Sei sulla pagina 1di 36

A

DWG.NO

TT2-000-M103-00000

DRAWING LIST

NO.

DRAWING NO.

SHEET NO.

TT2-000-M103-00000

1 OF 1

P&I DIAGRAM DRAWING LIST

TT2-999-M103-00001

1 OF 3

P&I DIAGRAM SYMBOL & LEGEND (1/3)

TT2-999-M103-00002

2 OF 3

P&I DIAGRAM SYMBOL & LEGEND (2/3)

TT2-999-M103-00003

3 OF 3

P&I DIAGRAM SYMBOL & LEGEND (3/3)

TT2-311-M103-00001

1 OF 3

P&I DIAGRAM MAIN AND REHEAT STEAM SYSTEM (1/3)

TT2-311-M103-00002

2 OF 3

P&I DIAGRAM MAIN AND REHEAT STEAM SYSTEM (2/3)

TT2-311-M103-00003

3 OF 3

P&I DIAGRAM MAIN AND REHEAT STEAM SYSTEM (3/3)

TT2-313-M103-00001

1 OF 2

P&I DIAGRAM FWH EXTRACTION STEAM SYSTEM (1/2)

TT2-313-M103-00002

2 OF 2

P&I DIAGRAM FWH EXTRACTION STEAM SYSTEM (2/2)

10

TT2-314-M103-00001

1 OF 3

P&I DIAGRAM FWH VENT AND DRAIN SYSTEM (1/3)

11

TT2-314-M103-00002

2 OF 3

P&I DIAGRAM FWH VENT AND DRAIN SYSTEM (2/3)

12

TT2-314-M103-00003

3 OF 3

P&I DIAGRAM FWH VENT AND DRAIN SYSTEM (3/3)

13

TT2-318-M103-00001

1 OF 1

P&I DIAGRAM AUXILIARY STEAM SYSTEM

14

TT2-320-M103-00001

1 OF 3

P&I DIAGRAM CONDENSATE SYSTEM (1/3)

15

TT2-320-M103-00002

2 OF 3

P&I DIAGRAM CONDENSATE SYSTEM (2/3)

16

TT2-320-M103-00003

3 OF 3

P&I DIAGRAM CONDENSATE SYSTEM (3/3)

17

TT2-320-M103-00004

1 OF 1

P&I DIAGRAM CONDENSATE DRAIN SYSTEM

18

TT2-320-M103-00005

1 OF 1

P&I DIAGRAM VALVE SEALING WATER SYSTEM

19

TT2-330-M103-00001

1 OF 2

P&I DIAGRAM FEED WATER SYSTEM (1/2)

20

TT2-330-M103-00002

2 OF 2

P&I DIAGRAM FEED WATER SYSTEM (2/2)

21

TT2-350-M103-00001

1 OF 1

P&I DIAGRAM DEMI. WATER TRANSFER SYSTEM

22

TT2-360-M103-00001

1 OF 2

P&I DIAGRAM CLOSED COOLING WATER SYSTEM (1/2)

23

TT2-360-M103-00002

2 OF 2

P&I DIAGRAM CLOSED COOLING WATER SYSTEM (2/2)

24

TT2-500-M103-00001

1 OF 2

P&I DIAGRAM CIRCULATING WATER SYSTEM (1/2)

25

TT2-500-M103-00002

2 OF 2

P&I DIAGRAM CIRCULATING WATER SYSTEM (2/2)

26

TT2-913-M103-00001

1 OF 3

P&I DIAGRAM WASTE WATER TRANSFER SYSTEM (1/3)

27

TT2-913-M103-00002

2 OF 3

P&I DIAGRAM WASTE WATER TRANSFER SYSTEM (2/3)

28

TT2-913-M103-00003

3 OF 3

P&I DIAGRAM WASTE WATER TRANSFER SYSTEM (3/3)

29

TT2-919-M103-00001

1 OF 1

P&I DIAGRAM SERVICE WATER DISTRIBUTION SYSTEM

30

TT2-919-M103-00002

1 OF 1

P&I DIAGRAM RAW WATER SUPPLY SYSTEM

31

TT2-921-M103-00001

1 OF 1

P&I DIAGRAM COMPRESSED AIR SUPPLY SYSTEM

10

DRAWING TITLE

REV. NO.

SIZE

REMARKS
2

32

TT2-921-M103-00002

1 OF 1

P&I DIAGRAM INSTRUMENT AIR DISTRIBUTION SYSTEM

33

TT2-921-M103-00003

1 OF 1

P&I DIAGRAM SERVICE AIR DISTRIBUTION SYSTEM

34

TT2-923-M103-00001

1 OF 1

P&I DIAGRAM N2 FILLING SYSTEM

35

TT2-931-M103-00001

1 OF 1

P&I DIAGRAM IGNITOR FUEL OIL SYSTEM

36

TT2-142-M103-00001

1 OF 1

P&I DIAGRAM BLOW DOWN SYSTEM

10

REV.

DESCRIPTION

DATE

DRWN

CHKD

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP

12

DRAWN BY

DATE

CHECKED BY

DATE

APPROVED BY

DATE

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
DRAWING LIST
SCALE

JOB NO.

12

DRAWING NUMBER

REV.

TT2-000-M103-00000
A

A1(841x594m/m)

TT2-999-M103-00001

DWG.NO

1. MEDIA PIPING, PIPING PARTS

BS

BELLOWS SEAL

QUICK CLOSING, PISTON-ACTUATED VALVE

MAIN PROCESS LINE

UNDERGROUND PIPING

THREE-WAY VALVE

GAS TURBINE

STEAM TRAP, GENERAL


INSPECTION GLASS
(SIGHT GLASS OR PAD GLASS)

HYDRAULIC SIGNAL LINE


SPRING LOADED NON-RETURN VALVE

PNEUMATIC SIGNAL LINE

SURFACE HEAT EXCHANGER, GENERAL


WITHOUT CROSSING OF THE MEDIA FLOW

LIFT CHECK THREE-WAY VALVE

NON-RETURN VALVE

ELECTRIC MOTOR, GENERAL

STEAM TURBINE

4. ACCESSORIES

INTERNAL SYSTEM LINE


(SOFTWARE OR DATA LINE)

SURFACE HEAT EXCHANGER, GENERAL WITH


CROSSING OF THE MEDIA FLOW

AIR

7. DRIVING ENGINES

VALVE WITH CONNECTION


FOR SEALING MEDIA

SAFETY VALVE

SECONDARY PROCESS LINE

6. HEAT EXCHANGERS, STEAM


GENERATORS, COMBUSTION,
OTHERS

DIESEL ENGINE

HEAT EXCHANGER OPERATING


BY MIXING MEDIA

8. DRIVEN MACHINES

INSPECTION GLASS WITH FLOW INDICATION


HYDRAULIC PUMP, GENERAL

STEAM CONDENSER WATER COOLED


WITH HOTWELL

ELECTRICAL SIGNAL LINE

SCREWDOWN STRAIGHTWAY CHECK VALVE

FLOW LIMITER (VENTURI NOZZLE)

WALL, BUILDINGS

BALL CHECK VALVE

FLOW LIMITER (RESTRICTION ORIFICE)

PIPE LINE WITHOUT CONNECTION

BALL FLOAT VALVE

SOUND ABSORBER (SILENCER)

CENTRIFUGAL PUMP
PLATE TYPE HEAT EXCHANGER
VERTICAL PUMP

BURSTING DISC OR DIAPHRAGM

BLIND FLANGE VALVE


4

SUMP

WET PIT

CANNED

CONNECTED PIPE LINE


DIAPHRAGM VALVE

FLOW MEASURING DEVICE, GENERAL


(FLOW ORIFICE)

HOSE CLAMP

RUPTURE DISK, GENERAL

CONNECTED PIPE LINE

FLEXIBLE PIPELINE

HEATER
RECIPROCATING PUMP

DIAPHRAGM PUMP

U-TUBE HEAT EXCHANGER

STRAIGHTWAY PRESSURE REDUCING VALVE

GEAR PUMP

PRESSURE REGULATING VALVE

STEAM GENERATOR, STEAM BOILER

ANGLE PRESSURE
REDUCING VALVE

FLANGE

LIQUID JET PUMP

BACK PRESSURE REGULATING VALVE

SIPHON, LOOP

STEAM GENERATOR
WITH SUPERHEATER

STRAIGTWAY PRESSURE
REDUCING VALVE WITH INJECTION

RELIEF TO ATMOSPHERE INSIDE

ANGLE PRESSURE
REDUCING VALVE WITH INJECTION

COMPRESSOR GENERAL
(ALSO FANS, BLOWERS)

PRESSURE REGULATING VALVE


WITH EXTERNAL SENSING POINT

SCREW COMPRESSOR

FIRING, BURNER GENERAL

RELIEF TO ATMOSPHERE OUTSIDE


STRAIGHTWAY BALL VALVE
STRAIGHTWAY PLUG VALVE

VENT

OR

BACK PRESSURE REGULATING VALVE


WITH EXTERNAL SENSING POINT

ANGLE BALL OR PLUG VALVE


THREE-WAY BALL OR PLUG VALVE

EXPANSION BELLOWS
HOSE COUPLING

BUTTERFLY VALVE

SPRAY NOZZLE

BUTTERFLY VALVE WITH PROGRESSIVE


ADJUSTMENT CHARACTERISTIC

GENERATOR

SPECTACLE FLANGE

FLUID RELIEF FUNNEL


7

VACUUM PUMP

EXPANSION JOINT

COUPLING

5. FIRE FIGHTING EQUIPMENT


POST INDICATOR VALVE

SWING CHECK VALVE

COLLECTOR

FAN

THERMOWELL

LIQUID RING COMPRESSOR,


LIQUID RING VACUUM PUMP

ADDITIONAL TEST MEASURING


INSTRUMENT CONNECTION

COUPLING, GENERAL

EXHAUST FLAP

COUPLING CONTINUOUSLY VARIABLE


8

OUTDOOR FIRE HYDRANT

HYDRAULIC COUPLING

LOUVER DAMPER

FLAME ARRESTER

INDOOR HYDRANT

TRACE HEATING

GEAR, GENERAL

BUTTERFLY CHECK VALVE


DRAIN

AUTOMATIC RECIRCULATION VALVE

INDOOR FORM HYDRANT

POOL OR BASIN, GENERAL

GEAR CONTINUOUSLY VARIABLE

PIPE DIAMETER CHANGE SOCKET


(REDUCING SOCKET)

SPRINKLER SPRAY VALVE

3. ACTUATORS

9. SEPARATORS, FILTERS, ACCESSORIES

PRESSURELESS VESSEL

WATER SPRAY VALVE

PIPELINE COUPLING

FOR CONSTRUCTION

HAND-ACTUATED VALVE
PRESSURE OR VACUUM VESSEL

ELECTRIC MOTOR-ACTUATED VALVE


AIR INJECTION CHAMBER

GATE VALVE

ROTATING SEPARATOR,
CENTRIFUGAL SEPARATOR

CONTROL VALVE

SHUT-OFF VALVE, GENERAL


WITH SAFETY FUNCTION

10

SEPARATOR, GENERAL

FOAM PROPORTIONER

2. VALVES

DIAPHRAGM PRESSURE VESSEL

FOAM SEAL BOX


SOLENOID-ACTUATED VALVE

CHECK VALVE, GENERAL

FOAM POURER
FLASH TRAP, FLASH BOX

BLIND FLANGE
ACTUAT SHUT-OFF VALVE

11

WS

VESSEL WITH HEAT EXCHANGE AND SPRAY


DEAERATION (E.G.FEEDWATER TANK)

FIRE BRIGADE CONNECTION

DIAPHRAGM-ACTUATED MODULATING VALVE

STEM LEAKOFF

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

CONTRACTOR:

FLUID FILTER, FILTRATION DEVICE, GENERAL

PROJECT:

11

HOSE ROLL

GAS BOTTLE

Termotasajero 2 161.6MW CFPP

DISTRIBUTION PIPE
WATER OR FOAM MONITOR NOZZLE

CI

AIR FILTER, GAS FILTER, GENERAL

ACCUMULATOR

DRAWN BY

DATE

Y.M.KIM

26.MAR.'14

C.H.JANG

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

P&I DIAGRAM
SYMBOL & LEGEND (1/3)

26.MAR.'14

APPROVED BY

12

TITLE:

DATE

CHECKED BY

WEIGHT-LOADED VALVE

CATHODIC ISOLATION VALVE

CHKD

Termotasajero Dos S.A. E.S.P

SIEVE, SIFTER, SCREENING MACHINE,


GENERAL

SPRING-LOADED VALVE

WATER SEAL

DESCRIPTION

10

EMPLOYER:

STRAIGHTWAY SHUT-OFF GLOBE VALVE


ANGLE SHUT-OFF VALVE

DATE

S.H.KIM

12

26.MAR.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-999-M103-00001
O

REV.

1
A1(841x594m/m)

DWG.NO

TT2-999-M103-00002

9. SEPARATORS, FILTERS, ACCESSORIES

14. VALVES BODIES & FAILURE MODES

RO

7. HYDRAULIC ON-OFF VALVE

LIQUID FILTER, GENERAL

RO - RESTRICTION ORIFICE

TWO WAY (TYPICAL GLOBE SHOWN)


FO : INDICATES FAIL OPEN
FC : INDICATES FAIL CLOSED
FL : INDICATES FAIL LOCKED
(POSITION DOES NOT CHANGED)
FI : INDICATES FAIL INDETERMINATED

FO

RO

XV
NNAAANNAANNN

FO

GS+
-

GS-

GS+
NNAAANNAANNNNNNN

GSNNAAANNAANNNNNNN

FO

( )CV
NNAAANNAANNN

FOUR - WAY
FO

FG
-

GI
-

( ) : F, L, P, T

15. VALVE BODY WITH ACTUATOR-TYPICAL

MIXED-BED FILTER
FI

ION EXCHANGE FILTER

HS
-

MOV
NNAAANNAANNN

FLOW GLASS WITH INDICATION

HS
-

FE

GI+
-

GI-

GS+
NNAAANNAANNNNNNN

GSNNAAANNAANNNNNNN

MOV
NNAAANNAANNN

FE

IN

HS
-

LIMIT OF SUPPLY (WITH DESIGNATION)


O : OWNER
C : CONTRACTOR

2. INCHING MOV

VORTEX METER

CHEMICAL WATER TREATMENT PLANT

STIRRER, GENERAL

GI+
-

GI-

CORIOLIS MASS FLOWMETER

C : CONTRACTOR
S : SUPPLIER
S1

GS+
NNAAANNAANNNNNNN
M

S2

GSNNAAANNAANNNNNNN

GT
NNAAANNAANNNNNNN

IN

V-STRAINER
-

LIMIT OF SUPPLY (GRAPHICAL ONLY)

3. MODULATING MOV

GAUGE GLASS OR FLOAT


OR DISPLACEMENT TYPE OR
DIFFERENTIAL-PRESSURE TYPE

L( )

Y-STRAINER

( )CV
NNAAANNAANNN

LIMIT
INSIDE

L( )

HS
-

GI+
-

GI-

OUTSIDE

INSIDE : INSIDE OF BUILDING


OUTSIDE : OUTSIDE OF BUILDING

GI
-

CONTROL
SIGNAL

EXTERNAL CHAMBER TYPE

MODIFICATION TRIANGLE

HS
-

DUPLEX BASKET STRAINER

( ) : F, L, P, T

T-STRAINER
SIMPLEX BASKET STRAINER

LIMIT OF SUPPLY (WITH DESIGNATION)


S1 : SUPPLIER 1
S2 : SUPPLIER 2

HS
-

11. SENSORS-LEVEL

LIMIT OF SUPPLY (WITH DESIGNATION)

GI
-

CONTROL
SIGNAL

WATER TREATMENT TANK OPEN

16. SPECIAL TYPES

CONTROL
SIGNAL

CONTROL
SIGNAL

GT
NNAAANNAANNNNNNN

1. ON-OFF MOV

SIGHT GLASS

VESSEL PACKED WITH FILTER


MATERIAL (E.G. SCRUBBER)

8. HYDRAULIC MODULATING VALVE

MULTIPLE ORIFICE

MULTIPLE TUBE FILTER

HS
CONTROL
SIGNAL

THREE - WAY

FIXED-BED FILTER, GENERAL

GS+
NNAAANNAANNNNNNN

GSNNAAANNAANNNNNNN

GT
NNAAANNAANNNNNNN

SCOPE LIMIT

DESUPERHEATER

ROOM LIMIT
L( )

INTERNAL FLOAT TYPE

4. PNEUMATIC ON-OFF VALVE

AAA

10. SENSORS-FLOW

XV
NNAAANNAANNN

FE
-

HS
-

GS+
-

GS-

GS+
NNAAANNAANNNNNNN

GSNNAAANNAANNNNNNN

BBB

CONTROL
SIGNAL

L( )

FE - FLOW ORIFICE

TANK GAUGE TYPE

SPEC. BREAK

SYSTEM LIMIT : FUNCTION LEVEL

SYSTEM LIMIT : UNIT LEVEL


FE

12. SENSORS - PRESSURE


VENTURI TUBE OR FLOW
NOZZLE

5. DIAPHRAGM PNEUMATIC ON-OFF VALVE

INTERFACE POINTER TO CONNECTING


SYSTEM NAME.
COORDINATED DRAWING NUMBER OF
THE CONNECTING P&ID.

TO FEED SYSTEM
DWG. ( - )

INTERFACE POINTER TO CONNECTING


SYSTEM NAME.
COORDINATED DRAWING NUMBER OF
THE CONNECTING P&ID.

P( )
-

DIRECT CONNECTED

HS
-

XV
NNAAANNAANNN

FE
-

CONTROL
SIGNAL

10

FROM FEED SYSTEM


DWG. ( - )

DISPLACEMENT TYPE

P( )
-

GS+
-

GS-

GS+
NNAAANNAANNNNNNN

GSNNAAANNAANNNNNNN

FOR CONSTRUCTION

WITH DIAPHRAGM SEAL


FE

6. PNEUMATIC MODULATING VALVE

13. SENSORS - TEMPERATURE

ROTAMETER

( )CV
NNAAANNAANNN

11

T( )
-

FE
-

MAGNETIC FLOWMETER

TI : THERMOMETER OR
TEMPERATURE INDICATOR
TW : THERMOWELL
TE : TEMPERATURE ELEMENT

PIPING DESIGNATION FLAG


(POINTING IN FLOW DIRECTION
INCLUDING PIPING DIAMETER)

21LAB01
BR001
DN50

GI
-

( ) : F, L, P, T

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DESCRIPTION

CONTRACTOR:

11
GT
NNAAANNAANNNNNNN

PROJECT:

Termotasajero 2 161.6MW CFPP

CONTROL
SIGNAL

DRAWN BY

DATE

Y.M.KIM

15.OCT.'14

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
D

TITLE:

P&I DIAGRAM
SYMBOL & LEGEND (2/3)

DATE

C.H.JANG

APPD

Termotasajero Dos S.A. E.S.P

15.OCT.'14

APPROVED BY

CHKD

EMPLOYER:

CHECKED BY

DRWN

10

DATE

S.H.KIM

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-999-M103-00002
O

REV.

1
A1(841x594m/m)

TT2-999-M103-00003

17. CODE LETTER FOR MEASURING POINTS ACC. TO DIN-19227 PART1


SUCCEEDING LETTERS

FIRST LETTER

DISPLAY OR OUTPUT FUNCTIONS

SERIAL NUMBER OF
BREAKDOWN LEVEL

ALARM LIMIT VALUE

TITLE OF
BREAKDOWN

DISPLAY OF STATE(FOR EXAMPLE,MOTOR RUNING)

MEASURED OR INITIATING VARIABLE

MODIFIER

DENSITY

ALL ELECTRICAL VARIABLES

SENSING ELEMENT

FLOW RATE
POSITION OR LENGTH

HAND (MANUALLY INITIATED) OPERATED

GAUGING

TOTAL PLANT

LEVEL

MOISTURE OR HUMIDITY

OPTICAL VARIABLE

CODE

PROCESS COMPUTER
RESTRICTION ORIFICE, OPTICAL SIGNAL

PRESSURE OR VACUUM

QUALITY / ANALYSIS
EXCEPT D,M,V

INTEGRATEOR
TOTALIZE

TEST-POINT CONNECTION
INTEGRATING OR SUMMATING

00-40

MANUAL VALVES/DAMPERS

MIXERS, AGITATORS

41-49

MOTOR OPERATED VALVES/DAMPERS (ON/OFF, INCHING TYPE)

COMPONENT
CODE

AN

COMPRESSOR UNITS, FANS

51-59

EQUIPMENT UNIT
CODE

SYSTEM CODE

MOTOR OPERATED VALVES/DAMPERS (MODULATING TYPE)

AP

PUMP UNITS

61-69

PNEUMATIC OPERATED VALVES/DAMPERS (ON/OFF TYPE)

71-79

PNEUMATIC OPERATED VALVES/DAMPERS AND REGULATORS


(MODULATING TYPE)

81-89

HYDRAULIC OPERATED VALVES/DAMPERS


(ON/OFF AND INCHING TYPE)

AS
G

F0

A or N

F1 F2 F3 FN A 1 A2 A N

A0

B1 B2

BN

(N)

AAA

NN

AA

RADIATION VARIABLE

REGISTRATION, SELF-REGULATING

VELOCITY, SPEED OR FREQUENCY

SWITCHING, RELIEF OR SAFETY,


OPEN LOOP CONTROL

TEMPERATURE

TRANSMITTING

MULTIVARIABLE

MULTIFUNCTION UNIT

VISCOSITY

VALVE, DAMPER, LOUVRE, ACTUATING


ELEMENT, UNSPECIFIED CORRECTING UNIT

WEIGHT OR FORCE, MASS, GRAVITY

WELL

UNCLASSIFIED VARIABLES
OTHER DIMENSIONS
VIBRATION, EXPANSION,
ECCENTRICITY, SHAFT POSITION

UNCLASSIFIED PROCESSING FUNCTION

FOR COMPONENTS IN COMMON TO THE WHOLE PLANT (BOP EQUIPMENT)

TT1 (EXISTING UNIT)

TT2

IDENTIFICATION

BOILER ISLAND (BOILER, FABRIC FILTER, SDA, FUEL SYSTEM,


ASH SYSTEM, ETC.)
STEAM TURBINE/GENERATOR ISLAND (STG, BFP, CEP, FWH,
CONDENSER, AUX STEAM SYSTEM, CWP, INTAKE FACILITY, ETC.)
WATER TREATMENT ISLAND

INTERMEDIATE VALUE

MIN. LIMIT VALUE

ELECTRICAL EQUIPMENT

INSTRUMENTATION AND CONTROL EQUIPMENT

MEASURING & CONTROL (M&C)

3)_FUNCTION_KEY,_MAIN_GROUPS_F1

GENERAL SYMBOL FOR MEASURING POINT :


CODE LETTERS FOR M&C
KKS-DESIGNATION OF MEASURING POINT

POWER TRANSMISSION AND AUXILIARY POWER SUPPLY

INSTRUMENTATION AND CONTROL EQUIPMENT (IDENTIFICATION ON A


PRIORITY BASIS ACCORDING TO MAIN, INSTRUMENTATION AND CONTROL
FUNCTION ALSO ACCEPTABLE IN COMPOSITE STRUCTURE HARDWARE
PACKAGE SYSTEMS.)

PLANT CONTROL SYSTEM (PCS : PROCESS CONTROL SYSTEM)

GENERAL
-INTERCONNECTING LOGIC OR SEQUENCE CONTROL
NORMALLY USED FOR LOCAL AUXILIARY CONTROL SYSTEM
NOT NOMALLY ACCESSIBLE
-PROGRAMMABLE LOGIC CONTROLLER OR
DIGITAL LOGIC CONTROLS
INTERGRAL TO THE PROCESS CONTROL SYSTEM

SUPPLIER_DESIGNATION
-

CONVENTIONAL FUEL SUPPLY AND RESIDUES DISPOSAL

WATER SUPPLY AND DISPOSAL

CONVENTIONAL HEAT GENERATION

BY EQUIPMENT SUPPLIER
BY STG SUPPLIER

STEAM, WATER, GAS CYCLES

MAIN MACHINE SETS

PROCESS ENERGY SUPPLY FOR EXTERNAL USERS.

COOLING WATER SYSTEMS

AUXILIARY SYSTEMS

ANCILLARY SYSTEMS

STRUCTURES

RENEWABLE ENERGY PLANTS

HEAVY MACHINERY (NOT MAIN MACHINES SETS)

SITE

WORKSHOP AND OFFICE EQUIPMENT

PERFORMANCE TEST POINT


(ACCEPTANCE TEST)
PERFORMANCE CALCULATION
POINT (COMMERCIAL OPERATION)

T
12

: SERIAL NUMBER OF SUBDIVISION OF SYSTEMS AND PLANTS


: EQUIPMENT UNIT KEY

STATIONARY TOOLING, TREATMENT EQUIPMENT

AX

TEST AND MONITORING EQUIPMENT FOR PLANT MAINTENANCE

HYDRAULIC OPERATED VALVES/DAMPERS (MODULATING TYPE)

91-99

: NUMBERING FOR FIELD INSTRUMENTS

AN

MECHANICAL EQUIPMENT

BB

STORAGE EQUIPMENT (VESSELS, TANKS)

BE

SHAFTS (FOR ERECTION AND MAINTENANCE ONLY)

BF

FOUNDATIONS

BN

JET PUMPS, EJECTORS, INJECTORS

001-099

SENSING ELEMENT (ANALYZER, VIBRATION, ETC)


3

101-199

TRANSMITTER (FLOW, LEVEL, PRESSURE, TEMEPRATURE)


INCLUDING THERMOCOUPLE AND RTD.

201-299

SWITCH (FLOW, LEVEL, PRESSURE, TEMPERATURE)

3xx

NOT USED

401-499

TEST WELL, TEST POINT

501-599

LOCAL GAUGE (FLOW, LEVEL, PRESSURE, TEMPERATURE)

BP

FLOW RESTRICTORS, LIMITERS ORIFICES (NOT METERING ORIFICES)

BQ

HANGERS, SUPPORTS, RACKS, PIPING PENETRATIONS

6xx

NOT USED

BR

PIPING, DUCTWORK, CHUTES

7xx

NOT USED

BS

SILENCERS

8xx

NOT USED

BT

FLUE GAS CATALYTIC CONVERTER MODULES

9xx

NOT USED

BU

INSULATION, SHEATHING

BY

MECHANICALLY OPERATED CONTROLLERS

BZ

SPECIAL COMPONENT

A3

: ADDITIONAL IDENTIFICATION OF EQUIPMENT UNIT KEY (IF REQUIRED)

B 1 B 2 : COMPONENT IDENTIFICATION

FOR DETAILED INFORMATION, REFER TO "PROCEDURE FOR PLANT IDENTIFICATION


(KKS)"

DIRECT MEASURING CIRCUITS

CD

DENSITY

BN

CE

ELECTRICAL VARIABLES
(e.g., CURRENT, VOLTAGE, POWER, ELECTRICAL FREQUENCY)

( FOR EXAMPLE )

CF

FLOW RATE

EXAMPLE OF KKS NUMBERING

CG

DISTANCE, LENGTH, POSITION, DIRECTION OF ROTATION

FUNCTION LEVEL, EQUIPMENT UNIT LEVEL (AND COMPONENT LEVEL)

CH

MANUAL INPUT AS MANUALLY OPERATED SENSOR (e.g., FIRE DETECTOR)

CK

TIME

CL

LEVEL (ALSO FOR DIVIDING LINE)

CM

MOISTURE, HUMIDITY

CP

PRESSURE

12PAC10

CQ

QUALITY VARIABLES
(ANALYSIS, MATERIAL PROPERTIES), OTHER THAN "CD", "CM", "CV"

AP001(-M01)

CS

VELOCITY, SPEED, FREQUENCY (MECHANICAL), ACCELERATION

: SERIAL NUMBER FOR COMPONENTS OR SIGNALS

(1) IN ONE LINE WITH SPACE


12PAC10AP001(-M01) (e.g., MAIN COOLING WATER PUMP (MOTOR))
(2) IN TWO (THREE) LINES

CT

TEMPERATURE

CU

COMBINED AND OTHER VARIABLES

CV

VISCOSITY

CW

WEIGHT, MASS

CY

VIBRATION, EXPANSION

: NUMBERING FOR PIPING AND IN-PIPE-COMPONENTS


VALVES (AA A )

MECHANICAL EQUIPMENT

AA

VALVES, DAMPER, ETC. (INCL. ACTUATORS, ALSO MANUAL,


RUPTURE DISK, EQUIPMENT)

0xx

VALVES IN MAIN PIPES


SAFETY VALVES

2xx

NOT USED

3xx

ISOLATING EQUIPMENT FOR MEASURING

4xx

VALVES IN DRAINS AND FLUSHING PIPES

5xx

VALVES FOR VENTING

6xx

VALVES FOR SAMPLING AND PROPORTIONING

701-799

VALVES FOR INTERNAL CONTROLS (SOLENOID VALVE)

8xx

VALVES FOR BYPASS

9xx

NOT USED

SERIAL
N
NO.

ISOLATING ELEMENTS, AIR LOCKS

101-130

FOR CONSTRUCTION

10

PIPES (BR A )

AN

26.MAR.'13

REV.

DATE

MAIN PIPES

101-130

SUCTION AND PRESSURE RELIEF LINES ON SAFETY VALVES

2xx

NOT USED

3xx

PRESSURE LINES FOR MEASUREMENT


DRAIN, FLUSHING PIPES, PRESSURE SUPPRESSION PIPES

5xx

VENTS

AF

CONTINUOUS CONVEYORS, FEEDERS (ESCALATORS)

6xx

SAMPLING AND PROPORTIONING PIPES

DRAWN BY

AG

GENERATOR UNITS

701-799

INTERNAL INSTRUMENT LINES

CHECKED BY

AH

HEATING, COOLING AND AIR CONDITIONING UNITS

8xx

BYPASS LINES

Termotasajero 2 161.6MW CFPP


DATE

W.S.CHO

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
J

P&I DIAGRAM
SYMBOL & LEGEND (3/3)

DATE

C.H.JANG

NOT USED

TITLE:

26.MAR.'13
26.MAR.'13

APPROVED BY

APPD

CHKD

11

4xx

DRWN

PROJECT:

TURNING, DRIVING, LIFTING AND SLEWING GEAR (ALSO MANIPULATORS)

9xx

S.H.KIM

CONTRACTOR:

HEAT EXCHANGERS, HEAT TRANSFER SURFACES

DESCRIPTION

W.S.CHO C.H.JANG

Termotasajero Dos S.A. E.S.P

0xx

AE

SIZE REDUCTION EQUIPMENT, ONLY AS PART OF PROCESS

FOR CONSTRUCTION

EMPLOYER:

AC

AJ

AW

AN

A1 A2

AB

COMBUSTION EQUIPMENT

SERIAL
N
NO.

