Sei sulla pagina 1di 2

STR100-STR107

0FL-4068-001

Wall Modules

MOUNTING, CABLES

User's Manual

CONNECTING
Connecting STR100 to a
TAC Generic Controller
STR 100

TAC Controller

M 11
Therm 12

M
B/U

Connecting STR101-107 to a
TAC Xenta 100 Controller
STR 101 -107

To avoid base-plate deformation, be careful when


tightening the mounting screws. Note that the
enclosed screws are mainly intended for the US
and Australian markets.

REMOVING THE CORE


The core panel is attached to the base-plate using two
hinges. Remove the core panel by pushing the bottom of
the core panel upwards, then unhinging the core panel
from the base-plate.

OP
G
C2
C1

24
23
22
21

M
Therm
Pot/Pot+R
Switch
Mx
LED

11
12
13
14
15
16

TAC Xenta 100 Family

OP
G
C2
C1

STR102, 104, 106, 107


STR104, 106, 107

M
B1
R1
X1
M
D1

Connecting STR101-107 to a
TAC Xenta 200/300/400 Controller
STR 101 -107

TAC Xenta 200/300/400 Family

OP
G
C2
C1

24
23
22
21

G0
G
C2
C1

M
Therm
Pot/Pot+R
Switch
Mx
LED

11
12
13
14
15
16

M
B1/U1
B2/U2
X1 (B3/U3) *
M
K1
KC1

STR102, 104, 106, 107


STR103, 104 (106, 107) *

*STR103, 104: Connect to digital input, X or U.


STR106, 107: Connect to thermistor input (1.8k) B or U.
Wiring
Cable type ............................. Twisted pair, unshielded
Cable size ................................ Min 0.7 mm2 (19 AWG)
Distance ............................................ Max 30 m (100 Ft)
0FL-4068-001, 10 Nov 2003

English

1 (2)

ATTACHING/REMOVING THE FRONT


The front is attached to the
base-plate using four
clamps, two at the top of the
front panel and two at the
bottom.

STR100

When removing the frontpanel use a screwdriver (or


similar) and push gently to
unhook the clamps at the
top or bottom of the front
panel.

Mode indicator
On/Off

STR101

Mode indicator
On/Off

JUMPER POSITION

Temperature
Setting

STR102

Rear view
of core.

Mode indicator
On/Off
Temperature
Setting
(Not available
on STR103)

Jumper

STR103/STR104

Bypass button

Mode indicator
On/Off
Temperature
Setting

TAC Xenta 200, 300


and 400 series
Position of jumper
when a TAC Xenta
200, 300 or 400
controller is used.

STR106/STR107

Bypass button
Fan speed
control

TAC Xenta 100 series


Position of toggle
when a TAC Xenta 100
controller is used.

STR106/107
24 23 22 21

11 12 13

14 15 16

TEMPERATURE WHEEL

RJ-10

470

1874

10k

The temperature is controlled using the temperature setting


wheel. The adjustment range on the temperature wheel
may be set to the following limits:
+/-1 C (+/-1.8F)
+/-2 C (+/-3.6F)
+/-3 C (+/-5.4F)
+/-4 C (+/-7.2F)
+/-5 C (+/-9F)
The adjust spacing is done using plastic keys on the back
of the core.

2670
0
P

3870

P+R

I
3040
II

TAC Xenta OP

4600
III

STR106 only
Trademarks and registered trademarks are the property of their respective owners.
TAC Vista, TAC Menta, TAC Xenta and Talking Buildings are registered trademarks of TAC AB. LonMark and LonWork are registered trademarks of the Echelon Corporation.
Windows is a registered trademark of Microsoft.

www.tac.com