Sei sulla pagina 1di 30

SMA 1/4 EX

(OMS 1260)

2005. The Copyright in this document belongs to Marconi Corporation plc and
no part of this document should be used or copied without their prior written permission.

www.marconi.com

The SMA 1/4 EX (OMS 1260)

SMA1/4EX
Full capacity Multi Service Network
edge node STM-1/STM-4

4 Line I/F + 5 Generic Tribs


6 x STM-4
18 x STM-1
5 x 34 or 45Mbit/s PDH
5 x 140Mbit/s PDH
252 x 2Mbit/s PDH

SMA1/4 EX
63 x 2M LTU Positions. Providing access to the
Four 2 M Trib Cards

Power and LCT I/F

Protection Power and LCT I/F


Position
Core CCU/Switch Card
Two SFP module positions
STM-1, STM-4 Optical
STM-1 Electrical

Auxiliary Unit Providing


Two x Ext Timing I/P (T3)
Two x Ext Timing O/P (T4)
Qx Network Management I/F
2M PDH Traffic Test Port
Bw7R Alarm Indication
Four Ext User Alarm O/P
Six Ext User Alam I/P

Protection 63 x 2M
Trib Card
Protection Core Switch
Card
Two SFP module positions
STM-1, STM-4 Optical
STM-1 electrical

Fan Tray

Fan Tray
Four 63 x 2M Trib card Positions Mutually
exclusive with equipping of adjacent Generic Trib
slot
3

SMA1/4 EX
Five Generic LTUs Provide Power for and access to the Generic
Tributary slot positions
Power and LCT I/F
Protection Power and
LCT I/F Position
Five Generic Trib card Positions
Slots 1 - 3 = 2 x VC-4 Bandwidth
Slots 4 - 5 = 4 x VC-4 Bandwidth

Data
SDH
PDH

SMA1/4 EX

OMS 1260 (EX) ETSI Rack & Subrack


Bay Face Layout

Rack Alarm Unit


Breaker Dist
Panel

OFF
ON

OFF
ON

ON

ON

ON

ON

ON

79
76

Screw position for


mounting breaker
distribution panel

ETSI Rack

18
10

Screw position
for mounting
SMA1/4 EX subrack

DC Breaker Distribution Panel- 1/4 EX


(2)

Main Power
Source 1

(3)

1/4 EX
Power 2

Rack
Alarm
1/4 EX
Power 1

Main Power
Source 2
(6)

63A
-VE

(4)

63A
+VE

63A
-VE

63A
+VE

6A

(5)

10A

Items Description
(1)
(2)
(3)
(4)
(5)
(6)

Rack Mounted Breaker Distribution Board


Power Cable 16 Sqmm (Main) , Red
Power Cable 16 Sqmm (Main), Blue
Magnethothermic Breaker (MCB) , 6A
Magnethothermic Breaker (MCB) , 10A
Magnethothermic Breaker (MCB) , 63A

(490/IM0001BD/22)
(490/IM0002/22)
(490/IM0002/21)
(490/IM0001BD/23)
(490/IM0001BD/24)
(490/IM0001BD/26)

10 A

(1)

Rack Alarm Unit Power Supply


Rack

Alarm Unit Power Connection

EX Subrack Dimensions
SMA_EX

Height 445 mm
Width 448 mm
Depth 280mm

10
Slide-in Fan Unit
SFP I/F

2Mb Trib LTU 3a (ports 1-21)

Generic Trib 2 PSU/LTU

2Mb Trib LTU 2c (ports 43-63)

SFP I/F

Slide-in Fan Unit

Generic Trib 5 PSU/LTU

Generic Trib 4 PSU/LTU

2Mb Trib LTU 4c (ports 43-63)

2Mb Trib LTU 4b (ports 22-42)

2Mb Trib LTU 4a (ports 1-21)

Generic Trib 3 PSU/LTU

2Mb Trib LTU 3c (ports 43-63)

2Mb Trib LTU 3b (ports 22-42)

