Sei sulla pagina 1di 1

16 MM @ 200 C/C

+ 12 MM @ 200 C/C

10 MM @ 200 C/C

700

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

300

200

7500 I/S

25 MM @ 200 C/C
+ 12 MM @ 200 C/C

200

EL +0.300

150x150x12 THK.
INSERT PLATE

12 MM @ 120 C/C
B/F HORZ. BARS.

EL -1.170

2600

1110

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

EL +0.300

200

150x150x12 THK.
INSERT PLATE
200

300

650

1200

25 MM @ 200 C/C
+12 MM @ 200 C/C

700

4000 I/S

2600

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

925

200

B3

10 MM @ 200 C/C
BOTH FACE
VERT. BARS

10 MM @ 200 C/C
BOTH FACE VERT. BARS
20 MM @ 240 C/C

B3

20 MM @ 150 C/C

20 MM @ 230 C/C
+12 MM @ 230 C/C

20 MM @ 240 C/C
20 MM @ 240 C/C
+12 MM @ 240 C/C

EL -1.800

10 MM @ 200 C/C

25 MM @ 200 C/C

16 MM @ 200 C/C
+12 MM @ 200 C/C
B/F HORZ. BARS.

2000

300

2500

16 MM @ 200 C/C
+12 MM @ 200 C/C
B/F HORZ. BARS.

400
250

400
100 TH. P.C.C.- 1:4:8

16 MM @ 150 C/C

PLAN BETWEEN -6.200M TO -4.200M OF WALL


400
150

400
150

150

2000 I/S

10 MM @ 250 C/C

2000 I/S

300

300

400

2500 I/S

7900 O/O

500

SECTION AT 'B-B'

500

150

SECTION AT 'A-A'

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

400x325

3600

400x325

EL +0.300

25 MM @ 200 C/C
+ 12 MM @ 200 C/C

500

1110

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

16 MM @ 150 C/C

500

EL -6.200

100 TH. P.C.C.- 1:4:8

400

4400 O/O

500

25 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

10 MM @ 200 C/C

700

B2

20MM@150C/C
B/F HORZ. BARS

EL -6.550

10 MM @ 250 C/C

3600 I/S

B
275

300

650

1200

25 MM @ 200 C/C
+12 MM @ 200 C/C

700

20MM@150C/C
B/F HORZ. BARS

400
EL -6.550

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

25 MM @ 200 C/C
+12 MM @ 200 C/C

OIL SEPARATOR

25 MM @ 200 C/C
+12 MM @ 200 C/C

25 MM @ 200 C/C

10 MM @ 200 C/C
B/F VERT. BARS

EL -6.200

7900

925

2000

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

EL -4.200
MIN WATER LVL

CLEAN WATER

C1(325X775).

C1(325X775).

4-16 MM (I/S) +
4-16 MM (O/S)
MAIN BARS

300

400

2500

4-16 MM (I/S) +
4-16 MM (O/S)
MAIN BARS

PLAN BETWEEN -4.200M TO -2.300M OF WALL

775

250
925

10 MM @ 200 C/C

700

16 MM @ 150 C/C

775

1110

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

150

10 MM @ 250 C/C

5150 O/O

500

500

10 MM @ 200C/C

25 MM @ 200 C/C

900

2650

C
PLAN AT TOP LEVEL

SECTION AT 'C-C'
(AT COLUMNS C1)

25 MM @ 200 C/C
+ 12 MM @ 200 C/C

200

2 -12 MM
TOP

4 -12 MM

B3

B2

200

C/L OF TANK

C1
4 - 16 MM

VARY FROM
400 TO 775

10 MM @ 200 C/C

25 MM @ 200 C/C

8 MM STPS.
@ 200 C/C
8 MM STPS.
@ 200 C/C

3 -12 MM
BOTTOM.
FROM MACHINE

VARY FROM
200 TO 400

650

25 MM @ 200 C/C
+ 12 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

DETAILS OF COLUMN - C1
275

1110

1200

25 MM @ 200 C/C
+12 MM @ 200 C/C

1300

400

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

2000

300

10 MM @ 200C/C

2000

300

REVISION NOTES:
MINOR DIMENSION ERRORS RECTIFIED

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

2500

NEAT CEMENT
FINISH

B2

400

3 - 12 MM
BOTTOM.
OPENING
(600 X 400 )

EL -2.100

10 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

200

2 - 12 MM
TOP.

25 MM @ 200 C/C

25 MM @ 200 C/C
+12 MM @ 200 C/C

400

150

= 4000 =

OPENING
(600 X 400)

1400

PLAN AT BASE SLAB

775

3600

8 MM @ 250 C/C
STIRRUPS

300 600 300

25 MM @ 200 C/C
+12 MM @ 200 C/C

2150

2500

20 MM @ 150 C/C

25 MM @ 200 C/C

2000

100 TH. P.C.C.- 1:4:8

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

275

300

650

1200

25 MM @ 200 C/C
+12 MM @ 200 C/C

700

500 400

C1(325X775).

