Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
CERTIFICATE
This is to certify that the report submitted on the topic CFD ANALYSIS OF HEAT
TRANSFER IN DOUBLE PIPE HEAT EXCHANGER by AAYUSH PATHAK , HAPPY
SONKHLA , MANISH SHARMA in partial fulfillment for the award of degree of Bachelor of
Technology of Jaypee University of Engineering & Technology, Guna has been carried out under my
supervision at JUET Guna campus during session 2014 to 2015. This work has not been submitted
partially or wholly to any other University or Institute for the award of this or any other degree or
diploma.
Signature of Supervisor :
Name of Supervisor
Designation
Date
2 | Page
ACKNOWLEDGEMENT
The completion of this project report has been made possible by the significant contributions of
many people.
I would like to thank Mr. SUBAS CHANDRA DASS (Lecturer) my guide in JAYPEE
UNIVERSITY OF ENGINEERING AND TECHNOLOGY giving me the support and encouragement
that I needed, and providing many valuable suggestions and insights for my work. I would also like to
thank,D Prof. N.N. DUTTA, Dr. Santosh bobdde, Mr.ATUL BHTTAD, and also my seniors Mr.ANKIT
SHUKLA , Mr. ABHISHEK RAJ who guided me throughout the project .He was always there to give
me valuable suggestions .
Id also like to express my gratitude towards the entire staff at the Mechanical Department of
J.U.E.T. for extending their support and assistance as and when I required it.
AAYUSH PATHAK (111602)
HAPPY SONKHLA (111636)
MANISH SHARMA (111646)
4th year Mechanical Engineering
J.U.E.T , GUNA
3 | Page
EXECUTIVE SUMMARY
Numerical analysis of 3-d incompressible flow is done for concentric tubular heat exchanger
type of domain ,this is basically water to water heat exchanger. Analysis is done for both parallel flow
and counter flow with different mass flow rate and when we compare the efficiency ,efficiency is higher
for counter flow and less for the parallel flow because in counter flow we have highest heat transfer area
than in parallel flow. Calculation are done for the cross cheq. Ansys Fluent is used for the analysis of
double pipe heat exchanger or analysis software.
Ansys design modler is used as input CAD package to the FLUENT. Pressure correction
technique is used for solving governing equation. Flow is basically simulated at higher Reynolds
no.,because when we increases the turbulence, efficiency of heat exchanger is also increases .analysis is
done in ansys workbench 12.1 and various contour plots and vector plots are presented .
4 | Page
CONTENT
CHAPTER NO. 1
PAGE No.
08
1.1 )Introduction
09
11
11
12
12
13
14
14
CHAPTER NO. 2
15
16
18
20
21
23
CHAPTER NO. 3
25
3.1) Geometry
26
3.2) Mesh
27
3.3) Solution
30
CHAPTER NO. 4
33
4.1) Contous
34
38
CHAPTER NO. 5
44
5.1) Conclusion
45
REFERENCES
46
5 | Page
LIST OF FIGURE
Page No.
12
13
28
29
30
35
36
37
37
Fig 10: Plot Of Surface Nusselt No. For Parallel Flow HEX
38
Fig 11: Plot Of Surface Nusselt No. For Counter Flow HEX
39
39
40
40
41
41
42
43
6 | Page
LIST OF TABLE
Table 1: Naming Of Various Parts Of BodyWith State Type
Page No.
27
29
31
Table 4: Residuals
33
35
36
36
38
41
42
7 | Page
CHAPTER 1
INTRODUCTION ABOUT PROJECT
1.1 INTRODUCTION
8 | Page
Heat exchange between flowing fluids is one of the most important physical process of concern,
and a variety of heat exchangers are used in different type of installations, as in process industries,
power plants, food processing, refrigeration, etc. The purpose of constructing a heat exchanger is to get
an efficient method of heat transfer from one fluid to another, by direct contact or by indirect contact.
