Sei sulla pagina 1di 7

Searching for disks...

done
c0t60080E50002FD9F400000B3A54F0A1F4d0: configured with capacity of 66.00GB
c0t60080E50002FEEE600000D6654F0A1FCd0: configured with capacity of 66.00GB
c0t60080E50002FEEE600000D6854F0A297d0: configured with capacity of 66.00GB
c3t203200A098622FD7d7: configured with capacity of 16.00MB
c4t203300A098622FD7d0: configured with capacity of 449.98GB
c4t203300A098622FD7d1: configured with capacity of 500.98GB
c4t203300A098622FD7d2: configured with capacity of 500.98GB
c4t203300A098622FD7d3: configured with capacity of 709.97GB
c4t203300A098622FD7d4: configured with capacity of 704.97GB
c4t203300A098622FD7d5: configured with capacity of 374.98GB
c4t203300A098622FD7d6: configured with capacity of 374.98GB
c4t203300A098622FD7d7: configured with capacity of 16.00MB
c4t203300A098622FD7d8: configured with capacity of 400.98GB
c4t203300A098622FD7d9: configured with capacity of 400.98GB
c4t203300A098622FD7d10: configured with capacity of 400.98GB
c4t203300A098622FD7d11: configured with capacity of 400.98GB
c4t203300A098622FD7d12: configured with capacity of 329.98GB
c4t203300A098622FD7d13: configured with capacity of 329.98GB
c4t203300A098622FD7d14: configured with capacity of 350.98GB
c4t203300A098622FD7d15: configured with capacity of 91.00GB
AVAILABLE DISK SELECTIONS:
0. c0t60080E50002FD9F400000A83531A97ABd0 <SUN-LCSM100_F-0784
t 2 hd 128 sec 139> jup02
/scsi_vhci/ssd@g60080e50002fd9f400000a83531a97ab
1. c0t60080E50002FD9F400000AD2534BF113d0 <SUN-LCSM100_F-0784
t 2 hd 128 sec 64> Recau_02
/scsi_vhci/ssd@g60080e50002fd9f400000ad2534bf113
2. c0t60080E50002FD9F400000AD853515282d0 <SUN-LCSM100_F-0784
t 2 hd 256 sec 64> alma-01
/scsi_vhci/ssd@g60080e50002fd9f400000ad853515282
3. c0t60080E50002FD9F400000ADB5351536Dd0 <SUN-LCSM100_F-0784
t 2 hd 256 sec 64> alma-03
/scsi_vhci/ssd@g60080e50002fd9f400000adb5351536d
4. c0t60080E50002FD9F400000ADE5354F41Ed0 <SUN-LCSM100_F-0784
t 2 hd 64 sec 64> rsn_02
/scsi_vhci/ssd@g60080e50002fd9f400000ade5354f41e
5. c0t60080E50002FD9F400000AE2535F6B6Ad0 <SUN-LCSM100_F-0784
t 2 hd 128 sec 64> gen_02
/scsi_vhci/ssd@g60080e50002fd9f400000ae2535f6b6a
6. c0t60080E50002FD9F400000AE05354F798d0 <SUN-LCSM100_F-0784
t 2 hd 512 sec 64> gen_v8
/scsi_vhci/ssd@g60080e50002fd9f400000ae05354f798
7. c0t60080E50002FD9F400000AEC535F8C91d0 <SUN-LCSM100_F-0784
t 2 hd 128 sec 64> gen_01
/scsi_vhci/ssd@g60080e50002fd9f400000aec535f8c91
8. c0t60080E50002FD9F400000AF25360A6FAd0 <SUN-LCSM100_F-0784
t 2 hd 256 sec 64> reca_mrr
/scsi_vhci/ssd@g60080e50002fd9f400000af25360a6fa
9. c0t60080E50002FD9F400000B1A53985783d0 <SUN-LCSM100_F-0784
t 2 hd 128 sec 64> apolo_1
/scsi_vhci/ssd@g60080e50002fd9f400000b1a53985783
10. c0t60080E50002FD9F400000B1C53985820d0 <SUN-LCSM100_F-0784
t 2 hd 128 sec 64> apolo_3
/scsi_vhci/ssd@g60080e50002fd9f400000b1c53985820
11. c0t60080E50002FD9F400000B3A54F0A1F4d0 <SUN-LCSM100_F-0784
t 2 hd 64 sec 64>

cyl 65533 al
cyl 38654 al
cyl 36350 al
cyl 36350 al
cyl 59902 al
cyl 63998 al
cyl 47998 al
cyl 63998 al
cyl 57598 al
cyl 60158 al
cyl 60158 al
cyl 33790 al

