Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
S TA N D A R D 2 5 G G U Y E D T O W E R
ROHN
25G
The first. The original.
includes
REV. F &
REV. G
25G
GENERAL USE
The 25G is available in the standard 10 section
length and a 7 length which is UPS shippable.
The 25G uses double bolted joints, proven to be
the best method of joining tower sections for
sturdiness and dependability. As a guyed
structure, the 25G standard designs rise to a
height of 190.
FEATURES
Completely hot-dip galvanized after fabrication
Built on an 11 1/4 equilateral triangle design
High strength tubular legs joined by Zig-Zag
cross members
Each 7 or 10 section contains all required nuts
and bolts shipped with section
Continuous solid round steel bracing
CAUTION
Mixing copies of ROHN towers with ROHN towers is dangerous and voids all
engineering and warranty data supplied by ROHN. Materials used by others are
not the same quality and have not been tested or engineered by ROHN. Mixing
ROHN tower sections with non-ROHN products may cause tower failure or injury.
24
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
S TA N D A R D 2 5 G G U Y E D T O W E R
SECTIONS
6 1/2
9 3/4
QUICK REFERENCE
PARTS & ACCESSORIES
GROUNDING INFORMATION
FOUNDATION INFORMATION
11 1/4
1 6
Optional Waveguide
Brackets (KY2041A)
PAGES 37-40
PAGE 41
PAGES 41-44
2.25 O.D.
2.08 I.D.
(14 GA.)
1 3
9 9
1 1/4 O.D.
(16 GA.)
1 1/4 O.D.
(16 GA.)
~
~
5/16 O.D.
Solid Bracing
5/16 O.D.
Solid Bracing
STANDARD SECTION
25G - 10 Section
OPTIONAL 7 SECTION
25G7 - 7 Section
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
25
BUYERS GUIDE
S TA N D A R D D E S I G N S - 2 5 G
9 0 M P H R E V. G [ 3 - S E C O N D G U S T ]
7 0 M P H R E V. F [ FA S T E S T M I L E ]
Design Criteria
22.6
35
22.0
47
3/16 EHS
(399#)
P/N 25G90R040
32
P/N 25G90R040
Tower Model
Windspeed (Rev. G)
This document is to serve as a guide for sizing and purchasing the 25G tower. Tower and foundation installations should
be performed by qualified and experienced personnel using assembly drawings provided with each tower.
DESIGN NOTES:
1. Tower designs are in accordance with ANSI/TIA-222-F and ANSI/TIA-222-G, Class I Structures, Topographic Category 1.
2. Design assumes towers are installed on level ground. Lower EPA values will apply for roof mounted towers or for sites
located on unusual terrain.
3. Designs assume two 1/2 diameter lines on each tower face.
4. Anchor radius is from tower base to intersection of anchor rod with ground.
5. Guy chord lengths shown are based on level ground. Initial tensions for guys are shown in ( ) in pounds at 60 Fahrenheit.
6. Antenna and mounts are assumed symmetrically placed at the tower top.
PARTS LIST NOTES:
1. Items listed are required for complete guyed towers.
2. Base and anchor foundations listed refer to standard foundation designations.
3. Guys provided with each standard tower are based on level ground conditions with an additional 6% length.
4. Rev G anchor grounding (AGK1GGX) and base grounding (BGK3GGX) are included with the tower material.
5. Assembly drawings and a safety package (P/N: ACWS) are included with each tower.
6. Parts lists are subject to change based on availability or revised design criteria.
FOR FOUNDATION INFORMATION, PLEASE SEE PAGES 41-44.
FOR GENERAL INSTALLATION INFORMATION, PLEASE SEE PAGES 147-153.