The heat transfer occurs by three principles: conduction, convection and radiation. In a heat exchanger
the heat transfer through radiation is not taken into account as it is negligible in comparison to
conduction and convection. Conduction takes place when the heat from the high temperature fluid flows
through the surrounding solid wall. The conductive heat transfer can be maximised by selecting a
minimum thickness of wall of a highly conductive material. But convection is plays the major role in the
performance of a heat exchanger.
Forced convection in a heat exchanger transfers the heat from one moving stream to another
stream through the wall of the pipe. The cooler fluid removes heat from the hotter fluid as it flows along
or across it. Different co relation are used for the calculation of nusselt no. and heat transfer coefficient.
HEAT EXCHANGER
Recuperators
Regenerator
Fixed matrix
rotary
Tubular
Plate
Extended surface
Double tube
Gasketed plate
Plate fin
Spiral tube
Spiral plate
Tube fin
Lamela (Ramen)
A typical Double pipe heat exchanger consists of one pipe placed concentrically inside another
larger diameter with appropriate fittings to direct the flow from one section to next. As shown in fig.1
double pipe heat exchanger can be arranged into various series and parallel arrangements to meet
pressure drop and mean temperature difference requirements. The major use of double pipe heat
exchanger is for sensible heating and cooling of process fluid where small heat transfer areas is required
(upto 50 m2 ) . this configuration is also very suitable when one or both fluid are at higher pressure. The
major disadvantage is that double pipe heat exchanger are bulky and expensive per unit transfer surface
inner tube may be single tube or multi tube. If the heat transfer coefficient is poor for annulus, axially
finned inner tubes can be used. Generally double pipe heat exchanger are built in modular concept, i.e.
in the form of hairpins. Study has been done on the types of flows in the circular straight pipes, and the
effect of Prandtl and Reynolds number on the flow patterns and on Nusselt numbers. The two basic
boundary conditions that are faced in the applications are constant temperature and the constant heat
flux of the wall.
Convective heat transfer is the transfer of heat from one place to another by the movement of
fluids due to the difference in density across a film of the surrounding fluid over the hot surface.
Through this film heat transfer takes place by thermal conduction and as thermal conductivity of most
fluids is low, the main resistance lies there. Heat transfer through the film can be enhanced by increasing
the velocity of the fluid flowing over the surface which results in reduction in thickness of film. The
equation for rate of heat transfer by convection under steady state is given by,
Q = h A (Tw - Tatm)
Where,
h-is the film coefficient or surface coefficient (W/m2.K).
A is the area of the wall,
Tw is the wall temperature,
Tatm is surrounding temperature.
The value of h depends upon the properties of fluid within the film region; hence it is called
Heat Transfer Coefficient. It depends on various properties of fluid, linear dimensions of surface and
fluid velocity (i.e. nature of flow).
The overall heat transfer coefficient is the overall transfer rate of a series or parallel combination
of convective and conductive walls. The overall Heat Transfer Coefficient is expressed in terms of
thermal resistances of each fluid stream. The summation of individual resistances is the total thermal
resistance and its inverse is the overall heat transfer coefficient, U.
Figure2 : wallconvection
1
1 Ao 1
Ao
Rfo
Rfi Rw
U ho Ai hi
Ai
12 | P a g e
Where,
U = overall heat transfer coefficient based on outside area of tube all
A = area of tube wall
h = convective heat transfer coefficient
Rf = thermal resistance due to fouling
Rw= thermal resistance due to wall conduction
and suffixes O and I refer to the outer and inner tubes, respectively.
It is extremely easy to build and easy of operation. Its handle differential thermal expansions by
the constructions of hairpin type components.
The make use of of longitudinal finned tubes, will having a low heat transfer coefficient.
Shortened delivery times can result from the use of stock components that can be assembled into
standard sections.
Modular design allows for the addition of sections at a later time or the rearrangement of sections
for new services.
Simple construction leads to ease of cleaning inspection and tube element replacement.
Hairpin sections are specifically intended units which are generally not built to any
manufacturing industry standard other than ASME Code. However, TEMA tolerances are normally
incorporated wherever applicable.
Various hairpin sections are not at all times cost-effectively competitive with a distinct shell and
tube heat exchanger.