/scsi_vhci/ssd@g60080e50002fd9f400000b3a54f0a1f4
12. c0t60080E50002FD9F400000B3153BC1B2Cd0 <SUN-LCSM100_F-0784 cyl
t 2 hd 64 sec 64> alma-04
/scsi_vhci/ssd@g60080e50002fd9f400000b3153bc1b2c
13. c0t60080E50002FD9F400000B3353BC1BA5d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 64 sec 64> alma-06
/scsi_vhci/ssd@g60080e50002fd9f400000b3353bc1ba5
14. c0t60080E50002FD9F400000B3553BC2341d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 64 sec 64> Recau_05
/scsi_vhci/ssd@g60080e50002fd9f400000b3553bc2341
15. c0t60080E50002FD9F400000B3753BC26E2d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 256 sec 64> beta1t4
/scsi_vhci/ssd@g60080e50002fd9f400000b3753bc26e2
16. c0t60080E50002FD9F4000008BA516D5838d0 <drive not available>
/scsi_vhci/ssd@g60080e50002fd9f4000008ba516d5838
17. c0t60080E50002FD9F4000008BE519F6380d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 255 sec 189> isisbck
/scsi_vhci/ssd@g60080e50002fd9f4000008be519f6380
18. c0t60080E50002FD9F4000008F852440590d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 255 sec 189> isis_fs
/scsi_vhci/ssd@g60080e50002fd9f4000008f852440590
19. c0t60080E50002FD9F4000009DD52EA7203d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 64> pxs_01
/scsi_vhci/ssd@g60080e50002fd9f4000009dd52ea7203
20. c0t60080E50002FD9F4000009E052EA727Fd0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 64> psx_03
/scsi_vhci/ssd@g60080e50002fd9f4000009e052ea727f
21. c0t60080E50002FD9F40000087F5141C6C3d0 <drive not available>
/scsi_vhci/ssd@g60080e50002fd9f40000087f5141c6c3
22. c0t60080E50002FEEE600000A9E52556E09d0 <SUN-LCSM100_F-0784 cyl
2 hd 64 sec 64> mddbt4_2
/scsi_vhci/ssd@g60080e50002feee600000a9e52556e09
23. c0t60080E50002FEEE600000A93524A784Ad0 <SUN-LCSM100_F-0784 cyl
2 hd 64 sec 64> mddbt4
/scsi_vhci/ssd@g60080e50002feee600000a93524a784a
24. c0t60080E50002FEEE600000A4151658DA9d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 255 sec 189> jupbck1
/scsi_vhci/ssd@g60080e50002feee600000a4151658da9
25. c0t60080E50002FEEE600000B7A52EA727Ad0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 64> pxs_02
/scsi_vhci/ssd@g60080e50002feee600000b7a52ea727a
26. c0t60080E50002FEEE600000C7C534BF18Ed0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 64> Recau_03
/scsi_vhci/ssd@g60080e50002feee600000c7c534bf18e
27. c0t60080E50002FEEE600000C8F535F74EAd0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 64> gen_03
/scsi_vhci/ssd@g60080e50002feee600000c8f535f74ea
28. c0t60080E50002FEEE600000C33531A97B3d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 139> jup01
/scsi_vhci/ssd@g60080e50002feee600000c33531a97b3
29. c0t60080E50002FEEE600000C36531A9822d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 139> jup03
/scsi_vhci/ssd@g60080e50002feee600000c36531a9822
30. c0t60080E50002FEEE600000C79534BF11Fd0 <SUN-LCSM100_F-0784 cyl
t 2 hd 128 sec 64> Recau_01
/scsi_vhci/ssd@g60080e50002feee600000c79534bf11f
31. c0t60080E50002FEEE600000C835354F423d0 <SUN-LCSM100_F-0784 cyl
t 2 hd 64 sec 64> rsn_01
/scsi_vhci/ssd@g60080e50002feee600000c835354f423
32. c0t60080E50002FEEE600000C855354F4AFd0 <SUN-LCSM100_F-0784 cyl

34148 al
34148 al
34148 al
63998 al

44556 al
44556 al
38654 al
38654 al

1022 alt
1022 alt
52214 al
38654 al
38654 al
63998 al
65533 al
65533 al
38654 al
59902 al
59902 al

