Sei sulla pagina 1di 119

Seminar on

Sustainable Future through


Timber Design
UITM, Dec. 16.12.2014

Design Timber Structures


using
Eurocode 5

Simon Aicher

Contents of lecture
Basics of permissible stress and

semi-probabilistic partial factor concept

Interrelationship of
- Eurocodes,
- harmonized (timber) product standards,
- classification standards, calculation standards and
- test test standards
Basics of Eurocode 5 structure and contents
Design example: straight glulam beam (EC 5 vs. permissible concept)
Design example: curved glulam beam (EC 5 vs. permissible concept)
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

100 years old


glulam beams,
train repair hall,
Bellinzona, Italy

Olympic Ice rink


Hammar, Norway,
1994
glulam truss beams,
span:97m

Manufacture of timber parasols for Expo 2000, Hannover

HESS Limitless Verbindung (22)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

HESS Limitless Verbindung (23)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

7-storey timber
building, Berlin, 2011

10-storey timber
building, Melbourne,
Australia 2013

Eurocodes and supporting product and test standards


Eurocodes regulate design of timber, steel, concrete structures
in conjunction with national application documents but give
no provisions on material properties
Harmonized product standards regulate material properties of
harmonized building products (e.g. not adhesives) such as
EN 14080 glulam
EN 14081-1 solid timber in conjunction with national grading rules
and classification standard EN 1912 and strength class standard
EN 338
EN 15497 finger jointed lumber
EN 16351 cross laminated timber
EN 14374 LVL
EN 13986 panel products in conjunction with product / production standards, e.g.
EN 300 for OSB
Test standards, e.g. EN 408, EN 789,..
Calculation standards, e.g. EN 14358 on characteristic values

Permissible stress concept


act = 95

acting loads, hence resulting section forces E and stresses


represent in general 95% quantiles of the distributions

Design verification
act permissible
where in case of structural timber (roughly)

permissible = f50 /3
f50
Aicher

mean value of strength

Eurocode 5 Timber Structures

UITM 2014, Malaysia

13

Semiprobabilistic design concept with partial factors

act = 95

as in permissible stress concept the loads / section forces/ stress


distributions represent 95% quantiles of the distributions

Design verification
d design stress

d fd

fd design strength

d = act L
L partial factor for load (1,5 for live load; 1,35 for perm. load)
f d = fk kmod / M
fk

characteristic strength property (5% quantile)

kmod modification factor (time, climate)


M partial factor for strength (material dependant; 1,1 to 1,3)
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

14

Semiprobabilistic vs. permissible stress design concept


f05 = f50 (1 - 1,64 COV)
assuming COV = 0,12
f05 = f50 (1 0,2) = f50 / 1,25
f05 kmod
M

L = 1,5 partial factor for load

f50 kmod
1,25 M

with M = 1,3 and kmod = 0,8


f05 kmod
M

f50 0,8
1,25 1,3

f50
2

f05 kmod
f50
=
d = act L = act 1,5 fd =
M
2
f50
act f50
2 1,5 = 3 = permissible
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

15

Graphical illustration of semiprobabilistic design concept


Probability
density

ms
fs

z = mz = kmod mR - ms
fz

ms 95
pf = 10 -6
Aicher

ms 95 s

kmod mR 05

kmod mR
fR

R, s

kmod mR 05 / R

Eurocode 5 Timber Structures

UITM 2014, Malaysia

16

Eurocode 5: Design of Timber Structures Part 1-1

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

17

Structural Eurocode Program comprises

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

18

Scope of EN 1995

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

19

Structure of Eurocode 5 ( = EN 1995)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

20

Subjects / Topics of EN 1995-1-1

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

21

Normative References

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

22

Normative References (continued)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

23

Normative References (continued)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

24

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

25

Section 2 of EC 5: Basis of design

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

26

Section 2.2 of EC 5: Principles of limit state design

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

27

2.2.2 Ultimate limit states

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

28

2.2.3 Serviceability limit states

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

29

2.2.3 Serviceability limit states

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

30

2.3 Basic variables

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

31

2.3.1.2 Load-duration classes

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

32

2.3.1.2 Load-duration classes

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

33

2.3.1.3 Service classes

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

34

2.3.2 Materials and product properties

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

35

2.3.2 Materials and product properties

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

36

2.4 Verification by the partial factor method

5%- quantile value (lognormal dist.)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