FN

INTERLOCK_IDENTIFICATION

BRAKING, GEARBOX, COUPLING EQUIPMENT, NON-ELECTRICAL CONVERTERS

AV

BY BOILER SUPPLIER

CLEANING, DRYING, FILTERING AND SEPARATING EQUIPMENT, EXCL. "BT"

AU

AN

(NOTE) FOR DETAILED INFORMATION, RETER TO "PROCEDURE FOR PLANT


IDENTIFICATION (KKS)"

10

11

AT

GRID AND DISTRIBUTION SYSTEMS

FIELD MOUNTED INSTRUMENT


MEASURMENT INDICATED ON LOCAL PANEL
(LOCAL CONTROL SYSTEM)

IDENTIFICATION

CODE

REPRESENTATION OF THE OUTPUT


AND OPERATING POINT :

ADJUSTING AND TENSIONING EQUIPMENT FOR NON-ELECTRICAL


VARIABLES (TO BE APPLIED ONLY, IF THE ACTUATOR FORMS ITSELF
A CONSTRUCTIVE UNIT WITH ANOTHER EQUIPMENT UNIT)

INCLUDING FLOW NOZZLE AND ORIFICE

COMMON FOR THE PLANT UNIT:


-AUX. COOLING WATER SYSTEM
-CLOSED COOLING WATER SYSTEM
-COMPRESSED AIR SYSTEM
-CHEMICAL DOSING SYSTEM
-POTABLE & SERVICE WATER SYSTEM

MAX. LIMIT VALUE

NN

-WASTE WATER DRAINAGE SYSTEM


-FIRE FIGHTING SYSTEM
- N 2 GAS SYSTEM
-HVAC SYSTEM

EMERGENCY OR SAFETY ACTING, TRIP

AA

2)_FUNCTION_KEY_-_F0
NUMBERING SYSTEM FOR BREAKDOWN LEVEL "1" FO

COMPUTING RELAY, RELAY,


ARITHMETIC FUNCTION

PIC
21LAB10CP101

NNN (A)

DESCRIPTION

CODE

COMPACTING AND PACKAGING EQUIPMENT, ONLY AS PART OF PROCESS

AM

NUMBERING SYSTEM FOR BREAKDOWN LEVEL "0" SHALL BE ASSIGNED AS FOLLOWS

TIME OR TIME PROGRAMME

: CATEGORIES

AK

1)_TOTAL_PLANT_(LEVEL_0)

SCAN

NOTE : THE PREFIX NUMBER OF SYSTEM CODE "Fo" IS NOT


ASSIGNED FOR THIS PROJECT.

INDICATION

TYPE OF DATA
CHARACTER

RATIO

F
G

LEVEL

DIFFERENCE

"XX"

DESIGNATION OF
DATA CHARACTER

CONTROLLING, CLOSED LOOP CONTROL

18. STRUCTURE AND APPLICATION OF KKS


BREAKDOWN_LEVELS_AND_IDENTIFICATION

DWG.NO

DATE

S.H.KIM

12

26.MAR.'13

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-999-M103-00003
O

REV.

0
A1(841x594m/m)

DWG.NO

TT2-311-M103-00001

LEGEND
- LBA : MAIN STEAM PIPING SYSTEM
1
- LBG : AUXILIARY STEAM PIPING SYSTEM
- LCM : CLEAN DRAINS SYSTEM
- QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND
VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2

REFERENCE DRAWINGS
1. P&I DIAGRAMS
- TT2 - 162 - J103 - 00002
WATER ANALYSIS SYSTEM
- TT2 - 318 - M103 - 00001
AUX. STEAM SYSTEM
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

***

***

21LBA10
BS001
4

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00085
STEAM FLOW (1/2)
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM-WATER (1/4)

21LBA10
BS002

21LBA10
AA331

FE
21LBA10CF001

21LBA10
AA321

PT
21LBA10CP102

TT
21LBA10CT101

21LBA10
AA323

**

PT
21LBA10CP103B

21LBA10
AA310
21LBA10
AA309

**

PI
-

**

PT
21LBA10CP103C

21LBA10
AA304
21LBA10
AA303

21LBA10
AA333

PI
-

TT
21LBA10CT103B

**

PT
21LBA10CP103A

21LBA10
AA308
21LBA10
AA307

**

PP
21LBA10CP401

TT
21LBA10CT103C

TP
22MAA10CT401

TO TBN MAIN STOP VALVE

TI
-

TT2-162-J103-00002 (F-2)

TO WATER ANALYSIS SYSTEM


TT2-162-J103-00002 (E-2)

HB1

FROM N2 FILLING CONNECTION

TT2-923-M103-00001 (N-3)

20QJB30
BR001 HB1
DN 25

20QJB30
AA001

20QJB30
BR002 BA3
DN 25

20QJB30
AA002

MOV
22LCM11AA441
IN

22LCM11 TO START-UP FLASH TANK


BR402 BA1
TT2-320-M103-00004 (B-3)
DN 50

BA1

STG TP3
22MAA16
BR410
DN 25

PI
-

TI
-

PT
22LAH10CP101

TT
22LAH10CT101

FROM MSV WARMING


TT2-STG-M103-00010-1 (C-3)

BA1

22LBA10
BR401 BA3
DN 200

WS

WS

22LAH10
AA302
22LAH10
AA301

22LAH10
BR402 BA1
DN 200

TT2-320-M103-00001 (J-9)
9

FOR CONSTRUCTION

22LAH10
BR411 GA1
DN 40

22LAH10
AA401

BS

BA1

22LBA10
AA401

TO CONDENSER FLASH TANK

GA1

PCV
22LBA10AA461

BS

BS

TT2-STG-M103-00010-1 (B-2)

22LCM11 22LCM11
AA401
BR401 BA3
DN 50
LO

200 x 150

TO WATER ANALYSIS SYSTEM


22QUB10 22QUB10
AA601 AA602

TT
22LCM10CT103

22LBG11
BR001 BA3
DN 150

TT2-318-M103-00001 (B-6)

TT
21LBA10CT103A

STG TP1

22QUB10 22QUB10
AA603 AA604

TO AUX. STEAM HEADER

**

21LBA10
AA312
21LBA10
AA311

21LBA10
AA306
21LBA10
AA305

DN25

22QUB10
BR602 BC1
DN 25

BC1

TP
22MAA10CT402

21LBA10
BR001 BA3
DN 450

21LBA10
AA334

PI
-

*
*

21LBA10
AA103

FT
21LBA10CF101A

TI
-

22QUB10 22QUB10
AA002
AA001

TT2-BLR-J-161-00085 (C23)

21LBA10
AA332

PI
-

50 x 25

21LBA10
AA302
21LBA10
AA301

***

21LBA10
AA324

DN200

S
FROM SUPERHEATER OUTLET

21LBA10
AA314
21LBA10
AA313

TT
21LBA10CT102

*
*

PT
21LBA10CP104

21LBA10
AA322

TI
-

21LBA10
AA403

PT
21LBA10CP101

TI
-

FT
21LBA10CF101B

21LBA10
AA404

***

TI
FI
-

22QUB10
BR601 BA3
DN 25

PSV
21LBA10AA101

*
*

TI
-

***

*
*

PSV
21LBA10AA102

DN 400
BR102 BA3
21LBA10

***

DN 300
BR101 BA3
21LBA10

I
PI
-

10

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

20.JAN.'15

CHECKED BY

DATE

Y.W.SEONG

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
MAIN AND REHEAT STEAM SYSTEM
(1/3)
SCALE

JOB NO.

DRAWING NUMBER

TT2-311-M103-00001
O

12
REV.

4
A1(841x594m/m)

DWG.NO

TT2-311-M103-00002

LEGEND
- LAF : IP DESUPER HEATING SPRAY SYSTEM
- LBC : COLD REHEAT PIPING SYSTEM
- LBG : AUXILIARY STEAM PIPING SYSTEM
- LBQ : EXTRACTION STEAM PIPING SYSTEM
FOR HP FEEDWATER HEATING
- LCM : CLEAN DRAINS SYSTEM
- QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND
VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. FLOW ELEMENT IS SUPPLIED BY B&W.

REFERENCE DRAWINGS
1. P&I DIAGRAMS
- TT2 - 313 - M103 - 00001
FWH EXTRACTION STEAM SYSTEM (1/2)
- TT2 - 318 - M103 - 00001
AUX. STEAM SYSTEM
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 330 - M103 - 00001
FEED WATER SYSTEM (1/2)
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

***

***

22LBC20
BS002

FROM TBN HPT CASING


PREWARMING

22LBG42
BR002 EB2
DN 100

TT2-STG-M103-00010-1 (E-3)

22LBC20
BS001

TT
22LBC20CT101

TT
22LBC10CT101

PT
22LBC10CP101

***

22LBC20
BR001 EB1
DN 600

TO REHEATER INLET
TT2-BLR-J-161-00085 (C23)

22LBC10
BR003 EB2
DN 600

REHEATER ATTEMPERATOR

22LBQ20
BR001 EB1
DN 200

TO HP FWH NO. 6

TT2-313-M103-00001 (B-3)

**

PI
-

22LBC10
BR003 EB2
DN 600

TT
22LBC10CT102

PT
22LBC10CP102

PP
22LAF90CP401

TT
22LAF90CT101

*** M

***

MOV
22LAF90AA041
22LAF90
AA001

***

LO

***
80 x 50

***
22LAF90
AA401
***
22LAF90

FC

22LBC10
AA302
22LBC10
AA301

TI
-

PI
-

TT
22LBC10CT103

PT
22LBC10CP103

TT2-318-M103-00001 (A-3)

S
FROM HP TURBINE EXHAUST

TT2-STG-M103-00010-1 (C-4)

STG TP4A

TP
22LBC10CT404
TP
22LBC10CT402

22LBC10
AA312
22LBC10
AA311

DN 400
BR002 EB2
22LBC10

PP
22LBC10CP402
22LBC10
AA314
22LBC10
AA313

S
FROM HP TURBINE EXHAUST
TT2-STG-M103-00010-1 (C-4)

STG TP4B

22LBC10 22LBC10
AA321 AA322

80 x 50

22LBC10 22LBC10
AA332 AA331

***

TCV
22LAF90AA072

TO TBN GLAND SEAL


TT2-STG-M103-00010-1 (D-2)

22LAF90
BR401 EB1
DN 25

22LBG21
BR001 EB1
DN 100

TO AUX. STEAM HEADER


TP
22LAF90CT401

22LBC10
AA304
22LBC10
AA303

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00085
STEAM FLOW (1/2)
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM - WATER

PP
22LBC10CP401

DN 400
BR001 EB1
22LBC10

LO

AA402

TP
22LBC10CT401

22LBW10
STG TP68
BR001 EB1
DN 65
22LBW10

LA+
-

AA001

TO PRESSURE STEAM
FOR IP VALVE
TT2-STG-M103-00010-1 (E-1)

MOV
22LCM13AA441

50 x 25
BS

TT2-923-M103-00001 (N-3)

22LCM12
AA401

BS

20QJB35
AA001

10

20QJB35
BR002 EB2
DN 25

IN

WS

22LCM12
BR402 EB2
DN 100

TO CONDENSER FLASH TANK

TT2-320-M103-00001 (J-8)

EB2
BS
22LCM12
AA411

22LCM13
AA403
50 x 25

22LCM13 22LCM13 22LCM13


AA402
AA401
AT401

22LCM12
BR401 EB2
DN 100

LO
EB1

20QJB35
BR001 HB1
DN 25

MOV
22LCM12AA441

IN

LA++
-

22LBC10 22LBC10
AA323 AA324

STG TP12

BS

TT2-320-M103-00001 (K-9)

FROM N2 FILLING CONNECTION

LSHH
22LBC10CL202

22LBC10 22LBC10
AA334 AA333

22LBC30
BR001 EB2
DN 40

TO CONDENSER FLASH TANK

LSH
22LBC10CL201

22LCM12
AT401

DN25

22LCM12
AA412

FOR CONSTRUCTION

22LBC10
AA403

PT
22LAF90CP101

***
22LAF90
AA002

TP
22LBC10CT403

20QJB35
AA002

22LBC10
AA404

DN 80
BR001 EB1
NOTE 2
22LAF90

TI
-

22LAF90 22LAF90
AA321 AA322

FE
22LAF90CF001

22LAF90 22LAF90
AA302 AA304

***

XV
22LBC10AA061

TI
-

22LAF90
AA003

4
22LAF90 22LAF90
AA311 AA312

TT2-330-M103-00001 (N-8)

22LAF90 22LAF90
AA301 AA303

FROM BFP INTERSTAGE


DISCHARGE

FT
22LAF90CF101

***

PI
-

FI
-

22LBC10
AA306
22LBC10
AA305

**

STG TP72

PI
-

TP
22LBC20CT401

TI
-

***

TI
-

DN300

***

DN25

PSV
22LBC20AA101

22LBC11
BR001 EB2
DN 300

***

DN50

PSV
22LBC20AA102

22LCM13
BR401EB2

***

DN 600
BR101 EB1
22LBC20

DN 600
BR102 EB1
22LBC20

HB1

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

20.JAN.'15

CHECKED BY

DATE

Y.W.SEONG

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
MAIN AND REHEAT STEAM SYSTEM
(2/3)

SCALE

JOB NO.

DRAWING NUMBER

TT2-311-M103-00002
O

12
REV.

4
A1(841x594m/m)

DWG.NO

TT2-311-M103-00003

LEGEND
- LBB : HOT REHEAT PIPING SYSTEM
1
- LCM : CLEAN DRAINS SYSTEM
- QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2
- QUB : SAMPLING SYSTEM FOR STEAM SYSTEM

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND
VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2

REFERENCE DRAWINGS
1. P&I DIAGRAMS
- TT2 - 162 - J103 - 00003
WATER SAMPLING SYSTEM
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)

PI
-

**

TI
-

PT
21LBB21CP102
21LBB21
AA302
21LBB21
AA301

FROM WARMING THROUGH OF


MSV

**

PP
21LBB21CP402

TT
21LBB21CT102C

TI
-

**

**

TT
21LBB21CT102B

TT
21LBB21CT102A

TP
22MAB10CT402

21LBB21
AA304
21LBB21
AA303

TI
-

TP
22MAB10CT401

21LBB21
BR001 DA1
DN 500

22MAA16
BR010
DN 65

TT2-STG-M103-00010-1 (A-2)

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00085
STEAM FLOW (1/2)
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM - WATER

TI
-

TO REHEAT STOP VALVE

STG TP10A

TT2-STG-M103-00010-1 (A-4)
4

TT
21LBB21CT101
MOV
21LCM21AA441

DN250

***

21LBB10
BS001

21LCM21
AA401

DN25

650 x 500

650 x 500

22QUB20 22QUB20
AA602
AA601
BC1

TT2-923-M103-00001 (N-3)

BR002 DA1
DN 25

20QJB36
AA002

21LCM22
AA401

22QUB20
TO WATER ANALYSIS SYSTEM
BR601 BC1
TT2-162-J103-00003 (B-2)
DN 25
22QUB20 22QUB20
AA605

LO

AA606

TO WATER ANALYSIS SYSTEM


8

20QJB36 20QJB36
AA001

TT2-320-M103-00004 (B-2)

HB1

20QJB36
BR001 HB1
DN 25

FROM N2 FILLING CONNECTION

TO START-UP FLASH TANK

21LCM22
BR401 DA1
DN 80

21LBB10
BR001 DA1
DN 650
22QUB20
BR602 DA1
DN 25

TT2-BLR-J-161-00085 (C-9)

21LBB10
AA302
21LBB10
AA301

21LCM21
BR401 DA1
DN 80

21LBB21 21LBB21
AA401
AA402

21LBB22
AA402

IN

21LBB22
AA401

FROM REHEATER OUTLET

TT
21LBB10CT101

DN25

S
6

TP
21LBB10CT401

PSV
21LBB10AA101

PT
21LBB10CP101

***

LO

22QUB20 22QUB20
AA603 AA604

PI
-

TT2-162-J103-00003 (B-2)

**

TI
-

PT
21LBB22CP101
21LBB22
AA302
21LBB22
AA301

**

PP
21LBB22CP401

TT
21LBB22CT101C

TI
-

TI
-

**

**

TT
21LBB22CT101B

TT
21LBB22CT101A

DN250

TI
-

STG TP2

PI
-

DN 400
BR101
21LBB10

TT
21LBB22CT102
TI
-

21LBB22
AA304
21LBB22
AA303

TP
22MAB20CT402

C
21LBB22
BR001 DA1
DN 500

TP
22MAB20CT401

S
TO REHEAT STOP VALVE

STG TP10B

TT2-STG-M103-00010-1 (A-5)

FOR CONSTRUCTION

10

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

15.OCT.'14

CHECKED BY

DATE

Y.W.SEONG

15.OCT.'14

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

15.OCT.'14

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
MAIN AND REHEAT STEAM SYSTEM
(3/3)

SCALE

JOB NO.

DRAWING NUMBER

TT2-311-M103-00003
O

12
REV.

2
A1(841x594m/m)

DWG.NO

TT2-313-M103-00001

LEGEND
- LAA : HP FEEDWATER HEATING SYSTEM
- LBD : EXTRACTION PIPING SYSTEM
- LBG : AUAXILIARY STEAM PIPING SYSTEM
- LBQ : EXTRACTION STEAM PIPING
FOR HP FEEDWATER HEATING
- LCM : CLEAN DRAIN SYSTEM
- QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2

PI
-

22LBQ10
BR001 GA1
DN 150

TT2-STG-M103-00010-1 (C-6)

22LBQ10
AA301

22LBQ10
AA311

TT2-STG-M103-00010-1 (C-7)

TI
-

TI
-

TT
22LBQ20CT102

TT
22LBQ10CT102

TT
22LBD10CT102

DN25

MOV
22LBQ10AA041

FROM HP FWH NO.5 LVL HH

22LBQ10
AA402

WS

LO

TT2-314-M103-00001 (G-6)

22LBQ20
AA401

22LBQ10
BR402 GA1
DN 25

TBN TRIP

FO

DN 50
BR401 GA1
22LBQ10

TT2-314-M103-00001 (N-5)

TT2-320-M103-00001 (N-5)

LO

DN 50

FO

XV
22LBD10AA062

TT2-320-M103-00001 (N-6)

BS

DN 50
BR401 GB1
22LBD10

22LBD10
BR411 GB1
DN 50

WS
FO

LO

TO CONDENSER FLASH TANK

TT2-320-M103-00001 (N-7)

TO CONDENSER FLASH TANK

TT2-320-M103-00001 (N-7)

XV
22LBD10AA462
DN25

DN150
22LBQ10
AA411

22LBQ20
AA411

22LBD10
AA412

FC

**

DN25

XV
22LBQ10AA062

22LBD10
AA2287

XV
22LBD10AA461

**

2. VENDOR DWG.
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM - WATER

22LBD10
AA411

XV
22LBD10AA063

DN150

**

XV
22LBQ20AA461

WS
FO

LO

TO CONDENSER FLASH TANK

DN200

22LBD10
AA402

**

**

22LBQ20

WS BR401 EB1

MOV
22LBD10AA041

TO CONDENSER FLASH TANK

22LBD10

22LBD10
AA401

FROM DEA LVL HHH

XV
22LBQ10AA465
22LBQ20
AA402

22LBD10
AA2286

DN300

TBN TRIP

22LBQ10
AT401

22LBQ10
AA401

22LBQ10
AA422
BS

22LBQ10
AA421

DN150

TT2-STG-M103-00010-1 (D-6)

TT2-314-M103-00001 (G-5)

TT2-STG-M103-00010-1 (D-6)

FROM TBN NOZZLE ADAPTOR


DRAIN

22MAA10
BR460
DN 25

STG TP34B

FROM HP FWH NO.6 LVL HH

FROM TBN NOZZLE ADAPTOR


DRAIN

22MAA01
BR470
DN 25

1. P&I DIAGRAMS
- TT2 - 311 - M103 - 00002
MAIN AND REHEAT SYSTEM (2/3)
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 318 - M103 - 00001
AUX. STEAM SYSTEM
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

22LBD10
BR001 GB1
DN 300

REFERENCE DRAWINGS

TI
-

DN200

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

STG TP15
TP
22LBD10CT401

MOV
22LBQ20AA041

NOTES

22LBD10
AA311

22LBD10
AA301

TP
22LBQ10CT401

STG TP34A

TBN TRIP

PT
22LBD10CP101

TP
22LBQ20CT401

PP
22LBD10CP401

FROM IP TURBINE INTERSTAGE

STG TP17

22LBD10
BR402 GB1
DN 25

FROM IP TURBINE INTERSTAGE

DN25

22LBQ20
AA311

PT
22LBQ10CP101

FC

22LBQ20
AA301

PP
22LBQ10CP401

TT2-311-M103-00002 (G-6)

22LBQ20
BR001 EB1
DN 200

**

PT
22LBQ20CP101

FC

PP
22LBQ20CP401

FROM HP TURBINE EXHAUST


(COLD REHEAT)

PI
-

PI
-

GB1

HB1

22LBG54
AA003

PT
22LBQ20CP102
8

PP
22LBQ20CP402

LO

22LBQ20
AA321

22LBQ10
AA412

22LBQ20
TO CONDENSER FLASH TANK
BR411 EB1
TT2-320-M103-00001 (N-6)
DN 50

WS
FO

PI
PT
22LBQ10CP102

XV
22LBQ20AA462

22LBQ20
AA331

PP
22LBQ10CP402

LO

22LBQ10
AA321

22LBQ10
BR411 GA1
DN 50

WS
FO

TO CONDENDSER FLASH TANK

TT2-320-M103-00001 (N-5)

LC
22LBD10
AA321

PT
22LBD10CP102

XV
22LBQ10AA466

22LBQ10
AA331

PI
-

I
GB1

22LBD10
AA331

PP
22LBD10CP402

HB1

22LBG54 22LBG54
BR002 GB1 AA002 200 x 150
DN 200
LO
FC

22LBG54
200 x 150 AA005
LO

22LBG54
BR001 HB1
DN 200

FROM AUX. STEAM HEADER

PCV
22LBG54AA071

TI
-

20QJB39
AA002

S1

PP
22LAD20CP403

22LAD20
AA313

S8B

TT2-923-M103-00001 (K-7)

20QJB38
BR001 HB1
DN 25

20QJB38
BR002 GA1
DN 25

20QJB38
AA001

22LAD20
AA323

20QJB38
AA002

S8C

S1

HP FEEDWATER HEATER NO.6


(1 X 100%)
22LAD20
S8A
AC001

PI
22LAD10CP503

22LAD10
AA313

S8B

PP
22LAD10CP403

PT
22LAA10CP103

22LAD10
AA323

S8C

P3

HP FEEDWATER HEATER NO.5


(1 X 100%)
22LAD10
S8A
AC001

TO STRAT-UP FLASH TANK

20QJB39
AA001

PI
22LAD20CP503

FROM N2 FILLING CONNECTION

PI
-

BR002 EB1
DN 25

TP
22LBD10CT402

10

TT2-923-M103-00001 (K-3)

20QJB39
BR001 HB1
DN 25

FROM N2 FILLING SYSTEM

22LBQ10
AA501

HB1

22LBQ20
20QJB39 AA501

HB1

21LCM54
BR401 HB1
DN 25

TT
22LBD10CT103

22LAA10
AA303

P23

DEAERATOR
(1 X 100%)
22LAA10
AC001

22LBG54
AA004

TP
22LBQ10CT402

FOR CONSTRUCTION

TP
22LBQ20CT402

200 x 150

MOV
22LBG54AA041

22LBG54
BR003 GB1
DN 150

TT
22LBQ10CT103

22LBG54
AA401

22LBG54
AA801

TT
22LBQ20CT103

22LBG54 21LCM54 22LBG54


AA412 AT001
AA411

TI
-

GB1

TT2-320-M103-00004 (B-4)

TI
-

TT2-318-M103-00001 (N-7)

22LBG54
AA041

22LBQ20
AA412
PI
-

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11

TI
22LAD20CT501

TI
22LAD10CT501

FEEDWATER STORAGE TANK


(1 X 100%)
22LAA10
BB001

PROJECT:

Termotasajero 2 161.6MW CFPP

P15

DRAWN BY

DATE

B.S.KIM

20.JAN.'15

DATE

CHECKED BY
J.W.SEO

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
FWH EXTRACTION STEAM SYSTEM (1/2)

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-313-M103-00001
O

REV.

4
A1(841x594m/m)

12

DWG.NO

TT2-313-M103-00002

LEGEND
1
- LBS : EXTRACTION STEAM PIPING SYSTEM
FOR LP FEEDWATER HEATING
- LCC : LP FEEDWATER HEATING SYSTEM
- LCM : CLEAN DRAINS SYSTEM
- MAC : LP TURBINE
- QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2

22LBS30
BR001 HB1
DN 350

TT2-STG-M103-00010-1 (C-7)

TI
-

TT
22LBS20CT101

TT
22LBS30CT102

TP
22LBS20CT401

22MAW50
BR010 HB1
DN 200

STG TP31

XV
22LBS30AA062
DN350

FROM LP FWH NO.3 LVL HH

22LBS20
AA421

TT2-320-M103-00001 (N-8)

22LBS20
AA411

FC

TO CONDENSER FLASH TANK

**

XV
22LBS20AA062

TT2-314-M103-00002 (I-4)

MOV
22LBS30AA041

22LBS20

BS BR401 HB1

DN 50

FO

LO

FROM STG GLAND STEAM


TT2-STG-M103-00010-2 (D-4)

22MAW30
BR020
DN 150

FO

LO

DN350

PP
22LBS11CP402

22LBS20
AA412

TT2-320-M103-00001 (N-9)

PT
22LBS30CP102
PP
22LBS30CP402

22LBS20
BR402 HB1
DN 50

BS
FO

LO

PT
22LBS20CP102

22LBS30
AA331

PP
22LBS20CP402

S1

STG TP32

*
22LBS11
AA302

PP
22LBS12CP402

22LBS11
AA301

22LBS12
AA302

TO CONDENSER FLASH TANK

PI
-

TT2-320-M103-00001 (N-8)
PT
22LBS12CP101

XV
22LBS20AA466
PI
-

S2

PI
-

TO CONDENSER FLASH TANK

22LBS30
AA321

S1

TT2-320-M103-00001 (N-8)

22LBS20
AA403

XV
22LBS30AA462
PI
-

2. VENDOR DWG.
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM - WATER

PT
22LBS11CP101

22LBS30
BR402 HB1
DN 50

PP
22LBS12CP401

TO CONDENSER FLASH TANK

MOV
22LBS20AA041

BS

*
22LBS12
AA303

1. P&I DIAGRAMS
- TT2 - 314 - M103 - 00002
FWH VENT AND DRAIN SYSTEM (2/3)
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

XV
22LBS20AA465

FROM LP FWH NO.2 LVL HH

22LBS30
AA412

BS

DN350
22LBS20
AA401

TBN TRIP

22LBS30
AA411

TT2-314-M103-00002 (I-3)

BS

XV
22LBS30AA461

DN25

DN 50

FO

LO

REFERENCE DRAWINGS

22LBS11
AA303

22LBS20 22LBS20
AT401
AA422

TP
22LBS11CT402

22LBS20
AA321

22LBS12
AA301

TI
-

22LBS20
AA331

TP
22LBS12CT402
TI
-

TT
22LBS11CT102

TT
22LBS12CT101

TP
22LBS30CT402

TP
22LBS20CT402

S3
NOTE 3

20QJB41
AA002

PI
22LCC30CP501

S1

22LCC30
AA303

S8B

PP
22LCC30CP403

FROM N2 FILLING CONNECTION

TT2-923-M103-00001 (K-4)

22LCC30
AA304

AA001

AA002

S8C

PI
22LCC20CP501

S1

LP FEEDWATER HEATER NO.3


(1 X 100%)
22LCC30
AC001
S8A

S8B

22LCC20
AA303

S8B

PP
22LCC10CP401

S8C
9

FOR CONSTRUCTION

S8A

22LBS20

20QJB42
20QJB42
AA501
BR001 HB1
BR002 HB1
DN 25
DN
25
20QJB42
20QJB42

TI
22LCC10CT501

PP
22LCC20CP403

20QJB41
AA001

22LBS30

20QJB41
AA501
BR002 HB1
DN 25

TT2-923-M103-00001 (K-6)

HB1

20QJB41
BR001 HB1
DN 25

HB1

FROM N2 FILLING CONNECTION

LP FEEDWATER HEATER NO.1 NOTE 3


(1 X 100%)
22LCC10
AC001

PI
22LCC10CP501

S2

TT
22LBS20CT102

22LCC10
AA304

TT
22LBS30CT103

22LCC10
AA303

TI
-

S2

TI
-

S3

10

DN25

**

22LBS30

BS BR401 HB1

STG TP45

FROM HP GLAND STEAM

FC

**

22LBS30
AA402

S2

TT2-STG-M103-00010-1 (D-7)

**

22LBS30
AT401

22LBS30
AA401

PP
22LBS11CP401

22LBS30
BR411 HB1
DN 25

AA421

DN350

AA422

22LBS20
AA301

NOTE 3

I 22LBS30 22LBS30

TBN TRIP

S2

PP
22LBS20CP401

22LBS20
AA311

22LBS20
BR001 HB1
DN 350

TI
-

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. THERMOWELL SHALL BE PROVIDED
BY CONDENSER SUPPLIER
3. S1 : STEAM TURBINE SUPPLIER
S2 : CONDENSER SUPPLIER
S3 : LP FEEDWATER HEATER SUPPLIER

PI
-

TP
22LBS30CT401

NOTES

NOTE 3

PT
22LBS20CP101

S2

S2

22LBS30
AA311

22LBS30
AA301

22LBS12
BR001 HB1
DN 550

FROM IP TURBINE EXHAUST

22LBS11
BR001 HB1
DN 550

PT
22LBS30CP101

22LBS20
BR411 HB1
DN 25

PP
22LBS30CP401

S1

PI
-

S1

LP TURBINE
(1 X 100%)
22MAC10
MT001

22LCC20
AA304

CONDENSER
(1 X 100%)
22MAG10
AC001

S8C

LP FEEDWATER HEATER NO.2


(1 X 100%)
22LCC20
AC001
S8A

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM

J.W.SEO

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11

TI
22LCC30CT501

TI
22LCC20CT501

PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

20.JAN.'15

DATE

CHECKED BY
J.W.SEO

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
FWH EXTRACTION STEAM SYSTEM (2/2)

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-313-M103-00002
O

REV.

