MINIMUM WIDTH OF AN EXIT DOOR

MINIMUM FLOOR TO CEILING HEIGHT

MAXIMUM STAIR RISE FOR CLASS A STAIR

MAXIMUM HEIGHTS BETWEEN LANDINGS FOR


A CLASS A STAIR

MINIMUM HEADROOM FOR CLASS A AND B


STAIRS.

UNIT AREA PER PERSON FOR WAITING AREAS


OR STANDING ROOM

NUMBER OF EXITS FOR PLACE OF ASSEMBLY


FOR 1000 OCCPANTS

TRAVEL DISTANCE TO AN EXIT WITHOUT FIRE


SPRINKLER SYSTEM

TRAVEL DISTANCE TO AN EXIT WITH FIRE


SPRINKLER SYSTEM

MINIMUM SPACING OF ROWS OF SEATS FROM


BACK TO BACK FOR A PUBLIC ASSEMBLY
BUILDING

MAXIMUM NUMBER OF SEATS IN A ROW


BETWEEN AISLES

MAXIMUM NUMBER OF SEATS IN A ROW


OPENING TO AN AISLE ON ONE SIDE

STANDARD WIDTH OF A SEAT WITHOUT


DIVIDING ARMS FOR PLACES OF ASSEMBLY

MINIMUM WIDTH OF AN AISLE SERVING AN


OCCUPANT LOAD OF 60

MINIMUM HEADROOM CREATED BY ANY


PROJECTION FROM THE CEILING

MINIMUM CLEAR WIDTH OF TURNSTILES

MINIMUM DIRECTION WIDTH OF LANDINGS IN


THE DIRECTION OF TRAVEL FOR CLASS A AND
B STAIRS.

MINIMUM NUMBER OF RISERS IN ANY ONE


FLIGHT OF STAIRS.

MINIMUM HEIGHT OF A HANDRAIL ABOVE THE


UPPER SURFACE OF THE TREAD

MINIMUM CLEARANCE OF A HANDRAIL FROM


ANY WALL

MINIMUM HEIGHT OF A GUARDRAIL

MAXIMUM HEIGHT OF A GUARDRAIL

MINIMUM INNER RADIUS OF A MONUMENTAL


STAIR

MINIMUM WIDTH OF ANY BALCONY OR


BRIDGE.

MINIMUM WIDTH OF ANY CLASS A RAMP.

MAXIMUM RISE OF ANY FLOOR FROM THE


BALCONY TO WHICH AN ACCESS DOOR LEADS.

MAXIMUM VERTICAL HEIGHT IN FLOORS OF AN


ESCALATOR.

MINIMUM WIDTH OF A FIRE ESCAPE STAIR FOR


EXISTING STAIRS.

MINIMUM WIDTH OF A LANDING FOR A FIRE


ESCAPE STAIR FOR EXISTING STAIRS

MINIMUM TREAD FOR FIRE ESCAPE STAIR OF A


SMALL BUILDING

MAXIMUM RISE FOR FIRE ESCAPE STAIR OF A


SMALL BUILDING

MAXIMUM RISE FOR FIRE ESCAPE STAIR OF


EXISTING STAIRS

MAXIMUM RISE FOR FIRE ESCAPE STAIR OF


EXISTING STAIRS

MAXIMUM HEIGHT BETWEEN LANDINGS OF A


FIRE ESCAPE STAIR FOR EXISTING STAIRS.

MINIMUM HEADROOM CLEARANCE FOR FIRE


ESCAPE STAIRS FOR EXISTING STAIRS.

MINIMUM HEADROOM CLEARANCE FOR FIRE


ESCAPE STAIRS FOR SMALL BUILDINGS

NUMBER OF EXITS FOR PLACE OF ASSEMBLY FOR


600-1000 OCCUPANTS

MAXIMUM OCCUPANT LOAD FOR CLASS C


PUBLIC ASSEMBLY

MINIMUM NUMBER OF EXITS FOR AN


INSTITUTIONAL TYPE OF STRUCTURE

MAXIMUM TRAVEL DISTANCE BETWEEN ROOM


DOOR INTENDED AS EXIT ACCESS AND EXIT
WITH SPRINKLER SYSTEM FOR INSTITUTIONAL
USE.