13 | P a g e
14 | P a g e
CHAPTER 2
LITERATURE REVIEW
AND
INTRODUCTION ABOUT CFD
15 | P a g e
Heat transfer enhancement in a heat exchanger is getting industrial importance because it gives
the opportunity to reduce the heat transfer area for the heat exchanger. Increase in the heat exchanger
performance can help to make energy, material and cost saving related to a heat exchange process.
Double pipe heat exchangers are the simplest devices in which heat is transferred from the hot fluid to
the cold fluid through a separating cylindrical wall. They are primarily adapted to high temperature and
high pressure applications due to their small diameters. They are fairly cheap, but the amount of space
they occupy is relatively high compared to the other types. Hence for the given design and length of the
heat exchanger heat transfer enhancement in a double pipe heat exchanger is possibly achieved by
several methods. Chen et al used dimples as the heat transfer modification on the inner tube. Bhuiya et
al., Eiamsan et al. and Liao et al. used circular tube equipped with perforated twisted tape inserts with
different configurations to enhance the heat transfer through the tube. In order to intensify the heat
transfer from the heat exchanger surface to fluid, it is possible to increase convection coefficient (by
growing the fluid velocity), widen temperature difference between surface and fluid or increase the
surface area across which convection occurs. Extended surfaces, in the form of longitudinal or radial
fins are common applications where the need to enhance the heat transfer between a surface and an
adjacent fluid exists.Several researchers used extended surfaces for the enhancement in the heat transfer
Masliyah et al. studied heat transfer characteristics for a laminar forced convection fully
developed flow in an internally triangular finned circular tube with axially uniform heat flux using a
finite element method. For a given fin geometry, the Nusselt number based on inside tube diameter was
higher than that for a smooth tube. Also, it was found that for maximum heat transfer there exists an
optimum fin number for a given fin configuration. Agarwal et al. studied Laminar flow and heat transfer
magnitudes in a finned tube annulus. Pressure drop and heat transfer characteristics of the fins are
obtained in the periodically fully developed region by varying geometric and flow parameters.
Geometric parameters are annulus radius ratio (0.3 to 0.5), fin height/annular gap (0.33 to 0.67) and fin
spacing/annular gap (2 to 5). Flow parameters are Reynolds number (100 to 1000) and Prandtl number
(1 to 5). Comparisons are made with a plain tube annulus having the same length, heat transfer surface
area, volume flow rate, and Reynolds number. They observed that at Prandtl numbers less than 2, the use
of fins may not be justified because the increase in pressure drop is more pronounced than the increase
in heat transfer. At a Reynolds number of 1000 and A Prandtl number of 5, the heat transfer increases by
a factor of 3.1, while the pressure drop increases by a factor of 2.3.
16 | P a g e
Soliman et al. studied steady, laminar, forced convection heat transfer in the thermal entrance
region of internally finned tubes for the case of fully developed hydrodynamics. Results were presented
for 16 geometries including the local Nusselt number and developing length corresponding to each
boundary condition. These results indicate that internal finning influences the thermal development in a
complicated way, which makes it inappropriate to extend the smooth tube results to internally finned
tubes on a hydraulic diameter basis. Totala et al. conducted experiments in a double pipe heat exchanger
by providing threads in the inner pipe. They observed that Nusselt number, heat transfer coefficient were
increased for the threaded pipe. But the pumping power required also increased compared to the plain
tube. Khannan et al. studied the heat transfer through a double pipe heat exchanger with annular fins.
Three different configurations annular ring, spiral rod and rectangular projection were considered on the
outside surface of the outer tube. Experiments were done with varied mass flow rates. It was observed
that heat transfer rate was increased for a finned tube. Fin with annular ring showed better performance
than other methods. Nagarani et al. used circular and elliptical annular fins as a heat enhancement devise
in a double pipe heat exchanger. It was observed that heat transfer rate was higher in elliptical fins than
circular fins. Heat transfer coefficient depends on the fin spacing, flow condition and fluid properties.