4
A1(841x594m/m)

12

DWG.NO

TT2-314-M103-00001

LEGEND
- LAA : STORAGE, DEAERATION
- LAD : HP FEEDWATER HEATING SYSTEM
- LCH : HP HEATER DRAINS SYSTEM
- LCK : DEAERATOR FEEDWATER DRAIN SYSTEM
- LCM : CLEAN DRAINS SYSTEM

22LCH40
BR461 EB2
DN 25

NOTES

LCV
22LCH41AA471

22LAA10
AA311

P21F

P9

EQ2

DC2

EQ4

P18 P13A

FEEDWATER STORAGE TANK


(1 X 100%)
22LAA10
BB001 P19
P22

TT
22LAA10CT104

*
22LCK10
AA401

P11

22LCH30
BR401 EB2
DN 150

TT2-330-M103-00002 (B-11)
HP FWH NO.5 EXTRACTION SHUT
OFF
22LCH31
200 x 80 AA402

TT2-314-M103-00002 (E-12)

FC

22LCH20
BR461 GB1
DN 25

22LCH31
BR401 EA1
DN 200

TT
22LCH10CT101

IN

MOV
22LCK10AA441

FO
22LCK20
AA411

TO CONDENSER

WS

TT2-320-M103-00001 (K-5)

22LCK20
AA402

TO CONDENSATE STORAGE TANK

LI
-

*
*

22LAD10
AA321

22LAD10
AA342

LT
22LAD10CL101C

LT
22LAD10CL101B

LG
22LAD10CL501

22LAD10
AA311

22LAD10
AA332

22LAD10
AA331

22LAD10
AA341

LI
-

LI
-

I
22LCH21
TO CONDENSER
WS
BR401 GA1
TT2-320-M103-00001 (B-5)
200 x 80 DN 200 22LCH21

WS
FO

22LCH20
AA411

22LCH10
BR401 GB1
DN 150

LT
22LAD10CL101A

22LAD10
AA322

22LAD10
AA411

LCV
22LCH21AA471
22LCH20
AA401 150 x 80

TI
-

22LAD10
AA312

22LCH20
BR452 GB1
DN 25

TP
22LCH10CT401

TT2-313-M103-00001 (J-5)

TT2-350-M103-00001 (A-4)

22LAD10
AA301

TT2-330-M103-00001 (B-8)

22LCK10
AA411

*
*

22LCH10
AA301

S9A

22LCH10
AA411

PP
22LCH10CP401

LI
-

DEAERATOR EXTRACTION
SHUTOFF

22LCK20
AA401

22LAD10
AA302

22LCH20
BR401 GB1
DN 150

22LAA10
AA341B

XV
22LCK20AA468

22LAD10
AA511

S4

22LAA10
AA341A

LG
22LAA10CL502B

BOILER FEED PUMP TRIP

WS

HP FEEDWATER HEATER NO.5


(1 X 100%)
22LAD10
S2
S3 AC001
S9B

22LAA10
AA331

EA1

LG
22LAA10CL502A

22LAA10
AA342B

LA++
-

LCV
22LCH31AA071

LI
-

LA+++
-

22LCK11
BR401 HB1
DN 100

FEEDWATER WARMING-UP

22LAA10
AA342A

TT2-313-M103-00001 (F-7)

22LCH30
AA411

22LAA10
AA321

LA--

22LAA10
AA332

LT
22LAA10CL102C

TT2-320-M103-00003 (E-1)

HP FWH NO.5 BY-PASS

1. P&I DIAGRAMS
- TT2 - 313 - M103 - 00001
FWH EXTRACTION STEAM SYSTEM (1/2)
- TT2 - 314 - M103 - 00002
FWH VENT AND DRAIN SYSTEM (2/3)
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00003
CONDENSATE SYSTEM (3/3)
- TT2 - 330 - M103 - 00001
FEED WATER SYSTEM (1/2)
- TT2 - 330 - M103 - 00002
FEED WATER SYSTEM (2/2)
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM

22LAA10
AA314

22LAA10*
AA411

TT2-313-M103-00001 (B-7)

22LCH30
AA401 150 x 80

P13B

LI
-

LCV AT OUTLET OF GSC

HP FWH NO.6 EXTRACTION SHUT


OFF

LA++
-

22LAA10
AA322

LT
22LAA10CL102B

TA+/-

TT2-330-M103-00002 (B-6)

22LAA10
AA313

PP

TI
22LAA10CT501

HP FWH NO.6 BY-PASS

AA402

22LAA10
AA511

LI
-

22LCH41
TO CONDENSER
WS
BR401 EA1
TT2-320-M103-00001 (B-5)
DN
200
22LCH41
200 x 100

P21E P14A P14B

WS

FO

22LCH40
AA411

TT
22LCH30CT101

LI
-

22LAA10
AA302

22LCK20
BR401 HB1
DN 200

LI
-

22LCH40
AA401 200 x 100

TI
-

22LAA10
AA312

22LCK10
BR401 HB1
DN 200

TP
22LCH30CT401

22LAA10*
AA301

22LAD20
AA341

LT
22LAA10CL102A

22LCH40
BR452 EB2
DN 25

22LCH40
BR401 EB2
DN 200

22LCH30
AA301

EQ3

SPARE

REFERENCE DRAWINGS

22LAD20
AA331

DC1

PI
22LAA10CP501

EQ1

LT
22LAD20CL101C

22LAD20
AA321

DEAERATOR
(1 X 100%)
22LAA10
AC001

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

PP
22LAA10CP401

22LAD20
AA311

LT
22LAD20CL101B

P4

22LAD20
AA411

PP
22LCH30CP401

LG
22LAD20CL501

22LAD20
AA342

22LAB10
BR451 GB1
DN 25

22LAD20
AA301

22LAD20
AA332

LT
22LAD20CL101A

22LAD20
AA322

HP FEEDWATER HEATER NO.6


(1 X 100%)
22LAD20
S2
S3 AC001
S9B

22LAD20
AA312

S9A

22LAD20
AA302

22LAD20
AA511
2

LA++
-

FOR CONSTRUCTION

AA402

GA1

I
22LCH11
BR401 GA1
DN 200

10

LCV
22LCH11AA072
22LCH10
AA401 150 x 80

200 x 80

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

22LCH10
AA412

FC

Termotasajero Dos S.A. E.S.P

22LCH11
AA402
CONTRACTOR:

GA1
11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

20.JAN.'15

DATE

CHECKED BY
Y.W.SEONG

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

20.JAN.'15

APPROVED BY

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
FWH VENT AND DRAIN SYSTEM (1/3)
SCALE

JOB NO.

DRAWING NUMBER

TT2-314-M103-00001
O

12
REV.

4
A1(841x594m/m)

22LCJ70
BR452 HB1
DN 25

LG
22LCC30CL501

22LCC30
AA332

LT
22LCC30CL101B

22LCC30
AA321

22LCC30
AA331

LI
-

DN 50

22LCJ20
BR401 HB1
DN 150
B

G2

E
DN 100

PP
22LCJ11CP401

TP
22LCJ11CT401

WS

WS
22LCJ51
AA401

FO

22LCJ51
TO CONDENSER
BR401 HA1
TT2-320-M103-00001 (J-6)
DN 200

*
*

22LCJ13
AA411

HB1
22LCJ11

AA401
22LCJ11
WS
BR401 HB1
DN 150

PI
-

PDIS
22LCJ21CP201

PT
22LCJ21CP101

22LCJ21
AA301

22LCJ21*
AA302

*
22LCJ21
AT001

22LCJ21
AA303

22LCJ21
BR401 HB1
DN 100

PI
22LCJ21CP501

TI
22LCJ21CT501

22LCJ21
AA304

22LCJ23
AA301

22LCJ23
AA401

100 x 65

PDIS
22LCJ22CP201

22LCJ22
AA301

22LCJ22*
AA302

*
11

22LCJ22
AT001
22LCK11
AA001

PI
-

22LCK11
BR401 HB1
DN 100

PT
22LCJ22CP111

22LCJ22
AA303

22LCJ22
BR401 HB1
DN 100

PI
22LCJ22CP501

TI
22LCJ22CT501

22LCJ24
AA301

FO

22LCJ24
AA401

*
*

22LCC10
AA331

LI
-

22LCC10
AA341

LI
-

DN 200

22LCJ14
AA401

TO CONDENSER

LP FWH NO.1 BY PASS

LA++
-

TT2-320-M103-00001 (K-5)

TT2-320-M103-00003 (E-8)

HA1
WS
FO

22LCJ12
AA401

22LCJ12

WS BR401 HA1

DN 200

TO CONDENSER

TT2-320-M103-00001 (J-5)

LCV
22LCJ12AA071

FI
-

FOR CONSTRUCTION

FT
22LCJ30CF101
FE
22LCJ30CF001

22LCJ30
AA302

LCV
22LCJ30AA071
22LCJ30
AA405

22LCJ30
BR401 GB1
DN 80

TO CONDENSATE LINE

TT2-320-M103-00003 (H-4)

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

Termotasajero Dos S.A. E.S.P

22LCJ24
AA402
CONTRACTOR:

11

(2 X 100%)

RO
22LCJ40BP002

XV
22LCJ42AA401

Termotasajero 2 161.6MW CFPP

22LCJ40
AA002

LP HEATER DRAIN PUMPS

LT
22LCC10CL101C

PROJECT:

DRAWN BY

DATE

B.S.KIM

20.JAN.'15

DATE

CHECKED BY

22LCJ40
BR402 GB1
DN 40

FO

WS BR401 HA1

FC

22LCJ24
BR401 GB1
DN 80

80 x 50

22LCJ20
AP001

12

EMPLOYER:

100 x 65

TT2-314-M103-00001 (I-6)

LI
-

22LCJ14

WS

22LCJ30
AA301

PI
22LCJ24CP501

22LCJ22
AA304

FEEDWATER WARMING-UP

22LCC10
AA321

22LCC10
AA342

22LCJ23
AA402

22LCJ40
AA001

22LCJ10
AP001

PDA+
-

22LCC10
AA311

LT
22LCC10CL101B

HA1

22LCJ23
BR401 GB1
DN 80

80 x 50

RO
22LCJ40BP001

22LCJ22
AA401

LG
22LCC10CL501

22LCC10
AA332

PI
22LCJ23CP501

22LCJ21
AA401

LCV
22LCJ51AA471

PDA+
-

22LCC10
AA301

22LCJ13
AA401

TT
22LCJ11CT101

LT
22LCC10CL101A

22LCC10
AA322

22LCC10
AA411

LCV
22LCJ14AA471

TI
-

LI
-

22LCJ21
AA002

22LCJ11
AA301

22LCC10
AA312

LP FEEDWATER HEATER NO.1


(1 X 100%)
22LCC10
S2
S3 AC001
S9B

22LCC20
AA341

22LCC20
AA411

S9A

LT
22LCC20CL101C

22LCC20
AA331

22LCC10
AA302

22LCJ13
BR452 HB1
DN 25

22LCC20
AA321

*
LT
22LCC20CL101B

22LCC20
AA342

22LCC20
AA311

22LCC20
AA332

22LCJ13
BR401 HB1
DN 150

LG
22LCC20CL501

22LCC20
AA301

22LCC20
AA322

22LCC20
AA312

22LCJ11
AA411

TP
22LCJ21CT401

10

22LCC10
AA511

*
DN 40

22LCJ21
BR401 HB1
DN 100

LI
-

DN 100

22LCJ20
BR451 HB1
DN 100

22LCJ21
AA001

22LCJ42
BR401 GB1
DN 40

F2

SPARE

LT
22LCJ20CL101

LI
-

D
F1 DN 40*

LP HEATER DRAIN TANK


(1 X 100%)
22LCJ20
BB001

LG
22LCJ20CL501

TT2-313-M103-00002 (F-6)

HB1

22LCJ50
AA411

LP FWH NO.2 EXTRACTION SHUT


OFF

22LCJ50
AA401

TT
22LCJ20CT101

DN 200
C

G1

TT2-313-M103-00002 (A-6)

22LCJ40
BR403 GB1
DN 40

DN 50

LI
-

LT
22LCC20CL101A

22LCJ50
BR452 HB1
DN 25

22LCJ20
AA403

*
*

LP FWH NO.3 EXTRACTION SHUT


OFF

LA++
-

S9A

*
22LCJ50
BR401 HB1
DN 200

22LCJ20
AA301

TI
-

22LCJ20
BR551 HB1
DN 200

1. P&I DIAGRAMS
- TT2 - 313 - M103 - 00002
FWH EXTRACTION STEAM SYSTEM (2/2)
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00003
CONDENSATE SYSTEM (3/3)

22LCC20
AA302

*
S4

REFERENCE DRAWINGS

LI
-

2. VENDOR DWG.
LPHDP SUPPLIER DWG.
- TT2 - CEP - J103 - 00002
P&I DIAGRAM OF LPHDP

LP FEEDWATER HEATER NO.2


(1 X 100%)
22LCC20
S2
S3 AC001
S9B

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

22LCC30
AA341

AA511

S11

NOTES

LCV
22LCJ41AA071

22LCJ41
BR401 HA1
DN 100
4 22LCJ50
BR461 HB1
DN 25
22LCC20

- LCC : LP FEEDWATER HEATING SYSTEM


- LCJ : LP HEATER DRAINS SYSTEM
- LCK : DEAERATOR FEEDWATER DRAIN SYSTEM
- LCM : CLEAN DRAINS SYSTEM

LA++
-

FC

22LCJ20
BR501 HB1
DN 200

TP
22LCJ20CT401

LCV
22LCJ71AA471

22LCJ41
AA402

22LCJ40
AA411

22LCC30
AA342

LI
-

22LCJ71
TO CONDENSER
BR401 HA1
TT2-320-M103-00001 (K-6)
DN 200

FO

22LCJ40
BR401 HB1
DN 80
22LCJ40
AA401

PP
22LCJ20CP401

LT
22LCC30CL101C

HA1
4

22LCJ71
AA402
WS
WS

22LCJ70
AA411

22LCC30
AA311

22LCC30
AA322

22LCC30
AA301

HA1

22LCJ70
AA401

TT
22LCJ40CT101

22LCJ13
BR461 HB1
DN 25

TI
-

LT
22LCC30CL101A

22LCC30
AA411

22LCJ70
BR401 HB1
DN 150

TP
22LCJ40CT401

22LCC30
AA312

TT2-314-M103-00002

22LCC30
AA302

S9A

22LCJ40
AA301

LEGEND

LP FEEDWATER HEATER NO.3


(1 X 100%)
22LCC30
S2
S3 AC001
S9B

PP
22LCJ40CP401

22LCJ70 22LCC30
BR461 HB1 AA511
DN 25

DWG.NO

Y.W.SEONG

20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
I

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
FWH VENT AND DRAIN SYSTEM (2/3)

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-314-M103-00002
O

REV.

4
A1(841x594m/m)

TT2-314-M103-00003

DWG.NO

LEGEND
- LAA : STORAGE, DEAERATOR
1
- LAD : HP FEEDWATER HEATING SYSTEM
- LCC : LP FEEDWATER HEATING SYSTEM
- LCH : HP HEATER DRAINS SYSTEM
- LCJ : LP HEATER DRAINS SYSTEM
- MAL : DRAIN AND VENT SYSTEM
- QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2

*
22MAL60
AA501

PSV
22MAL60AA101

*
22MAL63
AA501

S5

IN SIDE

22MAL60
BR101 HB1
DN 100

S12

RO
22MAL30BP001

OUT SIDE

*
22MAL30
AA501

22MAL53
BR002 GB1
DN 25

MOV
22MAL53AA541

22MAL53
BR001 GC2
DN 25

50 x 25

RO
22MAL50BP001

*
22MAL50
AA501

TO START-UP FLASH TANK

TT2-320-M103-00004 (B-8)

PSV
22MAL50AA101

S12

*
22LAD10
AA401

S10

22LCJ30
AA402

TO CONDENSER FLASH TANK

TT2-320-M103-00001 (N-4)

RO
22MAL20BP001

PSV
22MAL20AA101

IN SIDE

22MAL20
BR101 HB1
DN 100

22MAL20*
AA501

S5

OUT SIDE
6

S10

LP FEEDWATER HEATER NO.2


(1 X 100%)
22LCC20
S6
AC001 S7

22LAD10
BR402 EB2
DN 50

22LAD10
BR401 EB2
DN 25

22MAL10
BS003
RO
22MAL10BP001

22LCJ20
AA401

22LCJ20
BR411 HB1
DN 25

ATM

S10

22MAL20
BR501 HC1
DN 25

*
22LAD10
AA402

1. P&I DIAGRAMS
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

OUT SIDE

OUT SIDE

22MAL10
BS001

22LCJ30
AA401

HP FEEDWATER HEATER NO.5


(1 X 100%)
22LAD10
AC001 S7
S6

IN SIDE

IN SIDE

22MAL50
BR101 HB1
DN 100

*
22MAL53
AA501

S5

PSV
22MAL30AA101

22MAL30
BR101 HB1
DN 100

S12

22LCJ30
BR411 HB1
DN 25

22LAD20
BR402 EB2
DN 50

GB1

22MAL50
BR501 GC2
DN 50

*
22MAL31
AA502

S5

22LCJ20
AA402

RO
22MAL10BP003

MOV
22MAL10AA541

22MAL10
AA503
20QJB31
AA502

20QJB31
AA001

20QJB31
BR001 HB1
DN 25

TT2-923-M103-00001 (K-7)

22MAL50
AA502

PSV
22MAL10AA101

P8A

P8B P10A

10

*
22MAL10
BR503 HB1
DN 50

DN 50
BR502 HB2
22MAL10

22MAL60*
AA502

P7A

DEAERATOR
(1 X 100%)
22LAA10
AC001

P7B

PSV
22MAL10AA102

P10B

TO CONDENSER FLASH TANK

TT2-320-M103-00001 (N-4)

FOR CONSTRUCTION

MOV
22MAL12AA541

RO
22MAL11BP001

22MAL11
AA501

S5

22MAL12
AA502

S11

LP FEEDWATER HEATER NO.1


(1 X 100%)
22LCC10
AC001 S7
S6

FEEDWATER STORAGE TANK


(1 X 100%)
22LAA10
BB001

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

22LCJ10
AA402

11
PROJECT:

22LCJ10
BR402 HB1
DN 50

22LCJ10
AA401

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

20.JAN.'15

DATE

Y.W.SEONG

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
C

APPD

Termotasajero Dos S.A. E.S.P

20.JAN.'15

APPROVED BY

CHKD

EMPLOYER:

CHECKED BY

DRWN

10

CONTRACTOR:

22LCJ10
BR401 HB1
DN 25

11

22MAL10
BR501 HC1
DN 50

FROM N2 FILLING CONNECTION

22MAL12
BR501 HC1
DN 25

22MAL10
AA501

DN20

22MAL11
BR501 HC1
DN 50

REFERENCE DRAWINGS

LP FEEDWATER HEATER NO.3


(1 X 100%)
22LCC30
AC001 S7
S6

*
22LAD20
AA402

22LAD20
BR401 EB2
DN 25

MOV
22MAL31AA541

S10

HP FEEDWATER HEATER NO.6


(1 X 100%)
22LAD20
AC001 S7
S6

*
22LAD20
AA401

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

TT2-320-M103-00001 (N-4)

M
22MAL31
BR501 HC1
DN 25

RO
22MAL60BP001
DN25

TT2-320-M103-00004 (B-8)

NOTES

TO CONDENSER FLASH TANK

22LCJ30
BR412 HB1
DN 50

50 x 25

MOV
22MAL63AA541

22MAL30
BR501 HC1
DN 25

TO START-UP FLASH TANK

22LCJ20
BR412 HB1
DN 50

22MAL60
BR501 EC2
DN 50

M
22MAL63
BR001 EC2
DN 25

EB2

22MAL63
BR502 EB2
DN 25

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
FWH VENT AND DRAIN SYSTEM (3/3)

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-314-M103-00003
O

REV.

3
A1(841x594m/m)

22LCE10
BR001 GB1
DN 50

DWG.NO

TT2-318-M103-00001

DN100

4
TO START UP FLASH TANK
3

22LCE12
AA004

21LBG51
AA401

22LCM51
BR401 HB1
DN 25

PI
-

*
21LCM53 21LCM53 21LCM53
AA411
AT401
AA412

21LBG53
AA401

22LCE11
AA801

FC
22LCE11
AA004

TI
-

12

22LCM42
AA412

MOV
22LCM42AA441

22LCM42
AT401

22LCM42
AA411

DN25

21LBG52
AA312

TT
12LBG43CT101

DN150
DN150
DN25

12LBG43
AA001

FOR CONSTRUCTION

12LBG43 12LBG43 12LBG43


AA441
AT404
AA442
12LBG43
AA443

IN

PSV
22LBG32AA101

22LBG32
BR001 HB1
DN 300

TI
-

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

TT
22LBG32CT105

PROJECT:

50 x 25

22LCM32
AT401

22LBG32
AA401

22LCM32
AA411

DRAWN BY

DATE

B.S.KIM

20.JAN.'15

CHECKED BY
Y.W.SEONG

TITLE:

P&I DIAGRAM
AUXILIARY STEAM SYSTEM

DATE
20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
J

Termotasajero 2 161.6MW CFPP


22LCM32
AA412

12LBG43
AA433

DN25

22LBG54
AA001

22LCM32
BR401 HB1
DN 50

PCV
22LBG30AA071

12LBG43 12LBG43 12LBG43


AA421 AT402
AA422
12LBG43
AA423

MOV
22LCM32AA442

TO START-UP FLASH TANK

21LBG52AA061D
21LBG52CF001D
21LBG52CF101D
21LBG52AA071D
21LBG52CP501D
21LBG52CP101D
21LBG52AA341
21LBG52AA342
21LBG52AA042
21LBG52BR041
21LBG52BR042

12LBG43
AA002

DN150

21LBG53
AA001

TO PULV. D

21LBG52AA061C
21LBG52CF001C
21LBG52CF101C
21LBG52AA071C
21LBG52CP501C
21LBG52CP101C
21LBG52AA331
21LBG52AA332
21LBG52AA032
21LBG52BR031
21LBG52BR032

HEADER

TT
22LBG32CT101
21LBG52
AA001

TO PULV. C

21LBG52AA061B
21LBG52CF001B
21LBG52CF101B
21LBG52AA071B
21LBG52CP501B
21LBG52CP101B
21LBG52AA321
21LBG52AA322
21LBG52AA022
21LBG52BR021
21LBG52BR022

O TO UNIT #1 AUX. STEAM

12LBG43 12LBG43 12LBG43


AA411
AT401
AA412
12LBG43
AA401

TI
-

21LBG51
AA001

TO PULV. B

12LBG43 12LBG43 12LBG43


AA431
AT403
AA432

50 x 25

PI
-

DN150

MOV
12LBG43AA044

TT
22LBG32CT104

NOTE 3

MOV
22LBG30AA041

PT
22LBG32CP101B

TT2-320-M103-00004 (B-6)

SUFFIX COMPARISON TABLE


TO PULV. A
(Shown)
21LBG52AA061A
21LBG52CF001A
21LBG52CF101A
21LBG52AA071A
21LBG52CP501A
21LBG52CP101A
21LBG52AA311
21LBG52AA312
21LBG52AA012
21LBG52BR011
21LBG52BR012

TT2-313-M103-00001 (O-9)

AUX. STEAM HEADER

GB1

EB1

22LBG42
AA001

TI
-

TI
-

PT
22LBG32CP101A

TT
22LBG30CT101B

TT
22LBG42CT101
22LBG42
AA401

50 x 25

22LCM42
BR401 EB1
DN 50

IN

DN150

150 x 100

TT2-320-M103-00004 (B-7)

22LBG30
BR001 GB1
DN 300

22LBG42
BR001 EB1
DN 150

STG TP09

TO START-UP FLASH TANK

22LBG30
AA303

TT
22LBG30CT101A

TT2-320-M103-00004 (B-4)

TO DEAERATOR PEGGING

TO STRAT-UP FLASH TANK

DN25

TT2-STG-M103-00010-1 (D-1)

22LBG30
AA302

TI
22LBG30CT501

PI
-

PI
-

TI
-

22LBG30
BR002 GB1
DN 250

TO TBN GLAND SEAL


STEAM & TBN HPT CASING
PREWARMING LINE
11

22LBG54
BR001 HB1
DN 200

12LBG43
BR001 HB1
DN 300
22LBG30
AA301

PT
22LBG30CP101B

22LBG32
AA302

PT
22LBG30CP101A

TI
-

22LBG31
BR001 HB1
DN 300

PI
22LBG30CP501

PI
-

21LCM53
BR401 HB1
DN 25

22LCE11
AA003

TCV
22LCE11AA071

22LBG30
BR101 GB1
DN 200

PI
-

TO AIR HEATER SOOT BLOWER

200 x 50

21LCM53
AA801

MOV
12LBG43AA043

PSV
22LBG30AA101

10

TT2-320-M103-00004 (B-3)

22LBG12
BR001 GB1
DN 300

21LBG53 21LBG53
AA002
AA003

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00088
SECONDARY AIR SYSTEM
- TT2 - BLR - J - 161 - 00089
HOWDEN TRI-SECTOR AIR HEATER
- TT2 - BLR - J - 161 - 00093
PULVERIZER INERTING & CLEARING
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM - WATER

TO STRAT-UP FLASH TANK

PT
12LBG43CP101

22LCE11
BR002 GB1
DN 25

NOTE 2

22LCM52
BR401 HB1
DN 25

TT2-BLR-J-161-00089 (F-22)

22LBG11 22LBG11 22LBG11


AA412 AT401 AA411

TT2-BLR-J-161-00093 (J-15)

22LCM52
AA811

DN25

21LBG53
BR001 HB1
DN 200

AA004

22LCE13
AA802

TT2-320-M103-00004 ( )

MOV
21LBG53AA041

DN25

AA005

DN25

DN100

22LBG22
BR001 GB1
DN 250

22LCE13
BR001 GB1
DN 50
22LCE13 50 x 25 FC 50 x 25 22LCE13

NOTE 3

21LBG52
AA411

DN25

TO START UP FLASH TANK

TCV
22LCE13AA073

TO PULVERIZER A INERTING

1. P&I DIAGRAMS
- TT2 - 311 - M103 - 00001
MAIN AND REHEAT STEAM SYSTEM (1/3)
- TT2 - 311 - M103 - 00002
MAIN AND REHEAT STEAM SYSTEM (2/3)
- TT2 - 313 - M103 - 00001
FWH EXTRACTION STEAM SYSTEM (1/2)
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM

FROM CO2 EXTINGUISHING


LINE
TT2-570-F103-00011

DN 150
BR012 HB1
21LBG52

21LBG52
AA012

22LCM52 22LCM52 22LCM52


AT411 AA412
AA411

DN100

PCV
22LBG11AA071

22LBG11
BR401 BA3
DN 25

TT2-311-M103-00001 (B-8)

PCV
21LBG52AA071A

21LBG52
BR001 HB1
DN 150

22LBG11
BR001 BA3
DN 150

FROM MAIN STEAM LINE

150 x 65

21LBG52
AA311

FE
21LBG52CF001A

21LBG52
BR011 HB1
DN 65

XV
21LBG52AA061A

MOV
22LBG11AA041

REFERENCE DRAWINGS

PT
21LBG52CP101A

FT
21LBG52CF101A

TT
22LBG11CT101

TT2-320-M103-00004 (B-3)

PI
21LBG52CP501A

22LBC11 22LBC11 22LBC11


AA412 AT401 AA411

TI
-

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. AUX. STEAM SYSTEM TO PULVERIZER A IS
SHOWN. AUX. STEAM SYSTEM TO PULVERIZER
B THRU D ARE IDENTICAL EXCEPT FOR TAG
NUMBER SUFFIX. PLEASE FIND SUFFIX
COMPARISON TABLE BELOW.
3. THESE VALVES ARE PCV AND DESUPERHEATER
INTEGRATED TYPE.

TO STRAT-UP FLASH TANK

22LCM51
AA801

22LCE12
AA801

TT2-320-M103-00004 (B-9)

FC

22LCE12
BR001 GB1
DN 25

NOTES

22LCM51 22LCM51 22LCM51


AA411 AT401
AA412

NOTE 3
22LCE12
AA005

21LBG51
AA002

FC

21LBG51
AA402

TCV
22LCE12AA072

22LBC11
BR401 EB1
DN 25

TT2-311-M103-00002 (J-7)

- LBG : AUXILIARY STEAM PIPING SYSTEM


- LCE : CONDENSATE DESUPERHEATING
SPRAY SYSTEM
- LCM : CLEAN DRAINS SYSTEM
(COLLECTING AND RETURN SYSTEM)

TT2-142-M103-00001 (B-4)
21LBG51
AA003

DN25

22LBG21
BR001 EB1
DN 100

FROM COLD REHEAT STEAM LINE

PCV
22LBG21AA071

LEGEND

TCV
21LBG51AA061

TO STEAM COIL AIR HEATER

I
M

TT2-320-M103-00002 (B-9)

22LCE10
AA002

21LBG51
BR001 HB1
DN 150

MOV
22LBG21AA041

FROM CEP DISCHARGE

DN150

22LBG32
BR101 HB1
DN 200

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-318-M103-00001
O

REV.

4
A1(841x594m/m)

FL

TT2-320-M103-00001

**

PP
22MAG10CP401B

PP
22MAG10CP401C

PP
22MAG10CP401D

PP
22MAG10CP401E

22LCM20
AS001

PP
22MAG10CP401F

14

S1 22MAW40

22MAJ50
BR010
DN 80

S2

TO CONDENSER VACUUM
PUMP

32A

S1

32D

32C

32B

32F

32E

S1 22MAL02

BR010
DN 250
22LCM70
BR001 HB1
13
DN 300
22LCA42
*
TI
200 x 150 BR001 GB1
22MAG10CT501
15
DN 150
S2 S1 22MAM30
BR010
16
DN 40
27
22LCK20
BR401 HB1
17
DN 200
22LCJ12
BR401 HA1
18
DN 200
22LCJ14
BR401 HA1
19
DN 200
22LCJ51
BR401 HA1
20
DN 200
22LCJ71
BR401 HA1
21
DN 200
*
37D

FROM HP FWH NO.6 EMERGENCY


DRAIN

TT2-314-M103-00001 (E-4)

*
33

10

22LCH41
BR401 EA1
DN 200

TP
22MAG10CT401B

48A

22LCH21
BR401 GA1
DN 200

TT2-314-M103-00001 (E-10)

TP
22MAG10CT401A

TT
22MAG10CT101

34

48B

CONDENSER
(1 X 100%)
22MAG10
AC001

11

TO START-UP FLASH TANK

S1

S2

12

22MAG10
AA308

35B

WS

22LCA13
BR001 GB1
DN 250

*
22LCA13
AA001

*
22LCB10
AA301

22LCB10
AA302

PI
22LCB10CP501

*
*

22LCP61
AA301

FROM CONDENSATE TRANSFER


PUMP DISCHARGE

22LCP56
BR001 HC1
DN 25

TT2-350-M103-00001 (N-12)

GB1

*
*
HC1

MOV
22LCA13AA041

*
*

PI
22LCP61CP501

NOTE 3

TT2-162-J103-00001 (C-2)

22QUC10
AA601

TO SAMPLING SYSTEM
TT2-162-J103-00001 (C-2)

OXYGEN SCAVENGER INJECTION


TT2-161-W103-00001 (I-10)

AMMONIA INJECTION

12

TT2-161-W103-00001 (L-10)

BS

BS

PDA
-

22QUC10
AA602

22MAG10
AA333

37F

22MAG10
AA334

23
28A
28B

90

TT2-320-M103-00004 (N-10)

89

FROM CEP MINIMUM RECIR.

