home

Steps
1 FromtheStorageManagementmenu,selectSystemPhoneHomePhoneHome.
ThePhoneHomewizardstarts,listinganypreviousPhoneHomeevents.

2 ClickPhoneHomeNow.ThePhoneHomeInProgressdialogboxisdisplayed.

3 ClickOK.
4 WhentheStatecolumnlistsallitemswithSuccess,clickClose.

Dell Compellent

171

Chapter 6 Perform Post-Setup Tasks

Check for Storage Center Updates


AftercompletingtheStorageCentersetup,iftheStorageCenterSystemManagerdidnot
displayamessageofavailableupdates,manuallycheckforavailableStorageCenter
updates.
1 FromtheStorageManagementmenu,selectSystemUpdateUpdateStatus.
2 ClickCheckNow.AsStorageCenterchecksforupdates,statusappearsontheUpdate
Statuspage.
3 Ifanupdateisavailable,installtheupdatefollowingtheinstructionsintheStorage
CenterSystemUpgradeGuide.

Next Steps
Afterinstallationiscomplete,youmightwanttoperformsomebasictaskstoconfigure
StorageCenterforyourenvironment.Thesetasksareconfigurationdependentsosome
mightnotapplytoyoursite.
SeetheStorageCenterAdministratorsGuidefordetailedconfigurationinstructions,
includinghowto:

172

ManageUnmanagedDisks

AddStorageCenterusers;includingconfiguringLightweightDirectoryAccess
Protocol(LDAP)

Configurepasswordrulesforlocalusers

Createservers

ConfigureUserVolumeDefaults

AddStorageCentervolumes

Addaloginmessage

Storage Center SC8000 Controller Deployment Guide

Adding or Removing an Enclosure


ThischapterdescribeshowtoaddorremoveDellCompellentenclosuresfromaStorage
Center.

Contents
AddingSC280Enclosures ................................................... 174
AddingSC200/220Enclosures ................................................ 184
RemovingEnclosures ....................................................... 193

Dell Compellent

173

Appendix A Adding or Removing an Enclosure

Adding SC280 Enclosures


UsecautionwhenaddinganenclosuretoaliveStorageCentersystemtopreservethe
integrityoftheexistingdata.Thissectiondescribestwomethodsofaddingenclosures:

Addanenclosureinanewchain:byaddingenclosurestoavailableportsonthe
controllersIOcards.Thecurrentconfigurationisundisturbed.Creatinganewchainis
thesafestwaytoincreasestoragecapacity.Whenyouhavemultiplechains,youshould
haveatleasttwoIOcardsineachcontroller.

Addanenclosuretoanexistingchainbyremovingonesideofthechaincausingtraffic
toroutetotheremainingside.Connectthenewenclosureintothedisconnectedsideof
thechain.

Adding an SC280 Enclosure in a New Chain


Thismethodissafeandnonintrusivetotheexistingdisksandchains.Asecondchain
createscontrollerredundancyandsoIPCcrossovercablesarenotrequired.

Check Lead Controller


IdentifytheleadcontrollerbycheckingcontrollersummaryinformationinSystem
Manager.ThesecablinginstructionsassumethatControllerAistheleadcontroller.
1 IntheStorageCenterSystemManager,selecttheControllersnode.
2 Inthecontrollersummarypanenotewhichcontrollerisidentifiedastheleader.

Connect the Enclosure


1 Turnoneachenclosurebeingadded.Whentheenclosuresspinup,makesurethat
eachfrontpanelenclosureandpowerstatusLEDsshownormaloperation.
2 ConnecttheAside(Figure111onpage 176):
a ConnectControllerA:slot3,port2Enclosure2:left,portC.
b ConnectControllerB:slot3,port4Enclosure2:left,portB.
3 ConnecttheBside(Figure 112onpage 177):
a ConnectControllerA:slot3,port4Enclosure2:right,portB.
b ConnectControllerB:slot3,port2Enclosure2:right,portC.
4 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
5 Makesurethat:

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

6 IntheStorageManagerSystemTree,confirmthenumberofenclosures.
Iftherearenomanageddisksinthissystem,theSystemManagerdoesnotassignan
Indexnumber.Ifthesystemcontainsamanageddiskinanyenclosure,theSystem
Managerassignsanindexnumbertothenewenclosures.
Note: Enclosuresmustberunningthecurrentversionoffirmwarebefore
managingthedrivesinStorageCenterSystemManager.