EL -6.550

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

2000
EL -6.200

775

C1(325X775).

500

2000

7900

250

2000

400

300

EL -4.200
MIN WATER LVL

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

550

2000

10 MM @ 200C/C

200

400

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

400

1300

8 MM @ 250 C/C
STIRRUPS

250

650

25 MM @ 200 C/C
+ 12 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

275

25 MM @ 200 C/C
+12 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

6500
1900

1110

10 MM @ 200 C/C

4000 I/S

EL -2.300
MAX PIT FILL LVL

4200 C/C

10 MM @ 200 C/C

25 MM @ 200 C/C

OVERFLOW
PIPE

325

25 MM @ 200 C/C

900

= 3600 I/S=

10 MM @ 200C/C

C/L OF TANK
B2

1400

= 4400 O/O =

OPENING
(600 X 400)

25 MM @ 200 C/C

25 MM @ 200 C/C
+12 MM @ 200 C/C

2600

25 MM @ 200 C/C
+12 MM @ 200 C/C

= 4000 =

25 MM @ 200 C/C

300 600 300

400

20 MM @ 150 C/C

20 NOS. 150x150x12THK. INSERT PLATE


TO BE PROVIDED AT TOP OF WALL FOR
HAND RAILING

200

300

10 MM @ 200C/C

25 MM @ 250 C/C

25 MM @ 250 C/C
+12 MM @ 250 C/C

10 MM @ 200 C/C
B/F VERT. BARS

SCALE PIT

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

2000

16MM @150 C/C


B/F HORZ. BARS

400
150

400

10 MM @ 200 C/C B/F VERT. BARS

2000

1300

25 MM @ 250 C/C
+12 MM @ 250 C/C

25 MM @ 250 C/C

EL -4.200
MIN WATER LVL

25 MM @ 200 C/C
+ 12 MM @ 200 C/C

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

16MM @150 C/C


B/F HORZ. BARS

3900

16 MM @ 200 C/C
+ 12 MM @ 200 C/C

650

10 MM @ 200 C/C B/F VERT. BARS

200

1200

25 MM @ 200 C/C
+12 MM @ 200 C/C

1110

10 MM @ 200 C/C

EL -2.300
MAX PIT FILL LVL

4400

1900

25 MM @ 200 C/C

C/L OF TANK
B2

6500

10 MM @ 200C/C

25 MM @ 200 C/C
+12 MM @ 200 C/C

EL -2.300

250

OPENING
(600 X 400)

6500
1900

25 MM @ 200 C/C
+12 MM @ 200 C/C

EL -2.300
MAX PIT FILL LVL

25 MM @ 200 C/C

= 4000 =

25 MM @ 200 C/C

300 600 300

EL -2.100

400

7900

B
REFERENCE NOTES:
REFER CIL DWG NO. 04-12-006.3 / 0412006A
THIS DWG IS MODIFIED FOR BETTER PLANT
OPERATIONAL EFFICIENCY. REFER ALL
RELATED DWGS BY CIL FOR EXECUTION.

DETAILS OF B3

EL -6.200

DETAILS OF B2

CONSTRUCTIONS NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
(a)
(c)
9.
10.

ALL DIMENSIONS ARE IN MILLIMETERS AND ALL LEVELS ARE IN METERS.


DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED.
USE M20 GRADE OF CONCRETE FOR ALL R.C.C.
FOR ALL REINFORCEMENT BARS,USE TOR STEEL (HIGH YIELD STRENGTH DEFORMED BARS) CONFORMING TO IS 1786 (Fe 415).
OVERLAP LENGTH OF BARS = 47 X DIA.OF BARS.
USE PLASTICISER AND BUILDING CHEMICAL OF APPROVED MAKE FOR OLD CONC./ NEW CONC. BONDING.
INSIDE SURFACE OF TANK WILL BE IN NEAT CEMENT FINISH .
CLEAR COVER TO REINFORCEMENT :WALL = 25 MM. (b) BASE SLAB = 40 MM
COUNTER-FORT/COLUMN = 40 MM(d)BEAMS = 25MM
PROVIDE FOUNDATION BOLTS /INSERTS /CURB ANGLES AS PER REQUIREMENT.
HOOKE LENGTH FOR STIRRUPS :-2 X 10 X DIA. OF STIRRUPS.

INDUSTRIAL CADD SERVICES


RAIPUR - 88718-40714, 98275-92410

GENERAL NOTES:
1.
2.

ALL DIMENSIONS,LEVELS AND ORIENTATION SHALL BE APPROVED BY PROCESS CONSULTANT BEFORE EXECUTION.
THIS DRG.SHOULD BE STUDIED CAREFULLY AND DISCREPANCY IF ANY,SHALL BE BROUGHT TO THE NOTICE BEFORE EXECUTION.

AE/MGCPL/RSPL/CCM/16/C-SP/01

01

Potrebbero piacerti anche