(Expansion) Generic Trib 7

Generic Trib 7 PSU/LTU

(Expansion) Generic Trib 6 Generic Trib 6 PSU/LTU

Generic Trib 5

Generic Trib 4

63x 2Mb Trib 4

Generic Trib 3

63x 2Mb Trib 3

SFP I/F

UC STM-1/4 Traffic Core A / CCU

SFP I/F

UC STM-1/4 Traffic Core B

2Mb Trib LTU 2b (ports 22-42)

2Mb Trib LTU 2a (ports 1-21)

Generic Trib 1 PSU/LTU

2M PDH Trib 1
LTU area
(63-ports)

63x 2Mb Protn Trib

Generic Trib 2

63x 2Mb Trib 2

2Mb Trib LTU 1c (ports 43-63)

2Mb Trib LTU 1b (ports 22-42)

2Mb Trib LTU 1a (ports 1-21)

63x 2Mb Trib 1


Generic Trib 1

Port Access Area

Functional Unit Card Cage

SMA-1/4 EX SUBRACKs with 252x 2M PDH Balanced


Access LTUs
2M Balanced LTUs
21 ports per LTU 12 LTUs max per Subrack (252 x 2M)
2M PDH Trib 2
LTU area
(63-ports)

11
Slide-in Fan Unit
SFP I/F
2Mb Trib LTU 3a (ports 1-21)

Generic Trib 2 PSU/LTU

SFP I/F

Slide-in Fan Unit

(Expansion) Generic Trib 7

Generic Trib 7 PSU/LTU

(Expansion) Generic Trib 6 Generic Trib 6 PSU/LTU

TRIB CARD 3 63x2M


PDH
(Unbalanced)
LTU Front Plate
Generic Trib 5 PSU/LTU

TRIB CARD 1 63x2M


PDH
(Unbalanced)
LTU Front Plate

Generic Trib 4 PSU/LTU

2Mbit Trib LTU 3


(Ports 1 63)

Generic Trib 5

2Mb Trib LTU 4c (ports 43-63)

2Mb Trib LTU 4b (ports 22-42)

2Mb Trib LTU 4a (ports 1-21)

Generic Trib 3 PSU/LTU

2Mb Trib LTU 3c (ports 43-63)

2Mbit Trib LTU 1


(Ports 1 63)

Generic Trib 4

63x 2Mb Trib 4

Generic Trib 3

63x 2Mb Trib 3

SFP I/F

2Mb Trib LTU 3b (ports 22-42)

UC STM-1/4 Traffic Core A / CCU

SFP I/F

2Mb Trib LTU 2c (ports 43-63)

2Mb Trib LTU 2b (ports 22-42)

2Mb Trib LTU 2a (ports 1-21)

Generic Trib 1 PSU/LTU

2Mb Trib LTU 1c (ports 43-63)

UC STM-1/4 Traffic Core B

63x 2Mb Protn Trib

Generic Trib 2

63x 2Mb Trib 2

2Mb Trib LTU 1b (ports 22-42)

2Mb Trib LTU 1a (ports 1-21)

63x 2Mb Trib 1


Generic Trib 1

Port Access Area

Functional Unit Card Cage

SMA1/4 EX Subracks Limited 126 x 2M PDH access via in


shelf LTU to Trib Slots 1 & 3

63 Port Unbalanced LTUs using front-plate PCB


& 1.0/2.3 CO -AX connectors provides access to
2M Trib slots 1 & 3 (126 2M)

Access blocked to 2M Trib slots 2 & 4 and


Generic Trib slots 1 & 3

Equipment Layout
1

2
3

4
5
6

12

1.

63x2Mb/s LTU

2.

Generic LTU

3.

Power LTU

4.

STM-1/4 CoreCard

5.

Generic Trib

6.

Aux/Sync./Ancillary LTU

7.

