Sei sulla pagina 1di 9
Technical Orifice Data Information (Orifice Calculation Data for Various Case) Yokogawa. Attached Yokogawa’s Technical Information has got from Mr. Zeniya who is YTL Managing, Director and transferred from Japanese to English language by myself. Make use of this document accordingly, it is very easy to decide maximum differential pressure range for orifice plate and differential pressure transmitter. Routine work of our instrument section, all of instrument data has been given by some responsibility sections and can be making individual instrument specifications then send them vendor to quote and decide detail data such as orifice’s differential pressure range, calculated CV data — etc. But, given data are not always correct and our section could not check its quickly time that data are correct or not. If we received incorrect data, could not find incorrect point out and not confirm correct data to responsibility sections. At last, flow instrument data for orifice plate, we can check and decide the orifice diameter ratio and differential pressure transmitter range at same time make use of this document. Attached materials 1. Orifice straight runs for checking 2. Permanent pressure loss chart for checking, August 2", 2002 YY. Muto Technical Information Orifice Data (Orifice Calculation Data for Vai us Case) Direction for use Orifice Calculation Chart Ex. 1 Fluid — Liquid ‘Customer Specification Ring Type Orifice : 68 Ring Material : SUS304 Otifice Plate Material : SUS304 Fluid : Pure Water Flow Rate : 160t/h (Nor : 120vh) ‘Temperature : Ambient (20deg.C) Pressure : 1.Okg/em2G Diff, Press : Option (Selected Diff. Transmitter: /I3A-M) Inside Pipe Diameter : 150A SGP, 155.2mm Flange Type : JIS-10K-150A-RF Direction for use Calculation Chart 1) Checking of Reynolds Number (Rp) On the orifice specification, engineering unit of viscosity is mentioned as cP, then this time is not consider using the horizontal auxiliary line of y1 and vL on the Fig. 2 © w-1.0eP, D=155.2mm ‘Two points are on the same line and drawing up to suniliary line, (Ploting Point 47) © Plotting Point 47 and G=1 600 ‘Two points are on the same line and reading Rp 3.710" Calculation by hand for checking, :4*G/Du (G: kg/h, D: mm, w: cP) Ry=354*1.6*10'155.241.0-3.65°10" Therefore, enough Rp then selects the edge orifice plate (Refer to Fig. 4) Aux. Li “ a DG mH, Rom ® ® 2) Checking of square port ratio “mm”. (Fig. 1) © _D=155.2mm and G~160vh ‘Two points are on the same line and plotting up to auxiliary line (a) © Plotted Point and y=998.3kg/m3 ‘Two points are on the same line and plotting up to auxiliary line (b). (Plotting Point: 0.00215 —~ P, ~P;/P,) @ Plotting Point: 0.00215 and select one point differential pressure, then two points are on the same line and reading of “‘m” ratio Here, have to decide the differential pressure Before, when will decide the differential range finally, should consider the following, conditions. 1. Differential pressure range of selecting model type of Differential Pressure Transmitter. 2. Within limits of “m", (“B" is used for ASME Standard, and relation is as Vm-~ Bra). 3. Characteristic of square port ratio “m”. ‘m-> large value: small permanent pressure loss and large coefficient factor. ‘m_— small value: large permanent pressure loss and small coefficient factor. AucLineDig chur Line le) “eo co BB py, 7 em oP This orifice plate has been used for type of differential pressure Y/T3A-M and differential pressure range S00 — 5200mmil20. ‘As center of plotting point 0.00215, “m” value varies from 1.0 t0 0.38. This time, PI ~P2 is 3800mm H2O, then m-0.475 (80.688). Technical Orifice Data Information (Orifice Calculation Data for Various Case) Ex.2 Fluid ‘Customer Specification Ring Type Orifice : 6B Ring Material : SUS304 Orifice Plate Material : SUS304 Fluid: Super Heated Steam Flow Rate: 2500kg/h Temperature : 150deg.C Pressure : | Okgjem’G Density :1.039kg/m* Viscosity :0.014eP Diff, Press :1500mmH130 Inside Pipe Diameter : 200A SGP, 204. 7mm Flange Type : JIS-10K-200A-RF Direction for use Calculation Chart 1) Checking of Reynolds Number (Rp) © _p=0.014eP, D=204.7mm ‘Two points are on the same line and drawing up to auxiliary line. (Plotting Point 29.5) ® Plotting Point 29.5 and G~2500kg/h. ‘Two points are on the same line and reading Rp =3,9*10°, Calculation by hand for checking, Rp~354*2500/204.790.014-3.09"10° Aue Line # » noe wma, Bom | 2) Checking of square port ratio “my”. (Fig. 1) © _D=204.7mm and G=2500kg/4 ‘Two points are on the same line and plotting up to auxiliary line (a). (Plotting Point: 4250, Left Scale) ® Plotted Point 4250 and y1=1.039kg/m? ‘Two points are on the same line and plotting up to auxiliary line (b) (Plotting Point: 0.0018, Right Scale) © Plotting Point: 0.0018 and P;~ P:=1500mmH,0 Two points are on the same line and reading of "mn", m=0.21 Aaclineiag aay hon bine) “BO Technical Orifice Data Information (Orifice Calculation Data for Various Case) Orifice Calculation Chart BoP amg « kefatabs| ke/emtza 4 10000 Technical Orifice Data Information (Orifice Calculation Data for Various Case) Reynolds Number Calculation Chart 8 8 2 . 3 We ie’ 2 : ie 7 2388 a 2° uy isu df usta oe a + os el Technical Orifice Data Information (Orifice Calculation Data for Various Case) Selection Chart of Edge Orifice Type or Quadrant Orifice More than m=0.519 (80.7204), ma=0.365, ‘Can not manufacture the quadrant otifice. ei a Os oa as #974 20m= 5 Fig.-4 Direction for use, Both calculation data are based on the scale flow range, which are Reynolds Number (Ry) and Edge orifice "™m”. [Above data to be used decision edge orifice or quadrant orifice as bellows manner. Upper than (@) Always select Edge Orifice suggest selecting Badge Orifice Berween ) and ©) —- Suggest selecting Quadrant Orifice Lower than (@)——-—--- Always select Quadrant Orifice Technical Orifice Data Information (Orifice Calculation Data for Various Case) $9.2 ASME P.T.CI4;5 APPLICATION PART # OF FLUID METERS STX EDITION-1971 a me Technical Orifice Data Information (Orifice Calculation Data for Various Case) 9.11 ASME POWER TEST CODES PTC 195;4~1959 FLOW MEASUREMENT 9.11.1 FigS Overall Pressure Lows Through Several Primary Elements al diferantiah Preeaure Lows In % of Diomerer Rolo 8 Technical Orifice Data Information (Orifice Calculation Data for Various Case) Orifice Calculation Chart Ex. 1 Somple plot 7 =r Pe Avetb? Avett. Fig-1 1M Line (3) o2tthunatfont Disk Range VO Tr. AISdetH UMTS Hazlet B ratio VOI Orifice “akttiy sais Fi 4000 mmH20 a2 If B= 0.61 uAGuTiazi@ant 2000 mmH20 erie B HAAOONOIN Limit fio a1 delays als 7.1 LA (Limit fla tu Line | ia 2 fl plot au Edge Orifice Scale)

Potrebbero piacerti anche