t 2 hd 64 sec 64> rsn_03


/scsi_vhci/ssd@g60080e50002feee600000c855354f4af
33. c0t60080E50002FEEE600000C875354FA37d0 <SUN-LCSM100_F-0784 cyl 46078 al
t 2 hd 64 sec 64> vari_v7
/scsi_vhci/ssd@g60080e50002feee600000c875354fa37
34. c0t60080E50002FEEE600000C595323207Cd0 <SUN-LCSM100_F-0784 cyl 51198 al
t 2 hd 128 sec 64> betat4
/scsi_vhci/ssd@g60080e50002feee600000c595323207c
35. c0t60080E50002FEEE600000C8053515341d0 <SUN-LCSM100_F-0784 cyl 36350 al
t 2 hd 256 sec 64> alma-02
/scsi_vhci/ssd@g60080e50002feee600000c8053515341
36. c0t60080E50002FEEE600000CC753985822d0 <SUN-LCSM100_F-0784 cyl 60158 al
t 2 hd 128 sec 64> apolo_2
/scsi_vhci/ssd@g60080e50002feee600000cc753985822
37. c0t60080E50002FEEE600000CEE53BC1BBDd0 <SUN-LCSM100_F-0784 cyl 34148 al
t 2 hd 64 sec 64> alma-05
/scsi_vhci/ssd@g60080e50002feee600000cee53bc1bbd
38. c0t60080E50002FEEE600000CF053BC2330d0 <SUN-LCSM100_F-0784 cyl 34148 al
t 2 hd 64 sec 64> Recau_04
/scsi_vhci/ssd@g60080e50002feee600000cf053bc2330
39. c0t60080E50002FEEE600000CF253BC23C9d0 <SUN-LCSM100_F-0784 cyl 34148 al
t 2 hd 64 sec 64> Recau_06
/scsi_vhci/ssd@g60080e50002feee600000cf253bc23c9
40. c0t60080E50002FEEE600000D6654F0A1FCd0 <SUN-LCSM100_F-0784 cyl 33790 al
t 2 hd 64 sec 64>
/scsi_vhci/ssd@g60080e50002feee600000d6654f0a1fc
41. c0t60080E50002FEEE600000D6854F0A297d0 <SUN-LCSM100_F-0784 cyl 33790 al
t 2 hd 64 sec 64>
/scsi_vhci/ssd@g60080e50002feee600000d6854f0a297
42. c3t203200A098622FD7d0 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,0
43. c3t203200A098622FD7d1 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,1
44. c3t203200A098622FD7d2 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,2
45. c3t203200A098622FD7d3 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,3
46. c3t203200A098622FD7d4 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,4
47. c3t203200A098622FD7d5 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,5
48. c3t203200A098622FD7d6 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,6
49. c3t203200A098622FD7d7 <NETAPP-UniversalXport-0820 cyl 8 alt 2 hd 64 se
c 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,7
50. c3t203200A098622FD7d8 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,8
51. c3t203200A098622FD7d9 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,9
52. c3t203200A098622FD7d10 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,a
53. c3t203200A098622FD7d11 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,b
54. c3t203200A098622FD7d12 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,c
55. c3t203200A098622FD7d13 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,d
56. c3t203200A098622FD7d14 <drive type unknown>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,e

57. c3t203200A098622FD7d15 <drive type unknown>


/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0/fp@0,0/ssd@w203200a098622fd7,f

61. c4t203300A098622FD7d3 <NETAPP-INF-01-00-0820 cyl 45438 alt 2 hd 512 se


c 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,3
62. c4t203300A098622FD7d4 <NETAPP-INF-01-00-0820 cyl 45118 alt 2 hd 512 se
c 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,4
65. c4t203300A098622FD7d7 <NETAPP-UniversalXport-0820 cyl 8 alt 2 hd 64 se
c 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,7
66. c4t203300A098622FD7d8 <NETAPP-INF-01-00-0820 cyl 51326 alt 2 hd 256 se
c 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,8
67. c4t203300A098622FD7d9 <NETAPP-INF-01-00-0820 cyl 51326 alt 2 hd 256 se
c 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,9
68. c4t203300A098622FD7d10 <NETAPP-INF-01-00-0820 cyl 51326 alt 2 hd 256 s
ec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,a
69. c4t203300A098622FD7d11 <NETAPP-INF-01-00-0820 cyl 51326 alt 2 hd 256 s
ec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,b

74. c5t5000CCA03C4738BDd0 <HITACHI-H106060SDSUN600G-A3D0-558.91GB> zonas


/pci@400/pci@2/pci@0/pci@e/scsi@0/iport@1/disk@w5000cca03c4738bd,0
75. c6t5000CCA03C22D891d0 <HITACHI-H106060SDSUN600G-A2B0 cyl 64986 alt 2 h
d 27 sec 668> solaris
/pci@400/pci@2/pci@0/pci@e/scsi@0/iport@2/disk@w5000cca03c22d891,0
76. c7t5000CCA03C484D9Dd0 <HITACHI-H106060SDSUN600G-A3D0-558.91GB> zonas
/pci@400/pci@2/pci@0/pci@e/scsi@0/iport@4/disk@w5000cca03c484d9d,0
77. c8t5000CCA03C4F4D7Dd0 <SUN600G cyl 64986 alt 2 hd 27 sec 668> solaris
/pci@400/pci@2/pci@0/pci@e/scsi@0/iport@8/disk@w5000cca03c4f4d7d,0