MAXIMUM TRAVEL DISTANCE FROM DOOR OF


ANY ROOM TO EXIT FOR HOTELS WITH
SPRINKLER

MAXIMUM TRAVEL DISTANCE FROM MAIN


ENTRANCE DOOR TO EXIT FOR APARTMENTS
WITH SPRINKLER

MAXIMUM INCREASE IN WIDTH FOR AN AISLE


PER LINEAR METER

MINIMUM WIDTH OF AN AISLE SERVING AN


OCCUPANT OF 60 OR MORE SERVING ONE SIDE
OF A PUBLIC ASSEMBLY BUILDING

MINIMUM WIDTH OF AN AISLE SERVING AN


OCCUPANT OF 60 OR MORE SERVING TWO
SIDES OF A PUBLIC ASSEMBLY BUILDING

MINIMUM WIDTH OF AN AISLE SERVING AN


OCCUPANT OF BELOW 60 FOR A PUBLIC
ASSEMBLY BUILDING

MINIMUM WIDTH OF AN AISLE FOR AN


EDUCATIONAL USE BUILDING

MINIMUM WIDTH OF AN AISLE FOR HOSPITALS


OR NURSING HOMES.

MINIMUM WIDTH OF AN AISLE FOR CUSTODIAL


CARE INSTITUTIONS.

MINIMUM WIDTH OF AN AISLE FOR BUSINESS


USE STRUCTURE

MINIMUM WIDTH OF AN AISLE FOR AN


INDUSTRIAL BUILDING

OCCUPANT LOAD PER PERSON FOR


LABORATORIES

JAILS ARE CLASSIFIED UNDER WHAT TYPE OF


OCCUPANCY?

COURTROOMS WITH AN OCCUPANT LOAD OF


MORE THAN 100 ARE CLASSIFIED UNDER
WHAT CLASSIFICATION OF OCCUPANY?

ARMORIES WITH AN OCCUPANT LOAD OF MORE


THAN 100 ARE CLASSIFIED UNDER WHAT
CLASSIFICATION OF OCCUPANCY?

LIBRARIES ARE CLASSIFIED UNDER WHAT


CLASSIFICATION OF OCCUPANCY?

ROOMS WHERE BALED, BUNDLED OR PILED


MATERIALS SEGREGATED INTO DESIRED SIZES
OR GROUPS

BUILDINGS OR STRUCTURES WHICH ARE 15


METERS OR MORE IN HEIGHT?

BUILDINGS OR STRUCTURES USED FOR


STORAGE OF EXPLOSIVES, SHELLS,
PROJECTILE, ETC.

AN AIR COMPARTMENT OR CHAMBER TO WHICH


ONE OR MORE DUCTS ARE CONNECTED AND
WHICH FORM PART OF AN AIR DISTRIBUTION
SYSTEM

A KIND OF STABLE EXPLOSIVE WHICH EXPLODES


BY PERCUSSION

DESCRIPTIVE OF ANY MATERIAL THAT INSTANTLY


IGNITES WHEN EXPOSED TO AIR

MATERIAL THAT READILY YEALDS OXYGEN IN


QUANTITIES SUFFICIENT TO STIMULATE OR
SUPPORT COMBUSTION

A PROCESS WHERE A PIECE OF METAL IS HEATED


PRIOR TO CHANGING ITS SHAPE AND
DIMENSION

THE PROCESS OF FIRST RAISING THE


TEMPERATURE TO SEPARATE THE MORE
VOLATILE FROM THE LESS VOLATILE PARTS
AND THEN COOLING AND CONDENSING THE
RESULT VAPOR AS TO PRODUCE A NEARLY
PURIFIED SUBSTANCE.