Fin efficiency was higher for elliptical fins. Mir et al. studied Numerical simulation of the steady,
laminar, forced convection heat transfer in the finned annulus for the case of fully developed
incompressible flow corresponding to thermal boundary condition of uniform heat input per unit axial
length with peripherally uniform temperature at any cross section. Various heat transfer and fluid flow
characteristics were investigated for a range of values of the ratio of radii of inner and outer pipes, fin
height and number of fins. The results calculated are in good comparison with the correlation results
with considerable gain in the computational time. Syed et al. numerically simulated the laminar
convection flow in the fully developed region of finned double pipe subjected to constant heat flux
boundary conditions. They found a significant enhancement in heat transfer rate and also nusselt
number. For small number of fins fin geometries like fin height, ratio of radii, and half fin angle were
found to be less influential. Iqbal et al. investigated optimal configuration of finned annulus with
parabolic, triangular and trapezoidal fins using finite element methods and genetic algorithms. They
concluded that no single fin shape is best in all situations and for all criteria. Zhang et al. studied heat
transfer enhancement for shell side of a double-pipe heat exchanger with helical fins and pin fins, the
three-dimensional velocity components for the shell side with and without pin fins were measured
experimentally by using laser Doppler anemometer (LDA) under cylindrical coordinate system
17 | P a g e
and the fluid flow characteristics. The results showed that, for the shell side only with helical fins
at large pitch, there was a pair of vortex near the upper and lower edge of the rectangular cross section
the weakest secondary flow occurred at the center. By pin fins being installed, the three-dimensional
velocity components in the helical channel were strongly changed. Patel et al. simulated the industrial
experimental results of a double pipe heat exchanger using ANSYS14-CFX. Results indicated heat
transfer, pressure drop, pumping power increased with mass flow rate whereas friction factor decreased.
For heat exchangers, built with many fins and designed for real industry, it is important to pay attention
to and calculate the heat transfer considering the fluid flow and flow paths. The resistance of the body
results in a pressure drop. Literature survey reveals that most of the analysis was done by considering
constant heat flux or constant wall temperature boundary condition. Literature regarding the numerical
study of enhancement in heat transfer characteristics using different configurations of internal
longitudinal fins for a double pipe heat exchanger with conjugate heat transfer is still scare. Hence the
present work aimed at comparison of heat transfer characteristics using different mass flow rate and
temperature for parallel and counter flow of a double pipe heat exchanger under various operating
conditions to evolve with the best possible configuration. Numerical
commercial CFD package. Heat transfer characteristics like temperature variation, heat transfer rate, and
heat transfer coefficient for the above said models were compared and are presented.
18 | P a g e
tool to model fluids ,but even with the most state of art supercomputers and technological advances they
are only an approximation of what would occur in reality.
It is unclear exactly when computational fluid dynamics came into being. Lewis Fry Richardson
attempted to predict the weather by creating a grid in physical space and using Bjerkne primitive
differential equation. His method involved a stadium of 64,000 people each using a mechanical
calculator to solve part of the flow equation. It ended in failure.
In 1933 A. Thom was able to numerically compute flow past a cylinder. Another mechanical
solution was made by K. Kawaguti which took 20 hours a week over 18 months. NASAs theoretical
division also made contributions during 1960, but it wasnt until the 1980s when commercial methods
for computational fluid dynamics became available.
Fluid flow is classified as external and internal , depending on whether the fluid is forced to flow
over a surface or, in a conduit. Fluid flow in circular and non-circular pipes is commonly encountered in
practice. The hot and cold water that we use in our homes is pumped through pipe. Water in a city is
distributed by extensive piping network. Oil and natural gas are transported hundreds of miles by large
pipelines. Blood is carried throught our bodies by arteries and veins. The cooling water in an engine is
transported by hoses to the pipes in radiator where it is cooled as it flows.
Thermal energy in a hydronic space heating system is transferred to the circulating water in the
boiler and then it is transported to the desired location through pipes.