37

Recommended partial factors M for material properties


EC 5 Table 2.3

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

38

2.4.2 Design values of geometrical data

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

39

2.4.2 Design value of a resistance

Example: Rk = Xk relevant cross-sectional quantity

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

40

EC 5 Section 3 Materials properties

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

41

3.1.3/4 Strength and deformation modification factors

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

42

EC 5 Table 3.1 Strength modification values kmod

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

43

EC 5 Table 3.1 Strength modification values kmod


(continued)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

44

Strength modification values kmod = f( time; moisture)


short
1 min

Strength modification factor

1.2
kmod

10Jahre
years50 Jahre
10
1
1 week
Woche 66months
Monate 10
years

Madison-Kurve

Service class 11/2


and2
Nutzungsklasse

0.8

Service class 3

Nutzungsklasse 3

0.6

0.4

very
short

short
kurz

sehr kurz

medium
mittel

permanent
stndig

long
lang

0.2

0
0 .0

1
0
.
0

0 .1

10

10

0
10

0
1

0
00

0
10

0
00

Accumulated duration of load [hours]


Aicher

Eurocode 5 Timber Structures

0
10

0
00

UITM 2014, Malaysia

45

EC 5 Table 3.2 Deformation modification values kdef

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

46

EC 5 Table 3.2 Deformation modification values kdef


(continued)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

47

EC 5 3.2: Solid timber

EN 15497
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

48

EC 5 3.3: Glued laminated timber

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

49

EC 5 3.3: Glued laminated timber

Now large finger joints are directly regulated in the


harmonized product standard for glulam,

Aicher

Eurocode 5 Timber Structures

EN 14080

UITM 2014, Malaysia

50

Example of large finger joint (single joint line)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

51

Example of large finger joint (two joint lines)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

52

Example of large finger joint (two joint lines)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

53

EC 5 3.3: Glued laminated timber

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

54

EC 5 3.4: Laminated veneer lumber (LVL)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

55

EC 5 3.4: Laminated veneer lumber (LVL)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

56

EC 5 3.5: Wood-based panels

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

57

EC 5 3.6: Adhesives

Note: As permissible structural adhesive families and respective classifications have


been profoundly changed in conjunction with introduction of one-component
Polyurethane (1K-PU) and polymer isocyanate (EPI) adhesives according to EN 15425
and EN 16351 principle P (2) is no more throughout valid because of EPI definitions.

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

58

EC 5 3.7: Metal fasteners

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

59

EC 5 Section 4: Durability

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

60

EC 5 Section 4: Durability

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

61

EC 5 Section 4: Durability

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

62

EC 5 Table 4.1 Corrosion protection of fasteners

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

63

EC 5 - Section 5: Basis of structural analysis

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

64

5.2 Members

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

65

5.4 Assemblies

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

66

5.4 Assemblies

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

67

5.4.2 Frame structures

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

68

5.4.4 Plane frames and arches

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

69

Examples of assumed initial geometry deviations


geometry of
frames

initial geometry
deviation corresponding
to symmetrical load

initial geometry
deviation corresponding
to non-symmetrical load

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

70

EC 5 - Section 6: Ultimate limit states

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

71

Tension
6.1.2 Tension parallel to the grain

6.1.2 Tension perpendicular to the grain

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

72

Compression
6.1.4 Compression parallel to the grain

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

73

Compression

6.1.4 Compression perpendicular to the grain

where

c,90,d

is the design compressive stress in the effective contact area


perpendicular to the grain;

Fc,90,d

is the design compressive load perpendicular to the grain;

Aef

is the effective contact area in compression perpendicular to


the grain;

Fc,90,d

is the design compressive strength perpendicular to the


grain;

kc,90

is a factor taking into account the load configuration, the


possibility of splitting and the degree of compressive
deformation.

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

74

Compression

6.1.4 Compression perpendicular to the grain

The effective contact area perpendicular to the grain, Aef, should be determined taking into
account an effective contact length parallel to the grain, where the actual contact length, , at
each side is increased by 30 mm, but not more than a, or 1/2, see Figure 6.2.
2. The value of kc,90 should be taken as 1,0 unless the conditions in the following paragraphs
apply. In these cases the higher value of kc,90 specified may be taken, with a limiting value
of kc,90 = 1,75.
3. For members on continuous supports, provided that 1 2h, see Figure 6.2a, the value
of kc,90 should be taken as:
kc,90 = 1,25 for solid softwood timber
kc,90 = 1,5 for glued laminated softwood timber
where h is the depth of the member and is the contact length.