A FINELY POWDERED SUBSTANCE WHICH WHEN


MIXED WITH AIR IN THE PROPER PROPORTION
AND IGNITED WILL CAUSE AN EXPLOSION

TEMPERATURE RATING AT FLASH POINT

CLASS OF FIRE WITH FLAMMABLE LIQUID AND


GASSES

TEMPERATURE AT WHICH LIQUID IS


TRANSFORMED INTO VAPOR

MINIMUM FIRE RESISTANCE RATING FOR FIRE


WALL

CONTINUOUS PASSAGEWAY FOR THE


TRANSMISSION OF AIR

MINIMUM TEMPERATURE AT WHICH MATERIAL


GIVES OFF VAPOR IN SUFFICIENT
CONCENTRATION TO FORM AN IGNITABLE
MIXTURE WITH AIR

A GAS, FUME OR VAPOR USED FOR THE


DESTRUCTION OR THE CONTROL OF INSECTS,
FUNGI, VERMIN, GERMS, RODENTS OR OTHER
PESTS.

MINIMUM WIDTH OF ANY DRIVEWAY IN AND


AROUND A LUMBER YARD/ PILES

MINIMUM HEIGHT OF FENCE FOR A LUMBER


YARD FOR EXTERIOR STORAGE OF LUMBER

MAXIMUM WIDTH OF SUMPS FOR THE


RETENTION OF OIL AND PETROLIUM
PRODUCTS. FOR REFINERIES, DISTILLERIES,
AND CHEMICAL PLANTS, MINIMUM HEIHT OF
FENCE

MINIMUM TRAVEL DISTANCE FROM ANY


INDIVIDUAL ROOM SUBJECT TO OCCUPANCY
BY NOT MORE THAN 6 PERSONS

MAXIMUM DISTANCE OF TRAVEL FROM THE HIGH


HAZARD AREA TO AN EXIT.

MINIMUM DISTANCE OF AN INCINERATOR FROM


ANY STRUCTURE USED OTHER THAN A SINGLE
FAMILY DWELLING.

MAXIMUM REDUCTION OF WIDTH OF A STAIR BY


A HANDRAIL.

MINIMUM WIDTH OF A SINGLE DOOR IN A


DOORWAY

MAXIMUM CHANGE IN ELEVATION BETWEEN THE


INTERIOR OF A DOOR TO THE OUTSIDE IF ITS
OTHER THAN A BALCONY

MAXIMUM FORCE IN KILOGRAMS REQUIRED FOR


A PANIC HARDWARE

MAXIMUM HEIGHT REQUIRED FOR A PANIC


HARDWARE

MINIMUM HEIGHT REQUIRED FOR A PANIC


HARDWARE

MAXIMUM NUMBER OF OCCUPANTS FOR A


SUBDIVIDED ROOM OR SPACE BY A FOLDING
PARTITION

MINIMUM WIDTH OF A DOOR FOR FAMILY


DAYCARE HOMES

MINIMUM STAIR WIDTH FOR CLASS B STAIRS


HAVING AN OCCUPANT LOAD OF MORE THAN
50 OCCUPANTS

IN EXIT HALLWAYS THE WIDTH OF A HALLWAY


SHOULD NOT BE REDUCED BY MORE THAN
_________ CONSIDERING AN OPENED DOOR

LENGTH OF NOSING OR EFFECTIVE PROJECTION


OVER THE LEVEL IMMEDIETLY BELOW IT FOR
TREAD BELOW 25 CM IN DIMENSION

MAXIMUM HEIGHT OF HANDRAIL

COMBUSTIBLE LIQUIDS ARE LIQUIDS HAVING A


FLASH POINT OF OR ABOVE

THE TIME DURATION THAT A MATERIAL OR


CONSTRUCTION CAN WITHSTAND THE EFFECT
OF STANDARD FIRE TEST IS KNOWN AS

ANY MATERIAL WHICH BY ITS NATURE OR AS A


RESULT OF ITS REACTION WITH THE OTHER
ELEMENTS PRODUCES A RAPID DROP IN
TEMPERATURE OF THE IMMEDIATE
SURROUNDING.

