Sei sulla pagina 1di 1

11

12

10

PL

APPROXIMATE EXISTING GAS VENT, TYPICAL.

PL

SYSTEM SUMMARY

PL

MODULE POWER (Wp)

325

NUMBER OF MODULES

3060

RATED DC POWER (kWp)

994.5

INVERTER AC CAPACITY (kWAC)

742.4

PROPOSED ARRAY FENCE


PROPOSED PV ARRAY

AC

AC

AC

AC

PL

PROPOSED GRAVEL
ACCESS DRIVE

LEGEND

AC

AC

TRANSITION FROM
ABOVE GROUND TO
UNDERGROUND OFF OF
THE LANDFILL

AC

APPROXIMATE VENT PIPE WITH 15FT RADIUS SETBACK


APPROXIMATE EXISTING PROPERTY LINE

AC

PL

PL

PL

APPROXIMATE EXISTING OVERHEAD ELECTRIC CIRCUIT


UG

F
MV

MV

MV

PROPOSED UNDERGROUND MEDIUM VOLTAGE CIRCUIT

OE

OE

OE

PROPOSED OVERHEAD ELECTRIC CIRCUIT

AC

AC

AC

PROPOSED LV ABOVE GROUND ELECTRIC CIRCUIT

UG

UG

UG

PROPOSED LV UNDERGROUND ELECTRIC CIRCUIT

UG

PROPOSED
ENTRANCE

UG

UG

PL

UNDERGROUND FEEDERS
TO EQUIPMENT PAD

PL

PROPOSED
INVERTER,
EQUIPMENT, AND
TRANSFORMER
PADS

APPROXIMATE EXISTING ELECTRICAL UTILITY POLE


MV

MV

APPROXIMATE
EXISTING WELL
LOCATION,
SETBACK TBD

APPROXIMATE
EXISTING POLE, RISER
POLE, GENERATOR
ISOLATION SWITCH

PL

E
PROPOSED RACK - (2) VERTICAL ROWS OF 9 MODULES

PL

MV

ISSUED FOR INTERCONNECTION


NOT FOR CONSTRUCTION

NEW METER POLE,


NATIONAL GRID METER

PL

NOTES
LINE EXTENSION BY
GROSOLAR

1.

APPROXIMATE EXISTING POLE,


POINT OF INTERCONNECTION AND
POCC, UTILITY ISOLATION SWITCH

PL

SITE SPECIFIC FACTORS SUCH AS: TOPOGRAPHY,


SHADING, ACCESS DRIVES, DRAINAGE, EXISTING
BUILDINGS, PV EQUIPMENT, PAD LOCATIONS, AND OR
UTILITY INTERCONNECTION AREA COULD CHANGE THE
FINAL ARRAY LAYOUT AND POWER OUTPUT.

PL

PL

PROJECT

C
B
A
REV

REVISED AND REISSUED FOR INTERCONNECTION


UPDATED LAYOUT, NEW EQUIPMENT TRANSFORMER AREA
ISSUED FOR REVIEW
DESCRIPTION

TOWN OF CLIFTON PARK SOLAR

05-19-2015
03-26-2015
02-10-2015
DATE

LOCATION

CHK BY

REVISIONS

12

11

10

THE ARRAY ROW SPACING SHOWN WILL PREVENT


SHADING BETWEEN 10AM-2PM ON DECEMBER 21ST.

3.

SITE PREPARATION AND PRELIMINARY LAYOUT FOR THE


CLIFTON PARK LANDFILL SITE IS BASED ON
INFORMATION PROVIDED BYC.T. MALE ASSOCIATES
ENGINEERING, SURVEYING AND ARCHITECTURE D.P.C.,
FROM DRAWING #15-145, NAMED TOPOGRAPHIC SURVEY
PORTION OF LOT 1 OF TOWN OF CLIFTON PARK LANDFILL
SHEET 1 OF 1, PROJECT #14.4727 LATEST REVISION
DATED 01/ 26/ 2015.

TITLE

205 BILLINGS FARM ROAD, BUILDING 4


WHITE RIVER JUNCTION, VERMONT 05001
800-374-4494
INFO@GROSOLAR.COM

PRELIMINARY SITE PLAN


SIZE

THIS DRAWING AND SPECIFICATIONS CONTAINED HEREON IS PROPRIETARY TO


GROSOLAR AND IS LOANED TO FACILITATE BIDDING, CONSTRUCTION, FABRICATION
AND/OR EXECUTION OF REQUIREMENTS STATED AND IS TO BE SURRENDERED
UPON REQUEST OR COMPLETION OF SERVICES

217 VISCHER FERRY ROAD


CLIFTON PARK, NY 12148

APV BY

2.

D
DRAWN BY
SCALE

PROJECT
NUMBER

DRAWING
NUMBER

TBD

ESB
1 IN = 50 FT

ENGINEERED BY

E-1

JMM
SHEET

A
REV

DATE

05-19-2015
1 OF 1