Sei sulla pagina 1di 1

BPC capacity is 192 CE

BPK capacity is 384 CE

http://www.slideshare.net/shirazthegreat/09-gu-ss1021-e021-zxsdr-btsintroduction59

Re: What is a CE (Channel Element)?


Clear Definition is
"A band Channel Element is the resource base required in the Node-B to Provide for one voice channel capacity, including
the control plane to Provide for one voice channel capacity, including the control plane signaling, compressed mode, the
transmit diversity and softer handover. "signaling, compressed mode, the transmit diversity and softer handover."
Factors affecting capacity in WCDMA UL and DL, sorted by descending level of importance as follows: Factors affecting
Capacity in WCDMA UL and DL, sorted by descending level of Importance as Follows:
- UL: No. CE support on each Node B, interference, Node B sensivity, .. - UL: No. CE support on the each Node B, interference,
Node B sensivity, ..
- DL: No. CE support on each Node B Iub interface capacity, power DL, OVSF, ... - DL: No. CE support on the each Node B Iub
interface capacity, power DL, OVSF, ...
Thus, CE can be viewed as a license for each NodeB capacity (not more). Thus, CE can be viewed as a license for each vertex
NodeB capacity (not more).
Each service will need some different CE UL and DL, such as: the each service will need some Different CE UL and DL, such as:
AMR 12.2 k: Uplink 1; downlink AMR 12.2 k 1: Uplink 1; downlink 1
CS / PS 64 K: 3 Uplink, downlink 2 CS / PS 64 K: 3 Uplink, downlink 2
PS 128/144k: Uplink 5; downlink 128/144k PS 4: Uplink 5; DL 4
384 k PS: Uplink 10, downlink 8384 k PS: Uplink 10; downlink 8
CE is a basic unit that measures the channel demodulation capabilities of a NodeB. CEs are classified into uplink (UL) CEs and
downlink (DL) CEs.
One UL CE needs to be consumed by a UL 12.2 kbit/s voice service (SF = 64) plus 3.4 kbit/s signaling.
One DL CE needs to be consumed by a DL 12.2 kbit/s voice service (SF = 128) plus 3.4 kbit/s signaling