174

Storage Center SC8000 Controller Deployment Guide

Adding SC280 Enclosures

7 Checkforavailableupdates:
a FromtheStorageManagementmenu,selectSystemUpdateUpdateStatus.
b ClickCheckNow.AsStorageCenterchecksforupdates,statusappearsinthe
UpdateStatuswizard.
c

Ifanupdateisavailable,downloadandinstalltheupdateasdescribedinStorage
CenterSoftwareUpdateGuide.

8 TheStorageCenterSystemManagerinformsyouthatyouhavenew,unassigneddisks.
FromtheStorageManagementmenu,selectDiskManageUnassignedDisksto
movethemtothemanageddiskfolderandaddthespacetothediskpool.
9 Redistributedataacrossalldrives,byselectingStorageManagement
Disk Rebalance RAID.

Dell Compellent

175

Appendix A Adding or Removing an Enclosure

Controller A
1 2 3 4

Controller B

1 2 3 4

Enclosure 1

Enclosure 2

Figure 111. Connecting a New SC280 SAS Chain (A Side)

176

Storage Center SC8000 Controller Deployment Guide

Adding SC280 Enclosures

Controller A
1 2 3 4

Controller B
1 2 3 4

Enclosure 1

Enclosure 2

Figure 112. Connecting a New SC280 SAS Chain (B Side)

Dell Compellent

177

Appendix A Adding or Removing an Enclosure

Adding to an Existing SC280 Enclosure Chain


Thefollowingexampleshowshowtoinsertanenclosureintoanexistingenclosurechain
byconnectingtheenclosuretoonesideoftheenclosurechainatatime.
Caution: Beforeaddinganenclosuretoanexistingchain,makesurethatyourdata
isbackedup.Formaximumprotection,addenclosuresduringaserviceoutage.

Check the Lead Controller


IdentifytheleadcontrollerbycheckingcontrollersummaryinformationinSystem
Manager.ThesecablinginstructionsassumethatControllerAistheleadcontroller.
1 IntheStorageCenterSystemManager,selecttheControllersnode.
2 Inthecontrollersummarypanenotewhichcontrollerisidentifiedastheleader.

Check Current Disk Count


CheckthecurrentnumberofdrivesaccessiblebytheStorageCentertouseasacomparison
afteranewenclosureisadded.
1 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigure LocalPorts.
2 MaximizetheConfigureLocalPortwizardsothatyoucanseetheTargetCount
column,andnotethenumberofdrivescurrentlyviewedbythecontrollers.This
numberincreaseswhennewenclosuresareadded.

Add an Enclosure to an Existing Chain Currently in Service


Whenaddingenclosurestoanexistingconfiguration,addenclosurestotheendofthe
chain.Disconnectthechainonesideatatimetomaintaindriveavailabilitywhileadding
anenclosure.

Connecting the Enclosure to the A Side


1 DisconnecttheAsidecablesfromthecontrollersasshowninFigure 113onpage 180.

ControllerA:slot3,port1

ControllerB:slot3,port3

IOcontinuesthroughtheBsidecables.
2 Turnontheenclosurebeingadded.Whenthedisksspinup,makesurethatthefront
panelenclosureandpowerstatusLEDsshownormaloperation.
3 MovethecablefromEnclosure1:left,portBEnclosure2:left,port C.
4 ConnectanewcablebetweenEnclosure1:left,portBEnclosure2:left,portAas
showninFigure 114onpage 181.
5 ConnecttheAsidecablestothecontrollersasshowninFigure 114onpage 181.

Enclosure2:left,portCControllerB:slot3,port3.

Enclosure1:left,portCControllerA,slot3port1.

