Sei sulla pagina 1di 2

Turbine net heat rate

Mass flow to the HP turbine


Reheater spray(left side)
Reheater spray(Right side)
Reheater spray- Total
Hot reheat steam flow

532.914 kg/s
0 kg/s
0 kg/s
0 kg/s
447.092 kg/s

Feed water enthalpy at economiser inlet


Enthalpy of main steam at HP turbine inlet
HP turbine exhaust enthalpy
RH spray water enthalpy
Enthalpy of hot reheat at IV valve inlet

1278.9 kj/kg
3395.4 kj/kg
3018.4 kj/kg
801.7 kj/kg
3651.1 kj/kg

Gross generated MW
Aux. power consumption
Net generated MW

660 MW
0.55 MW
659.45 MW

Turbine net heat rate

594.261 kj/kwh

148.0317 t/h
0 t/h
0 t/h
0 t/h
124.1922 t/h

Potrebbero piacerti anche