Fan Tray/Blanking late

Rack Mounting

13

Slot Configuration and Numbers

14

Card Area

Slot Bandwidth [STM-1]

15
Trib
Group
1

Trib
Group
2

2
3

FAN Tray 1
01 02 03 04 05
06
2
2
07

Trib
Group
3
Trib
Group
4

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21

S3 12 Generic Trib 3 PSU/LTU

S3 11 2M LTU 3C

S3 10 2M LTU 3B

S3 09 2M LTU 3A

S3 08 Generic Trib 2 PSU/LTU

S3 07 2M LTU 2C

S3 06 2M LTU 2B

S3 05 2M LTU 2A

S3 04 Generic Trib 1 PSU/LTU

S3 03 2M LTU 1C

S3 02 2M LTU 1B

2
3

FAN Tray 2
08 09 10 11 12 13 14
2
4
4 4 4

Unit

15

S3 21 Power & LCT LTU

S3 20 Power & LCT LTU

S3 19 Generic Trib 7 PSU/LTU

S3 18 Generic Trib 6 PSU/LTU

S1_14 Generic Trib 7


S1_15 Comms/Aux/Ancilliary

S3 17 Generic Trib 5 PSU/LTU

S1_13 Generic Trib 6

S3 16 Generic Trib 4 PSU/LTU

S3 15 2M LTU 4C

1
1

S1_12 Generic Trib 5

S1_11 Generic Trib 4

S3 14 2M LTU 4B

2M LTU Connectivity:
S3 13 2M LTU 4A

S1_10 2M Trib 4

S1_09 Generic Trib 3

S1_08 2M Trib 3

[blank]

S1_07 Traffic Core A /CCU

S1_06 Traffic Core B

S1_05 2M Protection Trib

- 63x2M, unbalanced

S1_04 Generic Trib 2

S1_03 2M Trib 2

S1_02 Generic Trib 1

- 21x2M, balanced
S3 01 2M LTU 1A

LTU Area

S1_01 2M Trib 1

Slot Configuration and Numbers

Switch functions
Line Units
Timing Functions
Mux. Controller and
Communications functions

16
Trib
Group
1
Trib
Group
2

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
S3 12 Generic Trib 3 PSU/LTU

S3 11 2M LTU 3C

S3 10 2M LTU 3B

S3 09 2M LTU 3A

S3 08 Generic Trib 2 PSU/LTU

S3 07 2M LTU 2C

S3 06 2M LTU 2B

S3 05 2M LTU 2A

S3 04 Generic Trib 1 PSU/LTU

S3 03 2M LTU 1C

S3 02 2M LTU 1B

S3 01 2M LTU 1A

2
3

Trib
Group
3

S3 21 Power & LCT LTU

S3 20 Power & LCT LTU

S3 19 Generic Trib 7 PSU/LTU

S3 18 Generic Trib 6 PSU/LTU

S1_14 Generic Trib 7


S1_15 Comms/Aux/Ancilliary
Unit

S3 17 Generic Trib 5 PSU/LTU

Trib
Group
4

S1_13 Generic Trib 6

S3 16 Generic Trib 4 PSU/LTU

S3 15 2M LTU 4C
1

S3 14 2M LTU 4B

1
1

S1_12 Generic Trib 5

S3 13 2M LTU 4A

S1_11 Generic Trib 4

S1_10 2M Trib 4

S1_09 Generic Trib 3

S1_08 2M Trib 3

[blank]

2
S1_07 Traffic Core A /CCU

S1_06 Traffic Core B

S1_05 2M Protection Trib

S1_04 Generic Trib 2

S1_03 2M Trib 2

S1_02 Generic Trib 1

Comprises :-

S1_01 2M Trib 1

SMA 1/4EX Core/CCU ADM Unit, Core A (slot 1_7)

