Sei sulla pagina 1di 1

03

1100

03
01

03

250

SECTION C1-C1

GL = 0.00mm

03

03

6T16-03-200c/c
Bothways

NOTES;

1. All dimensions to be read (not scaled) in conjunction with


Architectural drawings.
2. Reinforced Concrete to be grade 25
3. Maximum aggregate size to be 20mm

4. Minimum cover to steel to be 50mm in foundations & 25mm above ground

5. Mass Concrete to be Grade 20 & Blinding to be Grade 15

6.This foundation is designed for founding in soils with a bearing capacity


of 150kPa.

NOTES

Description

Revisions

EAST AFRICA

TRIAD EAST AFRICA


Design & Management,

Plot 915, Block 221,


Shelter road,
Naalya Housing Estates
Kampala
P.O. Box 6313 Kampala, Uganda
TEL: +256(0)41 233851/3
Mobile: +256 772 430070
FAX: +256(0)41 230008
email: triadea@utlonline.co.ug

OR

AS SHOWN AT A1

SK

O.I

AUGUST- 2014

COLUMN GATE DETAILS

JULY 2014

Approved MAY 2014

SK

SK

Checked

JULY 2014

MAY 2014

Date

NPK

NPK

Drawn

C1
4T16-03

75mm Kicker

03

4T16-02

03

550

(Refer to Footing Detail)

03

02

1100

02

02

425

Revision

250

300

03

550

01
02

250

250

GL = 2.10m

2100

425

FOOTING, F1 (2 nos)

Site Dimension
(Minimum 1000mm)

880
75
14R8-01-190LINKS c/c

C1

GL = 0.00m

03
03

11R8-01-190LINKS c/c

SECTION 1-1 thru gate columns (2nos)

400
425
250
425

50 mm Blinding [1:4:8]

1100