6 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
7 Makesurethat:

178

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosure.
Storage Center SC8000 Controller Deployment Guide

Adding SC280 Enclosures

Connecting the Enclosure to the B Side


1 DisconnecttheBsidecablesfromthecontrollersasshowninFigure 115onpage 182

ControllerA:slot3,port3

ControllerB:slot3,port1

IOcontinuesthroughtheAsidecables.
2 MovethecablefromEnclosure1:right,portBEnclosure2:right,port C.
3 ConnectanewcablebetweenEnclosure1:right,portAEnclosure2:right,portBas
showninFigure116onpage 183.
4 ReconnecttheBsidecablestothecontrollersasshowninFigure116onpage 183.

Enclosure1:right,portCControllerB:slot3,port1.

Enclosure2:right,portCControllerA:slot3,port3.

Manage the New Disks


Aftertheenclosureisconnected,makesurethatitisrunningthemostrecentversionof
software.
Note: Enclosuresmustberunningthecurrentversionoffirmwarebeforemanaging
thedrivesinStorageCenterSystemManager.
1 Checkforavailableupdates:
a FromtheStorageManagementmenu,selectSystemUpdateUpdateStatus.
b ClickCheckNow.AsStorageCenterchecksforupdates,statusappearsinthe
UpdateStatuswizard.
c

Ifanupdateisavailable,downloadandinstalltheupdateasdescribedinStorage
CenterSoftwareUpdateGuide.

2 TheStorageCenterSystemManagerinformsyouthatyouhavenew,unassigneddisks.
FromtheStorageManagementmenu,selectDiskManageUnassignedDisksto
movethemtothemanageddiskfolderandaddthespacetothediskpool.Formore
information,seetheStorageCenterSystemManagerAdministratorsGuide.
3 ViewthelistofenclosuresinSystemManagerandverifythatthenewenclosuresand
disksappearintheSystemTree.
4 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.Makesurethat:

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

5 Toredistributedataacrossalldrives,fromtheStorageManagementmenu,select
DiskRebalance RAID.

Dell Compellent

179

Appendix A Adding or Removing an Enclosure

Controller A
1 2 3 4

Disconnect
Controllers,
A-side
Controller B
1 2 3 4

Move Cable
to Enclosure
2, port C

Enclosure 1

Enclosure 2

Figure 113. Disconnect Controllers (A side)

180

Storage Center SC8000 Controller Deployment Guide

Adding SC280 Enclosures

Controller A
1 2 3 4

Controller B
1 2 3 4

Enclosure 1

Add cable

Enclosure 2

Figure 114. Add Cable and Reconnect Controllers (A Side)

Dell Compellent

181

Appendix A Adding or Removing an Enclosure

Controller A
1 2 3 4

Controller B
1 2 3 4

Disconnect
Controllers,
B-side
Move Cable to
Enclosure 2,
port C

Enclosure 1

Enclosure 2

Figure 115. Disconnect Controllers (B Side)

182

Storage Center SC8000 Controller Deployment Guide

Adding SC280 Enclosures

Controller A
1 2 3 4

Controller B
1 2 3 4

Enclosure 1

Add cable

Enclosure 2

Figure 116. Add Cable and Reconnect Controllers (B Side)

Dell Compellent

183

Appendix A Adding or Removing an Enclosure

Adding SC200/220 Enclosures


UsecautionwhenaddinganenclosuretoaliveStorageCentersystemtopreservethe
integrityoftheexistingdata.Thissectiondescribestwomethodsofaddingenclosures:

CreateanewchainbyaddingenclosurestoavailableportsonthecontrollersIOcards.
Thecurrentconfigurationisundisturbed.Creatinganewchainisthesafestwayto
increasestoragecapacity.Whenyouhavemultiplechains,youshouldhaveatleasttwo
IOcardsineachcontroller.

Addanenclosuretoanexistingchainbyfailingovertoonesideofthechainandthen
connectingintotheothersideofthechain.