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

75

Compression

6.1.4 Compression perpendicular to the grain

4. For members on discrete supports, provided that 1 2h, see Figure 6.2b, the value of kc,90
should be taken as:
kc,90 = 1,5 for solid softwood timber
kc,90 = 1,75 for glued laminated softwood timber provided that I 400 mm
where h is the depth of the member and is the contact length.

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

76

6.1.6 Bending

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

77

6.1.6 Bending

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

78

6.1.7 Shear

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

79

6.1.7 Shear (crack factor issue)


2. For the verification of shear resistance of members in bending, the influence
of cracks should be taken into account using an effective width of the member
given as:
bef = kcr b
where b is the width of the relevant section of the member.
NOTE: The recommended value for kcr is given as
kcr = 0,67

for solid timber

kcr = 0,67

for glued laminated timber

kcr = 1,0

for other wood-based products in


accordance with EN 13986 and EN
14374.

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

80

6.1.7 Shear

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

81

6.1.8 Torsion

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

82

6.2.2 Compression stresses at an angle to grain

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

83

6.2.3 Combined bending and axial tension

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

84

6.2.3 Combined bending and axial compression

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

85

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

86

6.4 Members with varying cross-section or curved shape

Figure 6.8 Single tapered beam

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

87

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

88

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

89

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

90

6.4 Members with varying cross-section or curved shape

(a)

Note: In curved beams


the apex zone extends
over the curved parts
of the beam

Figure 6.9 Double tapered (a) and curved (b) beams with the fibre direction parallel
to the lower edge of the beam
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

91

6.4 Members with varying cross-section or curved shape


Note: In pitched cambered
beams the apex zone
extends over the curved
parts of the beam

Figure 6.9 Pitched cambered beam (c) beam with the fibre direction parallel
to the lower edge of the beam
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

92

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

93

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

94

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

95

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

96

6.4 Members with varying cross-section or curved shape

or
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

97

6.4 Members with varying cross-section or curved shape

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

98

Design examples

Design of straight glulam member


- comparison of
Eurocode 5 vs. DIN 1052

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

99

Straight beam design comparison EC 5 vs. perm. stress concept

16x80 cm

q = 9 kN/m, g = 6 kN/m

GL 24 / BS 11
10 m

Geometry:
l = 10 m
b = 160 mm
h = 800 mm
S = b h/6 = 17 10-6 mm
I = b h/12 = 6.8 10-9 mm4

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

100

Design comparison EC 5 vs. perm. stress concept


Property

permissible concept

semi-probabilistic concept

Bending strength

m,perm = 11 N/mm

fm,k = 24 N/mm

Shear strength

v,perm = 1.2 N/mm

fv,k = 3.5 N/mm

MOE

Em = 11000 N/mm

Em,mean = 11000 N/mm

crack factor

kcr = 0.67

modification factor for duration


of load and moisture content

kmod = 0.6 (Service Class I/II,


medium-term)

Partial factor for material


properties

M = 1.25

(glulam, EC 5)

Deformation factor

kdef = 0.8 (Service Class I)

Partial factor for permanent


actions

G = 1.35

Partial factor for variable


actions

G = 1.5

Factor for quasi-permanent


value of a variable action

2,1 = 0.3

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

101

Design comparison EC 5 vs. perm. stress concept

Result

permissible concept

semi-probabilistic concept

distributed load

F = g + q = 15 kN/m

Fd = G g + Q q = 21.6 kN/m

bending moment M

M = F l / 8 = 188 kNm

Md = Fd l / 8 = 270 kNm

bending stress

m = M/S = 11 N/mm

m = Md/S = 15.8 N/mm

utilization (bending)

11 / 11 = 1.00

fm,d = fm,k kmod /M = 15.4 N/mm


15.8 / fm,d = 1.03

shear force V

V = F l/2 = 75 kN

Vd = Fd l/2 = 108 kN

shear stress v

1.5 V / (b h) = 0.88 N/mm

1.5 Vd / (b h) = 1.89 N/mm

1.2 / 0.88 = 0.73

fv,d = fv,k kmod /M = 2.24 N/mm


1.89 / fv,d = 0.84

utilization (shear)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

102

Design comparison EC 5 vs. perm. stress concept

deflection

utilitization (deflection)