TI
22LCM20CT501

TT2-320-M103-00002 (B-2)

FROM DEAERATOR OVERFLOW


LINE

TT2-314-M103-00001 (N-6)
FROM LP FWH NO.1 DRAIN LINE

TT2-314-M103-00002 (K-8)

DN 200
BR001 HC1
22LCM06

88

FROM LP FWH NO.1


EMERGENCY DRAIN

TT2-314-M103-00002 (K-7)

FROM LP FWH NO.2


EMERGENCY DRAIN

TT2-314-M103-00002 (F-7)

QI
-

QIT
22MAG10CQ004

QI
-

BS

*
*

GS
22LCB20AA001

FROM LP FWH NO.3


EMERGENCY DRAIN

*
*

22LCA12
AA501
22LCA12
AS001

22LCB20
AA301

22LCB20
AA302

PI
22LCB20CP501

*
*

TT2-STG-M103-00010-2 (E-2)

DN 200
BR001 EB2
22LCM04

22LCP62
AA301

*
*

S1

96

FROM COLD REHEAT STEAM


DRAIN

22LCM12
BR402 EB2
DN 100

TT2-311-M103-00002 (N-9)

TT2-314-M103-00003 (N-2)

DN 200
BR001 GB1
22LCM03

93

DN 200
BR001 HB1
22LCM02

84

22LAH10
BR402 BA1
DN 200

FROM MAIN STEAM

TT2-311-M103-00001 (N-9)

81

TT2-313-M103-00001 (J-7)
FROM HP FWH NO.5
EXTRACTION LINE DRAIN 1

TT2-313-M103-00001 (J-6)
FROM HP FWH NO.6
EXTRACTION LINE DRAIN 2

22LBQ20
BR411 EB1
DN 50

TT2-313-M103-00001 (F-8)
FROM HP FWH NO.6
EXTRACTION LINE DRAIN 1

TT2-311-M103-00002 (G-10)

92

PI
22LCB20CP502

4
22LCM07
BR401
DN 50

PI
22LCP62CP501

DN150
SPARE

TT2-313-M103-00001 (F-6)

22LBD10
BR401 GB1
DN 50

22LBS20
BR402 HB1
DN 50

22LBS30
BR401 HB1
DN 50
22LBS30
BR402 HB1
DN 50

FROM COLD REHEAT STEAM

94
82

TT2-313-M103-00001 (N-6)
FROM DEAERATOR HEATING
STEAM LINE DRAIN 2

TT2-313-M103-00001 (N-7)

*
MOV
22LCA14AA041

22QUC10
BR602 GC2
DN 25

PI
-

NOTE 3

PT
22LCA20CP101A

PT
22LCA20CP101B

25 x 15

22LCA20
AA301

TI
-

22LCA20
AA302

PP
22LCA20CP401

TT
22LCA20CT101

TI
22LCA20CT501

TP
22LCA20CT401A

TP
22LCA20CT401B

TP
22LCA20CT401C

22LCA20
AA303

TT2-313-M103-00002 (J-7)
FROM LP FWH NO.2
EXTRACTION LINE DRAIN 1

DESCRIPTION

TAG NUMBER

GLOBE VALVE
CHECK VALVE
STRAINER
FLOW GLASS
RESTRICTION ORIFICE
RESTRICTION ORIFICE

22LCP61/62AA001
22LCP61/62AA002
22LCP61/62AT001
22LCP61/62CF501
22LCP61/62BP002
22LCP61/62BP001

TT2-313-M103-00002 (J-6)

FROM LP FWH NO.3


EXTRACTION LINE DRAIN 1

TT2-313-M103-00002 (F-6)
FROM LP FWH NO.3
EXTRACTION LINE DRAIN 2

TT2-313-M103-00002 (F-7)
9

FOR CONSTRUCTION

22LCM07
AA401

20.JAN.'15

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

10

EMPLOYER:

22LCA20
BR001 GB1
DN 250

22QUC10
AA001

Termotasajero Dos S.A. E.S.P

TO GLAND STEAM CONDENSER

TT2-320-M103-00002 (B-8)

CONTRACTOR:

11
PROJECT:

GB1
GB1

20QCA11
BR001 GC1
DN 15

20QCA11 20QCA11
AA001
AA002

20QCD11
BR001 GC1
DN 15

20QCD11
AA001

PI
-

FROM LP FWH NO.2


EXTRACTION LINE DRAIN 2

CONDENSER FLASH TANK


(1 X 100%)
22LCM20
BB001

2. VENDOR DWG.
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 2
STEAM - WATER
CEP SUPPLIER DWG.
- TT2 - CEP - J103 - 00001
P&I DIAGRAM OF CEP

FROM DEAERATOR HEATING


STEAM LINE DRAIN 1

DN 200
BR001 HB1
22LCM01

83

FROM HP FWH NO.5


EXTRACTION LINE DRAIN 2

22LBS20
BR401 HB1
DN 50

22LCB20
AP001

TT2-314-M103-00003 (N-5)
FROM LP FWH NO.3 VENT

22LBD10
BR411 GB1
DN 50

S2
85

DN 50
BR501 GB1
22LCA12

50 x 25

22MAL01
BR010
DN 200

FROM HP STEAM DRAIN

PDIS
22LCA12CP201
BS 22LCA12
AA302

TT2-314-M103-00003 (N-8)
FROM LP FWH NO.2 VENT

22LBQ20
BR401 EB1
DN 50
86

PDA
-

FROM LP FWH NO.1 VENT

22LBQ10
BR411 GA1
DN 50

DN 200
BR001 GA1
22LCM05

87

GI
-

22LCA12
AA301
BS
*

22MAL10
BR501 HC1
DN 50
22MAL20
BR501 HC1
DN 25
22MAL30
BR501 HC1
DN 25

1. P&I DIAGRAMS
- TT2 - 161 - W103 - 00001
AMMONIA INJECTION SYSTEM
- TT2 - 162 - J103 - 00001
SAMPLING SYSTEM
- TT2 - 311 - M103 - 00001
MAIN AND REHEAT STEAM SYSTEM (1/3)
- TT2 - 311 - M103 - 00002
MAIN AND REHEAT STEAM SYSTEM (2/3)
- TT2 - 313 - M103 - 00001
FWH EXTRACTION STEAM SYSTEM (1/2)
- TT2 - 313 - M103 - 00002
FWH EXTRACTION STEAM SYSTEM (2/2)
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 314 - M103 - 00002
FWH VENT AND DRAIN SYSTEM (2/3)
- TT2 - 314 - M103 - 00003
FWH VENT AND DRAIN SYSTEM (3/3)
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 320 - M103 - 00005
VALVE SEALING WATER SYSTEM
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM

TI
-

22LBQ10
BR401 GA1
DN 50

TT2-314-M103-00002 (F-4)

QIT
22MAG10CQ003

REFERENCE DRAWINGS

TT
22LCM20CT101

FROM GLAND STEAM


CONDENSER DRAIN

TP
22LCA12CT401B

TP
22LCA12CT401C

22LCA14
BR001 GB1
DN 250
22LCA14
AA001

TP
22LCA12CT401A

*
22LCA12
AT001

25 x 15

TO SAMPLING SYSTEM

11

GI
-

22LCA12
AA502

PI
22LCB10CP502

CONDENSATE EXTRACTION
PUMPS
(2 X 100%)
22LCB10
AP001

*
10

22LCA11
AS001

HC1

22LCA11
AA501

37E

PDIS
22LCA11CP201
BS 22LCA11
AA302

22LCA11
BR101 HB1
DN 400

BS

BS
22LCA11
AA502

TP
22LCA11CT401B

TP
22LCA11CT401C

GS
22LCA11AA001
22LCA11
AA301
BS
*

22LCA11
BR501 GB1
DN 50

50 x 25

91

80

FROM START-UP FLASH TANK

(TT2-STG-M103-00010-2 (E-4))

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. S1 : STEAM TURBINE SUPPLIER
S2 : CONDENSER SUPPLIER
3. TAG NUMBERS WHICH ARE SUPPLIED
BY VENDOR REFER TO THE BELOW TABLE.

FROM LP STEAM DRAIN

TT2-320-M103-00002 (H-9)

NOTES

3B
TP
22LCA11CT401A

*
22LCA11
AT001

3A

22LCA11
AA001

BS

22MAG10
AA

LT
22MAG10CL101C

22MAG10
AA322

29 26

36B

LT
22MAG10CL101B

22LCA12
BR001 HB1
DN 400

80 x 40

DN 80
BR003 HB1
21HLC21

LT
22MAG10CL101A

*
BS

22MAG10
AA307
LG
22MAG10CL502
BS
*

22LCA12
AA001

22MAG10
AA332

22MAG10
AA313

37C

22MAG10
AA331

36A

22MAG10
AA311

BS

22MAG10
BR401 HB1
DN 100

37B

BS

22MAG10
AA321

WS

TT2-142-M103-00001 (B-11)

35A

WS

FROM STEAM COIL AIR


PREHEATER DRAIN

TT2-STG-M103-00010-2 (E-4)

22LCA12
BR101 HB1
DN 400

DN 25
BR002 HB1
22LCW29

TT2-320-M103-00005 (E-11)

37A

BS

FROM SEAL WATER HEADER

QIT
22MAG10CQ002

22MAG10
AA

22MAG10
AA314

QI
-

BS

TT2-350-M103-00001 (N-2)

QIT
22MAG10CQ001

BS

QI
-

22MAG10
AA312

TO CONDENSATE TRANSFER
PUMP DISCHARGE LEVEL
CONTROL VALVE

22LCM20
BR501
DN 750

TT2-320-M103-00002 (N-8)

BS

22

TT2-STG-M103-00010-2 (D-2)

22LCA11
BR001 HB1
DN 400

TO CONDENSER OVERFLOW
LINE

GB1

FROM IP VALVE CHAMBER


PREHEATING

22MAG10
AA405

TT2-320-M103-00004 (N-9)

22MAG10
AA315

TT2-350-M103-00001 (N-7)
FROM HP FWH NO.5 EMERGENCY
DRAIN

4B

22MAG10
AA316

WS

22LCP10
BR001 HC1
DN 100

PT
22MAG10CP101B
BS

200 x 150

PT
22MAG10CP101A

4A

TI
-

22MAG10
AA306

22LDC10
AA002

PI
-

BS

FROM CONDENSATE TRANSFER


PUMP

WS

PI
-

22MAG10
AA305

TT2-CON-E170-00004

22LDC10
AA001

22LDC10
BR001 HB1
DN 200

TT2-320-M103-00002 (B-12)

TT2-STG-M103-00010-2 (E-2)

47

TT2-CON-E170-00004

FROM STG GLAND STEAM

BR010
DN 150

49

S2

200 x 150

22LCE23
AA401

- LCC : LP FEEDWATER HEATING SYSTEM


- MAG : CONDENSING SYSTEM
- LCM : CLEAN DRAINS SYSTEM
(COLLECTING AND RETURN SYSTEM)
- LCA : MAIN CONDENSATE PIPING SYSTEM
- LCB : MAIN CONDENSATE PUMP SYSTEM
- LCE : CONDENSATE DESUPERHEATING
SPRAY SYSTEM

FROM CEP DISCHARGE

S2

TT2-CON-E170-00004

TO CONDENSER VACUUM
PUMP

22LCE23
BR001 GB1
DN 100

BS

PP
22MAG10CP401A

MOV
22MAJ50AA041

22LCE23
AA002

WS

**

**

DWG.NO

WS

LP FEEDWATER HEATER NO.1


(1 X 100%)
22LCC10
AC001

LEGEND

WS

TCV
22LCE23AA401

Termotasajero 2 161.6MW CFPP

DRAWN BY

DATE

J.H.PARK

20.JAN.'15

K.Y.LEE

20QCD11
AA002
GB1
F

P&I DIAGRAM
CONDENSATE SYSTEM (1/3)

20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.

TITLE:

DATE

CHECKED BY

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-320-M103-00001
O

REV.

4
A1(841x594m/m)

DWG.NO

TT2-320-M103-00002

LEGEND
- LCA : MAIN CONDENSSATE PIPING SYSTEM
- LCE : CONDENSATE DESUPERHEATING
SPRAY SYSTEM
- MAW : SEALING, HEATING AND COOLING
STEAM SYSTEM

FCV
22LCA31AA071
22LCA31
AA002
WS

TO CONDENSATE
RECIRCULATION

NOTES

22LCA31
WS AA001
FO

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

22LCA31
AA401

TT2-320-M103-00001 (K-4)

1. P&I DIAGRAMS
- TT2 - 161 - W103 - 00001
CHEMICAL FEED SYSTEM
- TT2 - 162 - J103 - 00001
SAMPLING SYSTEM
- TT2 - 318 - M103 - 00001
AUXILIARY STEAM SYSTEM
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00003
CONDENSATE SYSTEM (3/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 320 - M103 - 00005
VALVE SEALING WATER SYSTEM
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM
- TT2 - 360 - M103 - 00001
CLOSED COOLING WATER SYSTEM (1/2)
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

22LCA31
AA801

SEE STEAM TURBINE DWG. (TT2-STG-M103-00010-3)


3

FROM TBN GLAND STEAM

GLAND STEAM FAN


(2 X 100%)
22MAW50
AN001

2. VENDOR DWG.
TURBINE SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 1
STEAM - WATER (1/4)
- TT2 - STG - M103 - 00010 - 2
STEAM - WATER (2/4)
- TT2 - STG - M103 - 00010 - 3
STEAM - WATER (3/4)

22MAW60
AN001

22MAM10
BR411 HB1 STG TP40
DN 40

22MAM50
BR401 GB1
DN 25

22LCA31
BR001 GB1
DN 150

ATM

22MAM50
BR501 GB1
DN 200

STG TP44

REFERENCE DRAWINGS

WS

TT2-STG-M103-00010-1 (E-8)

22LCE30
AA001

22LCE43
BR001 GB1
DN 25

STG TP47
TO LP TBN EXHAUST HOOD
SPRAY

TT2-STG-M103-00010-2 (A-1)

22LCE21
BR001 GB1
DN 40

STG TP48
TO START-UP FLASH TANK
SPRAY
10

22LCE22
BR001 GB1
DN 50

TT2-320-M103-00004 (N-6)

TO GSC CONDENSATE SPRAY S

TT2-STG-M103-00010-3 (B-3)

STG TP45
11

TO IP VALVE CHAMBER
PREHEATING SPRAY

TT2-STG-M103-00010-2 (B-2)

STG TP46
TO SEAL WATER SYSTEM

TT2-320-M103-00005 (B-2)

22LCE41
BR001 GB1
DN 15

STG TP41

22LCA30
AA303

22LCA30
AA302

22LCA30
BR001 GB1
DN 250

22LCA30
AA305

TT2-923-M103-00001 (K-6)

FROM CONDENSER HOTWELL


LEVEL TRANSMITTER

HB1

22LCA32
22LCA32
AA001
BR001 GB1
DN 100

TT2-320-M103-00001 (J-4)
(TT2-STG-M103-00010-3) (C-4))

GLAND STEAM CONDENSER


(1 X 100%)
22MAW10
AC001

12

TT2-320-M103-00001 (N-2)

4
22QUC20
TO SAMPLING SYSTEM
BR601 GC2
TT2-162-J103-00001 (E-2)
DN 25
22QUC20 22QUC20
AA601

22LCA20
AA002

22QUC20 22QUC20
AA603 AA604

FOR CONSTRUCTION
4

20.JAN.'15

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

FROM CONDENSER QIT

REV.

DATE

DRWN

CHKD

APPD

TT2-320-M103-00001 (D-6)

EMPLOYER:

AA602

TO SAMPLING SYSTEM
TT2-162-J103-00001 (D-2)

DESCRIPTION

22LCA33
AA001

AA001

22LCA33
AA002

TO CIRCULATING WATER SYSTEM

CONTRACTOR:

TT2-500-M103-00002 (G-3)

FC

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

22LCA33
AA003

DATE

J.H.PARK
K.Y.LEE

P&I DIAGRAM
CONDENSATE SYSTEM (2/3)

DATE
20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.

TITLE:

20.JAN.'15

CHECKED BY

22LCE23
AA006

10

Termotasajero Dos S.A. E.S.P

XV
22LCA33AA061

22LCE41
AA001

22LCW10
BR001 GB1
DN 50 22LCW10

TO CONDENSATE STORAGE TANK

TT2-350-M103-00001 (B-5)

FC

22LCE42
BR001 GB1
DN 40 22LCE42

22LCE23
BR001 GB1
DN 100

22LCA32
AA002

22LCA32
AA003

22LCE21
AA001

22LCE22
AA006

TT2-320-M103-00001 (B-6)
XV
22LCA32AA061

TO CONDENSER

22LCE43
AA001

TT2-320-M103-00003 (E-12)

FROM N2 FILLING CONNECTION

AA001

TO CONDENSER FLASH TANK


SPRAY

TO LP FWH NO.1

TP
22LCA30CT401

DN25

TT2-STG-M103-00010-2 (B-1)

20QJB32
AA001

22LCA30
AA306

22LCA32
AA401

20QJB32
AA002

20QJB32
BR001 GB1
DN 25

TT
22LCA30CT101

22LCA33
AA401

FE
22LCA30CF001

PT
22LCA30CP101

GC2

AA001

TO TURBINE GLAND STEAM


DESUPERHEATER

22LCA30
AA001

TI
-

22LCA33
BR001 GB1
DN 250

TT2-318-M103-00001 (N-1)

FT
22LCA30CF101B

PI
-

22LCA20
BR801 GB1
DN 250

22LCE10
BR001 GB1
DN 50 22LCE10

TO AUX. STEAM SPRAY

22LCA30
AA301

FT
22LCA30CF101A

22MAW40
BR411 HB2
DN 100

TT2-161-W103-00001 (B-2)

22LCA21
BR001 GB1
DN 150

22LCP24
AA001

PP
22LCA30CP401

LO
300 x 250

22LCE30
BR001 GB1
DN 80

TO CHEMICAL FEED SYSTEM

300 x 250

STG TP42

TT2-360-M103-00001 (A-2)

22LCA20
AA001

STG TP39

STG TP38

22MAW10
BR411 HB1
DN 25

22LCP24
BR001 GB1
DN 50

TO CCW HEAD TANK

LO

22LCA20
AA401

TT2-320-M103-00001 (N-11)

22LCA20
BR001 GB1
DN 250

FROM CEP DISCHARGE

TI
22LCA30CT501

22LCA30
AA304

TI
22LCA20CT511

FI
-

22LCA30
AA501

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-320-M103-00002
O

REV.

4
A1(841x594m/m)

DWG.NO

FROM FEEDWATER TANK LEVEL


TRANSMITTER

LEGEND

TT2-320-M103-00003

TT2-314-M103-00001 (I-5)

- LCA : MAIN CONDENSATE PIPING SYSTEM


- LCC : LP FEEDWATER HEATING SYSTEM
- QJB : GAS SUPPLY AND DISRIBUTION SYSTEM N2

LCV
22LCA60AA072
22LCA60
AA003

TT
22LCA60CT111

22LCA60
AA801

TI
-

20QJB53
BR001 HB1
DN 25

TT2-923-M103-00001 (K-7)

PI
22LCA60 22LCA60CP501
AA303
PP
22LCA60CP401
* PSV
22LCC30AA101
T2

22LCA60
AA501
20QJB53 20QJB53
AA005
AA006

LP FEEDWATER HEATER NO.3


(1 X 100%)
22LCC30
AC001

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

TP
22LCA60CT401
TI
22LCA60CT501

22LCA60
AA304

HB1

FROM N2 FILLING CONNECTION

NOTES
22LCA60
AA001

T3
T1

REFERENCE DRAWINGS

1. P&I DIAGRAMS
- TT2-314-M103-00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2-314-M103-00002
FWH VENT AND DRAIN SYSTEM (2/3)
- TT2-320-M103-00002
CONDENSATE SYSTEM (2/3)
- TT2-330-M103-00001
FEED WATER SYSTEM (1/2)
- TT2-923-M103-00001
N2 FILLING SYSTEM

22LCA50
AA801

FL

22LCA60
BR001 GB1
DN 250

22LCA50
BR801 GB1
DN 250

TT2-330-M103-00001 (A-1)

22LCA60
AA402

22LCA60
AA002

22LCC30
BR101 GB1
DN 25

TO DEAERATOR

TI
22LCA50CT502
22LCA50
AA401

TP
22LCA50CT401

22LCA50
AA303

PP
22LCA50CP402

22LCA50
AA304

TT2-314-M103-00002 (N-10)

22LCJ30
BR401 GB1
DN 80

22LCJ30 22LCJ30
AA403
AA404

22LCA50
BR001 GB1
DN 250

FROM LP HEATER DRAIN PUMP

PI
22LCA50CP502

22LCA50
AA002

TI
TT
22LCA50CT112

22LCA50
AA001
22LCA50
AA302

TT2-923-M103-00001 (K-3)
6

20QJB52
BR001 HB1
DN 25

22LCA50
AA501

PI
22LCA50CP513

22LCA50
AA301

20QJB52 20QJB52
AA003
AA004

T2

LP FEEDWATER HEATER NO.2


(1 X 100%)
22LCC20
AC001

PP
22LCA50CP401

T3
T1

TI
22LCA40CT504

22LCA40
AA304

22LCA40
AA401

TP
22LCA40CT401

22LCA40
BR001 GB1
DN 250
22LCA30
BR801 GB1
DN 250

FROM LP FWH NO.1 LEVEL


TRANSMITTER

TI
-

TT
22LCA40CT113
MOV
22LCA40AA041

HB1

FROM N2 FILLING CONNECTION

TT2-923-M103-00001 (K-5)

20QJB51
BR001 HB1
DN 25
22LCA40 22LCA40
AA004

MOV
22LCA30AA841

AA003

T3
T1

PSV
22LCC10AA101

TP
22LCA30CT402

22LCA30
AA401

FROM CONDENSER QIT

FOR CONSTRUCTION

PP
22LCA40CP401

T2

PI
22LCA40CP515

22LCA40
AA301

LP FEEDWATER HEATER NO.1


(1 X 100%)
22LCC10
AC001

10

TI
22LCA40CT505

22LCA40
AA302

22LCA40
AA501

22LCC10
BR101 GB1
DN 25

TT2-314-M103-00002 (N-7)

PI
22LCA40 22LCA40CP514
AA303
PP
22LCA40CP402

22LCA40
AA001

PSV
22LCC20AA101

22LCC20
BR101 GB1
DN 25

FROM N2 FILLING CONNECTION

TI
22LCA50CT503

22LCA40
AA801

HB1

TP
22LCA50CT402

22LCA40
BR801 GB1
DN 250

20.JAN.'15

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

05.FEB.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

EMPLOYER:

TP
22LCA30CT403

TT2-320-M103-00001 (D-6)
22LCA30
AA308

Termotasajero Dos S.A. E.S.P

TI
22LCA30CT506

CONTRACTOR:

PI
22LCA30 22LCA30CP507
AA307
PP
22LCA30CP402

11
PROJECT:

Termotasajero 2 161.6MW CFPP

11

MOV
22LCA30AA041

DATE

J.H.PARK

20.JAN.'15

P&I DIAGRAM
CONDENSATE SYSTEM (3/3)

20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.

TITLE:

DATE

K.Y.LEE

22LCA30
BR001 GB1
DN 250

TT2-320-M103-00002 (N-8)

DRAWN BY
CHECKED BY

FROM GLAND STEAM


CONDENSER
12

DESCRIPTION

10

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-320-M103-00003
O

REV.

5
A1(841x594m/m)

DWG.NO

TT2-320-M103-00004

LEGEND
- LCE : CONDENSATE DESUPERHEATING
SPRAY SYSTEM
- LCM : CLEAN DRAINS SYSTEM
(COLLECTING AND RETURN SYSTEM)

FROM MAIN STEAM LINE

TT2-318-M103-00001 (A-6)

FROM AUX. STEAM HEADER


DRAIN

TT2-318-M103-00001 (N-3)
FROM AUX. STEAM HEADER
DRAIN

TT2-318-M103-00001 (N-5)

FROM AUX. STEAM HEADER


DRAIN

TT2-318-M103-00001 (N-6)
FROM AUX. STEAM HEADER
DRAIN

TT2-313-M103-00001 (N-11)

FROM GLAND SEALING DRAIN


TT2-STG-M103-00010-3 (D-6)

FROM BFP BALANCE LEAK OFF

TT2-330-M103-00001 (B-7)
FROM BFP BALANCE LEAK OFF

TT2-330-M103-00001 (B-6)

FROM BFP BALANCE LEAK OFF

TT2-330-M103-00001 (B-6)
FROM AUX. STEAM HEADER
DRAIN

TT2-318-M103-00001 (J-11)

FROM AUX. STEAM HEADER


DRAIN

TT2-318-M103-00001 (B-12)

22LCM11
BR402 BA1
DN 50

21LCM52
BR401 HB1
DN 25

TT2-314-M103-00003 (G-2)

21LCM54
BR401 HB1
DN 25

TT2-314-M103-00003 (G-5)

PI
22LCM10CP501

STG TP65, 66, 70, 71

22LCM20
BR403 HB2
DN 50

22LCM10
AA303

DN 20
J

22LAB32
BR101 GB1
DN 25

22LCM10
BR001 GA1
DN 250

22LAB12
BR101 GB1
DN 25

22LCM20
BR001 GB1
DN 250

TI
-

TI
22LCM10CT501

22LCE22
AA001

22LCE22
AA002

M1

FO

22LCE22
BR001 GB1
DN 50

22LCE22
AA401

FROM CEP DISCHARGE

TT2-320-M103-00002 (B-10)

A2

START-UP FLASH TANK


(1 X 100%)
22LCM10
BB001

22LCM32
BR401 HB1
DN 50

22LCE22
AA003
6

DN 100

22LCM42
BR401 EB1
DN 25

22LCM10
AA301

22MAL63
BR502 EB2
DN 25

A3

DN 50

22LCM10 *
AA321 22LCM10
AA311

C1

LT
22LCM10CL101

22MAL53
BR502 GB1
DN 25

22LCM10
AA322

LG
22LCM10CL501

MOV
22LCE22AA041

DN 50
SPARE

DN 50

22LCE22
AA004

C2

22LCM20
BR402 HB2
DN 100

10

MOV
20GHA07AA042

TT
22LCM20CT102

TO START-UP FLASH TANK


SUMP

20GHA07
AA004

22LCM20
BR401 HB2
DN 150

TT2-913-M103-00002 (I-9)

20GHA07
AA003

WS
300 x 150

WS

22LCM70
BR001 HB1
DN 300

FOR CONSTRUCTION

TO CONDENSER

TT2-320-M103-00001 (J-4)

WS
22LCM70
AA801

I
SET 90 C

MOV
22LCM70AA041

22LCM70
AA001

22LCM70
BR401 HB1
DN 150

22LCM20
AA401

TT2-320-M103-00001 (B-5)

LCV
22LCM70AA461

22LCM10
AA401

MOV
22LCM20AA441

FROM CONDENSER LEVEL HH

LA-

22LCM10
BR401 HB2
DN 40

TT2-318-M103-00001 (A-3)

DN 150

FROM COLD REHEAT STEAM LINE


DRAIN

TI
-

M2

DN 50

22LCM10
AA313
22LCM10
AA302

11

IN

20GHA07
AA401

FROM SERVICE WATER


DISTRIBUTION SYSTEM

20GHA07
BR001 HB2
DN 100

20GHA07
AA005

20.JAN.'15

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

Termotasajero Dos S.A. E.S.P

TT2-919-M103-00001 (G-3)
CONTRACTOR:

11

20GHA07
AA801

PROJECT:

Termotasajero 2 161.6MW CFPP


DATE

J.H.PARK
K.Y.LEE

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
C

P&I DIAGRAM
CONDNESATE DRAIN SYSTEM

DATE
20.JAN.'15

APPROVED BY

12

TITLE:

20.JAN.'15

CHECKED BY

10

EMPLOYER:

DRAWN BY

XV
22LCE22AA061

DN 25
DN 50

A1

2. VENDOR DWG.
TURBINE SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 3
STEAM - WATER (3/4)

TT
22LCM10CT101

DN 25

22LAB22
BR101 GB1
DN 25

LI
-

FROM HP FWH NO.5 START UP


VENT

SILENCER FOR
START-UP FLASH TANK
22LCM10
BS001

22LCM10
BR451 HB2
DN 25

21LCM53
BR401 HB1
DN 25

22LCM30
BR001 HB1
DN 300
FROM HP FWH NO.6 START UP
VENT

1. P&I DIAGRAMS
- TT2 - 311 - M103 - 00001
MAIN AND REHEAT STEAM SYSTEM (1/3)
- TT2 - 311 - M103 - 00002
MAIN AND REHEAT STEAM SYSTEM (2/3)
- TT2 - 311 - M103 - 00003
MAIN AND REHEAT STEAM SYSTEM (3/3)
- TT2 - 318 - M103 - 00001
AUXILIARY STEAM SYSTEM
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 330 - M103 - 00001
FEED WATER SYSTEM (1/2)
- TT2 - 913 - M103 - 00002
WASTE WATER TRANSFER SYSTEM (2/3)
- TT2 - 919 - M103 - 00001
SERVICE WATER DISTRIBUTION SYSTEM

21LCM51
BR401 HB1
DN 25

22MAL03
BR010 GB1
DN 100

REFERENCE DRAWINGS

22LCE22
BR002 GB1
DN 50

TT2-311-M103-00001 (N-7)

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

22LCM70
AA401

FROM MAIN STEAM LINE DRAIN

NOTES

22LCM21
BR401 DA1
DN 80

DN 400
BR501 HB2
22LCM10

TT2-311-M103-00003 (N-6)

FROM HOT REHEAT STEAM LINE


DRAIN 1

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-320-M103-00004
O

REV.

4
A1(841x594m/m)

NOTES
22LCW11
BR001 HB1
DN 50

HB1

22LCW30
AA001

22LCW21
AA001

22LCW21
AA002

22LCW21
AA003

22LCW30
BR001 HB1
DN 25

DN 15
BR011 HB1
22LCW22

DN 15
BR010 HB1
22LCW22

22LCW20
BR001 HB1
DN 25

22LCW22
AA001

22LCW22
AA002

22LCW22
AA003

22LCW32
AA001

22LCW22
2
BR001 HB1
DN 25
START-UP FLASH TANK DISCHARGE CONTROL STATION
DWG NO. TT2-320-M103-00004(L-10)

22LCW23
AA001

DN 15
BR010 HB1
22LCW33
22LCW23
AA003

22LCW23
AA002

22LCW23
BR001 HB1
DN 25
LP FWH NO.1 TO CONDENSER(EMERGENCY DRAIN)

22LCW33
AA002

DWG NO. TT2-314-M103-00002(J-7)

1. P&I DIAGRAMS
- TT2 - 311 - M103 - 00001
MAIN AND REHEAT STEAM SYSTEM (1/3)
- TT2 - 313 - M103 - 00001
FWH EXTRACTION STEAM SYSTEM (1/2)
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 314 - M103 - 00002
FWH VENT AND DRAIN SYSTEM (2/3)
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM

22LCW41
AA002

22LCW42
AA002

22LCW42
2
BR001 HB1
DN 25
HP FWH NO.5 TO CONDENSER(EMERGENCY DRAIN)
DWG NO. TT2-314-M103-00001(C-10)

22LCW43
AA001

22LCW33
AA003

22LCW33
BR001 HB1
DN 25 CEP MIN FLOW CONTROL STATION

REFERENCE DRAWINGS

22LCW42
AA001

22LCW32
AA002

22LCW33
AA001

22LCW41
2
BR001 HB1
DN 25
HP FWH NO.6 TO CONDENSER(EMERGENCY DRAIN)
DWG NO. TT2-314-M103-00001(C-4)

22LCW32
2
BR001 HB1
DN 25
LP FWH NO.2 TO CONDENSER(EMERGENCY DRAIN)
DWG NO. TT2-314-M103-00002(E-7)

DN 15
BR011 HB1
22LCW23

DN 15
BR010 HB1
22LCW23

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. SEALING WATER TO BE USED FOR VALVES OF
DN65 AND ABOVE
(FOR BELOW DN65, BELLOWS SEALING TYPE VALVE
WILL BE APPLLIED).

22LCW41
AA001

22LCW31
AA002

22LCW31
2
BR001 HB1
DN 25 LP FWH NO.3 TO CONDENSER(EMERGENCY DRAIN)
DWG NO. TT2-314-M103-00002(E-4)

22LCW40
AA001

22LCW31
AA001

22LCW21
BR001 HB1
DN 25 CEP DISCHARGE TO CONDENSER FLASH TANK SPRAY
DWG NO. TT2-320-M103-00001(K-2)
22LCW29
BR001 HB1
DN 25

-LCW : SEALING AND COOLING DRAINS SYSTEM

DN 15
BR010 HB1
22LCW41

GB1

DN 15
BR010 HB1
22LCW42

22LCW29
AA001

22LCW10
AA801

LEGEND

22LCW11
AA003

DN 15
BR010 HB1
22LCW43

22LCW40
BR001 HB1
DN 25

22LCW11
AA301

DN 15
BR011 HB1
22LCW33

AA002

PI
22LCW11CP502

DN 15
BR011 HB1
22LCW21

TT2-320-M103-00002 (B-8)

22LCW10 2
BR001 GB1
DN 50
22LCW10

22LCW10
AA401

FROM CEP DISCHARGE

HB1

PT
22LCW11CP101
22LCW11
AA302

GB1

DN 15
BR010 HB1
22LCW21

TT2-320-M103-00005

PCV
22LCW10AA071

DN 15
BR010 HB1
22LCW31

DWG.NO

PSV
22LCW11AA101

2
1

DN 15
BR010 HB1
22LCW32

22LCW11
BR101 HB1
DN 50

22LCW20
AA001

22LCW43
AA002

22LCW43
BR001 HB1
DN 25
FEED WATER TANK OVERFLOW
DWG NO. TT2-314-M103-00001(M-6)

DWG NO. TT2-320-M103-00002(I-2)

22LCW24
AA003

22LCW34
AA001

22LCW26
AA001

22LCW35
AA001

22LCW26
AA002

22LCW26
2
BR001 HB1
DN 25 CONDENSATE OUTLET TO CEP SUCTION
DWG NO. TT2-320-M103-00001(E-8, H-8)

22LCW44
AA002

22LCW44
BR001 HB1
DN 25
HP EXTRACTION TO HP FWH NO.6
DWG NO. TT2-313-M103-00001 (E-6, E-8)

DN 15
BR010 HB1
22LCW35

DN 15
BR010 HB1
22LCW26

22LCW44
AA001

22LCW34
AA002

22LCW34
BR001 HB1
DN 25
CONDENSER TO VACUUM PUMP
DWG NO. TT2-320-M103-00001 (D-3)

DWG NO. TT2-314-M103-00002(J-8)

DN 15
BR010 HB1
22LCW44

22LCW24
AA002

22LCW24
BR001 HB1
DN 25
LP FWH NO.1 TO CONDENSER(CASCADE DRAIN)

DN 15
BR010 HB1
22LCW45

22LCW24
AA001

DN 15
BR010 HB1
22LCW34

DN 15
BR010 HB1
22LCW24

DN 15
BR011 HB1
22LCW24

22LCW45
AA001

22LCW35
AA234

22LCW45
AA002

22LCW45
BR001 HB1
DN 25
HP EXTRACTION TO HP FWH NO.5
DWG NO. TT2-313-M103-00001 (I-6, I-8)

22LCW35
2
BR001 HB1
DN 25
CONDENSER AIR EXTRACTION LINE TO VACUUM PUMP
DWG NO. TT2-320-M103-00001(D-4)

DN 15
BR010 HB1
22LCW28

10

22LCW28
AA001

BS

DN 15
BR010 HB1
22LCW46

DN 15
BR011 HB1
22LCW36
22LCW36
AA002

22LCW46
AA002

22LCW46
AA001

22LCW36
AA003

22LCW36
BR001 HB1
DN 25
CONDENSER WATER MAKE-UP CONTROL STATION
DWG NO. TT2-350-M103-00001(M-8)

FOR CONSTRUCTION

22LCW46
BR001 HB1
DN 25
HP EXTRACTION TO DEAERATOR
DWG NO. TT2-313-M103-00001 (M-6, M-7)

J.H.PARK C.H.JANG

S.H.KIM

FOR CONSTRUCTION

J.H.PARK C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK C.H.JANG

S.H.KIM

REV.