So it can be seen that many of the industrial processes have to deal with flow through pipe. If
analysis and simulation of flow through pipe is done well than many of the industrial problems can be
understood and solved using the results obtained. Hence in the project incompressible flow through
Double pipe HEX , is simulated using CFD code software ANSYS FLUENT 12.1 .
is
about
numerical
transport.phenomenon.Computational
aerospace,biomedical,automobile,
fluid
chemical
simulation
is
applied
of
in
governing
many
equations
fields
industry,electronics,marine
of
for
science
some
like
engineering,material
19 | P a g e
processing,micro fluids,turbo machines etc.Fluent is a CFD code used for flow modeling
applications.Fluent
needs some input data and domain drawn from various softwares like
GAMBIT,CATIA,PRO-E and other design software.Now fluent can analyze the given domain with
boundary conditions and
solve the governing equations for the flow giving the different flow
The project basically deals with turbulent flow of water through a double pipe.It also contains heat
transfer and single phase flow.
u
v
0
x
y
( For 2D incompressible flow)
20 | P a g e
2u 2 u
u
u
u
p
u
v
2
2
t
x
y
x
y
x
(for 2D incompressible flow in X-direction)
T
T
T
K 2T 2T
u
v
t
x
y CP x 2 y 2
Thus, heat transfer can be tightly coupled to the fluid flow solution
Additionally:
T
c
k 2T q&
t
( rate of change of temperature)
(heat generation)
21 | P a g e
Convection is movement of heat with a fluid, E.g., when cold air sweeps past a warm body, it
draws away warm air near the body and replaces with cold air.
often, we want to know the heat transfer coefficient, h
q h (Tbody T ) h T
h
average heat transfer coefficient (W/m2-K)
Natural convection
fluid moves due to buoyancy
1
4
h T ,
h T
1
3
Forced convection
flow is induced by external means
h const
Boiling convection
h T2
Energy Equation:
22 | P a g e
T
u T k 2T q&
t
q
k
T
Tw T Tw T y
y 0
The fluid flow and heat transfer problems can be tightly coupled
Reynolds Analogy:
It is desirable to have a relation between Cf and Nu, so we can calculate one while other is
available.
Such relationship are developed on the basis of similiarity between momentum and heat transfer
in boundary layers, are known as Reynolds Analogy.
Cf, x Re2 l
= Nux
( Pr = 1)
23 | P a g e
Cfx
=Stx
2
(Pr =1)
where,
h
Nu
Stx =
=
CpV
Re P r
is stanton number, which is also a dimensionless heat transfer coefficient.
24 | P a g e
CHAPTETR 3
CFD ANALYSIS
25 | P a g e
Computational fluid dynamics (CFD) study of the system starts with the construction of desired
geometry and mesh for modeling the dominion. Generally, geometry is simplified for the CFD studies.
Meshing is the discretization of the domain into small volumes where the equations are solved by the
help of iterative methods. Modeling starts with the describing of the boundary and initial conditions for
the dominion and leads to modeling of the entire system. Finally, it is followed by the analysis of the
results, conclusions and discussions.
3.1 Geometry:
Heat exchanger is built in the ANSYS workbench design module. It is a counter-flow heat
exchanger. First, the fluid flow (fluent) module from the workbench is selected. The design modeler
opens as a new window as the geometry is double clicked.
3.1.1 Sketching:
Out of three plane viz, XY-plane, YZ-plane and ZX-plane, the XY plane is selected for the first
sketch. A circle of dia meter 9.5mm is drawn by selecting circle in sketching tab menu. Similarly by
selecting again xy plane we draw another sketch with two circle having diameter 9.5mm and 11mm, by
repeating this process we create sketch no.3 and sketch no.4 having diameter of 28.5mm and 30.5mm
respectively.
3.1.2 Extrude:
By selecting first sketch in xy plane extrude it up to a length of 1600mm. again select another
sketch Extrude it up to 1600mm and change operation from add material to add frozen. Similarly
extrude sketch 3 and sketch 4 upto 1600mm length in z-direction and change operation add material to
26 | P a g e
add frozen. By extrudeing whole body and by changing operation from add material to add frozen we
have four different parts and four bodies.