Creating a New Chain of SC200/220 Enclosures


Thismethodissafeandnonintrusivetotheexistingdisksandchains.Figure117on
page 185showsanexampleofaddinganewchainusingthefollowingsteps.
1 Ifthereismorethanoneenclosureinthenewchain,cabletheenclosurestogetherfirst.
Donotconnectthechaintothecontrolleryet.Connecttheenclosures:
a NewEnclosure(3):top,portBNextEnclosure(4):top,port A.
b NewEnclosure(3):bottomportBNextEnclosure(4):bottom,portA.
2 Turnoneachoftheenclosuresbeingadded.Whentheenclosuresspinup,makesure
thatthefrontpanelenclosureandpowerstatusLEDsshownormaloperation.
3 ConnecttheController:slot6,port2Enclosure3:top,portA.
4 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
5 Makesurethat:

Slotandslotport(inthiscase,slot6,port2)areUpandthePurposeissettoback
end.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

6 IntheStorageManagerSystemTree,confirmthenumberofenclosures.
7 ConnectlastEnclosure(4):bottom,portBController:slot6,port4.
8 Verifythatthelastenclosurehasbeenaddedasdescribedinsteps4through6.
9 Iftherearenomanageddisksinthissystem,theSystemManagerdoesnotassignan
Indexnumber.Ifthesystemcontainsamanageddiskinanyenclosure,theSystem
Managerassignsanindexnumbertothenewenclosures.
10 TheStorageCenterSystemManagerinformsyouthatyouhavenew,unassigneddisks.
fromtheStorageManagementmenu,selectDiskManageUnassignedDisksto
movethemtothemanageddiskfolderandaddthespacetothediskpool.Formore
information,seetheStorageCenterSystemManagerAdministratorsGuide.
11 Toredistributedataacrossalldrives,fromtheStorageManagementmenu,select
DiskRebalance RAID.

184

Storage Center SC8000 Controller Deployment Guide

Adding SC200/220 Enclosures

Controller

Enclosure 1

Enclosure 2

Enclosure 3

Two new enclosures added


Enclosure 4

Figure 117. Connecting a New SC200/220 SAS Chain

Dell Compellent

185

Appendix A Adding or Removing an Enclosure

Adding to an Existing SAS Enclosure Chain


Thefollowingexampleshowshowtoinsertanenclosureintoanexistingenclosurechain
byconnectingtheenclosuretoonesideoftheenclosurechainatatime.Duringthis
process,onesideoftheenclosurechainisdisconnected,andtheStorageCenterfailsover
tothesidethatremainsconnected.
Caution: Beforeaddinganenclosuretoanexistingchain,makesurethatyourdata
isbackedup.Formaximumprotection,addenclosuresduringaserviceoutage.

Check the Lead Controller


IdentifytheleadcontrollerbycheckingcontrollersummaryinformationinSystem
Manager.ThesecablinginstructionsassumethatControllerAistheleadcontroller.
1 IntheStorageCenterSystemManager,selecttheControllersnode.
2 Inthecontrollersummarypanenotewhichcontrollerisidentifiedastheleader.

Check Current Disk Count


CheckthecurrentnumberofdrivesaccessiblebytheStorageCentertouseasacomparison
afteranewenclosureisadded.
1 Fromaworkstationconnectedtothenetwork,opentheStorageCenterSystem
Manager.
2 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigure LocalPorts.
3 MaximizetheConfigureLocalPortwizardsothatyoucanseetheTargetCount
column,andnotethenumberofdrivescurrentlyviewedbythecontrollers.This
numberincreaseswhennewenclosuresareadded.Whenaddingenclosurestoan
existingconfiguration,addenclosurestotheendofthechain.

Add an Enclosure to an Existing Chain Currently in Service


Disconnectthechainonesideatatimetomaintaindriveavailabilitywhileaddingan
enclosure.
1 DisconnecttheAsidecablesfromthecontrollersasshowninFigure 118onpage 187:

ControllerA,slot6port1

ControllerB,slot6port3

IOcontinuesthroughtheBsidecables.
2 Turnoneachoftheenclosuresbeingadded.Whentheenclosuresspinup,makesure
thatthefrontpanelenclosureandpowerstatusLEDsshownormaloperation.
3 MovethecablefromEnclosure2:top,portBEnclosure4:top,port B.
4 UsenewcablestoconnectthenewenclosurestotheAsidecabling(Figure 118on
page 187):

Enclosure2:top,portBEnclosure3:top,portA.