DATE

DESCRIPTION

CHKD

10

APPD

11
PROJECT:

Termotasajero 2 161.6MW CFPP

TO CONDENSER

SCAH DRAIN TANK TO CONDENSER


DWG NO. TT2-142-M103-00001(C-11)

TT2-320-M103-00001 (B-6)

DRAWN BY

DATE

J.H.PARK

26.MAR.'14

CHECKED BY

(TBN GROUND FLOOR AREA)

DRWN

(TBN OPERATING FLOOR AREA)

(TBN MEZZANINE FLOOR AREA)

DATE

C.H.JANG

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
B

FOR CONSTRUCTION

31.JUL.'13

CONTRACTOR:

22LCW28
AA003

12

26.MAR.'14

Termotasajero Dos S.A. E.S.P

22LCW28
AA002

22LCW29
AA002

EMPLOYER:

22LCW28
BR001 HB1
DN 25
MAIN STEAM LINE START-UP DRAIN
DWG NO. TT2-311-M103-00001 (K-9)

11

22LCW36
AA001

DN 15
BR011 HB1
22LCW28

22LCW27
BR001 HB1
DN 25 COLD REHEAT LINE DRAIN
DWG NO. TT2-311-M103-00002(L-9)

DN 15
BR010 HB1
22LCW36

DN 15

22LCW27 BR011 HB1


AA002 22LCW27

DN 15

22LCW27 BR010 HB1


AA001 22LCW27

26.MAR.'14

APPROVED BY

DATE

S.H.KIM

26.MAR.'14

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
VALVE SEALING WATER SYSTEM
SCALE

JOB NO.

DRAWING NUMBER

TT2-320-M103-00005
O

12
REV.

2
A1(841x594m/m)

DWG.NO

P5A

20QCA21
BR001 GC1
DN 15

TT2-161-W103-00001 (L-10)

GB1

20QCD21
AA001

*
TO START-UP FLASH TANK

TT2-320-M103-00004 (B-5)
7

PIA-

PT
22LAB10CP101

TI
-

TT
22LAB10CT101

*
*

FROM FEEDWATER TANK LEVEL

PI
22LAC10CP505
TI
22LAC10CT505

22LAB10
AA302

22LAB10
AT001

22LAB20
AA301

PDA+
-

PDIT
22LAB20CP102

22LAB20
AA302

22LAB12
BR001 GB1
DN 40

GA+
-

22LAB20
AT001

22LAC10
AA350

MOV
22LAF81AA041

PIA-

PT
22LAB20CP101

TI
-

TT
22LAB20CT101

*
*

22LAF81
AA001
PI
*
22LAC10 22LAC10CP506
AA326

22LAC10
AP001

22LAB20
AA303

PI
22LAC20CP505

MOV
22LAF82AA041

22LAC20
AA350

TI
22LAC20CT505

22LAF82
AA001

22LAC20
AP001

22LAB30
AA301 *
22LAB30
* AA302

PDIT
22LAB30CP102

PIA-

PT
22LAB30CP101

TI
-

TT
22LAB30CT101

*
*

22LAB30
AA303

PI
22LAC30CP505

22LAF90
BR001 EB1
DN 80

MOV
22LAF83AA041

22LAC30
AA350

TI
22LAC30CT505

22LAF83
AA001

22LAB32
BR001 GB1
DN 40

PI
*
*
22LAC10CP507 22LAC10 22LAC10
AA351 AA352
*
TI
22LAC10CT507

22LAC30
AA325

22LAC30
AA326

PI
-

PI
22LAB22CP504

PT
22LAB31CP106

22LAB31 22LAB31
AA304 AA303
MOV
22LAB31AA041

22LAB43
BR010 BB1
DN 150

DN 25
BR401 BB1
22LAB31

22LAB42
BR010 BB1
DN 150

250 x 150

22LAB21
AA401
22LAB21
AA402

MOV
22LAB11AA041

22LAB11
AA401

22LAB11
BR001 BB1
DN 250

TO HP FEEDWATER HEATER
NO.5

J.H.PARK

K.Y.LEE

S.H.KIM

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

10

CONTRACTOR:

TP
22LAB31CT401

11

Termotasajero 2 161.6MW CFPP


22LAB31
BR001 BB1
DN 250

DATE

J.H.PARK

20.JAN.'15

K.Y.LEE

TITLE:

P&I DIAGRAM
FEED WATER SYSTEM (1/2)

DATE
20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
G

DRAWN BY
CHECKED BY

22LAB50
BR001 BB1
DN 350

TT2-330-M103-00002 (N-12)

FOR CONSTRUCTION

15.OCT.'14

PROJECT:

22LAB11
AA402

TP
22LAB11CT401

12

TP
22LAB21CT401

DN 25
BR401 BB1
22LAB11

22LAB21
BR001 BB1
DN 250

PT
22LAB11CP104 22LAB11 22LAB11
AA304 AA303

250 x 150

PI
-

20.JAN.'15

Termotasajero Dos S.A. E.S.P

22LAB41
BR010 BB1
DN 150

150 x 80

11

EMPLOYER:

FOR CONSTRUCTION

22LAB31
AA402

150 x 80

22LAB21 22LAB21
AA304 AA303
MOV
22LAB21AA041

22LAB31
AA401

I
DN 25
BR401 BB1
22LAB21

150 x 80

PT
22LAB21CP105

TT2-311-M103-00002 (B-8)

PI
22LAC30CP506

PI
*
*
22LAC30CP507 22LAC30 22LAC30
AA351
AA352
*
TI
22LAC30CT507

PI
22LAB12CP504

PI
-

TO REHEATER ATTEMPERATOR

PI
*
*
22LAC20CP507 22LAC20
22LAC20
AA351 AA352
*
TI
22LAC20CT507

10

22LAB30
AT001

BOILER FEEDWATER PUMP


(3 X 50%)
22LAC30
AP001

PI
22LAC20 22LAC20CP506
AA326

22LAB22
BR001 GB1
DN 40

22LAB12
AA329

22LAB22
AA329

22LAB32
AA329

PI
22LAB32CP504

GS+
22LAB30AA063

PDA+
-

PSV
22LAB30AA101

TP
22LAB30CT401A

TP
22LAB30CT401B

22LAB10
AA303

TT2-314-M103-00001 (N-5)

PDIT
22LAB10CP102

GS+
22LAB20AA062

PSV
22LAB32AA101

DN 25
BR101 GB1
22LAB32

PDA+
-

GA+
-

PSV
22LAB20AA101

TT2-320-M103-00004 (B-6)

22LAB10
AA301

PSV
22LAB22AA101

DN 25
BR101 GB1
22LAB22

GS+
22LAB10AA061

22LAF81
BR001 EB1
DN 65

TO START-UP FLASH TANK

GA+
-

TP
22LAB20CT401A

TP
22LAB20CT401B

22LAB10
BR101 GB1
DN 80

GB1
20QCD23
AA001

20QCD23
BR001 GC1
DN 15

20QCD22
AA001

2. VENDOR DWG.
BFP SUPPLIER DWG.
- TT2 - BFP - J164 - 00001
LOGIC DIAGRAM PUMP SET
- TT2 - BFP - M103 - 00001
P&I DIAGRAM

20QCA23
AA001

GB1

22LAC10
AA325

DN 25
BR101 GB1
22LAB12

PSV
22LAB10AA101
LO
22LAB10
AA001

TT2-320-M103-00004 (B-6)

TP
22LAB10CT401A

GB1

20QCA23
BR001 GC1
DN 15

20QCA22
AA001

20QCD22
BR001 GC1
DN 15

GB1

TP
22LAB10CT401B

GB1

20QCA22
BR001 GC1
DN 15

DN 250
BR001 GB1
22LAB10

TO START-UP FLASH TANK

FLUSH CONNECTION

DN250

DN250

20QCA21
AA001

PSV
22LAB12AA101

P2C

FLUSH CONNECTION

DN250

150 x 80

P2B

FLUSH CONNECTION

20QCD21
BR001 GC1
DN 15

FROM AMMONIA INJECTION

1. P&I DIAGRAMS
- TT2 - 161 - W103 - 00001
CHEMICAL FEED SYSTEM
- TT2 - 162 - J103 - 00001
SAMPLING SYSTEM
- TT2 - 311 - M103 - 00002
MAIN AND REHEAT STEAM SYSTEM (2/3)
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 320 - M103 - 00003
CONDENSATE SYSTEM (3/3)
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 330 - M103 - 00002
FEED WATER SYSTEM (2/2)
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM

22LAB30
BR101 GB1
DN 80

22QUA10 22QUA10
AA604 AA603

TT2-161-W103-00001 (J-10)

P2A

REFERENCE DRAWINGS

P6C

DN 250
BR001 GB1
22LAB30

AA601

P6B

22LAB43
AA001

LO
22LAB30
AA001

AA602

150 x 80

FEEDWATER STORAGE TANK


(1 X 100%)
22LAA10
BB001

22LAB32
BR001 GB1
DN 40
22LAB22
BR001 GB1
DN 40
22LAB12
BR001 GB1
DN 40

FROM OXYGEN SCAVENGER


INJECTION

22QUA10
BR601 GC2
DN 25
22QUA10 22QUA10

P6A

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. SPOOL PIPE : THIS PART WILL BE REPLACED
WITH CONDENSATE FLOW MEASURING
DEVICE DURING PERFORMANCE TEST.

22LAB42
AA001

BPRV
22LAB43AA002

NOTES

150 x 80

LO

P5C

- LAA : STORAGE, DEAERATION


(INCL. FEEDWATER TANK)
- LAC : FEEDWATER PUMP SYSTEM

22LAB41
AA001

BPRV
22LAB42AA002

250 x 150

P5B

22LAB12 22LAB12
AA001 AA002

*
3

22LAB22 22LAB22
AA001 AA002

RO
22LAB12BP001
22LAB32 22LAB32
AA001 AA002

DEAERATOR
(1 X 100%)
22LAA10
AC001

150 x 80

RO
22LAB22BP001

P1

22LAB32
AA003
*50 x 40 22LAB22 *
AA003 *
*50 x 40 22LAB12
AA003 *
*
50 x 40

RO
22LAB32BP001

22LCP52
AA002

150 x 80

22LCP52
AA001

LEGEND

LO

150 x 80

LO

BPRV
22LAB41AA002

22LCA60
AA302

DN 65
BR001 EB1
22LAF82

PT
22LCA60CP104

GB1

TT2-162-J103-0001 (E-2)

NOTE 2

22LCP52
BR001 HC1
DN 100

TT2-350-M103-00001 (N-11)

TP
22LCA60CT405B

22LAB20
BR101 GB1
DN 80

FROM CONDENSATE
TRANSFER PUMP DISCHARGE

TO SAMPLING SYSTEM

22LAC20
AA325

TT2-320-M103-00003 (E-1)

TP
22LCA60CT405A

22LCA60
AA301

22LCA60
BR001 GB1
DN 250

FROM LP FWH NO.3

TO SAMPLING SYSTEM

DN 250
BR001 GB1
22LAB20

TT2-330-M103-00001

PP
22LCA60CP406

TT2-162-J103-0001 (F-2)

PI
-

DN 65
BR001 EB1
22LAF83

LO
22LAB20
AA001

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-330-M103-00001
O

REV.

4
A1(841x594m/m)

DWG.NO

TT2-330-M103-00002

FI
-

LEGEND
- LAB : FEEDWATER PIPING SYSTEM
- LAD : HP FEEDWATER HEATING SYSTEM
- QUA : SAMPLING SYSTEMS FOR
FEEDWATER SYSTEM

FT
21LAB73CF101A

21LAB73
AA302
21LAB73
AA301

21LAB73
BR001 BB1
DN 150

PP
21LAB73CP401
21LAB73
AA306
21LAB73
AA305

21LAB73
AA304
21LAB73
AA303

***

FE
21LAB73CF001

TP
21LAB73CT401

TO 1ST SUPERHEATER
ATTEMPERATOR

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND
VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. FLOW ELEMENT IS SUPPLIED BY B&W.

TT2-BLR-J-161-00085 (O-23)

NOTE 2
FI
-

21LAB72
BR001 BB1
DN 80

21LAB70
AA306

*
*

21LAB70
21LAB70 AA316
AA302 21LAB70
21LAB70 AA315
AA301

20QJB34
BR001 HB1
DN 25
21LAB70 21LAB70

21LAB70
AA502

TT2-314-M103-00001 (G-5)

HP FEEDWATER HEATER NO.6


(1 X 100%)
22LAD20
AC001

T3

MOV
22LAB60AA841

TP
21LAB70CT411A

TP
21LAB70CT411B

TO STEAM AND WATER SAMPLING


SYSTEM

21LAB70
AA322
21LAB70 21LAB70
AA321 AA001

***

21LAB70
AA002

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00084
BOILER WATER FLOW
- TT2 - BLR - J - 161 - 00085
STEAM FLOW (1/2)

TT2-162-J103-00002 (B-2)

FCV
21LAB70AA061

TO ECONOMIZER
TT2-BLR-J-161-00084 (N-19)

21LAB70
AA307

100%
21LAB70
AA401

FROM N2 FILLING SYSTEM

21LAB70
AA402

TT2-923-M103-00001 (K-3)
DN300

21LAB70
AA405

***

FCV
21LAB70AA861

***

21LAB70
AA003

21LAB70
AA004

35%
21LAB70
AA403
21LAB70
AA404

2
MOV
22LAB60AA042

TT2-162-J103-00002 (B-2)

***

T1

TT2-BLR-J-161-00085 (P-23)

21QUA10 21QUA10
AA603
AA604

PP
21LAB70CP411

DN25

22LAD20
BR101 GB1
DN 25

T2

HP FWH NO.6 LVL HH

TT
21LAB70 21LAB70CT111
AA318
21LAB70
AA317

DN200

PSV
22LAD20AA102

FE
21LAB70CF001

21LAB70
AA308

22LCP51 22LCP51
AA002
AA003

21LAB70
AA501

FT
21LAB70CF101A

AA006

HB1

1. P&I DIAGRAMS
- TT2 - 162 - J103 - 00002
WATER SAMPLING SYSTEM
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 330 - M103 - 00001
FEED WATER SYSTEM (1/2)
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM
- TT2 - 923 - M103 - 00001
N2 FILLING SYSTEM

TO 2ND SUPERHEATER
ATTEMPERATOR

21QUA10 21QUA10
AA601
AA602

TI
-

22LCP51
BR002 BB1
DN 150

AA005

MOV
21LAB70AA041

FT
21LAB70CF101B

21LAB70
AA305

22LAB60
BR801 BB1
DN 350

* *
* *

BC2

PT
21LAB70CP111

*
*

PI
-

21LAB70
BR001 BB1
DN 350

21LAB72
AA306
21LAB72
AA305

TO STEAM AND WATER SAMPLING


SYSTEM

FI
-

FE
21LAB72CF001

REFERENCE DRAWINGS

TP
21LAB72CT401

NOTE 2

21LAB70
AA602
21LAB70
AA601

PP
21LAB72CP401

21LAB72
AA304
21LAB72
AA303

***

21QUA10
BR601 BC2
DN 25

BB1

21LAB71
BR001 BB1
DN 200

FT
21LAB72CF101A

21LAB72
AA302
21LAB72
AA301

22LCP51
AA001

22LCP51
BR001 HC1
DN 150

22LAB60 22LAB60
AA401 AA402

BB1

FROM BOILER INITIAL FILLING

TT2-350-M103-00001 (N-8)

HC1

TP
22LAB60CT412

22LAB60
BR001 BB1
DN 350

TP
22LAB60CT413

22LAB60
AA302

TT
22LAB60CT112
PP
22LAB60CP412

20QJB37
BR001 HB1
DN 25
22LAB60 22LAB60

22LAB60
AA301

22LAB50
BR801 BB1
DN 350

TI
-

AA001

FROM N2 FILLING SYSTEM

TT2-923-M103-00001 (K-8)

AA002

HB1
M

FOR CONSTRUCTION

MOV
22LAB60AA043

22LAB60
AA502

22LAB60
AA501

PSV
22LAD10AA102

HP FWH NO.5 LVL HH

10

TT2-314-M103-00001 (G-5)

22LAD10
BR101 GB1
DN 25

T2

HP FEEDWATER HEATER NO.5


(1 X 100%)
22LAD10
AC001

T3

MOV
22LAB50AA842

T1

22QUA20
BR601 BC2
DN 25

22QUA20 22QUA20
AA601
AA602

TT
22LAB50CT113

TP
22LAB50CT415

PP
22LAB50CP413
22LAB50
AA302
22LAB50
AA301

22LAB50 22LAB50
AA601 AA602

TP
22LAB50CT414

22QUA20 22QUA20
AA603
AA604

15.OCT.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

Termotasajero Dos S.A. E.S.P

TT2-162-J103-00002 (C-2)
CONTRACTOR:

TO SAMPLING SYSTEM
TT2-162-J103-00002 (B-2)

11
PROJECT:

Termotasajero 2 161.6MW CFPP


22LAB50
BR001 BB1
DN 350

FROM BFP DISCHARGE

DRAWN BY

DATE

TT2-330-M103-00001 (B-11)

J.H.PARK

15.OCT.'14

CHECKED BY
K.Y.LEE

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
B

TITLE:

P&I DIAGRAM
FEED WATER SYSTEM (2/2)

DATE
15.OCT.'14

APPROVED BY

10

EMPLOYER:

TO SAMPLING SYSTEM

BC2

TI
-

BB1

11

22LAB50 22LAB50
AA401 AA402

MOV
22LAB50AA041

DATE

S.H.KIM

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-330-M103-00002
O

REV.

2
A1(841x594m/m)

TT2-350-M103-00001

DWG.NO

LEGEND
- LCA : MAIN CONDENSATE PIPING SYSTEM
- LCP : STANDBY CONDENSATE SYSTEM,
INCL. STORAGE AND PUMP SYSTEM
- GHB : DISTRIBUTION SYSTEMS AFTER
TREATMENT

NOTES
LA-

NOTE 2

LI
-

TT2-314-M103-00001 (N-7)
LT
22LCP10CL101

DN 200
BR401 HB1
22LCK10

RO
22LCA32BP001
4

22LCP14
AS001

12GHB11
AS001

CI

N1

N4
N5

22LCP12 22LCP12
AA301
AA302

N9
TI
-

22LCP10
BR401 HB1
DN 200

TT
22LCP10CT101

N10

22LCP10
AA411

RO
22LCP15BP002

N7

22LCP10 22LCP10 22LCP10


CI AA001 AS001
BR001 HC1

22LCP31
AA304

FT
22LCP10CF101
22LCP10
AA303

22LCP10
AA302

22LCP10
BR402 HB1
DN 80

PI
-

TI
-

PT
22LCP10CP101

TT
22LCP10CT102

22LCP10
AA304

22LCP10 22LCP10
AA002 AA003

22LCP13
AA302

TI
22LCP10CT502

22LCP21
AA303

22LCP13
AT001

22LCP21
AA304

DN 100
BR011 HC1
100 x 50
22LCP13

TO CONDENSER

WS

TT2-320-M103-00001 (B-4)

22LCP10
AA005

FL

22LCP13 22LCP13
AA002 AA003

GB1

22LCP53
BR001 HC1
DN 40

WS

DN100 22LCP10
AA006

PI
22LCP21CP502

DN 150
BR001 HC1 150 x 65
22LCP13

WS
22LCP10
AA004

22LCP50
BR001 HC1
DN 100

22LCP13
AA301

PI
22LCP21CP501

TP
22LCP10CT401

NOTE 3

PDA+
PDIS
22LCP13CP202

LCV
22LCP10AA071

22LCP10
BR001 HC1
DN 100

22LCP13
AA001

CHEMICAL FEED SYSTEM

22QUG10
BR601 HC1
DN 25

TT2-161-W103-00001 (B-2)

22LCP53
AA001

TO SAMPLING SYSTEM
TT2-162-J103-00001 (B-2)

22QUG10
AA601

22LCP21
AP001

TO SAMPLING SYSTEM

22LCP51
BR001 HC1
DN 150

TT2-330-M103-00002 (N-8)

DEAERATOR INITIAL FILLING

TT2-330-M103-00001 (A-2)

GB1
22LCP54
BR001 HC1
DN 50
22LCP54 22LCP54
AA001

11

FOR CONSTRUCTION

BOILER INITIAL FILLING

22LCP52
BR001 HC1
DN 100

10

TT2-162-J103-00001 (B-2)

22QUG10
AA602

22LCP54
BR002 GB1
DN 50

20.JAN.'15

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

J.H.PARK

K.Y.LEE

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

DESCRIPTION

Termotasajero Dos S.A. E.S.P

TT2-360-M103-00001 (B-1)
CONTRACTOR:

AA002

CONDENSER VACUUM PUMP


SYSTEM
TT2-CON-E170-00004 (A-1)

22LCP56
BR001 HC1
DN 25

TO CEP SEAL FLUSHING

TT2-320-M103-00001 (B-11)

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

J.H.PARK

20.JAN.'15

CHECKED BY

DATE

K.Y.LEE

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
B

10

EMPLOYER:

CCW HEAD TANK

22LCP55
BR001 HC1
DN 50

22LCP12 22LCP12
AA002 AA003

FE
22LCP10CF001

CONDENSATE TRANSFER PUMPS


(2 X 100%)
22LCP31
AP001

22LCP10
BR001 HC1
DN 150

DN 150

2. VENDOR DWG.
VACUUM PUMP SUPPLIER DWG.
- TT2 - CON - E170 - 00004
VACUUM PUMP P&ID

FI
-

CI

N8

22LCP15
AA001

DN 100
100 x 50 BR011 HC1
22LCP12

N11

CONDENSATE STORAGE TANK


(1 X 100%)
22LCP10
BB001
7

22LCP14
AA001

PI
22LCP31CP502

22LCP31
AA303

22LCP12
AA001

DN 25

PI
22LCP31CP501

DN 150
BR001 HC1 150 x 65
22LCP12

22LCP12
AT001

TI
22LCP10CT501

DN 25

PDIS
22LCP12CP201

CI

22LCP15
AA002

RO
22LCP14BP001

N2

22LCP14
AA002

PDA+
-

DN 50

N3

DN 200
N6

CI

CI

CI

CI

22LCA32
AS001

TT2-320-M103-00002 (N-9)

22LCK10
AS001

22LCA32
BR001 GB1
DN 100

FROM CONDENSER OVERFLOW

1. P&I DIAGRAMS
- TT2 - 161 - W103 - 00001
CHEMICAL FEED SYSTEM
- TT2 - 162 - J103 - 00001
SAMPLING SYSTEM
- TT2 - 314 - M103 - 00001
FWH VENT AND DRAIN SYSTEM (1/3)
- TT2 - 320 - M103 - 00001
CONDENSATE SYSTEM (1/3)
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 330 - M103 - 00001
FEED WATER SYSTEM (1/2)
- TT2 - 330 - M103 - 00002
FEED WATER SYSTEM (2/2)
- TT2 - 360 - M103 - 00001
CLOSED COOLING WATER SYSTEM (1/2)

22LCP14
BR001 HC1
DN 50

22LCK10
AA001

FROM FEED WATER TANK DRAIN

REFERENCE DRAWINGS

12GHB11
BR001 HC1
DN 100

22LCP10
AA401

MOV
12GHB11AA041

DN25

FROM DEMIN. WATER SUPPLY


LINE (FROM OWNER)

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.
2. DEMI WATER FOR TT2 WILL BE BRANCHED OFF
FROM EXISTING FILLING CYCLE PUMP (LLENADO
DE CICLO, 1.33M3/MIN, 60M).
3. SPARE SPOOL PIPE FOR FLOW ELEMENT
IS SUPPLIED.

TT2-320-M103-00001 (B-6)

DN 50
BR001 HC1
22LCP15

FE
12GHB11CF001

FROM CONDENSER HOTWELL


LEVEL TRANSMETER

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
DEMI. WATER TRANSFER SYSTEM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-350-M103-00001
O

REV.

4
A1(841x594m/m)

22LCP24
AA002

DN 100

DN 25

DN 50

*
20PGF10
AA304

H2

20PGF10

E
20PGF10
AA401

20PGF10
AA303

CCW HEAD TANK


(1 X 100%)
20PGF10
BB001

20PGA25
AA002

CHEMICAL INJECTION CYLINDER


(1 X 100%)
20PGX10
DN 25
BB001

350 x 200 20PGA23


AA401

PI
-

TI
-

PT
20PGA24CP101

TT
20PGA24CT101

20PGA24
BR001 HB2
DN 350

20PGA24
AA002

PI
20PGC20CP502

20PGC20*
AA303

450 x 300

20PGB22
AT001

20PGC20
AA304

MOV
20PGA24AA041

DN25

20PGA24
AA001

50 x 20

TI
20PCB21CT503

CLOSED COOLING WATER PUMPS


(2X100%)
20PGC20
AP001

TI
PI
20PCB11CT502
20PCB11CP504
20PCB11
20PCB11
AA501
20PCB11
20PCB11
AA301
AA001
BR001 HB4
MOV
20PGA32AA041

20PCB21
AA307

20PCB21
AA401 CLOSED COOLING WATER

COOLER
(2 X 100%)
20PGD20
AC001

PI
20PCB21CP505

*
20PGF50
BR013 HB2
DN 100

TO CLOSED COOLING WATER


SUPPLY

TT2-360-M103-00002 (C-10)

MOV
IN 20PCB21AA041

20PCB21
BR001 HB4
DN 350

TT
20PGA32CT102

20PGA32
AA001

22PCB11
BR101 HC1
DN 25

DN 350

20PGA24
AA001

350 x 200 20PGA24


AA401

TI
20PGA24CT501

20PGA24
AA306

TI
-

20PGA31
AA301

PSV
20PCB11AA101

*
PI
20PGA24CP503

20PGA31
AA401

PI
20PGA31CP506

20PGA24
AA305

DN 350
BR001 HB2
20PGA24

DN 350
BR001 HB2
20PGA24

PI
20PGC20CP501

PI
20PCB20CP505

DN25

20PGB22
AA302

20PGD10
AC001

TI
20PGF50CT511

FG
20PGF50CF511

PI
20PGA32CP506

150 x 100
20PGF50
AA003

AIR COMPRESSOR
(1 X 100%)

TP4

FOR CONSTRUCTION

PI
20PGA50CP511

150 x 100

20PGA50
AA305
20PGA50
AA003

TP5

20PGB50
BR013 HB2
DN 100

10

20PGA32
AA301

20PGA32
AA401

20PGA33
AA001

20PGC10 20PGA23
AA304
AA001

PDIS
20PGB22CP202

DN 450
BR001 HB2

20PGA50
BR013 HB2
DN 100

20PGA33
BR001 HB2
DN 300

450 x 300

PDA+
-

20PGB22
AA001 20PGB22

20PCB10
20PCB10
AA301
AA001

20PGA31
BR001 HB2
DN 350

TI
20PCB20CT503

HB2
450 x 350

20PGB22
AA301

PI
20PCB10CP504

20PGA32
BR001 HB2
DN 350

20PGC10*
AA303

MOV
20PGA23AA041

20PCB20
AA401

DN25

PI
20PGC10CP502

20PCB20
AA307

DN50

PI
20PGC10CP501

20PGC10
AP001

GS
20PGB22AA001

TI
20PCB10CT502
20PCB10
AA501

DN50

20PGB21
AA302

20PGB21
AT001

GI+
-

MOV
20PGA31AA041

HC1

20PGA25
AA501

50 x 20

HB4

20PGB21
AA301

DN25

PDIS
20PGB21CP201

DN 450
BR001 HB2
20PGB21
AA001 20PGB21

MOV
20PCB20AA041
IN

DN 350
BR001 HB2
20PGA25

TT2-500-M103-00002 (L-12)

PDA+
-

GS
20PGB21AA001

20PGA25
AA306

TI
20PGA25CT501

DN50

PI
20PGA25CP503

HC1

DN 25

FROM CWP DISCHARGE

22PCB10
BR101 HC1
DN 25

HB4

20PGC61
BR001 HB2
DN 25

20PCB10
BR001 HB4
DN 350

PSV
20PCB10AA101

20PGC61
AA001

GI+
-

LT
20PGF10CL101B

DN25

DN 50

DN25

D A

B F

20PGX10
AA401

DN 25
BR001 HC1
20PGC62

20PGC62
AA001

H1

DN50

SPARE

20PGX10
AA501

AA502

DN 25

DN 50

DN 25

1. P&I DIAGRAMS
- TT2 - 320 - M103 - 00002
CONDENSATE SYSTEM (2/3)
- TT2 - 350 - M103 - 00001
DEMI. WATER TRANSFER SYSTEM
- TT2 - 360 - M103 - 00002
CLOSED COOLING WATER SYSTEM (2/2)
- TT2 - 500 - M103 - 00002
CIRCULATING WATER SYSTEM (2/2)

DN 100

LI
-

20PGF10
AA302

20PGF10
BR401 HB2
DN 100

DN 100
BR001 HB2
20PGC10

*
20PGX10

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND VENT
POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.