Volumenes Almacenes
59. c4t203300A098622FD7d1 <NETAPP-INF-01-00-0820 cyl 64126 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,1
60. c4t203300A098622FD7d2 <NETAPP-INF-01-00-0820 cyl 64126 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,2

================================================================================
========================================================

Volumenes Recaudos
70. c4t203300A098622FD7d12 <NETAPP-INF-01-00-0820 cyl 42238 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,c
71. c4t203300A098622FD7d13 <NETAPP-INF-01-00-0820 cyl 42238 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,d
Mediante el uso de Format podemos identificar los discos que tenemos a disposicin
en nuestro servidor. Un ejemplo es este fragmento de salida del comando format..
.
70. c4t203300A098622FD7d12 <NETAPP-INF-01-00-0820 cyl 42238 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,c
71. c4t203300A098622FD7d13 <NETAPP-INF-01-00-0820 cyl 42238 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,d
Si deseamos crear un diskset con estos dos discos o LUNs, debemos ejecutar el co
mando metaset de la siguiente manera
1) Creamos el Disk Set
metaset -s recnetapp_md -a -h solaris-t4
-s es el nombre que vamos a darle
-a agrega el nombre del host al set
-h el nombre del host
Si todo va bien, no se nos presentar ningn mensaje de error. Luego de ello verificam
os que se haya creado el DiskSet
[solaris-t4: / 12:45:11]# metaset -s recnetapp_md
Set name = recnetapp_md, Set number = 14
Host
solaris-t4

Owner

Ahora, lo siguiente es agregar los discos al Set que hemos creado previamente. L
o que hacemos con el siguiente comando...
[solaris-t4: / 12:45:38]# metaset -s recnetapp_md -a c4t203300A098622FD7d12 c4t2
03300A098622FD7d13
metaset: solaris-t4: /dev/rdsk/c4t203300A098622FD7d12: Invalid argument
Como pueden ver, se muestra un mensaje de error. En mi caso lo pude resolver eje
cutanto el comando format en el sistema, luego escogiendo el LUN o disco que qui
ero mirar.

[solaris-t4: / 12:49:42]# format


Searching for disks...done
...
...
...
Specify disk (enter its number)[70]: 71
selecting c4t203300A098622FD7d13
[disk formatted]
Disk not labeled. Label it now? y
format> quit
YA con esto, no se generar el error anterior. Ejecutamos nuevamente el comando met
aset....
[solaris-t4: / 12:52:33]# metaset -s recnetapp_md -a c4t203300A098622FD7d12 c4t2
03300A098622FD7d13
No nos muestra errores... y volvemos a verificar el DiskSet
[solaris-t4: / 12:52:47]# metaset -s recnetapp_md
Set name = recnetapp_md, Set number = 14
Host
solaris-t4

Owner
Yes

Drive

Dbase

/dev/dsk/c4t203300A098622FD7d12

Yes

/dev/dsk/c4t203300A098622FD7d13

Yes

Y as es como hemos creado nuestro primer metaset.


metainit -s recnetapp_md d7000 1 2 c4t203300A098622FD7d12s0 c4t203300A098622FD7d
13s0

metaset -s recnetapp_md -a c4t203300A098622FD7d12 c4t203300A098622FD7d13

metainit d50 2 1 c4t203300A098622FD7d12 1 c4t203300A098622FD7d13

================================================================================
=========================================
Volumen PXS
58. c4t203300A098622FD7d0 <NETAPP-INF-01-00-0820 cyl 57598 alt 2 hd 256 sec 64>

/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,0

================================================================================
=================================
Volumenes Genesix
63. c4t203300A098622FD7d5 <NETAPP-INF-01-00-0820 cyl 47998 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,5
64. c4t203300A098622FD7d6 <NETAPP-INF-01-00-0820 cyl 47998 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,6
gen_netapp_md
metaset -s gen_netapp_md -a -h solaris-t4
metaset -s gen_netapp_md
metaset -s gen_netapp_md -a c4t203300A098622FD7d5 c4t203300A098622FD7d6
metainit -s gen_netapp_md d3000 1 2 c4t203300A098622FD7d5s0 c4t203300A098622FD7d
6s0

Volumen RSN
72. c4t203300A098622FD7d14 <NETAPP-INF-01-00-0820 cyl 44926 alt 2 hd 256 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,e
Volumen Varios
73. c4t203300A098622FD7d15 <NETAPP-INF-01-00-0820 cyl 46590 alt 2 hd 64 sec 64>
/pci@400/pci@2/pci@0/pci@8/SUNW,qlc@0,1/fp@0,0/ssd@w203300a098622fd7,f
rsn_netapp_md