Enclosure3:top,portBEnclosure4,top,portA.

Enclosures3and4arenowpartoftheAsidechainandcanbeconnectedtoControllers
AandB.

186

Storage Center SC8000 Controller Deployment Guide

Adding SC200/220 Enclosures

Controller A
Disconnect A side

Controller B

Enclosure 1
Move Cable from
Enclosure 2

Enclosure 2

Add cable
Enclosure 3
Connect
Enclosures
(A side)
Add cable
New Enclosures
Enclosure 4

Figure 118. Connect SC200/220 Enclosures to A side


5 ReconnecttheAsideControllercables:
a Enclosure4:top,portBControllerB:slot6,port3.
b Enclosure1:top,portAControllerA,slot6,port1.

Dell Compellent

187

Appendix A Adding or Removing an Enclosure

Controller A

Controller B

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 119. Reconnect SC200/220 A-side Cables to Controllers


6 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
7 Makesurethat:

188

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

Storage Center SC8000 Controller Deployment Guide

Adding SC200/220 Enclosures

8 DisconnecttheBsidecablesfromthecontrollersasshowninFigure 120:

ControllerA:slot6port3.

ControllerB,slot6port1.

IOcontinuesthroughtheAsidecables.
9 MovethecablefromEnclosure2:bottom,portBEnclosure4:bottom,port B.
10 Usenewcablestoconnectthenewenclosurestotheexistingenclosures(Bside):

Enclosure2:bottom,portBEnclosure3:bottom,portA.

Enclosure3:bottomportBtoEnclosure4:bottomportA.

Enclosures3and4arenowpartoftheBsidechainandcanbeconnectedtoControllers
AandB.
Controller A

Disconnect B side
Controller B

Enclosure 1

Enclosure 2
Move Cable from
Enclosure 2

Add cable
Enclosure 3
Connect
Enclosures
(B side)
Add cable
Enclosure 4

Figure 120. Connect SC200/220 Enclosures to B Side

Dell Compellent

189

Appendix A Adding or Removing an Enclosure

11 ConnectEnclosure4:bottom,portBControllerA:slot6,port3.
12 ReconnectEnclosure1:bottom,portAControllerB:slot6,port1.
Controller A

Controller B

Enclosure 1

Enclosure 2

Enclosure 3

Enclosure 4

Figure 121. Reconnect SC200/220 B-side Cables to Controllers


13 TheStorageCenterSystemManagerinformsyouthatyouhavenew,unassigneddisks.
FromtheStorageManagementmenu,selectDiskManageUnassignedDisksto
movethemtothemanageddiskfolderandaddthespacetothediskpool.Formore
information,seetheStorageCenterSystemManagerAdministratorsGuide.
14 IntheStorageManagerSystemTree,viewthelistofenclosures.TheSystemManager
assignsanindexnumbertoallmanageddrives.
15 Toredistributedataacrossalldrives,fromtheStorageManagementmenu,select
DiskRebalance RAID.

190

Storage Center SC8000 Controller Deployment Guide

Adding SC200/220 Enclosures

Adding a Second SAS Enclosure, Second Chain


Inadualcontroller,singleSASenclosureconfiguration,controllerredundancyiscreated
usingcrossovercables(IPC)fromcontrollerports2tocontrollerports4.Asecondchain
performsthesameredundancyastheIPCcrossovercables.

Add an Enclosure
Addanewenclosurewhilemaintainingredundancy.
1 Powerontheenclosuresbeingadded.Whentheenclosuresspinup,makesurethatthe
frontpanelenclosureandpowerstatusLEDsshownormaloperation.
2 RemovethetwoIPCcablesfromtheControllers,ports2and4.
3 Connect:ControllerA,port2new Enclosure 3:top,portA.
4 ConnectEnclosure3:top,portBControllerB,port4.
5 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
6 Makesurethat:

