LOAD CALIBRATION PROCEDURE FOR WEIGH FEEDER

e distance

Test weight GP Calibration point


Test weight GP Lever Ratio point

Kg/m: Load on the load cell


GM: Load on the load cell
FM: Load on the load cell

Example for Weigh feeder

Capacity
: 100 TPH
Speed
: 0.182 m/s
Load cell
: 50 Kg
EXC
: 11.81 Volt
Tare mV
: 2.4 mV
Span mV
: 11.4 mV (keeping the test weight on the knife edge for calibration)
Test weight
: 16.4 Kg.
mV for Lever ratio : 5.38 mV (Keeping the test weight on the center of the center measuring
idler )
Step by step of calibration calculation:
TPH

: Kg/m x m/s x 3.6

Kg /m

: TPH / (M/s.x3.6)

: 152.672 Kg (100 / (0.182*3.6)

GM (Kg @ Measuring Zone 0.35m) : Kg/m x 0.35 : 53.435 Kg


FM (Load on Load cell) : GM / Lever ratio

: 20.552 Kg

(152.672 x 0.35)
(53.435 / 2.6). 100%

Lever Ratio:
As per the design the Lever ratio is 2,5, but due to the mechanical clearness the Lever ratio is
possible to vary, so calculate the exact lever ratio and proceed to FM.
It means how much Kg applied on one side and how much Kg is getting on the another side,
This ratio is called as lever ratio.
In Weigh feeder GM is applied weight & getting weight is FM. By the calculation of exact
FM (Based on the cross calculation of load cell mV), the exact Lever ratio is calculated.
Lever ratio point:
Remove the skirt board and keep the test weight in line with the Center of the center
measuring idler.

50 Kg =

23.62 mV (11.81 x2)

Net mV : (Lever ratio mV Tare mV)


: (5.38 mV 2.4 mV)
: 2,98 mV
As per mV cross calculation getting Kg : 6.308 Kg

. (( 50/23.62) x 2.98)

Applied weight is 16.4 Kg but getting 6.308 Kg.


Therefore Lever Ratio : 16.4 / 6.308
: 2.6 (use this value for FM calculation)

Calibration Percentage:
It is derived based on the comparison of FM with Test weight simulation. It is obtained by
two methods,
Method 1:
The calibration percentage is calculated based on the e distance w.r.t to Test weight.
Formula:
edistance for 100 % Calibration percentage: (FM x 200) / Test weight.
Note:
1. In this method, the error is possible in the calibration due to following reason:
1.1 Mechanical clearness error.
1.2 Operation error while setting e distance.
2. The accuracy of the weigh feeder is got disturbed due to this above error.
3. To over come this error, cross check the calibration percentage w.r.t load cell mV.
Method 2:
It is derived based on the comparison of net weight on the load cell (by cross calculation
weight w.r.t to mV) with FM
Note:
1. In this method the all the errors are possible to over come.

Method: 1
e distance

: (FM x 200) / Test weight.


: ( 20.552 x 200) / 16.4
: 250.6 mm

Keep the16,4 Kg test weight on the knife edge at 250.6mm e distance of for 100 %
calibration.
Note:
1. After keep the test weight at e distance, note down the span mv, Once again ensure
the calibration percentage by the method-2

Method: 2
Note down the span mV, after keeping the test weight with the same e distance.
The span mV: 10.8 mV.
EXC
Load cell Sensitivity
50 Kg =

: 11.81 V
: (2mV/V)

23.62 mV (11.81 x2)

As per test weight mV : Span mV Tare mV


(11.4 2.4) 9 mV = 19.051 kg ((50 / 23.62) x 8.4) .( By using test weight simulation)

100 % weight is

: 20.552 K

.. (Fm)

19.051 Kg is
Calibration counts

: 92.69 % Calibration (Before cross check test)


: 1853 d .( 2000 d = 100 % )

Therefore as per the cross check the calibration percentage is not a 100% it is 92.69% .
The error in the calculation is around 8%.
There is no needed for drop test if the calibration has been done by method: 2.
Note:
1. The site readings entered as a RED colour.
2. The calculated values are marked as a under line.
3. Enter your site readings in RED colour area and calculate the value and proceed
the calibration.

Speed Calibration
1. Measure the total belt length, operate the weigh feeder inching by inch and put a
measurement mark on the belt and find out the total belt length.
2. Run the weigh feeder at calibration speed (33Hz / 1000RPM).
3. Measure the time for 5 revolution, & average the revolution time, at the same time
note down the Ta indication in the TUC display.
4. Calculate the M/s.
5. Enter the displayed Ta & M/s in measuring parameter.
Example:
Belt length
Time for 5 Rev
Average time
Speed

: 7 Meter
: 146 Sec
: 146 / 5 = 29.2 Sec
: Meter /sec = 7/29,2 = 0.24 m/s. (At the time Ta is 557 Hz).

Enter this Ta 557 in nominal tacho frequency & 0.24 in Belt speed in the measuring
parameter.
Cross check:
1. Run the weigh feeder at 20Hz, calculate the Practical m/s and compare with the TUC
displayed M/s.
2. The same way ensure 4 to 5 point of drive frequency and conformed the indicated
M/s. is in line with the displayed M/s.
Note:
Once the cross checking is perfect, TF correction is not advisable for error correction.