Comprises :-

Switch functions
Line Units
Timing Functions

17
Trib
Group
1
Trib
Group
2

S3 12 Generic Trib 3 PSU/LTU

S3 11 2M LTU 3C

S3 10 2M LTU 3B

S3 09 2M LTU 3A

S3 08 Generic Trib 2 PSU/LTU

S3 07 2M LTU 2C

S3 06 2M LTU 2B

S3 05 2M LTU 2A

S3 04 Generic Trib 1 PSU/LTU

S3 03 2M LTU 1C

S3 02 2M LTU 1B

S3 01 2M LTU 1A

2
3

Trib
Group
3
Trib
Group
4

Unit

S3 21 Power & LCT LTU

S3 20 Power & LCT LTU

S3 19 Generic Trib 7 PSU/LTU

S3 18 Generic Trib 6 PSU/LTU

S1_14 Generic Trib 7


S1_15 Comms/Aux/Ancilliary

S3 17 Generic Trib 5 PSU/LTU

S1_13 Generic Trib 6

S3 16 Generic Trib 4 PSU/LTU

S3 15 2M LTU 4C
1

S3 14 2M LTU 4B

1
1

S1_12 Generic Trib 5

S3 13 2M LTU 4A

S1_11 Generic Trib 4

S1_10 2M Trib 4

S1_09 Generic Trib 3

S1_08 2M Trib 3

[blank]

2
S1_07 Traffic Core A /CCU

S1_06 Traffic Core B

S1_05 2M Protection Trib

S1_04 Generic Trib 2

S1_03 2M Trib 2

S1_02 Generic Trib 1

S1_01 2M Trib 1

SMA 1/4EX Core Protection ADM Unit, Core B (Slot 1_6)

18
Trib
Group
1
Trib
Group
2

S3 12 Generic Trib 3 PSU/LTU

S3 11 2M LTU 3C

S3 10 2M LTU 3B

S3 09 2M LTU 3A

S3 08 Generic Trib 2 PSU/LTU

S3 07 2M LTU 2C

S3 06 2M LTU 2B

S3 05 2M LTU 2A

S3 04 Generic Trib 1 PSU/LTU

S3 03 2M LTU 1C

S3 02 2M LTU 1B

S3 01 2M LTU 1A

2
3

Trib
Group
3
Trib
Group
4

Unit

S3 21 Power & LCT LTU

S3 20 Power & LCT LTU

S3 19 Generic Trib 7 PSU/LTU

S3 18 Generic Trib 6 PSU/LTU

S1_14 Generic Trib 7


S1_15 Comms/Aux/Ancilliary

S3 17 Generic Trib 5 PSU/LTU

S1_13 Generic Trib 6

S3 16 Generic Trib 4 PSU/LTU

S3 15 2M LTU 4C
1

S3 14 2M LTU 4B

1
1

S1_12 Generic Trib 5

S3 13 2M LTU 4A

S1_11 Generic Trib 4

S1_10 2M Trib 4

S1_09 Generic Trib 3

S1_08 2M Trib 3

[blank]

2
S1_07 Traffic Core A /CCU

S1_06 Traffic Core B

3
S1_05 2M Protection Trib

S1_04 Generic Trib 2

S1_03 2M Trib 2

S1_02 Generic Trib 1

S1_01 2M Trib 1

63 Port 2MBit/s Trib (protection)

19
Trib
Group
2

S1_03 2M Trib 2

1
2
3
1
1
2
3
Trib
Group
3
Trib
Group
4

S1_10 2M Trib 4

S3 12 Generic Trib 3 PSU/LTU

S3 11 2M LTU 3C

S3 10 2M LTU 3B

S3 09 2M LTU 3A

S3 08 Generic Trib 2 PSU/LTU

S3 07 2M LTU 2C

S3 06 2M LTU 2B

S3 05 2M LTU 2A

S3 04 Generic Trib 1 PSU/LTU

S3 03 2M LTU 1C

S3 02 2M LTU 1B

S3 01 2M LTU 1A

Unit

S3 21 Power & LCT LTU

S3 20 Power & LCT LTU

S3 19 Generic Trib 7 PSU/LTU

S3 18 Generic Trib 6 PSU/LTU

S1_14 Generic Trib 7


S1_15 Comms/Aux/Ancilliary

S3 17 Generic Trib 5 PSU/LTU

3
S1_13 Generic Trib 6

S3 16 Generic Trib 4 PSU/LTU

S3 15 2M LTU 4C

S3 14 2M LTU 4B

S3 13 2M LTU 4A

3
S1_12 Generic Trib 5

1
1
2
S1_11 Generic Trib 4

1
2
S1_09 Generic Trib 3

S1_08 2M Trib 3

[blank]