LG
20PGF10CL501

DN 25

* AA301

*
C2

20PGF10
BR402 HB2
DN 25

REFERENCE DRAWINGS

K C1

SPARE

LT
20PGF10CL101A

PT
20PGB20CP101

20PGC10
AA401

LI
-

DN 100
B

PI
-

- GHB : DISTRIBUTION SYSTEMS AFTER


TREATMENT
- PGA : CLOSED COOLING WATER PIPING SYSTEM (FORWARD)
- PGB : CLOSED COOLING WATER PIPING SYSTEM (RETURN)
- PGF : PRESSURE SYSTEM
- PGC : CLOSED COOLING WATER PUMP SYSTEM
- PGD : COOLER

20PGA23
BR001 HB2
DN 350

TT2-360-M103-00001

22LCP24
AA401

22LCP24
BR451 GB1
DN 25
22LCP24
AA004

HC1

XV
22LCP24AA041
22LCP24
AA003

22LCP24
BR001 GB1
DN 50

RO
22LCP24BP001

TT2-320-M103-00002 (B-8)

LEGEND

22LCP54
BR001 GB1
DN 50

TT2-350-M103-00001 (N-11)
FROM CEP DISCHARGE

DWG.NO

FROM CONDENSATE TRANSFER


PUMP
1

TO CLOSED COOLING WATER


RETURN

TT2-360-M103-00002 (N-10)

20.JAN.'15

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P

20PGB50
AA003

TO CONDENSER CW PIPE
DISCHARGE

20PCB20
BR001 HB4
DN 350

11

CONTRACTOR:

TT2-500-M103-00002 (G-2)

11
PROJECT:

FROM CLOSED COOLING


WATER RETURN

20PGB20
BR001 HB2
DN 350

TT2-360-M103-00002 (M-10)

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

Y.M.KIM

20.JAN.'15

CHECKED BY

DATE

C.H.JANG

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
CLOSED COOLING WATER SYSTEM
(1/2)

SCALE

JOB NO.

DRAWING NUMBER

TT2-360-M103-00001
O

12
REV.

4
A1(841x594m/m)

UG
AG

20PGA41
AA312

20PGA41
AA302

PI
20PGA42CP502

20PGA42
BR001 HB2
DN 25

20PGA41
BR003 HD2
DN 25

20PGA42
AA001

20PGA32
BR001 HB2
DN 100

PI
20PGA44CP504

20PGA44
BR001 HB2
DN 80

UG
AG

20PGA72
BR001 HB2
DN 25

20PGA44
AA001

20PGA45
BR001 HB2
DN 25

UG
AG

20PGA32
BR001 HB2
DN 100

20PGA71
BR001 HD2
DN 25

20PGA45
AA001

20PGA46
BR001 HB2
DN 25

20PGA46
AA001

20PGA43
BR001 HB2
DN 25

20PGA43
AA001

20PGA71
BR001 HD2 150 x 100
DN 150

PI
20PGA46CP506
20PGA46
AA301

20PGA51
AA001

20PGA53
AA005

20PGA55
AA006

DN25

20PGA42
BR011 HB2
DN 25
20PGA42
BR012 HB2
DN 25

20PGA51
BR011 HB2
DN 80

20PGA52
BR011 HB2
DN 80

20PGA53
BR051 HB2
DN 50

20PGA55
BR061 HB2
DN 40

DN25
DN25
DN25
DN25

TT2-360-M103-00001 (N-7)

LO
20PGA63
AA003

20PGA63
BR001 HB2
DN 25

20PGA60
BR002 HB2
DN 200

DN25

FD FAN B BEARING
(2X50%)

DN25

DN25

DN25

PULVERIZER D GEAR BOX LUBE UNIT


(1X100%)
AH GUIDE BEARING
(1 X 100%)

***

PI
20PGA55CP513
20PGA55
AA303

SCAH DRAIN TRANSFER PUMP


(1 X 100%)

20PGA43
BR011 HB2
DN 25
20PGA43
BR012 HB2
DN 25

DN25
DN25
DN25
DN25

20PGA52
BR022 HB2
DN 50
20PGA52

PA FAN A BEARING
(2X50%)

DN25

PA FAN B BEARING
(2X50%)

DN25
DN25

FGD AIR COMPRESSOR


(3 X 33%)

SAMPLE COOLER

50 x 40

BFP COOLER
(3 X 50%)

FG
20PGB51CF507

50 x 25

LP HDP
(2 X 100%)

40 x 20

20PGB52
BR022 HB2
DN 50

40 x 25

CEP THRUST MOTOR BEARING


(2 X 100%)

20PGB52
BR023 HB2
DN 50

FG
20PGB53CF501

20PGA60
AA302

SEE TBN P&ID


S
TT2-STG-M103-00010-2

20PGA61
BR001 HB2
DN 100
20PGA61
BR002 HB2
DN 100
20PGA61
BR003 HB2
DN 100
20PGA61
BR004 HB2
DN 100

DN40

FG
20PGB63CF516

DN 100

LO

LO
20PGA61
AA003
LO
20PGA61
AA004
LO

20PGA62
AA001

20PGA62
BR001 HB2
DN 150

STG TP58
TURBINE LUBRICATION
OIL COOLER

20PGB61
4 BR012 HB2
DN 100
LO
20PGB61 20PGB61
AA003 BR013 HB2
DN 100
LO
20PGB61
20PGB61 4
AA004
BR014 HB2
DN 100
LO

20PGB62
AA001

20PGB62
AA002

20PGA62
AA002

20PGB44
AA001

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00089
HOWDEN TRI - SECTOR AIR HEATER
- TT2 - BLR - J - 161 - 00091
FAN BEARING MONITORING
- TT2 - BLR - J - 161 - 00093
PULVERIZER INERTING & CLEARING
STG SUPPLIER DWG.
- TT2 - STG - M103 - 00010 - 2
STEAM - WATER (2/4)

UG
AG

AG
UG

20PGB45
AA001

20PGB46
AA001

150 x 25

20PGB43
AA001

150 x 100

20PGB71
BR001 HD2
DN 150

20PGB50
BR001 HB2
DN 150

350 x 200

20PGB51
AA001
7

20PGB52
AA002

20PGB53
AA005

20PGB55
AA006

20PGB20
BR001 HB2
DN 350

LO

TO CCW PUMP

TT2-360-M103-00001 (N-12)

20PGB63
AA003

20PGB50
BR013 HB2
DN 100

TI
20PGB60CT514

20PGB60
BR002 HB2
DN 200

20PGB20
AA001

FROM AIR COMPRESSOR CCW


RETURN

TT2-360-M103-00001 (K-11)

20PGB60
AA005

FOR CONSTRUCTION
4

20.JAN.'15

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

FG
20PGB60CF515

20PGB62
BR001 HB2
DN 150

TI
20PGB60CT515

20PGB60
BR003 HB2
DN 200

DN 150
BR002 HB2
20PGB62

PROJECT:

Termotasajero 2 161.6MW CFPP


20PGB60
AA006

20PGB31
AA401

DRAWN BY

DATE

Y.M.KIM

20.JAN.'15

CHECKED BY

DATE

C.H.JANG

20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
B

CHKD

10

EMPLOYER:

12

LO
LO

LO
LO

DN 150
BR002 HB2
20PGA62

FG
20PGB60CF514

20PGB61
AA002

20PGA60
AA301

20PGB63
BR001 HB2
DN 25

20PGA61
AA002

1. P&I DIAGRAMS

TI
20PGB63CT516

20PGB61 20PGB61
AA001 BR011 HB2

LO

REFERENCE DRAWINGS
20PGB42
AA001

TURBINE GENERATOR
COOLER

20PGA61
AA001

TI
20PGB55CT513

20PGB55
BR061 HB2
DN 40

DN40

TI
20PGB53CT501

20PGB53
BR051 HB2
DN 50
FG
20PGB55CF513

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.

TI
20PGB52CT510

20PGB52
BR021 HB2
DN 80

TURBINE EHC COOLER

20PGA63
AA301

PI
20PGA60CP515

20PGA31
AA402

FG
20PGB52CF510

40 x 20

TI
20PGB51CT507

20PGB51
BR011 HB2
DN 80

20PGB53
BR052 HB2
DN 40
DN 40
BR053 HB2
20PGB53

40 x 25

50 x 25

20PGB51
BR011 HB2
DN 80

20PGB52
BR024 HB2
DN 50

20PGB43
BR001 HB2
DN 25

NOTES

TI
20PGB43CT503

20PGB54
BR041 HB2
DN 100

BR023 HB2
20PGA52 DN 50
BR024 HB2
DN 50
50 x 40
20PGA53
BR052 HB2
DN 50
DN 50
BR053 HB2
20PGA53

FG
20PGB43CF503

TI
20PGB46CT506

20PGB46
BR001 HD2
DN 25

20PGB43
BR011 HB2
DN 25
20PGB43
BR012 HB2
DN 25

DN25

80 x 50

FG
20PGB46CF506

- PGA : CLOSED COOLING WATER PIPING SYSTEM


(FORWARD)
- PGB : CLOSED COOLING WATER PIPING SYSTEM
(RETURN)
- PGD : COOLER

TI
20PGB45CT505

20PGB45
BR001 HB2
DN 25

20PGB45
AS001

11

20PGA60
BR003 HB2
DN 200

FG
20PGB45CF505

20PGB41
AA012

TI
20PGB44CT504

20PGB44
BR001 HB2
DN 80

20PGB46
BR011 HB2
DN 25
DN 25
BR012 HB2
20PGB46

80 x 50

PI
20PGA53CP501
20PGA53
AA306

FG
20PGB44CF504

20PGB41
AA011

TI
20PGB42CT502

20PGB42
BR001 HB2
DN 25

***

20PGA45
AS001

20PGA46
BR011 HB2
DN 25
DN 25
BR012 HB2
20PGA46

20PGA51
AA301

PI
20PGA52CP510
20PGA52
AA302

FG
20PGB42CF502

20PGB44
BR011 HB2
DN 65
20PGB44
BR012 HB2
DN 65
20PGB44
BR013 HB2
DN 65
20PGB44
BR014 HB2
DN 65

LEGEND

TI
20PGB41CT511

20PGB41
BR001 HB2
DN 25
DN 25
BR002 HB2
20PGB41

20PGB42
BR011 HB2
DN 25
20PGB42
BR012 HB2
DN 25

PULVERIZER C GEAR BOX LUBE UNIT


(1X100%)

PI
20PGA60CP514

10

FD FAN A BEARING
(2X50%)

PULVERIZER B GEAR BOX LUBE UNIT


(1X100%)

PI
20PGA63CP516

20PGA32
BR001 HB2
DN 350

DN25
DN25

PULVERIZER A GEAR BOX LUBE UNIT


(1X100%)

20PGA44
BR011 HB2
DN 65
20PGA44
BR012 HB2
DN 65
20PGA44
BR013 HB2
DN 65
20PGA44
BR014 HB2
DN 65

FROM CCW COOLER

DN25

ID FAN B BEARING
(2X50%)

DN25

PI
20PGA51CP507

20PGA52
AA002

20PGA43
AA301

DN25

20PGB41
BR011 HB2
DN 25
20PGB41
BR012 HB2
DN 25

DN25

TI
20PGB41CT512

FG
20PGB41CF511

ID FAN A BEARING
(2X50%)

DN25

20PGA54
BR041 HB2
DN 100

UG
AG

350 x 200

20PGA50
BR001 HB2
DN 150
AG
UG

200 x 100

20PGA41
BR011 HB2
DN 25
20PGA41
BR012 HB2
DN 25

20PGA45
AA301

PI
20PGA43CP503

150 x 25

20PGA44
AA301

PI
20PGA45CP505

AG
UG

20PGA42
AA301

20PGA41
AA301

20PGB31
BR001 HB2
DN 200

20PGA41
BR001 HB2
DN 25
DN 25
BR002 HB2
20PGA41

FG
20PGB41512

UG
AG

20PGA41
AA311

20PGB41
BR003 HD2
DN 25

UG
AG

PI
20PGA41CP511

SEE BOILER P&ID


TT2-BLR-J-161-00089 S
TT2-BLR-J-161-00091
TT2-BLR-J-161-00093

20PGB72
BR001 HB2
DN 25

TT2-360-M103-00002
1

20PGB71
BR001 HD2
DN 25

DWG.NO

PI
20PGA41CP512

AG
UG

AG
UG

20PGB73
BR001 HD2
DN 25

AG
UG

AG
UG

22MKJ30
BR410
DN 25

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
CLOSED COOLING WATER SYSTEM
(2/2)

SCALE

JOB NO.

DRAWING NUMBER

TT2-360-M103-00002
O

12
REV.

4
A1(841x594m/m)

DWG.NO

TT2-500-M103-00001

COOLING TOWER
( 6CELLS )

LEGEND
- PAR : MAKE-UP WATER PIPING SYSTEM
- PAB : CIRCULATING (MAIN COOLING) WATER PIPING AND CULVERT SYSTEM
- PAC : CIRCULATING (MAIN COOLING)
WATER PUMP SYSTEM
- PCB : AUXILIARY COOLING WATER PIPING AND CULVERT SYSTEM
- PCC : PUMP SYSTEM

22PAE10
AC001

22PAE20
AC002

22PAE30
AC003

22PAE40
AC004

22PAE50
AC005

22PAE60
AC006

BR001 HB4
DN 750

UG

25 x 15

FROM CHEMICAL FEED


SYSTEM

25 x 15

20QCB10
BR001 HG1
DN 25

1. P&I DIAGRAMS
- TT2 - 500 - M103 - 00002
CIRCULATING WATER SYSTEM (2/2)
- TT2 - 500 - M103 - 00003
COOLING TOWER MAKEUP SYSTEM

FROM CHEMICAL FEED


SYSTEM
TT2-CFS-R103-00001 (D-12)

25 x 15

FROM CONDENSER

TT2-500-M103-00002 (L-3)
FROM COOLING TOWER MAKE
UP SYSTEM

22PAR10
BR001 HB2
DN 350

22PAR10
AA001

TT2-919-M103-00002 (B-11)

COOLING TOWER BASIN

2. VENDOR DWG.
AHS SUPPLIER DWG.
- TT2 - AHS - M103 - 00007
BOTTOM ASH HANDLING SYSTEM
CWP SUPPLIER DWG.
- TT2 - CWP - J103 - 00001
P&ID OF CWP, AUX. CWP
- TT2 - CWP - J103 - 00001
COOLING TOWER SUPPLIER DWG.
- TT2 - CTW - P103 - 00001
COOLING TOWER P&ID
WASTE WATER TREATMENT SUPPLIER DWG.
- TT2 - WWS - R103 - 00002
P&I DIAGRAM
CHEMICAL FEED SYSTEM SUPPLIER DWG.
- TT2 - CFS - R103 - 00001
P&ID OF CW CHEMICAL FEED SYSTEM

HB4

22PAB60
BR002 HB5
DN 1850

UG

REFERENCE DRAWINGS

TT2-CFS-R103-00001 (J-12)

MOV
22PAB70AA046

HB4

HB4
UG

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

TT2-CFS-R103-00001 (L-12)

20QCH20
BR001 HG1
DN 25

22PAB70 22PAB70
AS001

BR002 HB4
DN 750

MOV
22PAB70AA045

MOV
22PAB70AA044

UG

22PAB70
22PAB70
AS002

BR003 HB4
DN 750

22PAB70
22PAB70
AS003

BR004 HB4
DN 750

UG

HB4

HB4

MOV
22PAB70AA043

UG

MOV
22PAB70AA042

HB4

MOV
22PAB70AA041

22PAB70
22PAB70
AS004

BR005 HB4
DN 750

22PAB70
AS005 22PAB70

22PAB70
22PAB70
AS006

BR006 HB4
DN 750

TO COOLING TOWER MAKE UP


RECIRCULATION LINE

TT2-919-M103-00002 (B-11)

NOTES

FROM CHEMICAL FEED


SYSTEM

20QCH30
BR001 HG1
DN 25

LI
-

TI
-

LT
22PAC10CL101

PI
22PAC10CP501

22PAC10
AA301

MOV
22PAB11AA041

PT
22PAB11CP101

TT
22PAB11CT102

1350 x 1100

IN

22PAB11
AS001

HB5

XV
22PAB11AA001

22PAC10
AP001

22PAB11
AA302

22PAB11
BR001
DN 1350

AG

PI
-

PI
-

22PAC20
AA301

1350 x 1100

IN

22PAB21
AS001

22PAB40
BR001 HB5
DN 1850

PI
-

CIRCULATING WATER PUMP

*
9

22PCC10
AA301

AUX. COOLING WATER PUMP

MOV
22PAB31AA041

22PAB31
AS001

22PCC10
AP001

22PAB31
AA302

22PAB31
BR001 HB4
DN 250

22PAB31
AA001

10
M

MOV
20PCB31AA041

11
M

FOR CONSTRUCTION

HEAT EXCHANGER
(1 X 100%)

20PCB31
AA302

150 x 80

20PCB31
BR001 HC1
DN 150

MOV
20PCB32AA041

PT
22PCB32CP102
20PCB32
AA302

150 x 80

20PCB31
BR003 HC1
DN 150

20PCB31
BR002 HD2
DN 150

PI
-

20PCB32 20PCB32
AA001
AS001

(2 X 100%)

PT
22PCB31CP101
M

PI
22PCB32CP502
20PCB32
AA301

SEE ASH P&ID


TT2-AHS-M103-00007 (C-7)
HB4

20PCB31 20PCB31
AA001
AS001

20QHE10
AP001

350 x 250

20PCB31
AA001

20PCB33*
AA001

20PCB33
BR001 HC1
DN 150

20PCB33
BR002 HD2
DN 150

20PCB33
BR003 HC1
DN 150

TO COOLING WATER RECYCLING

20.JAN.'15

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

EMPLOYER:

Termotasajero Dos S.A. E.S.P

TT2-WWS-R103-00002 (B-7)

11
PROJECT:

Termotasajero 2 161.6MW CFPP

20QHE20
AP001

DRAWN BY

DATE

Y.M.KIM

20.JAN.'15

CHECKED BY

20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

C.H.JANG

SCREEN

12

CHKD

10

CONTRACTOR:

20PCB32
BR001 HC1
DN 150

UG

IN

PI
PI
22PCB31CP501
20PCB31
AA301

TT2-500-M103-00002 (L-11)

PT
22PAB31CP103

150 x 125

PI
22PCC10CP501

UG

TO CONDENSER

AG

(2 X 50%)

C/T BLOWDOWN PUMP

HB4

XV
22PAB21AA001

22PAC20
AP001

(1 X 100%)

22PAB21
AA302

22PAB21
BR001 HB4
DN 1350

AG

LT
22PAC20CL102

PT
22PAB21CP102

MOV
22PAB21AA041

150 x 125

PI
22PAC20CP501

AG

AG

LI
-

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
CIRCULATING WATER SYSTEM (1/2)

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-500-M103-00001
O

REV.

4
A1(841x594m/m)

DWG.NO

TT2-CON-E170-00004 (A-10)

FG
20PCB40CF501

C 20PCB41
BR001 HC1
DN 150 DN 150
BR001 HC1
20PCB42

TI
20PCB40CT501
20PCB40 20PCB40
AA001 BR001 HC1

RO
22LCA33BP001

22LCA33
BR001 GB1
DN 250

TT2-320-M103-00002 (N-11)

22PAB60
BR002 HB5
DN 1850

UG

22LCA33
BR002 HB5
DN 350

350 x 250

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.

AG

1. P&I DIAGRAMS
- TT2 - 360 - M103 - 00001
CLOSED COOLING WATER SYSTEM (1/2)
- TT2 - 500 - M103 - 00001
CIRCULATING WATER SYSTEM (1/2)

22PAB60
TO COOLING TOWER
BR002 HB5
TT2-500-M103-00001 (N-4)
DN 1850

DN100

22MAG10
AA304

LG
22MAG10CL512

*
22MAG10
AA303

22MAG10
AA308

22MAG10
AA307

*
DN50

22MAG10
AA412

22MAG10
AA301

LSH
22MAG10CL202

22MAG10
AA501

22MAG10
AA306

22MAG10
AA302

LG
22MAG10CL511

LSH
22MAG10CL201

TI
-

22PAB52
BR001 HB4
DN 1350

LA+
-

22MAG10
AA305

TT
22PAB52CT112

LA+
-

*
*

TI
-

* DN50

22PAB51
BR001 HB4
DN 1350

TI
22PAB52CT512

22MAG10
AA502

TT
22PAB51CT111

HB4

HB4

TI
22PAB51CT511

25B

25D
31B

24A

31A

31C

2. VENDOR DWG.
VACUUM PUMP SUPPLIER DWG.
- TT2 - CON - E170 - 00004

REFERENCE DRAWINGS

NOTES

AG

MOV
22PAB52AA041

HB5

MOV
22PAB51AA041

HB5

UG

FROM GSC DISCHARGE

20PCB20
BR001 HB4
DN 350

HB5

- MAG : CONDENSING SYSTEM


- PAB : CIRCULATING (MAIN COOLING) WATER PIPING AND
CULVERT SYSTEM
- PAR : MAKE-UP WATER PIPING SYSTEM
- PCB : AUXILIARY COOLING WATER PIPING AND CULVERT SYSTEM

DN 150

FROM CLOSED COOLING WATER


COOLER

TT2-360-M103-00001 (N-11)

LEGEND

21PCB20
BR001 HB5
DN 350

TT2-500-M103-00002

SEE VACUUM PUMP SUPPLIER DWG.

24B

DN100

22MAG10
AA414

31D

LG
22MAG10CL513

TP
22PAB51CT411A

22PAB52
AS001

22PAB42
AS001

*
*

TP
22PAB52CT412C

TP
22PAB41CT413

TP
22PAB42CT414

TI
22PAB41CT513

TI
22PAB42CT514

TT
22PAB41CT113

TT
22PAB42CT114

22PAB42
AA301

FOR CONSTRUCTION

HB5

MOV
22PAB42AA041

HB5

22PAB40
BR003 HB5
DN 1850

AG

22PAB40
BR002 HB5
DN 1850

3
11

350 x 150

HB4
HC1
C

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P

TT2-500-M103-00001 (N-10)

11

PI
20PCB30CP501
20PCB30
AA301

20PCB30
BR001 HC1
DN 150
20PCB30
AA001

CONTRACTOR:

UG
AG

12

FROM CWP DISCHARGE

21PCB10
BR001 HB5
DN 150

MOV
22PAB41AA041

LOCAL SAMPLE

HB4

HB4
M

10

TI
-

PI
22PAB42CP513

22PAB42
BR001 HB4
DN 1350

22PAB41
BR001 HB4
DN 1350

22PAB41
AA301

TI
-

PI
22PAB41CP512

PI
22PAB52CP514

22PAB52
AA401

22PAB51
AA401

22PAB52
AA301

LOCAL SAMPLE

LG
22MAG10CL514

TP
22PAB52CT412B

TP
22PAB51CT411C 22PAB51
AA301
PI
22PAB51CP511

AA504

TP
22PAB52CT412A

TP
22PAB51CT411B
8

*
30D 22MAG10

DN50

24D

2B 30C

22PAB41
AS001

25C

DN100

22PAB51
AS001

1B

1A

22MAG10
AA413

25A

30B 2A

24C

22MAG10 30A
AA503

22MAG10
AA411

DN100

DN50

CONDENSER
(1 X 100%)
22MAG10
AC001

20PCB10
BR001 HB4
DN 350

TO CLOSED COOLING WATER


COOLER

PROJECT:

Termotasajero 2 161.6MW CFPP

TT2-360-M103-00001 (N-5)

S C
20PCB34
SEE VACUUM PUMP SUPPLIER DWG.
BR001 HC1
DN 150 DN 150
TT2-CON-E170-00004 (A-10)
BR001 HC1
THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.
20PCB35
ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
J

DRAWN BY

DATE

Y.M.KIM

15.OCT.'14

CHECKED BY

DATE

C.H.JANG

15.OCT.'14

APPROVED BY

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
CIRCULATING WATER SYSTEM (2/2)

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-500-M103-00002
O

REV.

3
A1(841x594m/m)

TT2-913-M103-00001

DWG.NO

LEGEND
-GMB : DRAINAGE SYSTEM FOR OILY DRAINS.

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND VENT
POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.
2

REFERENCE DRAWINGS
1. P&I DIAGRAMS
TT2-913-W103-00001
WASTE WATER TREATMENT SYSTEM (1/2)
HD2

20GMB40
BR001 HB2
DN 80

20GMB41
BR001 HD2
DN 80

TO OILY WASTEWATER POND


TT2-913-W103-00001 (B-2)

AG
UG

20GMB33
BR001 HB2
DN 65
20GMB31
AA002

20GMB32
AA002

20GMB31
AA001

20GMB32
AA001

FROM UNIT MAIN


TRANSFORMER DRAIN

LUBEOIL CLEAN / DIRTY


STORAGE TANK AREA

PI
20GMB31CP501

*
*

3
*

*
*

3
*

PI
20GMB32CP501
20GMB32
AA301

LA++, +, 20GMB31CL201

FROM TBN FLOOR DRAIN

FROM TBN FLOOR DRAIN


DRAIN

DRAIN

AG
UG

AG
UG

AG
UG

FROM UNIT AUX.


TRANSFORMER DRAIN

20GMB22
AA301

*
*

LA++
-

PI
20GMB22CP501

3
*

*
*

3
*

PI
20GMB21CP501

50 x 32

LA++, +, 20GMB21CL201

20GMB21
AA301

LA++
-

50 x 32

C
S

AG
UG

PI
20GMB12CP501

*
*

*
*

PI
20GMB11CP501

LA++, +, 20GMB11CL201

20GMB12
AA301

20GMB11
AA301

LA++
-

50 x 32

20GMB31
AA301

20GMB32
BR001 HB2
DN 50

20GMB22
AA002
20GMB22
AA001

50 x 32

20GMB21
AA002

20GMB12 20GMB12
AA001
BR001 HB2
DN 50

UG
AG

20GMB12
AA002 65 x 50

20GMB11 20GMB11
20GMB11
AA001
AA002 65 x 50
BR001 HB2
DN 50

UG
AG

20GMB21
AA001

20GMB22
BR001 HB2
DN 50

20GMB21
BR001 HB2
DN 50

20GMB31
BR001 HB2
DN 50

20GMB23
BR001 HB2
DN 65

20GMB14
BR001 HD2
DN 65

UG
AG

FOR CONSTRUCTION
20GMB11
AP001

20GMB12
AP001

20GMB21
AP001

TRANSFORMER AREA SUMP PUMP

20GMB31
AP001

ST BUILDING BFP AREA SUMP PUMP

20GMB32
AP001

ST BUILDING CONDENSER AREA SUMP PUMP

(2 x 100%)

(2 x 100%)

10

20GMB22
AP001

(2 x 100%)

20.JAN.'15

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

22.APR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

Y.M.KIM

20.JAN.'15

DATE

CHECKED BY
C.H.JANG

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

20.JAN.'15

APPROVED BY

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
WASTE WATER TRANSFER SYSTEM
(1/3)

SCALE

JOB NO.

DRAWING NUMBER

TT2-913-M103-00001
O

12
REV.

3
A1(841x594m/m)

DWG.NO

TT2-913-M103-00002

LEGEND
-GMD : DRAINAGE SYSTEM FOR CHEMICAL DRAINS.

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND VENT
POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.
2. THE FLANGE FOR VENT WILL BE PROVIDED BY SUMP
PUMP SUPPLIER. BUT, THE VENT PIPE WILL BE PROVIDED
BY CONTRACTOR.

REFERENCE DRAWINGS
1. P&I DIAGRAMS
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 913 - M103 - 00001
WASTE WATER TREATMENT SYSTEM (1/2)
- TT2 - 919 - M103 - 00001
SERVICE WATER DISTRIBUTION SYSTEM
- TT2 - 142 - M103 - 00001
BLOWDOWN SYSTEM

4
20GMD23
BR003 HD2
DN 50

20GMD33
BR002 HD2
DN 100

AG
UG

AG
UG

4
TO WASTE WATER LIFT STATION

TI
-

TI
-

TT
20GMD31CT101

MOV
20GHA09AA441

20GHA09
BR002 HB2
DN 50

MOV
20GHA07AA441

FROM SERVICE WATER SUPPLY


SYSTEM

TT2-919-M103-00001 (M-11)

FROM SERVICE WATER SUPPLY


SYSTEM

20GHA07
BR002 HB2
DN 50

20LCM20
BR411 HB2
DN 150

TT2-919-M103-00001 (M-9)

TT
20GMD21CT101

20GMD22
AA001

20GMD22
BR001 HC1
DN 80

*
*

PI
20GMD22CP501

*
*

NOTE 2

NOTE 2

LA++, +, 20GMD21CL201

LA++
-

PI
20GMD21CP501

*
*

20GMD21
AA301

PI
20GMD32CP502

I
20GMD21
BR001 HC1
DN 80

20GMD32
BR001 HC1
DN 80

20GMD32
AA301

LA++, +, 20GMD31CL202

20GMD31
AA301

PI
20GMD31CP502

*
*

2. VENDOR DWG.
- BOILER SUPPLIER DRAWING
TT2 - BLR - J - 161 - 00089
[TRI SECTOR AIR HEATER]

20GMD22
AA301

I
20GMD31
BR001 HC1
DN 80

LA++
-

20GMD21
AA001

20GMD32
AA001

TT2-913-W103-00001 (D-10)

20GMD22
AA002

20GMD21
AA002

20GMD32
AA002

20GMD31
AA002
20GMD31
AA001

TO WASTE WATER LIFT STATION

20GMD23
BR001 HC1
DN 150

20GMD33
BR001 HC1
DN 100

20GMD23
BR002 HD2
DN 150

TT2-913-W103-00001 (D-10)

TT2-WWS-R103-00006 (B-8)

21LCQ43
BR002 HD2
DN 150

21GMD43
BR401 HB2
DN 300

FROM AIR HEATER WASHING

21LCQ43
BR001 HB2
DN 150

FROM BLOW DOWN TANK

FROM START-UP FLASH TANK

TT2-320-M103-00004 (B-11)

SEE BOILER DWG. B0213752

TT2-142-M103-00001 (J-11)

UG
AG

FROM BOTTOM ASH AREA

UG
AG

21GMD43
BR402 HD2
DN 300

20GMD31
AP001

20GMD32
AP001

20GMD21
AP001

BOILER BLOWDOWN SUMP PUMP

20GMD22
AP001

FOR CONSTRUCTION

START-UP FLASH TANK AREA SUMP PUMP

(2 x 100%)

(2 x 100%)

10

20.JAN.'15

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

22.APR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

Y.M.KIM

20.JAN.'15

DATE

CHECKED BY
C.H.JANG

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
WASTE WATER TRANSFER SYSTEM
(2/3)

SCALE

JOB NO.

DRAWING NUMBER

TT2-913-M103-00002
O

12
REV.

4
A1(841x594m/m)

DWG.NO

20GMA23
BR001 HB2
DN 50

TO STORM DRAIN

20GMA23
BR002 HD2
DN 50

LEGEND
TO STORM DRAIN

-GMA : DRAINAGE SYSTEM FOR STORM WATER DRAINS.

AG
UG

TT2-913-M103-00003

20GMA13
BR001 HB2
DN 65

*
*

LA++, +, 20GMA21CL201

DN50

20GMA22
AA002
20GMA22
AA001

20GMA22
BR001 HB2
DN 50

LA++
-

PI
20GMA21CP501

*
*

PI
20GMA22CP501

*
*

DN50

20GMA21
AA002
20GMA21
AA001
PI
20GMA12CP501

20GMA22
AA301

*
*

REFERENCE DRAWINGS

20GMA21
AA301

PI
20GMA11CP501

20GMA21
BR001 HB2
DN 50

20GMA12
AA301

LA++, +, 20GMA11CL201

20GMA12
BR001 HB2
DN 50

20GMA11
AA301

LA++
-

I
20GMA11
BR001 HB2
DN 50

DN50

20GMA12
AA002
20GMA12
AA001

20GMA11
AA001

DN50

20GMA11
AA002

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND VENT
POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.

