HEAT LOAD FORM (computerized computation)

Prepared by

Name of Job

Space used for


Size

Kasai, Ian G.
S200

:
### 406.683

ITEM

11.42

4644.31415
SUN GAIN OR
Temp. diff.

AREA OR QUANTITY

55.9444

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.

Prop. No.

Approve

FACTOR

BTU/HOUR

WALLS
283.80060000
WALLS
WALLS
WALLS
ROOF-SUN
0
ROOF-SHADED
0

15.2

x
x
x
x
x
x

SQ. FT.

local time
Sun time

local time

Peak Load

sun time

Hours of Operation: 10 Hours

x
x
x
x
x

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.

Estimate for

x
x
x
x
x

0.7605

x
x
x
x
x
x

0.47

x
x
x
x
x

0.54
0.4
0.4

646.69
0.00
0.00
0.00

CONDITIONS

DB
F

WB
F

%RH
%

DP

Outdoor (OA)

97

81

51

76

135

Room (RM)

75

62.6

50

55

65

Difference

22

XXX

XXX

XXX

70

CFM/PERSON
CFM/SQ. FT

=
=

0.00

SOLAR & TRANS. GAIN - WALLS & ROOF


S

October 30, 2015

cu. ft.

SOLAR GAIN -LOSS


GLASS
GLASS
GLASS
GLASS
SKYLIGHT

Date

23.1

4281.70
0.00
0.00
0.00
0.00
0.00

GR/LB

OUTDOOR AIR
30
VENTI-LATION

PEOPLE x
SQ. FT. x

7.5

CFM VENTILATION =

225

TRANS. GAIN - EXCEPT WALLS & ROOF


ALL GLASS
PARTITION
PARTITION
FLOOR
INFILTRATION

94.6944
245.0506
156.1114

SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.

CFM

x
x
x
x
x

22
17
17

SWINGING
1124.97
REVOLVING DOORS
1666.34
OPEN DOORS
INFIL-TRATION
1061.56
EXHAUST FAN
0.00
CRACK
0.00

STORAGE

30
2480
448

220.5
3.41
3.41
x
0.85

25151.59

SUBTOTAL

0.00
25151.59

ROOM SENSIBLE HEAT

0.00
25151.59

SUPP
LY
DUCT
LEAK

+
%

CFM
OUTDOOR AIR

225

22

0.1

1.08

Gr/lb x
184.5

PEOPLE

LB-HR

Gr/lbs

DEHUM CFM

CFM

225

70

0.1)

75

25686.19
EFFECTIVE ROOM SENS. HEAT
1.08
x
22.041
ROOM SENSIBLE HEAT
1.08
x

1.08

Gr/lbs

ROOM SENSIBLE HEAT


x

0.00
5535.00 DEHUM CFM

50.51

50.51 F)

1079.058

CFMda
F(rm-outlet)

CFMsa

0.000

RESULTING ENT. & LVG CONDITIONS AT APPARATUS

SUBTOTAL

5535.00

ROOM LATENT HEAT


%

5535.00

0.1

0.68

x
EFFECTIVE ROOM LATENT HEAT
EFFECTIVE ROOM TOTAL HEAT

75

225
1079.06

0.00 LDB

OUTDOOR AIR

SELECTED ADP =

25686.19

0.00 EDB

SAFETY FACTOR
SUPPLY DUCT LEAKAGE

50.5

DEHUMIDIFIED AIR QUANTITY


(

0.00
0.00
0.001

EFFECTIVE ROOM SENS. HEAT


EFFECTIVE ROOM TOTAL HEAT
0.7954

0.00

APPLIANCES ETC.
ADDITIONAL HEAT GAINS
SQ. FT x

CFM

SUPPLY AIR QUANTITY

CFM

VAPOR TRANS

25686.19
32292.19

INDICATED ADP

SUPPLY CFM

STEAM

225

534.60

LATENT HEAT

30

0.00

EFFECTIVE ROOM SENSIBLE HEAT

INFILTRATION
PEOPLE

=
=

APPARATUS DEW POINT

E SENS.
HEAT
FACTOR
ESHF

TEMP RISE

OUTLET TEMP
DIFF

FAN
H.P.

6615.00
8456.80 ESHF
1298.53
0.00
0.00 ADP

SUBTOTAL

SAFETY FACTOR

SUPPL
Y DUCT
HEAT
GAIN

CFM/PERSON
CFM/DOOR
0
CFM/FEET

CFM OUTDOOR AIR THRU OPERATION =

PEOPLE
WATTS
WATTS

SQ. FT

CFM INFILTRATION =

INTERNAL HEAT
PEOPLE
POWER
LIGHTS
APPLIANCES ETC.
ADDITIONAL HEAT GAINS

51

0.1

97

CFM

75
= 79.5873354

FROM PSYCH. CHART:

79.5873354

50.51
= 53.4177335
52.3 F

66.9

1071.00
6606.00
32292.19

RC

GTH
12000

3.8952

TOTAL AREA

406.6825
3.8952

tons

OUTOOOR AIR HEAT


SQ. FT
SENSIB

LATENT
RETUR
N DUCT

225
225

CFMx
CFMx
+

RETUR
N DUCT

22
70

F
x (
Gr/lb x (
+

0.1 BF) x
0.1 BF) x
HP
PUM
P

1.08
0.68

4811.40
9639.00

SUBTOTAL

14450.40

LB

RC

104.41

N DUCT
HEAT
GAIN

+
%

N DUCT
LEAK
GAIN

+
%

HP
PUM
P

AN
D
PIP

GRAND TOTAL HEAT

0.00

46742.59

omputerized computation)

local time
sun time
Hours of Operation: 10 Hours
GR/LB
135
65
70

OUTDOOR AIR
225
0
225

0
0
0
0
0
CFM
APPARATUS DEW POINT
EFFECTIVE ROOM SENS. HEAT
EFFECTIVE ROOM TOTAL HEAT
0.7954
F
DEHUMIDIFIED AIR QUANTITY
22.041

CFMda
F(rm-outlet)

SUPPLY AIR QUANTITY

CFMsa

CFMda

RESULTING ENT. & LVG CONDITIONS AT APPARATUS


)
)
F

tons

sq. ft
ton