Sei sulla pagina 1di 12

MICROPILE (TITAN 30/11) DESIGN FOR RUN-OFF BASIN 3

A) REQUIRED PILE CAPACITY:


Water Head, H = EL.12.96 - EL. 10.7

2.26 m

Thickness of Existing Slab, h

0.45 m
3.2 m

C/C Spacing of Piles, s


Unit Weight of Water, w

9.81 KN/m3

Unit Weight of Concrete, c

23.56 KN/m3

Area resisted by Single Pile, A = s2

10.24 m2

Applied Force per Single Pile due to Water, Fw = H x w x A

Resistance per Single Pile due to Weight of Existing Slab, W s = h x c x A

227.03 KN
108.56 KN

119 KN

Required Resitance by Single Pile, T = Fw - Ws

B) GEOTECHNICAL DESIGN OF PILE:


Drill bit diameter, d

90 mm

Grout Body Diameter, D = d + 50

140 mm

Factor of Safety, FOS


Grout to Ground Bond Strength,

150 KN/m2

Bonded Length, Lb
Geotechnical capacity of Pile, FG = x D x

6m

x Lb / FOS

132 KN

C) BEARING CAPACITY OF PILE:


Grout Capacity, (Ft)grout = x D x x Lplung / FOS

21.99 KN

Yeild Stress of Steel, Fy

625 N / mm2

Area of Steel, As

415 mm2

Capacity of Steel, (Ft)steel = 0.55 Fy . As

142.66 KN

Total Capacity of Pile, Ft = (Ft)grout + (Ft)steel

164.65 KN

Available FOS = ( Ws + Ft ) / Fw
Total Area of Basin, Abasin = 204 x 69.5

1.20
14178 m2

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

Nos. of Piles Required, N = Abasin / A


Total Pile Length, L = N x Lb

1323 Nos.
7938 m

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

> 119KN

OK

Lplung = 1.0m as per FWHA

> 119 KN
> 1.1

OK
OK

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

MICROPILE (TITAN 30/11) DESIGN FOR RUN-OFF BASIN 3


A) REQUIRED PILE CAPACITY:
1.81 m

Water Head, H = EL.12.96 - EL. 11.15


Thickness of Existing Slab, h

0.3 m

C/C Spacing of Piles, s

3.5 m

Unit Weight of Water, w

9.81 KN/m3

Unit Weight of Concrete, c

23.56 KN/m3

Area resisted by Single Pile, A = s2

12.25 m2

Applied Force per Single Pile due to Water, Fw = H x w x A

217.51 KN

Resistance per Single Pile due to Weight of Existing Slab, W s = h x c x A

86.58 KN

Required Resitance by Single Pile, T = Fw - Ws

131 KN

B) GEOTECHNICAL DESIGN OF PILE:


Drill bit diameter, d

90 mm

Grout Body Diameter, D = d + 50

140 mm

Factor of Safety, FOS


Grout to Ground Bond Strength,

150 KN/m2

Bonded Length, Lb
Geotechnical capacity of Pile, FG = x D x

6m

x Lb / FOS

132 KN

C) BEARING CAPACITY OF PILE:


Grout Capacity, (Ft)grout = x D x x Lplung / FOS

21.99 KN

Yeild Stress of Steel, Fy

625 N / mm2

Area of Steel, As

415 mm2

Capacity of Steel, (Ft)steel = 0.55 Fy . As

142.66 KN

Total Capacity of Pile, Ft = (Ft)grout + (Ft)steel

164.65 KN

Available FOS = ( Ws + Ft ) / Fw
Total Area of Basin, Abasin = 204 x 69.5

1.16
14178 m2

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

Nos. of Piles Required, N = Abasin / A


Total Pile Length, L = N x Lb

1158 Nos.
6948 m

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

> 131KN

OK

Lplung = 1.0m as per FWHA

> 131 KN
> 1.1

OK
OK

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

MICROPILE (TITAN 30/11) DESIGN FOR RUN-OFF BASIN 3


A) REQUIRED PILE CAPACITY:
Water Head, H = EL.12.96 - EL. 11.00

1.96 m

Thickness of Existing Slab, h

0.45 m
3.8 m

C/C Spacing of Piles, s


Unit Weight of Water, w

9.81 KN/m3

Unit Weight of Concrete, c

23.56 KN/m3

Area resisted by Single Pile, A = s2

14.44 m2

Applied Force per Single Pile due to Water, Fw = H x w x A

Resistance per Single Pile due to Weight of Existing Slab, W s = h x c x A

277.65 KN
153.09 KN

125 KN

Required Resitance by Single Pile, T = Fw - Ws

B) GEOTECHNICAL DESIGN OF PILE:


Drill bit diameter, d

90 mm

Grout Body Diameter, D = d + 50

140 mm

Factor of Safety, FOS


Grout to Ground Bond Strength,

150 KN/m2

Bonded Length, Lb
Geotechnical capacity of Pile, FG = x D x

6m

x Lb / FOS

132 KN

C) BEARING CAPACITY OF PILE:


Grout Capacity, (Ft)grout = x D x x Lplung / FOS

21.99 KN

Yeild Stress of Steel, Fy

625 N / mm2

Area of Steel, As

415 mm2

Capacity of Steel, (Ft)steel = 0.55 Fy . As

142.66 KN

Total Capacity of Pile, Ft = (Ft)grout + (Ft)steel

164.65 KN

Available FOS = ( Ws + Ft ) / Fw
Total Area of Basin, Abasin = 204 x 69.5

1.14
14178 m2

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

Nos. of Piles Required, N = Abasin / A


Total Pile Length, L = N x Lb

982 Nos.
5892 m

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

10

> 125KN

OK

Lplung = 1.0m as per FWHA

> 125 KN
> 1.1

OK
OK

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

11

RAS TANURA INTEGRATED PROJECT: MODIFICATIONS TO EXISTING SURFACE WATER RUN-OFF BASIN 3
DESIGN OF MICROPILE (TITAN 30/11) FOR TENSION

12

Potrebbero piacerti anche