THE TRAVEL DISTANCE TO EXITS SHALL BE FOR


MERCANTILE OCCUPANCIES.

UNDER WHAT CLASSIFICATION OF OCCUPANCY


DOES POOL ROOMS FALL

UNDER WHAT CLASSIFICATION OF OCCUPANCY


DOES HOME FOR THE AGED FALL?

UNDER WHAT CLASSIFICATION OF OCCUPANCY


DOES COURT HOUSES FALL?

UNDER WHAT CLASSIFICATION OF OCCUPANCY


DOES REFINERIES FALL?

UNDER WHAT CLASSIFICATION OF OCCUPANCY


DOES DRUGSTORES FALL?

MINIMUM WIDTH OF AN AISLE FOR MERCANTILE


OCCUPANCIES?

MINIMUM NUMBER OF AISLES FOR CLASS A


STORES?

MINIMUM CLEAR WIDTH OF AISLES FOR CLASS A


STORES?

MINIMUM CLEAR WIDTH OF EXITS THROUGH A


COVERED MALL?

MINIMUM HEIGHT OF BUILDINGS REQUIRING


AUTOMATIC SPRINKLER PROTECTION?

STANDARD INNER RADIUS OF A CURVED STAIR IN


BUSINESS OCCUPANCIES?

MAXIMUM HEIGHT OF RISER FOR CLASS A


STAIRS?

MAXIMUM HEIGHT OF RISER FOR CLASS B


STAIRS?

MINIMUM WIDTH OF CLASS B STAIRS SERVING


MORE THAN 50 PERSONS?

MINIMUM WIDTH OF CLASS B STAIRS SERVING


50 PERSONS AND BELOW?

MINIMUM WIDTH OF CLASS A STAIRS?

MAXIMUM PROJECTION OF A HANDRAIL OVER A


STAIR?

MINIMUM HEIGHT BETWEEN LANDINGS FOR


CLASS B STAIRS?

MINIMUM WIDTH OF LANDINGS IN DIRECTION


OF TRAVEL FOR CLASS A AND B STAIRS?

MINIMUM WIDTH OF CLASS A RAMP?

MINIMUM WIDTH OF CLASS B RAMP?

STANDARD SLOPE OF CLASS B RAMP IN


PERCENTAGE?

MAXIMUM HEIGHT BETWEEN LANDINGS FOR A


CLASS A RAMP?

MAXIMUM HEIGHT BETWEEN LANDINGS FOR A


CLASS B RAMP?

MINIMUM WIDTH OF RAMPS FOR 3 OR MORE


STORIES IN HEIGHT?

MINIMUM WIDTH FOR FIRE ESCAPE FOR


EXISTING STAIRS?

MINIMUM HORIZONTAL DIMENSION OF ANY


LANDING OR PLATFORM FOR EXISTING STAIRS
FOR FIRE ESCAPE?

MAXIMUM RISE FOR FIRE ESCAPE IN SMALL


BUILDINGS?

MAXIMUM HEIGHT BETWEEN LANDINGS FOR


FIRE ESCAPE FOR EXISTING STAIRS?

MINIMUM DISTANCE OF TRAVEL TO AN EXIT FOR


STORAGE OF HIGH HAZARD COMMODITIES?

CLASS OF FIRE INVOLVING COMBUSTIBLE


METALS, SUCH AS MAGNESIUM, SODIUM,
POTASSIUM, AND OTHER SIMILAR MATERIALS?

CLASS OF FIRE INVOLVING COMBUSTIBLE


MATERIALS, SUCH AS WOOD, PAPER, CLOTH,
RUBBER AND PLASTICS?

A TANK VAT OR CONTAINER OF FLAMMABLE OR


COMBUSTIBLE LIQUID IN WHICH ARTICLES OR
MATERIALS ARE IMMERSED FOR THE PURPOSE
OF COATING, FINISHING, TREATING OR
SIMILAR PROPERTIES?