S1_07 Traffic Core A /CCU

S1_06 Traffic Core B

S1_05 2M Protection Trib

S1_04 Generic Trib 2

S1_02 Generic Trib 1

Trib
Group
1

S1_01 2M Trib 1

2Mb/s Trib Numbering (Balanced)

Line Termination Unit (2 Mbs Balance)


Connector(PIN)
Wire a (-) Wire b (+)
14
13
12
11
10
9
8
7
6
5
4
3
2
1
29
28
27
26
25
24
23
22
21
20
19
18
17
16
44
43
42
41
40
39
38
37
36
35
34
33
32
31
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a

20

Pair
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a

Layer

BLUE

ORANGE

GREEN

BROWN

Colour Code
Wire a (-)
Wire b (+)
WHITE
BLUE
WHITE
ORANGE
WHITE
GREEN
WHITE
BROWN
WHITE
GREY
RED
BLUE
RED
ORANGE
RED
GREEN
WHITE
BLUE
WHITE
ORANGE
WHITE
GREEN
WHITE
BROWN
WHITE
GREY
RED
BLUE
RED
ORANGE
RED
GREEN
WHITE
BLUE
WHITE
ORANGE
WHITE
GREEN
WHITE
BROWN
WHITE
GREY
RED
BLUE
RED
ORANGE
RED
GREEN
WHITE
BLUE
WHITE
ORANGE
WHITE
GREEN
WHITE
BROWN
WHITE
GREY
RED
BLUE
RED
ORANGE
RED
GREEN

21
Trib
Group
2

S3 16 Generic Trib 4 PSU/LTU

S3 15 2M LTU 4C

S3 14 2M LTU 4B

S3 13 2M LTU 4A

S3 12 Generic Trib 3 PSU/LTU

S3 11 2M LTU 3C

S3 10 2M LTU 3B

S3 09 2M LTU 3A

S3 08 Generic Trib 2 PSU/LTU

S3 07 2M LTU 2C

S3 06 2M LTU 2B

S3 05 2M LTU 2A

S3 04 Generic Trib 1 PSU/LTU

S3 03 2M LTU 1C

S3 02 2M LTU 1B

S3 01 2M LTU 1A

S1_15 Comms/Aux/Ancilliary
Unit

S3 21 Power & LCT LTU

S3 20 Power & LCT LTU

S3 19 Generic Trib 7 PSU/LTU

S3 18 Generic Trib 6 PSU/LTU

Trib
Group
4

S3 17 Generic Trib 5 PSU/LTU

S1_14 Generic Trib 7

S1_13 Generic Trib 6

S1_12 Generic Trib 5

S1_11 Generic Trib 4

Trib
Group
3

S1_10 2M Trib 4

S1_09 Generic Trib 3

S1_08 2M Trib 3

[blank]

S1_07 Traffic Core A /CCU

S1_06 Traffic Core B

S1_05 2M Protection Trib

S1_04 Generic Trib 2

Trib
Group
1

S1_03 2M Trib 2

S1_02 Generic Trib 1

S1_01 2M Trib 1

2Mb/s Trib Numbering (Unbalanced)

Line Termination Unit (Clock IN/OUT)

22

Line Termination Unit (Rack Alarm Unit)

-S
-S
-S
b
unused
Z a (B )
Z a (L E )