20GMA11
AP001

20GMA12
AP001

20GMA21
AP001

CABLE TRENCH SUMP PUMP

20GMA22
AP001

SCAH DRAIN TANK AREA SUMP PUMP

(2 x 100%)

(2 x 100%)

20GMA43
BR001 HB2
DN 50

TO STORM DRAIN

20GMA44
BR001 HD2
DN 50

TO TT-1 DESANDER OVERFLOW DISCHARGE LINE

UG

20GMA33
BR001 HB2
DN 65

20GMA42
AA002

20GMA41
AA002

20GMA42
AA001

20GMA41
AA001

PI
20GMA41CP501

*
*

PI
20GMA42CP501

*
*

FOR CONSTRUCTION

20GMA42
AA301

LA++, +, 20GMA41CL201

20GMA42
BR001 HB2
DN 50

10

*
*

LA++
-

PI
20GMA32CP501

*
*

20GMA41
AA301

PI
20GMA31CP501

20GMA41
BR001 HB2
DN 50

20GMA32
AA301

LA++, +, 20GMA31CL201

20GMA32
BR001 HB2
DN 50

20GMA31
AA301

LA++
-

I
20GMA31
BR001 HB2
DN 50

DN50

20GMA32
AA002
20GMA32
AA001

20GMA31
AA001

DN50

20GMA31
AA002

AG

(GRAVITY)

FROM RAW WATER BUFFER PIT

20.JAN.'15

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

19.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

22.APR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P

TT2-919-M103-00002 (C-10)
CONTRACTOR:

11

11
PROJECT:

20GMA31
AP001

20GMA32
AP001

20GMA41
AP001

PIPE TRENCH SUMP PUMP

20GMA42
AP001

Termotasajero 2 161.6MW CFPP

RAW WATER SUPPLY PUMP AREA SUMP PUMP

(2 x 100%)

DRAWN BY

DATE

Y.M.KIM

20.JAN.'15

CHECKED BY

(2 x 100%)

DATE

C.H.JANG

20.JAN.'15

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

20.JAN.'15

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
WASTE WATER TRANSFER SYSTEM
(3/3)

SCALE

JOB NO.

DRAWING NUMBER

TT2-913-M103-00003
O

12
REV.

4
A1(841x594m/m)

PI
20GHA12CP502

20GHA81 20GHA81
AA004 AA005

UG
AG

20GHA88
AA002

20GHA86
BR001 HB2
DN 100

PT
20GHA04CP101

20GHA16
BR001 HB2
DN 50

20GHA17
BR001 HD2
DN 50

12

20GHA52
BR001 HB2
DN 25
20GHA52

20GHA82
AA312

20GHA09
AA002

20GHA14
BR001 HD2
DN 50

TO BOILER BLOWDOWN SUMP

TT2-913-M103-00002 (H-8)

20GHA07
AA002

TO PULV. C

TO PULV. D

20GHA82CF101B 20GHA82CF101C 20GHA82CF101D


20GHA82CF001B 20GHA82CF001C 20GHA82CF001D
20GHA83AA061B 20GHA83AA061C 20GHA83AA061D
20GHA83CF101B 20GHA83CF101C 20GHA83CF101D

20GHA83CF001B 20GHA83CF001C 20GHA83CF001D


20GHA82AT021

20GHA82AT031

20GHA82AT041

20GHA82AA321

20GHA82AA331

20GHA82AA341

20GHA82AA322

20GHA82AA332

20GHA82AA342

20GHA82BR021

20GHA82BR031

20GHA82BR041

20GHA83AT021

20GHA83AT031

20GHA83AT041

20GHA83AA321

20GHA83AA331

20GHA83AA341

20GHA83AA322

20GHA83AA332

20GHA83AA342

20GHA83BR021

20GHA83BR031

20GHA83BR041

20GHA83BR022

20GHA83BR032

20GHA83BR042

20GHA83BR023

20GHA83BR033

20GHA83BR043

20GHA83BR024

20GHA83BR034

20GHA83BR044

20GHA83AA022

20GHA83AA032

20GHA83AA042

20GHA84BR021

20GHA84BR031

20GHA84BR041

20GHA84AA021

20GHA84AA031

20GHA84AA041

TT2-142-M103-00001 (B-9)

20GHA08
AA002
20GHA08
AA001

TO PULV. B

20GHA82AA061B 20GHA82AA061C 20GHA82AA061D

TO BOILER BLOW DOWN TANK


QUENCHING

20GHA09
AA001

TO OVER FLOW MAKE UP


25 x 15

TT2-AHS-M103-00007 (H-10)

TO SDCC MAKE UP
50 x 40

20GHA07
AA001

TT2-AHS-M103-00007 (I-3)
9

TO START-UP FLASH TANK SUMP

TT2-913-M103-00002 (I-8)

FOR CONSTRUCTION

TO START-UP FLASH TANK

TT2-320-M103-00004 (M-11)

20GHA12
BR002 HB2
DN 50

AA001

20GHA72
AA001

20GHA62
AA001

20GHA62
BR001 HB2
DN 25

20GHA72
BR001 HB2
DN 25

20GHA22
BR001 HB2
DN 25

20GHA22
AA001

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

22.APR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

Termotasajero 2 161.6MW CFPP

GROUND FL.

MEZZANINE FL.

MEZZANINE FL.

MEZZANINE FL.

MEZZANINE FL.

OPERATING FL.

OPERATING FL.

OPERATING FL.

GROUND FL.

GROUND FL.

DN 25

PROJECT:

20GHA42
AA001

AA001

20GHA42
BR001 HB2
DN 25

20GHA51
BR001 HB2
DN 25
20GHA51

AA001

AA001

20GHA61
BR001 HB2
DN 25
20GHA61

20GHA71
BR001 HB2
DN 25
20GHA71

AA001

AA001

20GHA21
BR001 HB2
DN 25
20GHA21

20GHA31
BR001 HB2
DN 25
20GHA31

AA001

20GHA41
BR001 HB2
DN 25
20GHA41
OPERATING FL.

MEZZANINE FL.

20GHA32
20GHA32
AA001 BR001 HB2

TT2-AHS-M103-00005 (L-9)

20GHA12
BR001 HB2
DN 50

20GHA53
AA001

20GHA12
BR003 HB2
DN 50

MEZZANINE FL.

10

20GHA12
BR002 HB2
DN 50

TO FLY ASH UNLOADING CHUTE

TT2-FGD-R103-00011 (B-4)

AG
UG

20GHA06
BR001 HB2
DN 150

TT2-AHS-M103-00007 (K-10)

TO FGD SYSTEM

20GHA09
BR001 HB2
DN 100
20GHA08
BR003 HB2
DN 25
20GHA08
BR001 HB2
DN 40
20GHA07
BR002 HB2
DN 50
20GHA07
BR001 HB2
DN 100

20GHA12
BR003 HB2
DN 50

TO PULV. A
(Shown)
20GHA82AA061A
20GHA82CF101A
20GHA82CF001A
20GHA83AA061A
20GHA83CF101A
20GHA83CF001A
20GHA82AT011
20GHA82AA311
20GHA82AA312
20GHA82BR011
20GHA83AT011
20GHA83AA311
20GHA83AA312
20GHA83BR011
20GHA83BR012
20GHA83BR013
20GHA83BR014
20GHA83AA012
20GHA84BR011
20GHA84AA011

TO BOTTOM ASH UNLOADING


CHUTE

20GHA11
20GHA11
BR002 HB2 AA001
DN 15
20GHA11
20GHA11
BR003 HB2 AA002
DN 50

20GHA11
BR001 HB2
DN 50

20GHA10
BR001 HD2
DN 100
20GHA09
BR002 HB2
DN 50

20GHA04 20GHA04
AA003 AA004
UG
AG

NOTE 2

TT2-BLR-J-00089 (G-17)

20GHA53
BR001 HB2
DN 25

20GHA15
BR001 HD2
DN 50

QUENCHING WATER PUMP

TO AIR HEATER COLD END


WATER WASH

20GHA86
AT002

20GHA63
AA001

20GHA04
BR001 HB2
DN 150

***

20GHA63
BR001 HB2
DN 25

***

GROUND FL.

20GHA04 20GHA04
AA001
AA002

20GHA86
AT001

NOTE 2

TT2-BLR-J-00089 (K-17)

TO WATER TREATMENT SYSTEM

20GHA05
BR001 HB2
DN 100
PI
-

20GHA22
AP001

11

TO AIR HEATER HOT END


WATER WASH

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00089
[TRI-SECTOR AIR PREHEATER]
- TT2 - BLR - J - 161 - 00093
[PULVERISER INERTING & CLEARING
AHS SUPPLIER DWG.
- TT2 - AHS - M103 - 00005
FLY ASH SILO (P&ID)
- TT2 - AHS - M103 - 00007
BOTTOM ASH HANDLING SYSTEM P&ID
FGD SUPPLIER DWG.
- TT2 - FGD - R103 - 00011
P&ID FOR SDA MAKE-UP & COOLING WATER SYSTEM

NOTE 2

20GHA05
AA001

20GHA73
AA001

200 x 125

NOTE 2

TT2-BLR-J-00093 (F-10)

20GHA20
BR001 HD2
DN 100

RO
20GHA91BP001

20GHA04
BR002 HB2
DN 150
150 x 100

TT2-BLR-J-00093 (I-17)

TO PULVERIZER PYRITES
TRANSITION CHUTE&WASH

SUFFIX COMPARISON TABLE

20GHA73
BR001 HB2
DN 25

1. P&I DIAGRAMS
- TT2 - 320 - M103 - 00004
CONDENSATE DRAIN SYSTEM
- TT2 - 913 - M103 - 00002
WASTE WATER TRANSFER SYSTEM (2/3)
- TT2 - 142 - M103 - 00001
BLOWDOWN SYSTEM

NOTE 2

TT2-BLR-J-00093 (F-9)

20GHA86
AA001

REFERENCE DRAWINGS

TO PULVERIZER PA DUCT
HEADER WATER WASH

AG
UG

PI
20GHA22CP502

NOTE 2

TT2-BLR-J-00093 (H-10)

TO PULVERIZER PYRITES BOX


WATER WASH

***

UG
AG

PI
20GHA22CP501

20GHA83
BR014 HB2
DN 25

***

20GHA86
AA002

20GHA86
AS002

GROUND FL.

20GHA03
AT002

20GHA86
AS001

20GHA86
BR002 HB2
DN 100

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.
2. THIS DESIGNATION INDICATES TERMINAL
POINT OF REFERRED COORDINATE.
3. SERVICE WATER LINE FOR PULVERIZER A SHOWN.
PULVERIZER B THRU D ARE IDENTICAL EXCEPT FOR TAG
NUMBER SUFFIX. THE QUANTITY OF PIPE, INSTRUMENT,
STRAINER AND VALVE IS 4(FOUR).

NOTE 2

TO PULVERIZER SWIRLING
HEADER WATER WASH

AG
UG

20GHA21
AP001

20GHA83
BR012 HB2
DN 65

20GHA84
AA011

20GHA84
BR011 HB2
DN 15

AA001

20GHA03
AA002

PDIS
20GHA03CP202

20GHA03
BR002 HB2
DN 200

20GHA91
AA021

DN 150
BR001 HB2
20GHA04

150 x 100

TT2-BLR-J-00093 (H-10)

20GHA83
BR011 HB2
DN 80
80 x 65

UG
AG

20GHA13
BR001 HD2
DN 150

20GHA03
AA321

20GHA91
AA011
RO
20GHA91BP002

200 x 125

20GHA22
AA323

20GHA91
AA022

20GHA03
AA322

TT2-919-M103-00002 (N-3)

20GHA21
AA311

PDA+
-

FROM SURGE TANK

PI
20GHA21CP502

20GHA91
AA012

20GHA04
AA301

20GHA03
AT001

PI
20GHA21CP501
20GHA21
AA313

20GHA03
BR001 HB2
DN 200

20GHA22
AA321

20GHA03
AA001

PDIS
20GHA03CP201
20GHA03
AA312

20GHA03
AA311

20GHA82
BR011 HB2
DN 40

20GHA83
BR013 HB2
DN 50

20GHA87
BR003 HB2
DN 50

20GHA87
AA002

TO PULVERIZER FOGGING
HEADER

20GHA83
AA012

20GHA91
BR002 HB2
DN 65

PDA+
-

FE
20GHA83CF001A

FC

20GHA87
BR002 HB2
DN 50

20GHA87
AA001

FT
20GHA83CF101A

20GHA83
AT011

AA003

20GHA88
BR002 HB2
DN 50

TO PULVERIZER AREA

XV
20GHA83AA061A

20GHA88
BR003 HB2
DN 50

20GHA88
AA001

TO COAL FEEDER FLOOR AREA

20GHA81
20GHA81
BR004 HB2
BR005 HB2
DN 100 100 x 80 20GHA81 DN 80

20GHA23
BR001 HB2
DN 25
20GHA23

20GHA81
BR002 HB2
DN 80

SERVICE WATER PUMP

3
20GHA19
BR001 HD2
DN 100

OPERATING FL.

TO COAL TRIPPER GALLERY AREA

NOTES

FC

20GHA33
AA001

PT
20GHA81CP101

20GHA33
BR001 HB2
DN 25

PI
20GHA12CP501

PT
20GHA81CP102

20GHA81
BR003 HB2
DN 100

20GHA91
BR001 HB2
DN 65

- GHA : DISTRIBUTION SYSTEM AFTER TREATMENT


(SERVICE WATER)

20GHA83
AA312

20GHA81 20GHA81
AA001
AA002

FE
20GHA82CF001A

20GHA82
AT011

OPERATING FL.

DN 80
BR001 HB2
20GHA81

PI
-

20GHA83
AA311

RO
20GHA90BP001

FT
20GHA82CF101A

20GHA82
AA311

XV
20GHA82AA061A

20GHA81
AA301

20GHA90
AA021

TO COAL CRUSHER HOUSE AREA

TT2-919-M103-00002 (N-3)

NOTE 3

(2 x 100%)
20GHA12
AP001

TO SURGE TANK

AG
UG

20GHA80
AA322

20GHA90
AA011
RO
20GHA90BP002

150 x 100

20GHA80
AT002

20GHA90
AA022

UG
AG

20GHA87
BR001 HB2
DN 50

20GHA11
AP001

PDIS
20GHA80CP202

20GHA80
AA002

20GHA90
AA012

AG
UG

3
20GHA80
BR002 HB2
DN 150

TT2-919-M103-00002 (N-3)

20GHA80
BR001 HB2
DN 150

PI
20GHA11CP502

150 x 100

20GHA80
AT001
PDA+
-

20GHA80
AA321

FROM SURGE TANK

PI
20GHA11CP501

20GHA11
AA311

20GHA80
AA312

20GHA80
AA001

PDIS
20GHA80CP201

LEGEND

20GHA85
BR001 HB2
DN 100

20GHA80
AA311

UG
AG

PDA+
-

20GHA11
AA313

20GHA90
BR002 HB2
DN 50

20GHA12
AA323

TT2-919-M103-00001

TT2-919-M103-00002 (N-2)

20GHA90
BR001 HB2
DN 50

20GHA88
BR001 HD2
DN 50

DWG.NO

TO SURGE TANK

20GHA81
AA302

20GHA18
BR001 HD2
DN 50

20GHA12
AA321

DRAWN BY

DATE

Y.M.KIM

15.OCT.'14

CHECKED BY

DATE

C.H.JANG

15.OCT.'14

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
I

DATE

S.H.KIM

15.OCT.'14

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
SERVICE WATER DISTRIBUTION
SYSTEM
SCALE

JOB NO.

DRAWING NUMBER

TT2-919-M103-00001
O

12
REV.

3
A1(841x594m/m)

DWG.NO

LEGEND

TT2-919-M103-00002

SEE "CIRCULATING WATER MAKEUP TREATMENT SYSTEM P&ID (1/4)


[TT2-912-W103-00001]"

- GAC : PIPING, CHANNEL AND PUMP SYSTEM


(RAW WATER)

FROM SODIUM HYPOCHLORITE


CLARIFIER FEED PUMPS

22GAC38
BR001 HD2
DN 350

22GAC23
AA001

AG
UG

20GHA90
BR001 HB2
DN 50
20GHA90
AS001

22GAC23
BR001 HB2
DN 350

20GHA91
AS001
20GHA80
AS001

UG
AG

22GAC37
BR001 HB2
DN 350

HB2

UG
AG

HG1

20QCH10
BR001 HG1
DN 25

TT2-CFS-R103-00001 (H-12)

20GHA03
AS001

HD2

20GHA91
BR001 HB2
DN 65
20GHA80
BR001 HB2
DN 150
20GHA03
BR001 HB2
DN 200

NOTES

FROM SERVICE WATER PUMP


RECIRCULATION

1. THE QUANTITY AND LOCATION OF DRAIN AND


VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

TT2-919-M103-00001 (B-1)
FROM QUENCHING WATER
PUMP RECIRCULATION

REFERENCE DRAWINGS

TT2-919-M103-00001 (B-7)

1. P&I DIAGRAMS
- TT2 - 500 - M103 - 00001
CIRCULATING WATER SYSTEM (1/2)
2. VENDOR DWG.

TO SERVICE WATER PUMP

TT2-919-M103-00001 (B-2)
TO QUENCHING WATER PUMP

TT2-919-M103-00001 (B-9)
3

SURGE TANK
(1 X 100%)
22PAE10
KD001

HB2

22GAC41
BR001 HB2
DN
100
22GAC41

22GAC36
BR001 HD2
DN 350

CLARIFIER

AG
UG

HD2

UG
AG

22GAC35
BR001 HB2
DN 350

22PAR20
AS001

AA401

HB2
5

22GAC34
BR001 HD2
DN 350

22GAC40
BR001 HB2
22GAC40 DN 100
AA401

22GAC33
BR001 HB2
DN 350

AG
UG

PDIS
22GAC11CP
22GAC11
AA302

22GAF20*
AA303

22GAC22
BR001 HB2
DN 350 22GAC22

22PAR20
BR001 HB2
DN 250

MOV
22PAR20AA041
M

TT2-500-M103-00001 (N-6)

22PAR03
BR001 HB2
DN 350 22PAR03 22PAR03

TT2-500-M103-00001 (N-5)

22PAR03
BR001 HB2
DN 350

350 x

PDIS
22PAR01CP201

450 x

22PAR01
AT001

20PAS10
AP001

*
22PAR04
BR001 HB2
DN 350

22PAR04 22PAR04
AA002 AA001

PI
20PAS20CP501

Y.M.KIM

C.H.JANG

S.H.KIM

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

22.APR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

CONTRACTOR:

22PAR02
AT001

11
PROJECT:

Termotasajero 2 161.6MW CFPP


22PAR02
BR001 HB2
DN 450
22PAR02

DRAWN BY

DATE

Y.M.KIM

15.OCT.'14

CHECKED BY

AA001

COOLING TOWER MAKE UP PUMP


(2 X 100%)
20PAS20
AP001

12

FOR CONSTRUCTION

26.MAR.'14

22PAR01
AS001

PDIS
22PAR02CP201

450 x

350 x

15.OCT.'14

Termotasajero Dos S.A. E.S.P

AA001

PDA+
-

PI
20PAS20CP502

22PAR01
BR001 HB2
DN 450
22PAR01

EMPLOYER:

UG
AG

AG
UG

11

22PAR05
BR001 HD2
DN 350

AA001

PI
-

22PAR03
AA311

22PAR10
BR001 HB2
DN 350

AA002

PI
20PAS10CP501

22PAR20
AA001

PT
22PAR03CP101

PI
20PAS10CP502

22PAR01
AA301

RAW WATER PUMP STATION

FROM COOLING OIWER BASIN


LVL HH

TO COOLING TOWER

PDA+
-

22PAR01
AA302

TT2-913-M103-00003 (M-11)

FOR CONSTRUCTION

RAW WATER SUPPLY PUMP


(2 X 100%)
22GAF30
AP001

TO RAW WATER SUPPLY PUMP


AREA SUMP PIT

AA002

22PAR02
AA301

350 x 200 22GAC22


AA001

450 x 250

22GAC12
AT001

22GAF30
AA301

22PAR02
AA302

22PAR01
BR001 HB2
DN 450

PI
22GAF30CP502

20PAS10
AA301

20PAS20
AA301

22GAC12
AA301

PI
22GAF30CP501

22GAF30*
AA303

RAW WATER BUFFER PIT


10

20PAS10
AA302

SCREEN

DN 350
BR001 HB2
22GAC31

20PAS20
AA302

FROM TT1
DESANDER "B"
AT INTAKE
SLUICE
(EXISTING)
GATE

22GAC12
AA302

(GRAVITY)

22GAC12
AA001

AA002

UG
AG

22GAC31

22GAC21
AA302
BR001 HB2
DN 350 22GAC21

PDIS
22GAC12CP

22GAC12
BR001 HB2
DN 450

22GAF20
AA301
350 x 200 22GAC21
AA001

PDA+
-

22GAC11
AS001

PT
22GAC31CP101

22GAF20
AP001

FROM TT1
DESANDER "A"
AT INTAKE
SLUICE
(EXISTING)
GATE

450 x 250

22GAC11
AT001

AA001

PI
22GAF20CP502

22GAC22
BR001 HB2
DN 350

22GAC11
AA301

22GAC11
BR001 HB2
DN 450 22GAC11

PI
22GAF20CP501

AA401

PI
-

DN 350
BR001 HD2
22GAC32

PDA+
-

LT
22GAF20CL111

HB2

22GAC39
BR001 HB2
22GAC39 DN 100

LI
-

HD2

UG
AG

C.H.JANG

P&I DIAGRAM
RAW WATER SUPPLY SYSTEM

15.OCT.'14

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.

TITLE:

DATE
DATE

S.H.KIM

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-919-M103-00002
O

REV.

3
A1(841x594m/m)

DWG.NO

TT2-921-M103-00001

LEGEND
- QEA : CENTRAL COMPRESSED AIR AND
CARRIER AIR GENERATION SYSTEM
- QFA : CENTRAL CONTROL AIR GENGERATION
SYSTEM

PI
-

NOTES

UNIT 1
COMPRESSED AIR SYSTEM

10QEA01
BR001 HB2
DN 100
10QEA01

10QEA10
AA301

PT
10QEA10CP101

NOTE 2

MOV
10QEA10AA041

TO INSTRUMENT AIR
DISTRIBUTION SYSTEM

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.
2. MOV(10QEA10AA041) WILL BE CLOSED WHEN PLANT
START-UP SINCE HIGHER AIR PRESSURE THAN TT1
PIPING DESIGN. IT WILL BE OPENED ONLY WHEN NORMAL
OPERATING FOR SHARING AIR WITH TT1. BEFORE OPENING
THE MOV, SETTING PRESSURE OF AIR COMPRESSURE
SHALL BE CLARIFIED AS SPECIFIED NOTE 3.
3. MICOM PANEL SETTING PRESSURE FOR AIR COMPRESSURE
- START-UP : 10 barg
- NORMAL OPERATING : 7.8 barg

TT2-921-M103-00002 (A-10)
PS

10QEA10
BR001 HB2
DN 100

AA001

PA
TI
-

20QFA10
AA302
PI

PI

20QFA10
AA301

PDI

3
PT

TT
20QFA10CT101

1. P&I DIAGRAMS
- TT2 - 921 - M103 - 00002
INSTRUMENT AIR DISTRIBUTION SYSTEM
- TT2 - 921 - M103 - 00003
SERVICE AIR DISTRIBUTION SYSTEM

PI
PT
20QFA10CP111

2. VENDOR DWG.
- TT2 - ACS - M103 - 00001
P&I DIAGRAM FOR COMPRESSED AIR SYSTEM
- TT2 - ACS - M103 - 00002
P&I DIAGRAM FOR AIR COMPRESSOR
- TT2 - ACS - M103 - 00003
P&I DIAGRAM FOR AIR DRYER

ACS TP1

PI

REFERENCE DRAWINGS

PI
20QFA10CP521

20QFA10
BR001 HC1
DN 80

ACS TP3

SEE SUPPLIER'S DWG NO. : TT2-ACS-M103-00001

XV

80 x 65

PT

NOTE 3

TI

PDI
XV

XV

20QFA50
KT001
20QFA30
KT001
TT

AIR COMPRESSOR PACKAGE


(1 X 100%)
20QEA10
AN001

20QFA10
KT001

PS

PA
-

AIR RECEIVER
20QEA10
BB001

PI

PI

PDI

PDI

TO SERVICE AIR
DISTRIBUTION SYSTEM

XV

PRE FILTER
(2 X 100%)
20QFA20
KT001

ACS TP2

TT2-921-M103-00003 (C-8)

AFTER FILTER
(2 X 100%)
20QFA60
KT001
XV

TI
-

XV

AIR DRYER PACKAGE


(2 X 100%)
20QFA40
KT001

20QEA10
AA302

10

20QEA10
AA303

FOR CONSTRUCTION

TT
20QEA10CT102
PI
20QEA10CP521

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

PI
-

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

PT
20QEA10CP112

08.JUL'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

20QEA09
BR001 HB2
DN 150

11

Termotasajero Dos S.A. E.S.P

XV
20QEA09AA071

FC
20QEA09
AA401

20QEA09
AA001

CONTRACTOR:

20QEA10
BR001 HB2
DN 150

20QEA10
AA001

11
PROJECT:

Termotasajero 2 161.6MW CFPP

20QEA09
AA002

DRAWN BY

DATE

Y.M.KIM

15.OCT.'14

CHECKED BY

DATE

C.H.JANG

15.OCT.'14

APPROVED BY

12

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
COMPRESSED AIR SUPPLY SYSTEM

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-921-M103-00001
O

REV.

3
A1(841x594m/m)

20QFB52
AA001

20QFB71
AA002
20QFB71
AA003

I.D FAN AREA

20QFB72
AA001

20QFB51
BR001 HC1
WASTE WATER
DN 25
20QFB51 TREATMENT BUILDING
UG
AG

20QFB37
BR001 HD2
DN 25

UG
AG

20QFB61
AA001

AA001

20QFB55
BR001 HC1
DN 25
20QFB55

AG
UG

STACK AREA

20QFB62
AA001

UG
AG

FLUE GAS
ANALY. AREA

20QFB70
AA002
20QFB73
AA001

20QFB53
TO COAL CRUSHER HOUSE
BR001 HC1
TT2-CHS-M103-00004 (G-6)
DN 50
20QFB53

20QFB74
AA001

20QFB65
AA001

I.D FAN AREA

UG
AG

20QFB56
BR001 HC1
DN 50

20QFB60
BR001 HC1
DN 80

20QFB19
BR001 HD2
DN 50

TO FLY ASH TRANSFER VESSEL


AREA
TT2-AHS-M103-00008 (A-2)

20QFB66
AA001

SDA AREA

20QFB69
AA001

UG
AG

20QFB85
BR001 HD2
DN 50

20QFB65
BR001 HC1
DN 40
AIR PREHEATER
COLD / HOT END AREA

20QFB65
BR002 HC1
DN 40

ECO. ASH AUX. HOPPER


& A/H HOPPER AREA

20QFB66
BR001 HC1
DN 25

20QFB76
AA002

TT2-AHS-M103-00004 (Q-3)

20QFB69
BR001 HC1
DN 25

20QFB76
AA003

FW CONTROL VALVE
STATION

20QFB76
AA004

20QFB76
AA006

UG
AG

AA001

20QFB50
BR001 HD2
DN 80

PT
20QFA10CP103
UG
AG

PI
20QFB60CP501

20QFB68
AA001
20QFB60
AA301

20QFB60
AA001

20QFB13
AA001

20QFB68
BR001 HC1
DN 25

SPARE

20QFB76
BR009 HC1
DN 25
DN 25
BR010 HC1
20QFB76

BURNER
AREA

20QFB76
AA010

20QFB70
AA003

20QFB67
AA001

R/H ATTEMPERATOR
AREA

20QFB67
AA002

20QFB81
AA002

BOILER S/H AREA

20QFB81
AA003

20QFB80
AA002

SPARE

BOILER SOOT BLOWER AREA

20QFB84
AA001

AH SOOT BLOWER AREA


20QFB85
AA001

SA & NOX PORT


WIND BOX DAMPER
20QFB85
AA002

20QFB86
AA001

20QFB80
AA003

20QFB87
AA001

BURNER
AREA

20QFB88
AA001

20QFB88
AA002

20QFB89
AA001

SPARE

20QFB82
AA001

20QFB13
AA002

20QFB83
AA001

- QFA : CENTRAL CONTROL AIR GENERATION


SYSTEM
- QFB : CENTRAL CONTROL AIR DISTRIBUTION
SYSTEM

20QFB67
BR001 HC1
DN 40
F.D FAN
"A" & "B" AREA

20QFB67
BR002 HC1
DN 40

20QFB28
AA001

20QFB27
AA001

20QFB26
AA001

20QFB23
AA001

20QFB25
AA001

20QFB48
AA001

20QFB21
AA001

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND VENT
POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.

