Sei sulla pagina 1di 3

Corporate Headquarters:

35 FRJ Drive
Longview, TX. 75602
Ph: (903) 753-1412
Fax: (903) 753-6112

Date: 8/4/2015
HTT Job No.: None
Site: Longview, Tx
PO/AFE/WO Number: None
Code Section/Criteria:
Client Info
Client Spec.:
Info
Revision No.: 15
Cal. Record No.: 10/20/14BB

Customer: Joy Global


Referenced Code: Client info
NDT Proc. No.: HTT-UT-001
Item Identification:

Page 1 of 3

Item #4272712 Part #68AXDX

ITEM: Other

Detail H gap

Surface Condition:
Coated
Wire Wheeled
Other: uneven surface
Weld Coverage:
N/A
General/Calibration
Exam Type: Strait and Shear Angle Beam
Linearity Block Type: IIW
Instrument Manufacturer:
Olympus
SN: 1325-10
Sensitivity Block Type:
N/A
Instrument Model:
OmniScan SX
Reflector Type:
Backwall
Instrument Serial Number:
OMNI-100956
Non-Weld:
Distance Amplitude
Instrument Type:
Digital
Block Dimensions:
12" X 1.5" X 4"
Scan Type:
Manual Scan
Block Temperature:
70 F
Horizontal Linearity Cal. Date:
08/27/2014
Surface Used: ID
Vertical Linearity Cal. Date:
08/27/2014
SN/ID 1
80%
SN/ID 2
30%
SN/ID 3
10%
Amplitude Linearity Cal. Date:
08/27/2014
Part Temperature:
70 F Mat'l Type: Carbon Steel
Clad? NO
Couplant Manu/Type:
Ultrajel II
Special Equip: None
Strait Beam Resolution Check Date:
8/4/2015
Probe Cal Info.
Probe 1
Probe 2
Probe 3
Probe 4
Probe 5
Probe 6
Probe 7
Manufacturer:
Britek
Serial No.:
B11571
Size:
0.500''
Frequency:
2.25MHz
Wave Type:
Longitudinal
Angle:
0.0
Pulser:
Single
Cable Type/Length:
6.00 ft.
Reference dB:
34.0dB
Scan dB:
40.0dB
Reject:
0
Range:
5.0''
Damping:
50
Cal. Velocity:
0.2329s
Cal Check Times

9:00

11:00
Results

Total items Examined:

Total items Accepted:

1 Total Items Rejected:


0 Total items inaccessible:
0
Comments
Performed a manual zero degree inspection to determine the gap between parts in relation to components in Detail H on Drawing
4272712. All four sides of the attachment were checked for gap, there were two separate attachments on this part. For purposes of this
report the A attachment is located on the side where the Part # was located.

Angle Beam Tech

Level

Signature

Date

Strait Beam Tech

Level

Signature

Date

Brandon Suttle
Assistant
Consumables
Couplant
1 Gal.

III

8/4/2015

Brandon Suttle

Assistant

Assistant

Equip./Other:

Round trip Mileage

Total Personnel Hours

Days of Per Diem

Manual Sear-Wave

20

12

Attach the following as applicable: Summary reports, Indication reports, sketches, other
Customer Acceptance:
Form UT-FD-001 Rev. 7 10/21/14

Total pages attached: 1

Corporate Headquarters:
35 FRJ Drive
Longview, TX. 75602
Ph: (903) 753-1412
Fax: (903) 753-6112

Side A
Ite

0.04"
0.033"

0.05"

0.10"

Side B

0.06"
0.03"

0.078"

0.05"

Pe

Page 2 of 3

Corporate Headquarters:
35 FRJ Drive
Longview, TX. 75602
Ph: (903) 753-1412
Fax: (903) 753-6112

Page 3 of 3