State Type
Fluid
Solid
Fluid
Solid
27 | P a g e
Initially a relatively coarser mesh is generated. This mesh contains mixed cells (Tetra and
Hexahedral cells) having both triangular and quadrilateral faces at the boundaries. Care is taken to use
structured hexahedral cells as much as possible. It is meant to reduce numerical diffusion as much as
possible by structuring the mesh in a well manner, particularly near the wall region. Later on, a fine
mesh is generated. For this fine mesh, the edges and regions of high temperature and pressure gradients
are finely meshed.
3.2.1 y+ Values:
y + values play a significant role in turbulence modeling for the near wall treatment. y + is a nondimensional distance. It is frequently used to describe how coarse or fine a mesh is for a particular flow
pattern. It determines the proper size of the cells near domain walls. The turbulence model wall laws have
limitations on the y+ value at the wall. For instance, the standard K-epsilon model requires a wall y + value
between approximately 300 and 100. A faster flow near the wall will produce higher values of y +, so the grid
size near the wall must be decreased. y + values for different wall treatments are given in table 2.
Recommended Y+ value
30<y+<400
30<y+<100
y+ = 1
29 | P a g e
3.3.2 Models:
Energy is set to ON position. Viscous model is selected as k- model (2 equation).
3.3.3 Materials:
The create/edit option is clicked to add water-liquid and copper to the list of fluid and solid
respectively from the fluent database.
30 | P a g e
Boundary
Turbulent
Hydaullic
Temperature
Hot inlet
Hot outlet
Cold inlet
Cold outlet
condition type
Mass flow inlet
Pressure outlet
Mass flow inlet
Pressure outlet
manitude
0.02 kg/s
0.02 kg/s
-
intensity
4.6 %
4.6 %
3.6 %
3.6 %
diameter
9.5 mm
17.5 mm
-
360 k
300 k
-
Then the solution initialization method is set to Standard Initialization whereas the reference
frame is set to Relative cell zone. The inner inlet is selected from the compute from drop down list and
the solution is initialized.
Table 4 Residuals
Variable
Residual
X-Velocity
10-6
Y-Velocity
10-6
Z-Velocity
10-6
Continuity
10-6
32 | P a g e
10-5
energy
Turbulent kinetic energy
10-5
Energy
10-9
CHAPTER 4
RESULT AND DISCUSSION
33 | P a g e
4.1Contours:
34 | P a g e
The temperature, pressure and velocity distribution along the heat exchanger can be seen through
the contours.
35 | P a g e
37 | P a g e
38 | P a g e
39 | P a g e
Figure 10: Plot of surface nusselt no. for parallel flow hex
Table 8: Comparison Of Surface Nusselt No.
Surface nusselt no.
Interface 1 (solid inner)
Interface 4 (solid outer)
Parallel hex
144
123
Counter hex
802
675
40 | P a g e
Figure 11: Plot of surface nusselt no. for counter flow hex
XY-PLOT OF TEMPERATURE:
XY-PLOT OF VELOCITY:
44 | P a g e
45 | P a g e
CHAPTER 5
CONCLUSION
Conclusion:
46 | P a g e
A CFD package (ANSYS FLUENT 12.1) was used for the numerical study of heat transfer
characteristics of a double pipe heat exchanger for parallel flow and counter flow, and the results were
then compared . The study showed that there is not much difference in the heat transfer within the error
limits performances of the parallel-flow configuration and the counter-flow configuration. Nusselt
number at different points along the pipe length was determined from the numerical data. The simulation
was carried out for water to water heat transfer characteristics .and for same length and same diameter of
tube and annulus and for same input temperature for cold inlet 300k, for hot inlet 360k . We analyse that
in counter flow heat exchanger there is high temperature difference in output streams (hot outlet, cold
outlet). Nusselt number for the counter flow heat exchanger 802 and for parallel flow is 144.
For the given design and length of the heat exchanger heat transfer enhancement in a double pipe
heat exchanger is possibly achieved by several methods. These techniques are divided into active and
passive techniques. Active methods involve some external input for the enhancement of heat transfer
like induced vibrations, injection and suction of fluids and jet impingement etc. Another method is the
passive method without the stimulation by external power such as surface coating, surface roughness
and extended surfaces.
REFERENCES:
47 | P a g e
48 | P a g e