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.
Controller A

Controller B

Enclosure 1

Enclosure 2

Enclosure 3

Figure 122. Adding an SC200/220 SAS Enclosure, Step 1

Dell Compellent

191

Appendix A Adding or Removing an Enclosure

7 ConnectControllerA:port4newEnclosure3:bottom,portB.
8 ConnectEnclosure3:bottom,portAControllerB:port2.
9 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
10 Makesurethat:

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

Controller A

Controller B

Enclosure 1

Enclosure 2

Enclosure 2

Figure 123. Adding an SC200/220 SAS Enclosure, B side

192

Storage Center SC8000 Controller Deployment Guide

Removing Enclosures

Removing Enclosures
ThefollowingproceduredescribeshowtouseStorageCenterSystemManagertomove
dataoffthedisksintheenclosuretoberemoved.Formoredetailedinstructions,seethe
StorageCenterSystemManagerAdministratorsGuide.
Caution: Beforeyouremoveanenclosure,makesurethatyourdataisbackedup
andthatalldiskstoberemovedareemptyofdata.

Release Disks
Releasediskstoremovethemfromthepoolinpreparationofremovingtheenclosure.
1 IntheStorageCentertree,expandtheDisksnodetoviewthedisksintheenclosure.
2 Selectallthedisksintheenclosureyouareremoving.
3 Fromtheshortcutmenu,selectReleaseDisk.TheReleaseDiskwizardstarts.
4 NotethewarningandclickYestocontinue.Thediskisimmediatelyreleasedanda
dialogboxopensaskingifyouwishtorebalanceRAIDdevicesnow,later,orskip
balancing.
5 ClickYes.Waitfortherebalanceoperationtofinish.
Enclosureswithalldrivesintheunassigneddiskfolderarenowsafetoremove.

Remove an SC280 Enclosure


TheseinstructionsdescribehowtoremoveanenclosurefromanSC280enclosurechain.If
theconfigurationhastwoenclosurechains,youdonotneedtotakeasystemoutage;
however,thecontrollermustbeabletoseealldrivesthroughonechainwhiletheotherside
isdown.
Caution: TodisconnecttheAsidecablingwithoutasystemoutage,makesurethat
youfirstdisconnecttheAsidecablefromthecontroller.Disconnectinganyother
cablefirstdisruptsIOtotheenclosure,resultinginasystemoutage.

Disconnect the A-side Chain


DisconnecttheenclosuretoberemovedfromtheAsidechain.
1 DisconnecttheAsidecablefromControllerB:slot3,port3.TheBsidecontinuesto
carryIOwhiletheAsideisdisconnected(seeFigure 124onpage 194).
2 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
3 Makesurethat:

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

4 Removethecablebetween:Enclosure1:left,portBEnclosure2:left,portA(see
Figure 124onpage 194).
5 MovethecablefromEnclosure2:left,portCEnclosure1:left,port A(seeFigure 125
onpage 195).
6 ReconnectthetopcabletoControllerB:slot3,port3(seeFigure 125onpage 195).

Dell Compellent

193

Appendix A Adding or Removing an Enclosure

Controller A

Controller B

1 2 3 4

1 2 3 4

Disconnect A side
Enclosure 1

Remove the A-side


cable between
enclosures
Enclosure 2

Figure 124. Disconnecting the SC280 Enclosure from the A side

194

Storage Center SC8000 Controller Deployment Guide

Removing Enclosures

Controller A

Controller B

Reconnect A side,
after moving the
cable below

1 2 3 4

1 2 3 4

Enclosure 1
A

Move the A-side cable


to remaining enclosure

Enclosure 2

Figure 125. Reconnecting the A-Side Cable

Dell Compellent

195

Appendix A Adding or Removing an Enclosure

Caution: TodisconnecttheBsidecablingwithoutasystemoutage,makesurethat
youfirstdisconnecttheBsidecablefromthecontroller.Disconnectinganyother
cablefirstdisruptsIOtotheenclosure,resultinginasystemoutage.

Disconnect the B-side Chain


DisconnecttheenclosuretoberemovedfromtheBsidechain.
1 DisconnecttheBsidecablefromControllerA:slot3,port3.TheAsidecontinuesto
carryIOwhiletheB sideisdisconnected(seeFigure 126onpage 197).
2 IntheStorageCenterSystemManager,selectStorageManagementSystem
SetupConfigureLocalPorts.
3 Makesurethat:

SlotandslotportsareUpandthePurposeissettobackend.

