PTT PUBLIC COMPANY LIMITED

ONSHORE COMPRESSOR STATION 4 PROJECT

DATA SHEET
FOR
NON-SLAM CHECK VALVE
DS-50-0804.02-6000-004

D2

11 Jun 08

Issued for ITB

Sahaporn

D1

2 Apr 08

Issued for ITB

Sahaporn

REV.

DATE

DESCRIPTION

Contract No.
Contractor

PTT Project No.


0804.02

PREPARED REVIEWED
BY PTT
BY PTT

CHECKED APPROVED
BY PTT
BY PTT

Order No.
Client Consultant
Engineer

DATA SHEET
FOR
NON-SLAM CHECK VALVE

PTT PUBLIC COMPANY


LIMITED
ONSHORE COMPRESSOR
STATION 4 PROJECT
CLIENT:
MANUFACTURER:
SERVICE OF UNIT:
PLANT LOCATION:
1 VALVE TAG NUMBER
2 LINE No.

3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

MAKE
MODEL NUMBER
CONNECTIONS
INLET/OUTLET
FLANGE STANDARD
OPERATING POSITION
INSTALLATION
LOCATION
FLUID DETAILS AT VALVE INLET
FLUID
PHASE
OPERATING DENSITY
MOLECULAR WEIGHT
COMPRESSIBILITY FACTOR
OPERATING CONDITIONS
OPERATING TEMPERATURE
OPERATING PRESSURE
HIGH CYCLING
NACE COMPLINANCE
ACTUAL FLOW RATES
MAX / NOR / MIN
MECHANICAL DESIGN
FIRE SAFE DESIGN
DESIGN TEMPERATURE
DESIGN PRESSURE
TEST PRESSURE
DESIGN CODE
ASME RATING
DESIGN Cv

kg/m3
kg/kmol

o
C (F)
psig (barg)

ACFM

C (F)
barg (psig)

- BODY
- PIN
- SEATS

48
- BOLTING
49
- SEALS
50
- DISC
51
- Spring
52 ESTIMATED WEIGHT
53
54 PROJECT SPECIFICATION
VALVE SPECIFICATION
ALLOWABLE PRESSURE LOSS

PROJECT:
SUPPLIER:

NATURAL GAS (SOUR)


RAYONG, THAILAND

LINE SIZE
PID No.
QUANTITY
VALVE TYPE

STYLE
43
44 OPERATOR
45 MATERIALS
46
47

55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80

PTT PUBLIC COMPANY LIMITED

kgs

PROJECT NO.
EQUIPMENT NAME
DATA SHEET NO.
PAGE
REV

0804.02
Non-Slam Check Valve
DS-50-0804.02-6000-004
2 OF 2
D2

Onshore Compressor Station 4 (OCS 4)

CV-102A/B/C
6000-G-019-20"-D72R-P-90
6000-G-027-20"-D72R-P-90
6000-G-036-20"-D72R-P-90
20"
15-3-0804.02-6000-006/008/010
3
Non-Slam Check

P.O. No.
CV-101A/B/C
6000-G-016-24"-D72R-V
6000-G-024-24"-D72R-V
6000-G-033-24"-D72R-V
24"
15-3-0804.02-6000-006/008/010
3
Non-Slam Check

CV-103A/B/C
6000-G-023-20"-D72R-V
6000-G-031-20"-D72R-V
6000-G-040-20"-D72R-V
20"
15-3-0804.02-6000-007/009/011
3
Non-Slam Check

*
*

*
*

*
*

20" 900# RTJ / 20" 900# RTJ


ASME B16.5

24" 900# RTJ / 24" 900# RTJ


ASME B16.5

20" 900# RTJ / 20" 900# RTJ


ASME B16.5

Horizontal
Compressor Discharge

Horizontal
Compressor Suction

Horizontal
Gas Cooler Discharge

Natural Gas (Note 4)


Gas/Vapor
75.62
23.80
0.916

Natural Gas (Note 4)


Gas/Vapor
38.07
23.80
0.895

Natural Gas (Note 4)


Gas/Vapor
96.19
23.80
0.825

115 (239)
1350(93)
No
Yes, NACE MR0175

25 (77)
500 (34.5)

50 (122)
1342.7 (92.58)

Yes, NACE MR0175

Yes, NACE MR0175

4,702.40

9,340.80

3,512.30

yes
140 (284)
98 (1,421)
API 6D
API 6D
ASME B16.5 CLASS 900
*

yes
140 (284)
98 (1,421)
API 6D
API 6D
ASME B16.5 CLASS 900
*

yes
140 (284)
98 (1,421)
API 6D
API 6D
ASME B16.5 CLASS 900
*

Manufacturer's Standard

Manufacturer's Standard

Manufacturer's Standard

A350 LF2
13% Cr SS
Hard Faced 13% Cr SS, Renewable
A193/B7M with A194/2HM nuts,
Fluor-Polymer Coated
Manufacturer's Standard
13% Cr SS
Inconel
*

A350 LF2
13% Cr SS
Hard Faced 13% Cr SS, Renewable
A193/B7M with A194/2HM nuts,
Fluor-Polymer Coated
Manufacturer's Standard
13% Cr SS
Inconel
*

A350 LF2
13% Cr SS
Hard Faced 13% Cr SS, Renewable
A193/B7M with A194/2HM nuts,
Fluor-Polymer Coated
Manufacturer's Standard
13% Cr SS
Inconel
*

SPC-50-0804.02-6000-011 CLASS
D72R
<0.1bar (*)

SPC-50-0804.02-6000-011 CLASS
D72R
<0.1bar (*)

NOTES:
1) * To be confirm and specify by contractor.
2) Check valve to be painted in accordance with SPC-0804.02-92.06
3) Check valve shall test per API6D at maximum flage rating design pressure
4) Gas contains traces of mercury = 50 g/Nm3. No copper, aluminium or copper/aluminium alloys in contact with gas.
5) Positive Material Identification shall be provided according to PTT Specification SPC-0804.02-92.08

SPC-50-0804.02-6000-011 CLASS
D72R
<0.1bar (*)