AN INTEGRATED SYSTEM OF UNDERGROUND OR


OVER HEAD PIPING OR BOTH CONNECTED TO
A SOURCE OF EXTINGUISHING AGENTS OR
MEDIUM AND DESIGNED IN ACCORDANCE WITH
FIRE PROTECTION ENGINEERING STANDARDS
WHICH WHEN ACTUATED BY ITS AUTOMATIC
DETECTING DEVICE, SUPPRESSES FIRE WITHIN
THE AREA PROTECTED

A CONTINUOUS AND UNOBSTRUCTED ROUTE OF


EXIT FROM ANY POINT IN A BUILDING TO A
PUBLIC WAY

MINIMUM DISTANCE OF AN INCINERATOR


CONTAINING KINDLED FIRE OR RUBBISH FIRE
OR BONFIRES

UNDER WHAT CLASSIFICATION DO MUSEUMS


FALL UNDER?

UNDER WHAT CLASSIFICATION DO TOWN HALLS


FALL UNDER?

MAXIMUM WIDTH OF A SINGLE DOOR IN A


DOORWAY?

MINIMUM TREAD FOR FIRE ESCAPE STAIRS FOR


EXISITING STAIRS?

MAXIMUM SPACING OF RUNGS FOR A FIRE


ESCAPE LADDER?

MINIMUM SPACING OF RUNGS FOR A FIRE


ESCAPE LADDER?

CLASS III COMBUSTIBLE LIQUIDS SHALL MEAN


ANY LIQUID HAVING A FLASH POINT AT HOW
MANY DEGREES CELSIUS?

IN STANDARD SEATING MINIMUM SPACING BACK


TO BACK

MINIMUM SPACE FROM THE BACK OF A CHAIR TO


THE FRONT OF THE CHAIR BEHIND

MAXIMUM SLOPE FOR AISLES FOR PUBLIC


ASSEMBLY STRUCTURES

SIZE OF STANDPIPE PROVIDED FOR EACH STAGE


FOR PUBLIC ASSEMBLY BUILDING

OCCUPANT LOAD PER PERSON FOR


CLASSROOMS

WHERE EXTERIOR CORRIDORS OR BALCONIES


ARE PROVIDED AS MEANS OF EXIT, THEY
SHALL OPEN TO THE OUTSIDE AND SHALL BE
SPACED ______ METERS APART.
(EDUCATIONAL)

MINIMUM DIMENSION OF A RESCUE WINDOW


FOR EDUCATIONAL OCCUPANCIES

MAXIMUM HEIGHT FROM THE FLOOR FOR A


RESCUE WINDOW FOR EDUCATIONAL
OCCUPANCIES

MINIMUM WIDTH OF CORRIDORS, AISLES, AND


RAMPS FOR EXITS IN HOSPITALS AND NURSING
HOMES

MINIMUM WIDTH OF CORRIDORS, AISLES, AND


RAMPS FOR EXITS IN RESIDENTIAL CUSTODIAL
CARE

ANY ROOM FOR SLEEPING IN INSTITUTIONAL


OCCUPANCIES IF SUBDIVIDED SHALL HAVE A
MAXIMUM AREA OF HOW MANY SQUARE
METERS.

INCLUDES BUILDINGS OR GROUPS OF BUILDING


UNDER THE SAME MANAGEMENT IN WHICH
THERE ARE MORE THAN 15 SLEEPING
ACCOMODATIONS FOR HIRE.

INCLUDES BUILDINGS CONTAINING THREE OR


MORE LIVING UNITS INDEPENDENT COOKING
AND BATHROOM FACILITIES, WHETHER
DESIGNED AS ROWHOUSE, APARTMENT
HOUSE, TENEMENT, GARDEN APARTMENT, OR
BY ANY OTHER NAME.

MINIMUM NUMBER OF STORIES OF APARTMENT


BUILDINGS REQUIRING FIRE ALARM SYSTEM

MINIMUM NUMBER OF APRTMENT UNITS


REQUIRING A FIRE ALARM SYSTEM