TargetCountequalsthenumberofaddeddrives,demonstratingthatthecontroller
recognizesthenewenclosures.

4 RemovethecablebetweenEnclosure1:right,portAEnclosure 2:right,portB(see
Figure 126onpage 197).
5 MovethecablefromEnclosure2:right,portCEnclosure1:right,port B(see
Figure 126onpage 197).
6 ReconnecttheBsidecabletoControllerA:slot3,port3(seeFigure 127onpage 198).
7 Theenclosureisnowdisconnectedandcanberemoved.

196

Storage Center SC8000 Controller Deployment Guide

Removing Enclosures

Disconnect
B side
Controller A
1 2 3 4

Controller B

1 2 3 4

Enclosure 1

Remove the B-side cable


between enclosures

Move to
Enclosure 1,
right, port B

Enclosure 2

Figure 126. Disconnecting the SC280 Enclosure from the B-side Chain

Dell Compellent

197

Appendix A Adding or Removing an Enclosure

Reconnect B side

Controller A
1 2 3 4

Controller B

1 2 3 4

Enclosure 1

Figure 127. Reconnecting the B-Side Cable

198

Storage Center SC8000 Controller Deployment Guide

Removing Enclosures

Remove an SC200/SC220 Enclosure


TheseinstructionsdescribehowtoremovethetopenclosurefromaSC200/SC220
enclosurechain.Iftheconfigurationhastwoenclosurechains,youdonotneedtotakea
systemoutage;however,thecontrollermustbeabletoseealldrivesthroughonechain
whiletheothersideisdown.
Caution: TodisconnecttheAsidecablingwithoutasystemoutage,makesurethat
youfirstdisconnecttheAsidecablefromthecontroller.Disconnectinganyother
cablefirstdisruptsIOtotheenclosure,resultinginasystemoutage.

Disconnect the A-side Chain


DisconnecttheenclosuretoberemovedfromtheAsidechain.
1 DisconnecttheAsidecablefromControllerA:slot6,port1.TheBsidecontinuesto
carryIOwhiletheAsideisdisconnected(seeFigure 128onpage 200).
2 IntheConfigureLocalPortswizard,makesurethattheBsideportsonbothcontrollers
areUpandtheTargetCountrecognizesthedrivesthroughtheBside.
3 Removethecablebetween:Enclosure1:top,portBEnclosure2:top,portA(see
Figure 128onpage 200).
4 MovethecablefromEnclosure1:top,portAEnclosure2:top,port A(seeFigure 129
onpage 201).
5 ReconnectthetopcabletoControllerA:slot6,port1(seeFigure 130onpage 203).

Dell Compellent

199

Appendix A Adding or Removing an Enclosure

Controller A

Disconnect A side

Controller B

Enclosure 1

Remove the A-side cable


between enclosures
Enclosure 2

Enclosure 3

Enclosure 4

Figure 128. Disconnecting the SC200/220 Enclosure from the A side

200

Storage Center SC8000 Controller Deployment Guide

Removing Enclosures

Controller A

Reconnect A side, after


moving the cable below

Controller B

Enclosure 1
Move the A-side cable
to next enclosure

Enclosure 2

Enclosure 3

Enclosure 4

Figure 129. Reconnecting the SC200/220 A side

Dell Compellent

201

Appendix A Adding or Removing an Enclosure

Caution: TodisconnecttheBsidecablingwithoutasystemoutage,makesurethat
youfirstdisconnecttheBsidecablefromthecontroller.Disconnectinganyother
cablefirstdisruptsIOtotheenclosure,resultinginasystemoutage.