+S
+S
+S
a
el
unused
Z a (A )
G ND

OMS BW7R

SDH Rack Alarm Unit

Alarm from OMS 1200 to Rack Alarm Unit


D-Type 15 Pin (Female), OMS 1200

23

D-Type 9 Pin (Male), RLDU

Pin No

Signal Name

Pin No

Signal Name

1
4
5
8
9

GND
EL
A
+S
ZA(LE)

1
4
3
9
6

+ Vs Service Voltage
Rack Red LED
Rack Yellow LED
Mechanical GND
- Vs Service Voltage

Line Terminations Unit (Alarm PIN)


D-Type 9 Pin (Female), User Output (SK6)
Pin No
1
2
3
4
5
6
7
8
9

Signal Name
User Out
User Out
GND
User Out
User Out
User Out
User Out
User Out
User Out

3A
3B
1A
1B
4A
4B
2A
2B

D-Type 15 Pin (Female), OMS 1200


(User input SK7)

24

Pin No

Signal Name

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

No Connection
User input 1
User input 2
User input 3
User input 4
User input 5
User input 6
No Connection
GND
GND
GND
GND
GND
GND
No Connection

Power and LCT LTU

NEGATIVE
(Blue)
EARTH
POSITIVE
(Red)

LCT 'F' I/F


(RJ-45)

25

The power/LCT LTU provides connection to


the DC power supply via a single 3-pin-D
type connector.
An RJ45 port provides local access to the
equipment via a PC.
Two power/LCT LTU can be fitted in slots
3_20 and Slots 3_21 for protection of the
DC power supply.
Only the power/LCT LTU at slots 3_21
provides LCT access for the equipment.

Small Form-Factor Pluggable


SMA 1/4 EX
SFP

Copyright - refer to the Title Page


26

www.marconi.com

SFP Interfaces
SFPs, hot pluggable - convenient,
easy-fit, consumer-type, latching
module clips into on-card socket

Increased flexibility interfaces plug into sockets on Core cards, Quad flexible Tributary cards and Ethernet
Tributary cards
Rugged solution for simple and reliable installation
Reduced installation time
Standardisation on LC connectors
Increased flexibility, same SFPs used in other Marconi Next Generation products, OMS16-XX and PacketSpan reduced inventory cost
In-service upgrade without removing card in the appropriate core, simply plug in module
In-service upgrade STM-1 to STM-4 in SMA1/4UC and SMA1/4EX, STM-4 to STM-16 in SMA16UC and SMA16EX

27

SFP Interfaces

SFP Types applicable to each card


SFP Module Type
1.0/2.3COAX STM-1
STM-1 S1.1
STM-1 L1.1
STM-1 L1.2
STM-4 S/I4.1
STM-4 L4.1
STM-4 L4.2
STM-16 S-16.1
STM-16 L-16.1
STM-16L-16.2

28

SMA1/4UC/ SMA16UC/
EX Core
EX Core
Line I/F
Line I/F
X
X
X
X
X
X
X
X
X
X
X
X
X

Multi-rate
SDH
Tributary
X
X
X
X
X
X
X

SFP Interfaces

Code No

29

Designation

Description

SU 66AA

S1.1

STM-1 Optical Module (LC)

SU 66AB

L1.1

STM-1 Optical Module (LC)

SU 66AC

L1.2

STM-1 Optical Module (LC)

SU 67AA

S4.1

STM-4 Optical Module (LC)

SU 67AB

L4.1

STM-4 Optical Module (LC)

SU 67AC

L4.2

STM-4 Optical Module (LC)

SU 65AA

EL

STM-1 Electrical Module

Core Card B

Core Card A

Amber In Traffic

Amber In Traffic
Red - Micro/Comms Alarm
Red - Traffic failure

Red - Traffic failure

LW Amber Test LED


LW Test/Restart Button
LE Amber Test LED
LE Test/Restart Button

LW Amber Test LED


LW Test/Restart Button
LE Amber Test LED
LE Test/Restart Button

Amber - Comms in use


Amber - Processing
Amber - SMC Data Base Invalid
30

Potrebbero piacerti anche