TEGOSOLAR www.tegolacanadese.com 1
Overlap
TEGOSOLAR
6
PVL68
KIT 2 - L Profiles pre drilled stick with butyl tape 1 - Cap pre drilled for the 2 - Stainless steel screws
TEGOSOLAR protection of cables
PVL68 Cu 2 - Adhesives with small band
Not closer
2 D
than 50 cm
from the valley
3
4 5
288cm 1
288cm
288cm
Fig. 6
288cm 288cm
" Mark a line xy orthogonal to the direction of maximum slope of the roof, usually parallel to the
eaves and to the gutter at 44,5 cm from the gutter (orange line) or more generally at 44,5 cm
from the starting point (i.e. yellow line 2 ). D
" Mark along the line xy a point A. This point must respect the scheme of the electrical project.
" Mark points B e C, at either side from A (for example at 150 cm).
" Starting from B and C, by using a chalk line as a compass, mark point D as near as possible to
the Ridge.
" Join A with D.
" Mark parallel to line AD, at a distance of 288 cm, the lines needed for completing the
installation scheme.
" Starting from the line xy, mark horizontal and parallel lines to the line xy, at a distance of 38,5
cm from each other up to the completing of the installation scheme. (Fig. 6B)
" The parts of the roof not interested in the installation of Tegosolar shall be marked following the
installation instructions of the shingles that shall complete the roof and that shall be installed at
the same time, as per the following instructions.
38,5cm
38,5cm
x B A 38,5cm C y
44,5cm Fig. 6B
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
www.tegolacanadese.com 3
NAILS INSTALLATION Tegosolar: slope limits for installation with nails or torch on
Tegosolar, installed by nails, on a wooden roof deck, becomes a waterproofing layer thanks to the Slope Length of the pitch
overlapping of its elements. This installation method needs a minimal slope of the roof, which has to be of the roof Up to 7 m From 7 to 10 m From 10 to 15 m
related to the length of the pitch. In fact length and slope of the pitch determine the volume of water
More than 40% Nail installation Nail installation Nail installation
which is running on it, and its progressive elongation increases the infiltration risk. Consequently, before
installing with nails, we suggest to have a look at the Table 1. We also remind that these information are From 35% to 40% Nail installation Nail installation
referred to roof decks in a good maintenance status, stable and without subsidence. From 30% to 35% Nail installation
Torch on installation
Up to 30%
Should the slope of the roof and / or its length do not permit to install with nails, the following procedure
shall be done: torch on the surface of the roof (wooden plates, plywood or cement) a plastomeric Tab.1
waterproofing membrane, with polyester reinforcement, 4 mm thick. The membrane shall be selected
with the suitable elongation, according to the type of roof deck. Further than a perfect waterproofing
the selected membrane shall have to assure a good sticking both on the support and on Tegosolar. Left side:
make holes
Right side:
insert the 20 mm nails
Fig.8B
11,4cm 11,4cm
11,4cm 11,4cm
8,4cm 7,3cm
Fig.7 Fig.9
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
NAILS INSTALLATION (1) www.tegolacanadese.com 4
" Place Tegosolar as per Fig. 9, being sure to place it inside the S spacers.
" Nail Tegosolar with 12 large headed roofing nails, stainless steel AISI 304 high adherence, equidistant at abt. 25 cm as per Fig.
Fig.11
96 96 96
BITUSTICK
Fig.12
Partially
remove Fig.13
the transparent film
17 mm
Connection
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
NAILS INSTALLATION (2) www.tegolacanadese.com 5
" Once the starting line for Tegosolar is decided, apply a line of Bitustick at 4-5 cm of that line (Fig. 17), unless there are the thermo or self adhesive points making this function
in that position.
" Place the S spacers at 96 cm from the marking (Fig. 17) paying attention to press the upper side, and fix them with large headed roofing nails, stainless steel AISI 304 high
adherence.
" Place Tegosolar as per Fig. 17, paying attention to place it inside the S spacers.
" Apply Tegosolar with 12 large headed roofing nails, stainless steel AISI 304 high adherence, equidistant at abt. 25 cm as stated in Fig. 17.
" Repeat the same procedure for placing the other Tegosolar right and left, 'till the line is done (Fig. 18).
~ 96 cm ~ 96 cm
Fig.17
Fig.18
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
NAILS INSTALLATION (3) www.tegolacanadese.com 6
Tegosolar will also lay on the L profiles installed before (Fig. 21).
" Apply Tegosolar with 12 large headed roofing nails, stainless steel AISI 304 high adherence, equidistant at abt. 25 cm as stated in
Fig. 21.
" With the same process install Tegosolar right and left 'till the line is done.
the butyl line, once the lower protection is removed, fully adhere and seals the connection between the tiles placed side by side,
and between the lines (Fig. 23). Fig.19
" Fix them with large headed roofing nails, stainless steel AISI 304 high adherence, in correspondence of the holes (Fig. 24).
Fig.20
96 96 96
Fig.21
Remove partially
the transparent film
17 mm
" Install the Tegosolar, following instructions at page 5 and placing the L profile at the right of
connectors, following instructions in fig. 22 23 24 25 in order to obtain what stated in Fig. 26.