Disconnect the B-side Chain


DisconnecttheenclosuretoberemovedfromtheBsidechain.
1 DisconnecttheBsidecablefromControllerB:slot5,port1.TheAsidecontinuesto
carryIOwhiletheB sideisdisconnected(seeFigure 130onpage 203).
2 IntheConfigureLocalPortswizard,makesurethattheAsideportsonbothcontrollers
areUpandtheTargetCountrecognizesthedrivesthroughtheAside.
3 RemovethecablebetweenEnclosure1:bottom,portBEnclosure 2:bottom,portA
(seeFigure 130onpage 203).
4 ReconnecttheBsidecabletoControllerB:slot5,port1(seeFigure 131onpage 204).
5 Thetopenclosureisnowdisconnectedandcanberemoved.

202

Storage Center SC8000 Controller Deployment Guide

Removing Enclosures

Controller A
Disconnect
B side

Controller B

Enclosure 1

Remove the B-side


cable between
enclosures
Enclosure 2
Move to Enclosure
2, bottom, port A

Enclosure 3

Enclosure 4

Figure 130. Disconnecting the SC200/220 Enclosure from the B-side Chain

Dell Compellent

203

Appendix A Adding or Removing an Enclosure

Reconnect B side

Controller A

Controller B

Figure 131. Top SC200/220 Enclosure Disconnected

204

Storage Center SC8000 Controller Deployment Guide

Troubleshooting
Thisappendixcontainstroubleshootingstepsforcommonproblems.

Contents
TroubleshootingtheSerialConnection ........................................ 205
TroubleshootingEnclosures .................................................. 205
TroubleshootingLicenses .................................................... 206
TroubleshootingUpdates .................................................... 206

Troubleshooting the Serial Connection


Issue

Possible Reason

Solution

Unabletoconnecttoa
controllerwithaserial
connection

Communicationproblems.

Reseatorreplacecables.
Verifythetelnetsettings.

Troubleshooting Enclosures
Issue

Possible Reason

NoDisksFoundbyStartup
Wizard:

Needtoupdatesoftwareand/or 1 ClickQuit.
firmwaretouseattached
2 CheckforStorageCenterUpdatesonpage 172.
enclosure.
3 CompletetheStartupWizardonpage 129.

Nodiskscouldbefound
attachedtothisDell
CompellentStorageCenter.
Enclosurefirmwareupdate
fails

Cablingisnotredundant.

Solution

1 Checkthebackendcablingandensurethat
redundantconnectionsareused.
SeeSASRedundancyonpage 55formore
information.

ExpectedDisksand/or
EnclosuresareMissing

Dell Compellent

Needtoupdatesoftwareand/or 1 Checkthebackendcablingandenclosures
firmwaretouseattached
powerstate.
enclosureand/ordrives.
2 CheckforStorageCenterUpdatesonpage 172.

205

Appendix B Troubleshooting

Troubleshooting Licenses
Issue

Possible Reason

Solution

Error:Thelicensefileisnot
valid(couldbeoldlicense
file).ContactDellTechnical
SupportServicesforanew
licensefile.

Canhappenwithadual
controllerStorageCenterif
thereisanattempttoapplythe
licensefilebeforethecontrollers
arejoinedandthelicensefileis
appliedtothecontrollerwith
thewrongserialnumber.

MakesurethatallthestepsinChapter 5:Setupthe
StorageCenterSoftware,onpage 119arefollowed
inorderandtryagain.
MakesuretoconnecttotheIPaddressofthe
controllerwiththelowerserialnumber.
Makesuretheserialnumberinthenameofthe
licensefilematchesthecontroller.

Troubleshooting Updates
Issue

Possible Reason

Solution

CannotcompleteStartup
Yournetworkmightemploya 1 EstablishaserialconnectiontotheStorage
Wizardandcannotcheckfor proxyserver,ConfigurePhone
Center.
updates
HomeProxyServerUsingthe 2 Runthefollowingcommands:
CommandLineInterface(CLI).
mc values set UsePhHomeProxy true
mc values set PhHomeProxyString
[proxy server IP address]
mc values set PhHomeProxyUserName
[proxy server user name]
mc values set PhPomeProxyPassword
[proxy server password]
3 CheckforStorageCenterUpdatesonpage 172.
4 CompletetheStartupWizardonpage 129.

206

Storage Center SC8000 Controller Deployment Guide

680-087-001 D