Sei sulla pagina 1di 1

TR NO.

PAGE:
REVISION:
REV. DATE:

TECHNICAL
REFERENCE
TITLE:

TR-100
8
F
30 Dec 2013

Allowable Nozzle Loading (Forces & Moments)

Series 724, 4724

(4724 PUMP SHOWN IN DRAWING)


LOADING COORDINATE SYSTEM:
X: PARALLEL TO PUMP SHAFT
Y: VERTICAL, PERPENDICULAR TO PUMP SHAFT
Z: HORIZONTAL, PERPENDICULAR TO PUMP SHAFT

P: FORCES (LBF / N)
M: MOMENTS (FT-LBF / N-m)

PORT A
PUMP SIZE
(FLANGE SIZE)
8,9

F (0.5) &FH
8,9

(0.75)

(1)
9

H&HL (1.5)
9

K,KK&L (2)
LQ (2.5) &LL (3)

PORT B

Px

Py

Pz

Mx

My

Mz

Px

Py

Pz

Mx

My

Mz

100
445
85
375
360
1600
420
1870
450
1950

105
465
95
420
360
1600
420
1870
450
1950

120
535
120
535
360
1600
420
1870
450
1950

25
35
25
35
230
300
440
600
485
650

10
14
10
14
90
120
150
200
195
260

25
35
25
35
25
35
50
70
220
300

100
445
85
375
360
1600
420
1870
450
1950

105
465
95
420
360
1600
420
1870
450
1950

120
535
120
535
360
1600
420
1870
450
1950

25
35
25
35
230
300
440
600
485
650

10
14
10
14
25
35
50
70
195
260

25
35
25
35
90
120
150
200
220
300

Pump has opposite ports. Port B is directly opposite Port A.


Pumps have tapped ports

VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA 50613 U.S.A.

Potrebbero piacerti anche