Aicher

5 4
=
= 26
384

= 0.78
/300

Eurocode 5 Timber Structures

= , + ,=
5 4
5 4
+
= 10.4 + 15.6
384 384
= 26
= , (1 + ) +
, (1 +2,1 )=
16.7 + 18.4 = 35.1mm

= 0.78
/300

= 0.53
/150

UITM 2014, Malaysia

103

Design examples

Design of curved glulam beam


- comparison of
Eurocode 5 vs. DIN 1052

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

104

HESS Limitless Verbindung (7)

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

106

Stress distributions in curved beams with const. moment

R1 < R2

R1 < R2
H/R2 = 0,09

= 0,09
RH/R
2 / H2 = 11
RH/R
=2,5
0,4
1 / H1 =

tension stresses
perpendicular to grain

,max
Aicher

H M
= 0,25
R W
Eurocode 5 Timber Structures

H/R1 = 0,4

bending stresses
parallel to grain
2

H
H M
II = 1+ 0,35 + 0,6
R
R W

UITM 2014, Malaysia

107

Stress t,90 of curved and tapered beams with line loads

stress perp.
to grain
h

stress perp.
to grain

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

108

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

109

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

110

Curved beam design comparison EC 5 vs. perm. stress concept

DIN 1052 BS 14: m,permissible = 14 N/mm2


EN 14080 GL 28: fm,k = 28 N/mm2
Geometry, dimensions and quality /strength class
of example beam
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

111

Curved beam design comparison EC 5 vs. perm. stress concept

EC5

F = 23,31 kN

Design for bending:

rin/t = 200,
kr = 0,96

hap / r = 0,118
k1 = 1; k2 = 0,35, k3 = 0,6
kl = 1,05
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

112

Curved beam design comparison EC 5 vs. perm. stress concept

F = 23,31 kN

EC5

Design for bending:

GL28:
fm,k = 28 N/mm2

load duration:
medium, kmod = 0,8

fm,d = fm,k kmod /m

kr = 0,96

fm,d =

glulam: m = 1,25

17,92 N/mm2

ratio = 0,38
kl = 1,05

Map,d = f Map

m,d = 6,85 N/mm2

combined loading: f = 1,4

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

113

curved beam design comparison EC 5 vs. perm. stress concept

EC5

Design for tension perp.:

glulam: V0 = 0,01 m3
kdis = 1,4

V = 0,691 m3

kVol = (V0/V)0,2 = 0,43

hap / r = 0,118
k5 = 0; k6 = 0,25, k7 = 0
kp = 0,0294
Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

114

Example: Curved Beam with pure moment loading


F = 23,31 kN

EC5

Design for tension perp.:

glulam:
ft,90,k = 0,5 N/mm2

kdis = 1,4 , kVol = 0,43,

load duration:
medium, kmod = 0,8

ft,90,d = ft,90,k kmod /m

glulam: m = 1,25

ft,90,d = 0,32 N/mm2

1,4 x 0,43 x 0,32 = 0,19 N/mm2


kp = 0,0294

Map,d = f Map

t,90,d = 0,19 N/mm2

ratio
= 1,0

combined loading: f = 1,4

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

115

Curved beam design comparison EC 5 vs. perm. stress concept

DIN
1052

F = 23,31 kN

Design for bending:


m m,permissible

m,permissible = 14 N/mm2

ratio = 0,33
m = kl 6 Map/b h2
hap / r = 0,118, kl = 1,05
Aicher

m = 4,66 N/mm2

Eurocode 5 Timber Structures

UITM 2014, Malaysia

116

curved beam design comparison EC 5 vs. perm. stress concept

DIN
1052

F = 23,31 kN

Design fr tension perp.:


t,90 t,90,permissible

t,90,permissible = 0,2 N/mm2

ratio = 0,69

t,90 = kp 6 Map/b h2
hap / r = 0,118, kp = 0,0294

Aicher

Eurocode 5 Timber Structures

t,90 = 0,14 N/mm2

UITM 2014, Malaysia

117

curved beam design comparison EC 5 vs. perm. stress concept

F = 23,31 kN

bending

tension perp.

EC5

0,40

1,00

DIN 1052

0,33

0,69

no pre-stress effect
Aicher

Eurocode 5 Timber Structures

no size effect
UITM 2014, Malaysia

118

Now ist time to finish!

Thank you very much for your patient listening!

Aicher

Eurocode 5 Timber Structures

UITM 2014, Malaysia

119

Potrebbero piacerti anche