0 valutazioniIl 0% ha trovato utile questo documento (0 voti)
57 visualizzazioni2 pagine
This document lists and provides details of various medical equipment used in a perinatology inventory. It includes 17 items such as infant warmers, incubators, suction devices, infusion pumps, oxygen saturation monitors, weighing scales, infant beds, and lamps. Specifications like models, serial numbers, voltages, frequencies, and powers are provided for each item.
This document lists and provides details of various medical equipment used in a perinatology inventory. It includes 17 items such as infant warmers, incubators, suction devices, infusion pumps, oxygen saturation monitors, weighing scales, infant beds, and lamps. Specifications like models, serial numbers, voltages, frequencies, and powers are provided for each item.
This document lists and provides details of various medical equipment used in a perinatology inventory. It includes 17 items such as infant warmers, incubators, suction devices, infusion pumps, oxygen saturation monitors, weighing scales, infant beds, and lamps. Specifications like models, serial numbers, voltages, frequencies, and powers are provided for each item.
Medel : BN -100 A Control Temp : 32 -38 Input Ratings : -220 V 50/60 Hz Rated power : 900 VA Product SN : 110301025 Infant warmer digital control ( meja resusitasi ) Poly 023 IW Input ratings : 220V AC/50 Hz Gea medical Baby incubator Model D 2006 Freq 50 Hz Volts 220-230 Power 300 VA SN 11010332 = 2011-01 GEA DY IA (suction ) Power aupply : AC 220 V 50 Hz : input : 30 VA
Max-vacuum : (18 1,5 ) Kpa ( 135 mmHg
11 mmHg )
- Flow pate : 6 L /min
- Fuse : RFI 5 x 20 /0,2 AL - No.13 YEl.110 manufacture date 2013.11 5. GEA dy IA ( suction ) - Power supply : AC 220 V 50 Hz : input :30 VA - Max vacuum : ( 18 1,5 ) kpa ( 135 mmHg 11 mmHg) - Flow rate : 6L / min - Fase : RFI 5x20 /0,2 AL - NO 12 yes 212 manufacture date 2012-7 6. Gea medical ( ligt trapy ) - Nenake Bilirubin photo therapy equipment - Model x Hz -90 - Freq 50 Hz - Volt 220-230 v - Power :150 VA - SN :42121006025 7. Terafusion infusion pump Te -112 ) ( insut pump ) - Medel : Te-112 - Serial no :12080000071 - Rated voltage : 100-240 VAc-50/60 Hz - Power Consuption :16 VA 8. Huntleigh ( saturasi O2 ) - Model No DSR - Serial no : 750 Bx 0100951-08 9. Infant-Non Autoclaveble ( ambubek ) - Pressure relif 40 cm H2O 10.Sella ( timbangan bayi ) - Capacity 20 kg grand 50 g bayi 10 kg 100 g bayi 20 kg 11.Gea medical ( BOX Bayi ) 5 buah
- Name infant bed
- Sn 72120801127 - Model YC,-B - 2012-08 12.Poly medical ( Box bayi ) 5 buah - Hospital eguipment - Poly 017 13.Poly medical ( box bayi ) 5 buah - Hospital equipment - Ply 018 14.Meja bayi ( poly medical ) 2 buah - Poly 026 15.Lampu penghangat bayi 1 buah - 227 1Ec 52 ( RVV) 300/300V - 3 x 0,75 mm3 gb 5023.5-1997 2003010105031535 16.Lampu penghangat bayi 2 buah - Montoya Quality cable H03 VV,F90 17.Gea medical ( tiang infuse ) 5 buah