LPG/C GAS SINCERITY

PANAMA

DEAD SHIP STARTING PROCEDURES

1. USE EMERGENCY AIR COMPRESSOR TO BUILD UP PRESSURE

2. ONCE EMERGENCY AIR PRESSURE TANK REACH 12 Kgf/cm2, PREPARE


TO START GENERATOR #1.

3. LINE UP FO SYSTEM, FW SYSTEM AND SW COOLING SYSTEM.

4. START GENERATOR #1 AND CLOSE THE AIR CIRCUIT BREAKER

5. START GENERATOR COOLING SW PUMP.

6. START MAIN AIR COMPRESSOR AND FILL UP THE MAIN RESERVOIR

7. START GENERATOR #2 AND SYNCHRONIZE WITH GENERATOR #1.

8. START AUX. BOILER AND COMMENCE HEATING WITH THE FUEL


TANKS.

9. START PURIFIER AND FILL UP THE FO SERVICE TANK.

10. LINE UP FO,LO,FW AND SW COOLING SYSTEM FOR MAIN ENGINE.

11. START MAIN LO PUMP AND JACK UP MAIN ENGINE FOR 30 MINS.

12. START MAIN ENGINE AND CHECK ALL PARAMETERS.

13. ONCE CONFIRM SMOOTH RUNNING, GRADUALLY INCREASE RPM


UNTIL NORMAL SPEED IS ATTAINED.

14. AGAIN, CHECK THE FOLLOWING:


 FO BOOSTER PUMP
 M/E COOLING FW PUMP
 BOILER CIRCULATING PUMP
 MAIN COOLING SW PUMP
 OTHER PARAMETERS

ACKNOWLEDGE BY:

2E MAPALAD, ROMMEL G. OLR JIMENEZ, DONALD R.

3E BIADOMA, RODRIGO C. OLR LAMPAYAN, EDUARDO A.

4E BURGA, ALLAN JASON L. OLR CABEL, ERNAND C.

PREPARED BY:

C/E FERNANDO A. HOMO


LPG/C GAS SINCERITY