20QFB81
BR002 HC1
DN 25

REAR WALL KNIFE GATE VALVES


CLEAN OUT

REFERENCE DRAWINGS

20QFB81
BR003 HC1
DN 25

FRONT WALL KNIFE GATE VALVES


CLEAN OUT

1. P&I DIAGRAMS
- TT2 - 921- M103 - 00001
COMPRESSED AIR SUPPLY SYSTEM

20QFB80
BR002 HC1
DN 25

2. VENDOR DWG.
AHS SUPPLIER DWG.
- TT2 - AHS - M103 - 00004
P&ID FOR FOR E.C.O HOPPER LINE
- TT2 - AHS - M103 - 00008
P&ID FOR FOR INSTRUMENT AIR LINE
CHS SUPPLIER DWG.
- TT2 - CHS - M103 - 00004
P&ID FOR DUST COLLECTION SYSTEM

SPARE

20QFB84
BR001 HC1
DN 25

PULVERIZER "A" AREA

20QFB85
BR001 HC1
DN 25
PULVERIZER "A" & "B" PA AREA

20QFB85
BR002 HC1
DN 25
20QFB86
BR001 HC1
DN 25
20QFB80
BR003 HC1
DN 25

SPARE

20QFB87
BR001 HC1
DN 25

PULVERIZER "C" AREA

20QFB88
BR001 HC1
DN 25

PULVERIZER "C" & "D" PA AREA

20QFB88
BR002 HC1
DN 25
20QFB89
BR001 HC1
DN 25

PULVERIZER "D" AREA


7

20QFB82
TO SDCC AREA
BR001 HC1
TT2-AHS-M103-00008 (B-10)
DN 50

20QFB83
BR001 HC1
DN 25

20QFB43
BR001 HC1 H.P HEATER
5 AREA
DN 25

20QFB42
AA001

20QFB41
AA001

20QFB22
AA002

DN 40
BR001 HC1
20QFB40

20QFB41
BR001 HC1
DN 25

20QFB29
AA001

20QFB40
BR001 HC1
DN 25

PULV. SEAL AIR FAN AREA

FOR CONSTRUCTION

H.P HEATER
6 AREA

SPARE

20QFB46
AA001

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

CHKD

APPD

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11
PROJECT:

Termotasajero 2 161.6MW CFPP

20QFB47
AA001

DESCRIPTION

10

EMPLOYER:

20QFB24
BR001 HC1
DN 25

20QFB24
AA001

DRAWN BY

DATE

Y.M.KIM

15.OCT.'14

CONDENSER
AREA

CHECKED BY

(TURBINE BLDG AREA)

APPROVED BY

DATE

C.H.JANG

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
C

PULVERIZER "B" AREA

20QFB47
BR001 HC1 C&D LUBE OIL
TANK AREA
DN 25

20QFB44
BR001 HC1 C.C.W TANK
AREA
DN 25

20QFB42
BR001 HC1
DN 25

12

20QFB22
BR001AHC1 COND. VAC.
PUUMP AREA
DN 25

SPARE

22MAJ20AT001/F

20QFB43
AA001

20QFB21
BR001 HC1
DN 25

22MAJ10AT001/F

20QFB48
BR001 HC1
DN 25

SPARE

20QFB25
BR001 HC1
DN 25

20QFB23
BR001 HC1
BFP AREA
DN 25

20QFB26
BR001 HC1 HTR DRAIN
PUMP AREA
DN 25

20QFB31
BR001 HC1
DN 25

20QFB40
AA001

20QFB20
AA001

20QFB27
BR001 HC1
SPARE
DN 25

20QFB31
AA001

LUBE OIL
SYSTEM

20QFB32
BR001 HC1
DN 25

20QFB32
AA001

GLAND STEAM
CONDENSER

20QFB33
BR001 HC1
LP HEATER
DN 25

20QFB33
AA001

WATER ANALYSIS
SYS. & SAMPLING
SYS. AREA

20QFB30
BR001 HC1
DN 40

20QFB28
BR001 HC1
DN 25

20QFB20
BR001 HC1
DN 40

20QFB44
AA001

20QFB40
BR001 HC1
DN 40
20QFB45
BR001 HC1 DEAERATOR
AREA
DN 25

IPB
SYSTEM

20QFB40
BR001 HC1
DN 40

20QFB11
AA001

(BOILER BLDG AREA)

20QFB46
BR001 HC1
TR AREA
DN 25

20QFB45
AA001

20QFB34
BR001 HC1
SPARE
DN 25

20QFB76
AA008

S/H ATTEMPERATOR
AREA

20QFB13
AA003

20QFB11
BR001 HC1
DN 40

11

20QFB76
AA009

LEGEND

DN 80
BR001 HC1
20QFB12

20QFA10
AA002

20QFB34
AA001

20QFB76
AA007

20QFB13
BR001 HC1
DN 80

20QFA10
BR001 HC1
DN 80

TT2-921-M103-00001 (M-2)

20QFB75
AA002
20QFB76
AA001

20QFB81
TO COAL TRIPPER GALLERY
BR001 HC1
TT2- CHS-M103-00004 (J-1)
DN 50
20QFB81

FROM AIR COMPRESSOR


AFTER FILTER

20QFB75
AA001

20QFB76
AA005

PI
-

BOILER DRUM AREA

20QFB29
BR001 HC1
DN 25

20QFB65
AA002

20QFB56
AA001

20QFB52
BR003 HD2
DN 50

20QFB72
AA004

CONTINUOUS EMISSION
MONITORING SYSTEM

AA002

20QFA10
AA303

20QFB62
BR001 HC1
DN 40

AA001

20QFB52
BR002 HC1
DN 40
20QFB52

20QFB14
BR001 HD2
DN 80

20QFB72
AA003

SPARE

AA001

20QFB18
BR001 HD2
DN 40

20QFB61
BR001 HC1
DN 25

20QFB70
BR001 HC1
DN 80

20QFB15
BR001 HC1
DN 80

20QFB72
AA002

AA001

20QFB54
BR001 HC1
DN 25
20QFB54

20QFB36
BR001 HD2
DN 80

TT2-AHS-M103-0008 (B-8)

20QFB71
BR001 HC1
DN 40
20QFB71
BR002 HC1
DN 25
20QFB71
BR003 HC1
DN 25
20QFB72
BR001 HC1
DN 25
20QFB72
BR002 HC1
DN 25
20QFB72
BR003 HC1
DN 25
20QFB72
BR004 HC1
DN 25
20QFB70
BR002 HC1
DN 25
20QFB73
BR001 HC1
DN 25
20QFB74
BR001 HC1
DN 25
20QFB75
BR001 HC1
DN 25
20QFB75
BR002 HC1
DN 25
20QFB76
BR001 HC1
DN 25
20QFB76
BR002 HC1
DN 25
20QFB76
BR003 HC1
DN 25
20QFB76
BR004 HC1
DN 25
20QFB76
BR005 HC1
DN 25
20QFB76
BR006 HC1
DN 25
20QFB76
BR007 HC1
DN 25
20QFB76
BR008 HC1
DN 25
20QFB70
BR003 HC1
DN 25

20QFB80
BR001 HC1
DN 80

20QFB57
AA001

20QFB52
BR001 HC1
DN 50

UG
AG

AG
UG

20QFB71
AA001

TO ASH SILO AREA

UG
AG

80 x 50

20QFB17
BR001 HD2
DN 50

10

20QFB40
BR001AHC1
DN 40

UG
AG

20QFB57
BR001 HC1
DN 50

UG
AG

TT2-921-M103-00002

20QFB16
BR001 HD2
DN 50

DWG.NO

15.OCT.'14

DATE

S.H.KIM

15.OCT.'14

HD CLASSIFICATION NO.

TITLE:

P&I DIAGRAM
INSTRUMENT AIR DISTRIBUTION
SYSTEM

SCALE

JOB NO.

DRAWING NUMBER

TT2-921-M103-00002
O

12
REV.

3
A1(841x594m/m)

TT2-921-M103-00003

DWG.NO

LEGEND

COAL CRUSHER
HOUSE

20QEB61
AA001

20QEB57
BR001 HB2
DN 25

20QEB57
AA001

AG
UG

UG
AG

20QEB17
BR001 HD2
DN 40
5

AQCS ELECTRICAL
BUILDING

AA001

20QEB73
BR005 HB2
SPARE
DN 25

AG
UG

20QEB73
BR010 HB2
DN 25

COAL TRIPPER
GALLERY

20QEB60
BR001 HB2
DN 25

20QEB73
BR004 HB2
PULVERIZER "C"
DN 25

3
PI
20QEB15CP501

20QEB73
BR003 HB2
PULVERIZER "D"
DN 25

20QEB73
AA010

STEAM AND WATER


SAMPLING &
ANALYSIS SYSTEM

20QEB60
AA001

20QEB73
BR006 HB2
DN 25

PULVERIZER "B"

UG
AG

20QEB52
BR001 HB2
DN 25 20QEB52

20QEB73
BR007 HB2
PULVERIZER "A"
DN 25

20QEB19
BR001 HD2
DN 40

AA001

20QEB26
BR001 HD2
DN 40

20QEB73
BR008 HB2
DN 25

BOTTOM ASH
EXTRACTION CONVEYOR

20QEB55
BR001 HB2
DN 25
20QEB55

I.D FAN
"A" & "B" AREA

20QEB73
BR009 HB2
DN 25

SPARE

I.D FAN
"A" & "B" AREA

20QEB18
BR001 HB2
DN 40
4

20QEB73
BR002 HB2
DN 25

SPARE

UG
AG

20QEB71
AA005

20QEB72
BR011 HB2
DN 25

20QEB73
AA009

20QEB73
AA008

20QEB74
BR007 HB2
TT2-BLR-J-161-00087 (N-12)
DN 25
TO RH GAS TEMPERATURE
PROBE 20QEB74
BR006 HB2
TT2-BLR-J-161-00087 (N-12)
DN 25

20QEB15
BR003 HB2
DN 40

20QEB74
AA007

20QEB74
AA006

20QEB74
BR005 HB2
TT2-BLR-J-161-00087 (K-12)
DN 25

20QEB74
AA005

20QEB74
BR004 HB2
TT2-BLR-J-161-00087 (K-12)
DN 25

20QEB73
AA005

20QEB72
BR003 HB2
DN 25

20QEB73
AA002

20QEB72
SPARE BR002 HB2
DN 25

80 x 50

80 x 50

20QEB16
AA003

20QEB16
AA005

20QEB15
AA303

COOLING TOWER
AREA

20QEB53
BR001 HB2
DN 25

C.W PUMP
AREA

20QEB10
AA301

20QEB46
AA001

20QEB11
AA001

(GROUND FL.)

22QEB45
AA001

20QEB14
BR001 HB2
DN 50

20QEB14
AA001

20QEB41
AA001

20QEB31
BR001 HB2
DN 25

20QEB31
AA001

20QEB32
BR001 HB2
DN 25

20QEB32
AA001

20QEB33
BR001 HB2
DN 25

20QEB33
AA001

20QEB34
BR001 HB2
DN 25

20QEB34
AA001

20QEB35
BR001 HB2
DN 25

20QEB35
AA001

20QEB36
BR001 HB2
DN 25

20QEB36
AA001

20QEB21
BR001 HB2
DN 25

20QEB21
AA001

20QEB22
BR001 HB2
DN 25

20QEB22
AA001

20QEB23
BR001 HB2
DN 25

11

20QEB23
AA001

20QEB14
BR001 HB2
DN 50
20QEB13
BR001 HB2
DN 50

(MEZZ. FL.)

20QEB24
BR001 HB2
DN 25

20QEB25
BR001 HB2
DN 25

20QEB24
AA001

20QEB72
AA010

PA FAN
"A" & "B" AREA

20QEB71
BR010 HB2
DN 25

TO AIR HEATER AUX MOTOR

20QEB71
BR004 HB2
DN 25

TT2-BLR-J-161-00089 (I-6)
SPARE

20QEB72
AA009

20QEB72
AA008

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00087
FLUE GAS SYSTEM
- TT2 - BLR - J - 161 - 00089
HOWDEN TRI-SECTOR AIR HEATER
- TT2 - BLR - J - 161 - 00096
IGNITER OIL HEADER SYSTEM

20QEB71
AA010

20QEB71
AA004

PRV
20QEB81AA071

***

***

20QEB81 OIL MISTER


AA701

20QEB72
AA007

TO AIR HEATER SOOT BLOWER


TT2-BLR-J-161-00089 (D-22)

20QEB82
BR001 HB2
DN 25
AIR HEATER
AREA

20QEB72
AA004

SPARE

20QEB72
AA003

***

20QEB81 20QEB81 20QEB81


AT001 AA001 AA003
MOV
20QEB82AA041
20QEB82
AA001

20QEB72
AA005

20QEB72
AA002

20QEB74
BR002 HB2
DN 50

1. P&I DIAGRAMS
- TT2 - 921 - M103 - 00001
COMPRESSED AIR SUPPLY SYSTEM

***

***

20QEB72
AA006

20QEB71
AA006

20QEB71
BR013 HB2
DN 25
20QEB71
BR014 HB2
DN 25

20QEB82
AA002

20QEB71
AA013

20QEB71
AA014

80 x 50

80 x 50

20QEB15
AA002

20QEB15
AA001

TO IGNITOR OIL HEADER


TT2-BLR-J-161-00096 (M-22)

20QEB42
AA001

20QEB46
BR001 HB2
DN 25
22QEB45
BR001 HB2
DN 25

FOR CONSTRUCTION

DEAERATOR FL.

TO ACCU ON LOWER ROOF

(OPERATION FL.)
20QEB43
AA001

15.OCT.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P

20QEB44
AA001

CONTRACTOR:

20QEB44
BR001 HB2
DN 25

UG
AG

20QEB25
AA001

20QEB72
AA011

REFERENCE DRAWINGS

20QEB14
AA001
10

20QEB71
BR006 HB2
DN 25

20QEB71
AA007

20QEB10
BR001 HB2
DN 50

20QEB54
BR001 HB2
DN 25

20QEB12
BR001 HB2
DN 50

20QEB53
AA001

20QEB72
AA012

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.

20QEB15
BR002 HB2
DN 80

150 x 80

20QEB42
BR001 HB2
DN 25

20QEB54
AA001

20QEB74
AA002

20QEB71
BR007 HB2
DN 25

NOTES

20QEB71
AA008

(BOILER BLDG. AREA)

20QEB41
BR001 HB2
DN 25

UG
AG

UG
AG

20QEB38
BR001 HD2
DN 25

20QEB72
BR004 HB2
DN 25

20QEB73
AA003

PI
20QEB10CP503

20QEB72
BR005 HB2
DN 25

20QEB74
AA003

20QEB73
AA004

20QEB43
BR001 HB2
DN 25

TT2-921-M103-00001 (N-9)

20QEB72
BR006 HB2
DN 25

20QEB74
AA004

20QEB74
BR003 HB2
SPARE
DN 25

20QEA10
BR001 HB2
DN 150

FROM AIR COMPRESSOR

20QEB72
BR007 HB2
DN 25

TO RW FURNACE CAMERA

PI
20QEB15CP502
8

20QEB72
BR008 HB2
DN 25

TO FW FURNACE CAMERA

20QEB73
AA006

20QEB15
AA301

20QEB72
BOILER
BR009 HB2
STRUCTURE
DN 25
FLOOR

TO CW GAS TEMPERATURE
PROBE

20QEB73
AA007

20QEB72
BR010 HB2
DN 25

STEAM COIL
AIR HEATER
AREA

(REAR SIDE)

20QEB61
BR001 HB2
DN 25

AA001

WASTE WATER
LIFT STATION

20QEB51
AA001

20QEB71
BR005 HB2
DN 25

20QEB72
BR012 HB2
DN 25

20QEB74
BR001 HB2
DN 50

22QEB20
BR001 HD2
DN 25

FD FAN
"A" & "B" AREA

20QEB71
AA011

20QEB72
AA013

20QEB71
AA009

20QEB16
BR001 HB2
DN 80

WASTE WATER
TREATMENT BUILDING

20QEB51
BR001 HB2
DN 25

CONTINUOUS EMISSION
MONITORING SYSTEM

20QEB59
AA001

(PULVERIZER AREA)

22QEB50
BR001 HB2
DN 25 22QEB50

UG
AG

20QEB71
BR011 HB2
DN 25

20QEB73
BR001 HB2
DN 50

20QEB59
BR001 HB2
DN 25

20QEB71
BR008 HB2
DN 25

-QEA : CENTRAL COMRESSED AIR AND CARRIER AIR


GENERATION SYSTEM
-QEB : CENTRAL COMRESSED AIR AND CARRIER AIR
DISTRIBUTION SYSTEM

20QEB71
BR001 HB2
DN 50

20QEB72
BR013 HB2
DN 25

20QEB71
BR009 HB2
DN 25

SPARE

20QEB72
AA014

20QEB81
BR001 HB2
DN 25

20QEB72
BR014 HB2
DN 25

DN 50
BR001 HB2
20QEB72

11
PROJECT:

TO HVAC ROOM

Termotasajero 2 161.6MW CFPP

12

DATE

Y.M.KIM

15.OCT.'14

DATE

CHECKED BY
C.H.JANG

15.OCT.'14

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.

(TURBINE BLDG. AREA)

DRAWN BY

DATE

S.H.KIM

TITLE:

P&I DIAGRAM
SERVICE AIR DISTRIBUTION SYSTEM

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-921-M103-00003
O

REV.

3
A1(841x594m/m)

DWG.NO

TT2-923-M103-00001

LEGEND
1

-QJB : GAS SUPPLY AND DISTRIBUTION SYSTEM N2

NOTES

VENT TO
SAFETY AREA
TI
-

PT

PI

TT

PSV

PI

TI

ATM

TO HP FWH 6 TUBE SIDE

20QJB52
BR001 HB1
DN 25

TO LP FWH 2 TUBE SIDE

20QJB39
BR001 HB1
DN 25

TO HP FWH 6 SHELL SIDE

TT2-330-M103-00002 (H-6)

TT2-320-M103-00003 (H-6)

20QJB35
BR001 HB1
DN 25

TO CRH DRAIN POT

20QJB36
BR001 HB1
DN 25

TO HRH DRAIN POT

20QJB30
BR001 HB1
20QJB30 DN 25

TT2-313-M103-00001 (A-10)

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.
2

TT2-311-M103-00002 (I-10)

REFERENCE DRAWINGS
1. P&I DIAGRAMS
- TT2-999-M103-00001 SYMBOL & LEGEND (1/3)
- TT2-999-M103-00001 SYMBOL & LEGEND (2/3)
- TT2-999-M103-00001 SYMBOL & LEGEND (3/3)
- TT2-311-M103-00001
MAIN AND REHEAT STEAM SYSTEM (1/3)
- TT2-311-M103-00002
MAIN AND REHEAT STEAM SYSTEM (2/3)
- TT2-311-M103-00003
MAIN AND REHEAT STEAM SYSTEM (3/3)
- TT2-313-M103-00001
FWH EXTRACTION STEAM SYSTEM (1/2)
- TT2-313-M103-00002
FWH EXTRACTION STEAM SYSTEM (2/2)
- TT2-314-M103-00003
FWH VENT AND DRAIN SYSTEM(3/3)
- TT2-320-M103-00002
CONDENSATE SYSTEM (2/3)
- TT2-320-M103-00003
CONDENSATE SYSTEM (3/3)
- TT2-330-M103-00002
FEED WATER SYSTEM (2/2)

TT2-311-M103-00003 (I-8)
TO MAIN STEAM DRAIN POT

TT2-311-M103-00001 (I-7)

AA003

PRV
-

20QJB42
BR001 HB1
DN 25

20QJB10
BR001 HB1
DN 50
20QJB10

TO LP FWH 2 SHELL SIDE

TT2-313-M103-00002 (F-10)

20QJB11
BR001 HB1
DN 50

PI
-

20QJB34
BR001 HB1
DN 25

AA001

20QJB12
BR001 HB1
DN 50

TI

20QJB51
BR001 HB1
DN 25

( Owner's Scope of Supply )

TO LP FWH 1 TUBE SIDE

TT2-320-M103-00003 (H-9)
TO GLAND STEAM CONDENSER
SHELL SIDE

20QJB33
BR001 HB1
DN 25

TO GLAND STEAM CONDENSER


TUBE SIDE

20QJB32
BR001 HB1
DN 25

20QJB12
AA001

TT2-320-M103-00002 (K-8)

20QJB41
BR001 HB1
DN 25

TO LP FWH 3 SHELL SIDE

20QJB31
BR001 HB1
DN 25

TO DEAERATOR

20QJB38
BR001 HB1
DN 25

TO HP FWH 5 SHELL SIDE

20QJB53
BR001 HB1
DN 25

TO LP FWH 3 TUBE SIDE

20QJB37
BR001 HB1
DN 25

TO HP FWH 5 TUBE SIDE

20QJB61
BR001 HB1
DN 25

TO BOILER STEAM DRUM

20QJB62
BR001 HB1
DN 25

TO BOILER PRYMARY SH

TT2-313-M103-00002 (A-10)

TT2-313-M103-00001 (E-10)

TT2-320-M103-00003 (H-2)

TT2-330-M103-00002 (G-9)

TT2-BLR-J-161-00084 (M-11)

TT2-BLR-J-161-00085 (H-14)

TO BOILER PLATEN SH INLET


HEADER

TT2-BLR-J-161-00085 (I-12)

FOR CONSTRUCTION

TO BOILER PLATEN SH OUTLET


HEADER

20QJB64
BR001 HB1
DN 25

TT2-BLR-J-161-00085 (D-9)

TO BOILER SECONDARY SH
OUTLET HEADER

20QJB65
BR001 HB1
DN 25

10

TT2-314-M103-00003 (H-8)

20QJB63
BR001 HB1
DN 25

2. VENDOR DWG.
TURBINE SUPPLIER DWG.
- TT2-STG-M103-00010-3
STEAM WATER (3/4)
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00084
BOILER WATER FLOW
- TT2 - BLR - J - 161 - 00085
STEAM FLOW (1/2)
- TT2 - BLR - J - 161 - 00099
STEAM FLOW (2/2)

TT2-STG-M103-00010-3 (C-3)

TT2-BLR-J-161-00099 (I-17)

26.MAR.'14

FOR CONSTRUCTION

Y.M.KIM

C.H.JANG

S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

08.JUL.'13

FOR CONSTRUCTION

W.S.CHO C.H.JANG

S.H.KIM

REV.

DATE

DRWN

APPD

DESCRIPTION

CHKD

10

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11

N2 CYLINDERS RACK

PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

W.S.CHO

26.MAR.'14

C.H.JANG

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

P&I DIAGRAM
N2 FILLING SYSTEM

26.MAR.'14

APPROVED BY

12

TITLE:

DATE

CHECKED BY

DATE

S.H.KIM

12

26.MAR.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-923-M103-00001
O

REV.

2
A1(841x594m/m)

DWG.NO

TT2-931-M103-00001

LEGEND
EGD : PIPING SYSTEM

NOTES
1. THE QUANTITY AND LOCATION OF DRAIN AND
VENT POINT ARE SUBJECT TO PHYSICAL PIPING
LAYOUT.

REFERENCE DRAWINGS
1. P&I DIAGRAMS

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00096
IGNITER OIL HEADER SYSTEM

FE
21EGD10CF001

21EGD10
BR001 GB1
DN 50

FROM OWNER'S FUEL OIL PUMP

21EGD10
AA001

TO BOILER IGNITER OIL HEADER


SYSTEM

21EGD10
AA002

TT2-BLR-J-161-00096 (E22)

21EGD10
AA003

FOR CONSTRUCTION

10

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

DRWN

CHKD

10

APPD

EMPLOYER:

Termotasajero Dos S.A. E.S.P


CONTRACTOR:

11

11
PROJECT:

Termotasajero 2 161.6MW CFPP


DRAWN BY

DATE

B.S.KIM

15.OCT.'14

CHECKED BY
Y.W.SEONG

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.
A

P&I DIAGRAM
IGNITOR FUEL OIL SYSTEM

15.OCT.'14

APPROVED BY

12

TITLE:

DATE
DATE

S.H.KIM

12

15.OCT.'14

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-931-M103-00001
O

REV.

1
A1(841x594m/m)

TT2-142-M103-00001

DWG.NO

TT2-BLR-J-161-00099 (I-3)

NOTES

21LCQ79
BR501 GA1
DN 25

1. THE QUANTITY AND LOCATION OF DRAIN AND VENT


POINT ARE SUBJECT TO PHYSICAL PIPING LAYOUT.
2. THIS ANGLE VALVE SHALL BE INCHING TYPE MOV.
3. LEVEL CONTROL VALVE STATION SHALL BE LOCATED
NEAR THE CONDENSER.
4. TEMPERUTURE TRANSMITTER SHALL BE INSTALLED
NEAR THE BOILER BLOWDOWN SUMP PIT.

DN25

21LBG51
AA501

21HLC51
AA502

DN 40
BR001 HB1
21HLC51

21LBG51
AA014

DN 80
BR005 HB1
21LBG51

DN 80
BR003 HB1
21LBG51

TT2-913-M103-00003 (H-7)

21HLC21
AA012

PI
21HLC10CP501

TI
21HLC11CT501

PDIS
21HLC11CP201
21HLC11
AT001

21HLC11
AA301

21HLC10
AA302

F1

D2

21HLC11
AA001

DN 25

LG
21HLC10CL501

21HLC10
AA316

21HLC12
BR001 HB1
DN 100

21HLC10
AP001
PDA+
-

21HLC22
BR001 HB1
DN 50

PI
21HLC20CP501

21HLC12
AT001

20.JAN.'15

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

15.OCT.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

26.MAR.'14

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

31.JUL.'13

FOR CONSTRUCTION

B.S.KIM Y.W.SEONG S.H.KIM

REV.

DATE

DESCRIPTION

CHKD

APPD

TI
21HLC12CT501

11
PROJECT:

Termotasajero 2 161.6MW CFPP

21HLC12
AA001

DRAWN BY

DATE

B.S.KIM

20.JAN.'15

Y.W.SEONG

P&I DIAGRAM
BLOW DOWN SYSTEM

20.JAN.'15

APPROVED BY

THIS DOCUMENT OR DRAWING IS THE PROPERTY OF HYUNDAI ENGINEERING.


ANY REPRODUCTION OR DISTRIBUTION OF THE MATERIALS WITHOUT PERMISSION
OF HYUNDAI ENGINEERING WILL BE STRONGLY PROHIBITED.

TITLE:

DATE

CHECKED BY

DRWN

10

Termotasajero Dos S.A. E.S.P

80 x 50

FOR CONSTRUCTION

EMPLOYER:

21HLC20
AP001

CONTRACTOR:

PDIS
21HLC12CP201
21HLC12
AA302

21HLC22
AA001

PI
21HLC20CP502

21HLC10
AA315

*
F2

21HLC10
AA401

21HLC10
AA301

21HLC41
BR001 HB1
DN 80

21HLC10
AA314

(2 X 100%)

21HLC10
AA313
LT
21HLC10CL101B

DN25

S.C.A.H DRAIN TRANSFER PUMP

LI
-

D1

80 x 50

DN25

TO BOILER BLOW DOWN SUMP

DN25

S.C.A.H DRAIN TANK


21HLC10
BB001

21HLC10
AA402

21HLC40
AA002
21HLC40 21HLC40
AA003
BR003 HB1

21HLC40
AA004

TT2-BLR-J-161-00084 (A-11)

FROM DOWNCOMER MANIFOLD

TT2-BLR-J-161-00084 (A-7)

TT2-BLR-J-161-00084 (A-13)

FROM RH DOWNCOMER

TT2-BLR-J-161-00099 (H-3)

21LCQ22
BR401 GA1
DN 40
21LCQ51
BR401 GB1
DN 65
21LCQ53
BR401 GB1
DN 65
21LCQ52
BR401 GB1
DN 65

FROM LH DOWNCOMER

TT2-BLR-J-161-00099 (H-7)

FROM REHEAT OUTLET


HEADER

TT2-BLR-J-161-00099 (G-17)

FROM REHEAT INLET HEADER

FROM SECONDARY SH OUTLET


HEADER

21LCQ24
BR401 EA1
DN 40
21LCQ23
BR401 EB1
DN 40

TT2-BLR-J-161-00099 (C-20)

21LCQ25
BR401 EA1
DN 25

21LBG51
AA012
21LBG51
AA013

21LBG51
BR002 HB1
DN 80
21HLC21
AA401
E

DN 150
BR002 HD2
21LCQ43

21HLC22
AA401

NOTE 4

AG
UG
D

21HLC22
AA002

PDA+
-

PI
21HLC10CP502

DN25

21HLC21
AA311

21LCQ43
BR001 HB2
DN 150
TT
21LCQ43CT151

12

TI
-

11

DN 40

21HLC10
AA312

21HLC21
AA001

21HLC21
AA801

I2
E2

PSV
21HLC10AA101

LT
21HLC10CL101A

21HLC20
AA302

BS

21HLC21
AA003

21HLC21
AA002

DN25

21HLC21
AA004

21HLC21
AA501

21HLC21
BR001 HB1
DN 50

BS

WS

21HLC21
AA402

TT2-320-M103-00001 (B-7)

21HLC21
BR003 HB1
DN 80

DN25

PT
21HLC21CP101

I1

DN 25
BR002 HB1
21HLC21

21HLC21
AA011

MAINTENANCE
DRAIN

LCV
21HLC21AA041

TO CONDENSER

21HLC10
AA311

LI
-

RO
21HLC21BP001
21HLC22
AA011

PI
-

10

21HLC40 21HLC40
BR001 HB1 AA001
DN 40

DN25

RO
21HLC22BP001

20GHA09
AA801

NOTE 3

FROM SECONDARY SH INLET


HEADER

TT2-BLR-J-161-00085 (B-11)

21LCQ26
BR104 EA1
DN 40

FROM PLATEN SH INLET


HEADER

TT2-BLR-J-161-00085 (G-14)

FROM CW INLET BOTTLE

TT2-BLR-J-161-00085 (D-15)

FROM HCP RHSW LOWER


HEADER

21LCQ28
BR401 EB1
DN 50
21LCQ27
BR401 EA1
DN 40

TT2-BLR-J-161-00085 (C-15)

FROM HCP LHSW LOWER


HEADER

21LCQ29
BR401 EB1
DN 50

TT2-BLR-J-161-00084 (A-8)

21LCQ34
BR401 EB2
DN 65

FROM BOILER DOWNCOMER


BLOWOFF

TT2-BLR-J-161-00084 (L-18)

FROM FEED WATER LINE

TT2-162-J103-00003 (G-2)

21HLC22
BR002 HB1
DN 25

20GHA09
AA004

20GHA09
AA401

20GHA09
AA003

E1

21HLC22
AA012

TCV
20GHA09AA472

TT2-919-M103-00001 (N-11)

21LCQ42
BR001 HB2
DN 40

PI
21HLC10CP503

21HLC11
AA302

DN 20
G

21LCQ41
AA001

*
*

21HLC10
AA303

C2

20GHA09
BR001 HB2
DN 100

PI
21LCQ10CP501

21HLC20
AA301

21LCQ10
AA004

FROM SERVICE WATER

*
21LCQ10
AA301

COMMON DRAIN HEADER

STEAM COIL AIR HEATER

DN 50

C1

TI
21LCQ10CT501

2. VENDOR DWG.
BOILER SUPPLIER DWG.
- TT2 - BLR - J - 161 - 00084
BOILER WATER FLOW
- TT2 - BLR - J - 161 - 00085
STEAM FLOW (1/2)
- TT2 - BLR - J - 161 - 00099
STEAM FLOW (2/2)

21HLC11
BR001 HB1
DN 100

21LCQ10
AA003
LG
21LCQ10CL501

BOILER BLOW DOWN TANK


21LCQ10
H
BB001
DN 20

DN 40
BR002 HB1
21HLC40

DN 50

DN 25

21LCQ41
BR001 HB2
DN 80

A2

21LCQ42
AA001

21LCQ20
BR001 HB1
DN 250

A1

21LCQ30
BR001 HB1
DN 100

A3

20QUW10 20QUW10
AA402
AA401

DN 40

SOOTBLOWER DRAIN HEADER

20QUW10
BR401 BB1
DN 25
21LCQ35
BR401 EB1
DN 50

21LCQ41
BR002 HB2
DN 25

21LCQ33
BR401 HB1
DN 50

21LCQ32
BR401 HB1
DN 50

21LCQ31
BR401 HB1
DN 50

FROM SAMPLING BLOWDOWN


HEADER

21LCQ70
BR501 HB2
DN 450

21LCQ10
AA002

21LBG51
AA011

IN

NOTE 2

21LCQ10
AA005

DN 40
BR002 BB1
21LCQ10

21HLC12
AA301

21LCQ10
BR003 BB1
DN 40

TT2-BLR-J-161-00100 (H-2)

FROM AIR HEATER S/B STEAM


LINE

TT2-BLR-J-161-00100 (C-9)

FROM BOILER S/B LHSW


STEAM LINE

TT2-BLR-J-161-00086 (C-22)

TT2-BLR-J-161-00084 (H-15)

FROM BOILER S/B RHSW


STEAM LINE

21LCQ10
AA001

1. P&I DIAGRAMS
- TT2 - 919 - M103 - 00001
SERVICE WATER DISTRIBUTION SYSTEM
- TT2 - 913 -M103 - 00003
WASTE WATER TRANSFER SYSTEM (3/3)

DN 40

21LBG51
BR001 HB1
DN 150

MOV
21LCQ10AA041

MOV
21LBG51AA041

21LBG51
BR004 HB1
DN 80

COMMON VENTS HEADER

TT2-318-M103-00001 (N-2)

21LCQ10
BR001 BB1
DN 40

REFERENCE DRAWINGS
PI
21LBG51CP501

FROM AUX. STEAM HEADER

FROM BOILER STEAM DRUM

DN 40
BR004 HB1
21HLC40

TT2-BLR-J-161-00099 (I-7)

FROM REHEAT OUTLET


HEADER

FROM REHEAT INLET HEADER

21LCQ78
BR501 GB1
DN 25

TT2-BLR-J-161-00099 (H-17)

FROM SECONDARY SH OUTLET


HEADER

21LCQ77
BR501 EA1
DN 25

TT2-BLR-J-161-00085 (G-9)

TT2-BLR-J-161-00085 (J-11)

- LCQ : STEAM GENERATOR BLOWDOWN SYSTEM


- HAH : SUPERHEATER SYSTEM
- HAJ : REHEATER SYSTEM

21LBG51
AA301

FROM PLATEN SH OUTLET


HEADER

FROM PLATEN SH INLET


HEADER

FROM PRIMARY SH OUTLET


LINE

21LCQ71
BR501 HB2
DN 200

21LCQ76
BR501 EA1
DN 25

21LCQ70
BR502 HB2
DN 450

21LCQ70
BR451 HB2
DN 25

21LCQ75
BR501 EA1
DN 25

21LCQ74
BR501 EA1
DN 25

SILENCER FOR
BOILER BLOWDOWN TANK
21LCQ10
BS001

TT2-BLR-J-161-00085 (G-15)

LEGEND
1

DATE

S.H.KIM

12

20.JAN.'15

HD CLASSIFICATION NO.

SCALE

JOB NO.

DRAWING NUMBER

TT2-142-M103-00001
O

REV.

3
A1(841x594m/m)

Potrebbero piacerti anche