" Install the shingles at the left of Tegosolar. The two layers shall be in contact (Fig. 26)
" Place the L profile at the left of connectors, on the shingles (Fig. 26b) Seal
" As per Fig. 27 fix the profiles with 3 large headed roofing nails, stainless steel AISI 304 high adherence,
Fig.27
Fig.26
180 mm
Remove
partially the
transparent film
Fig.25
26B
Connection
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
NAILS INSTALLATION (5) www.tegolacanadese.com 8
" In Abb. 28 shingles and Tegosolar have already been applied respecting the marking of
them both and nails position as well.
" In order to be able to proceed with the waterproofing of the connection it's necessary to
apply the L profile by removing the bottom protection. Let completely adhere the butyl
adhesive on the shingles, also compensating eventual relieves that they make (Abb. 29
29b).
" As per Abb. 29 29b fix the profiles with 3 large headed roofing nails, stainless steel AISI 304
" For completing the connection install the R profile. This profile, in Abb. 30b, is put into the
Abb.28
R PROFILE
dev. 105mm x 1ml
Abb.30 14 10 66
15
Abb.30B
Abb.29 Abb.29B
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
TORCH ON INSTALLATION (1) www.tegolacanadese.com 9
" Pay attention not to direct the flame towards the upper surface of Tegosolar or towards the connectors.
" Remove the protection from the butyl tape of the L profile. Place them paying attention that the holes coincide with the nails arising from Tegosolar (Fig. 33). In this phase
pay attention that the butyl tape fully adhere and seals the connection (Fig. 34).
" Fix the L profiles with the self blocking screws pressing properly (Fig. 35).
Fig.31
Fig.32
17 mm
position.
" Place the first left Tegosolar close to the marking line of the row as per Abb. 36 and apply torching it on. Fully lift up the tail of Tegosolar and warm by flame the membrane's bitumen.
Once it's softened re - place Tegosolar and push it in order to help the adhesion.
" Repeat the above for the other Tegosolar at the right 'till completion of the line (Abb. 37).
" Pay attention not to direct the flame towards the upper surface of Tegosolar or towards the connectors
BITUSTICK
Abb.36
Abb.37
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
TORCH ON INSTALLATION (3) www.tegolacanadese.com 11
Continue the installation of Tegosolar
" Remove the upper film of the pre installed tile (Fig. 38 39)
" Place the two S spacers at 96 cm from the left and right corner of Tegosolar (Fig. 38 39). They have to be embedded into the
Tegosolar will also lay on the L profiles installed before (Fig. 40).
" Fully lift up the tail of Tegosolar and warm by flame the membrane's bitumen. Once it's softened re - place Tegosolar and push it in
" Pay attention not to direct the flame towards the upper surface of Tegosolar or towards the connectors
" Remove the protection from the butyl tape of the L profile. Place them paying attention that the holes coincide with the nails
Fig.38
arising from Tegosolar (Fig. 42). In this phase pay attention that the butyl tape fully adhere and seals the connection between
Tegosolar and Tegosolar and between line and line (Fig. 43).
" Fix the L profiles with the self blocking screws pressing properly (Fig. 43).
Fig.39
96 96 96
Fig.40
Remove partially
the transparent film
17 mm
45.
" The torch on installation of Tegosolar must be done by step because it's necessary to make some
holes into the tile itself, in order to insert then large headed roofing nails, stainless steel AISI 304 high
adherence, for fixing the L profile.
" Place the shingle in connection with the Tegosolar. By means of the L profile locate where to make
long from the back of the tile. Place again the shingle and torch it on (NB. Do not direct the flame
towards Tegosolar).
" Proceed as above for the following shingles (Fig. 46)
" Once the shingles installation is done remove the bottom protection of the L profiles and apply
them. The nails should enter into their holes, and the butyl must adhere both on the shingle and on
Tegosolar in order to waterproof the connection (Fig. 47).
Fig.46
" Seal eventual discontinuities on the surface (Fig. 47).
Fig.45
Seal
Fig.44 Fig.47
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
TORCH ON INSTALLATION (5) www.tegolacanadese.com 13
" In Fig. 48 the shingle and the Tegosolar layers are already installed respecting the marking
and the installation procedures of both products.
" In order to proceed with the waterproofing of the connection it's necessary to apply a L
profile by removing the protection. The nails should enter into their holes, and the butyl must
adhere both on the shingle and on Tegosolar in order to waterproof the connection (Fig. 49
49b).
" Repeat the operation 'till completion of the installing scheme.
" For completing the connection install the R profile. This profile, in Fig. 50b, is put into the
Fig.48
PROFILO R
sv. 105mm x 1ml
Fig.50
14 10 66
15
Fig.50B
Fig.49
Fig.49B
Date 11-04-08 INSTALLATION INSTRUCTIONS D.R.S.2022 Rev.1
INSTALLATION OF THE CAP www.tegolacanadese.com 14
Fig.51
Fig.52