26
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
35
40 TOWER
22.6 OR 16.6
22.0
47
3/16 EHS
(399#)
32
P/N: 25G90R040
45
50 TOWER
21.4 OR 15.8
21.0
60
3/16 EHS
(399#)
23
46
40
P/N: 25G90R050
55
60 TOWER
20.3 OR 15.2
20.2
73
3/16 EHS
(399#)
28
56
48
P/N: 25G90R060
65
70 TOWER
19.4 OR 14.7
19.4
86
3/16 EHS
(399#)
32
64
56
P/N: 25G90R070
75
80 TOWER
18.6 OR 14.3
18.8
99
3/16 EHS
(399#)
50
81
25
69
64
P/N: 25G90R080
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G
25AG2
3/16EHS
BG2142
175
BPC25G GA25GD
1
25G
25AG2
BPC25G
GA25GD
3/16EHS
BG2142
350
12
12
25G
25AG2
BPC25G
3/16EHS
BG2142
425
12
FDNS
BASE ANCHOR
CB1G AB2
FDNS
GA25GD BASE ANCHOR
2
25G
25AG2
BPC25G
3/16EHS
BG2142
500
12
CB1G AB2
FDNS
GA25GD BASE ANCHOR
2
25G
25AG2
BPC25G
3/16EHS
BG2142
800
18
CB1G AB2
FDNS
GA25GD BASE ANCHOR
3
CB1G AB2
80 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G90R 080
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
70 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G90R 070
3/4x12PP
60 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G90R 060
3/4x12PP
50 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G90R 050
3/4x12PP
40 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G90R 040
3/4x12PP
CB1G AB2
FDNS
BASE ANCHOR
27
S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
90 TOWER
18.0 OR 13.9
85
18.4
111
3/16 EHS
(399#)
57
92
28
77
72
P/N: 25G90R090
100 TOWER
17.5 OR 13.6
95
18.0
124
3/16 EHS
(399#)
63
102
31
86
80
P/N: 25G90R100
110 TOWER
17.0 OR 13.4
105
17.6
137
3/16 EHS
(399#)
70
112
35
95
88
P/N: 25G90R110
120 TOWER
16.6 OR 13.1
115
17.2
150
85
128
55
3/16 EHS
(399#)
111
100
28
96
P/N: 25G90R120
125
93
130 TOWER
16.2 OR 12.9
17.0
163
140
62
31
3/16 EHS
(399#)
121
108
104
P/N: 25G90R130
28
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G
25AG2
BPC25G
3/16EHS
BG2142
900
18
GA25GD BASEFDNS
ANCHOR
3
25G
25AG2
BPC25G
3/16EHS
BG2142
1000
18
3/4x12PP
1
CB1G AB2
25G
25AG2
BPC25G
10
3/16EHS
BG2142
1100
18
3
3/4x12PP
1
CB1G AB2
25G
25AG2
BPC25G
11
3/16EHS
BG2142
1575
24
FDNS
GA25GD BASE ANCHOR
4
12
25G
25AG2
BPC25G
12
3/16EHS
BG2142
1700
24
CB1G AB2
FDNS
GA25GD BASE ANCHOR
4
12
3/4x12PP
CB1G AB2
3/4x12PP
FDNS
GA25GD BASE ANCHOR
90 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G90R 090
FDNS
GA25GD BASE ANCHOR
CB1G AB2
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
140 TOWER
15.9 OR 12.7
135
16.6
175
99
149
66
3/16 EHS
(399#)
130
117
33
112
P/N: 25G90R140
150 TOWER
15.5 OR 12.5
145
16.4
116
188
87
167
148
58
3/16 EHS
(399#)
133
123
29
120
P/N: 25G90R150
155
124
93
62
31
160 TOWER
15.3 OR 12.3
16.2
201
178
158
3/16 EHS
(399#)
142
132
128
P/N: 25G90R160
165
170 TOWER
15.0 OR 12.2
16.0
132
214
99
190
168
66
33
3/16 EHS
(399#)
151
140
136
P/N: 25G90R170
175
180 TOWER
14.8 OR 12.0
15.8
139
227
105
200
178
69
35
3/16 EHS
(399#)
160
148
144
P/N: 25G90R180
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
25G
25AG2
BPC25G
13
3/16EHS
BG2142
1825
24
FDNS
GA25GD BASE ANCHOR
4
12
25G
25AG2
BPC25G
14
3/16EHS
BG2142
2425
30
3/4x12PP
1
CB1G AB2
25G
25AG2
BPC25G
15
3/16EHS
BG2142
2600
30
15
3
3/4x12PP
1
CB1G AB2
25G
25AG2
BPC25G
16
3/16EHS
BG2142
2750
30
15
FDNS
GA25GD BASE ANCHOR
5
15
25G
25AG2
BPC25G
17
3/16EHS
BG2142
2925
30
CB1G AB2
FDNS
GA25GD BASE ANCHOR
5
15
CB1G AB2
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
3/4x12PP
3/4x12PP
FDNS
GA25GD BASE ANCHOR
FDNS
GA25GD BASE ANCHOR
CB1G AB2
29
S TA N D A R D D E S I G N - 2 5 G
9 0 M P H R E V. G , 7 0 M P H R E V. F
185
148
111
190 TOWER
14.5 OR 11.9
15.6
239
212
3/16 EHS
(399#)
188
74
169
37
156
152
P/N: 25G90R190
30
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
18
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
3075
30
ANCHORS &
GROUNDING
INCLUDED
FDNS
GA25GD BASE ANCHOR
5
15
CB1G AB2
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
35
40 TOWER
13.4 OR 9.7
13.4
47
3/16 EHS
(399#)
32
P/N: 25G110R040
50 TOWER
12.6 OR 9.1
45
12.6
60
3/16 EHS
(399#)
22
46
40
P/N: 25G110R050
60 TOWER
11.9 OR 8.7
55
12.2
73
3/16 EHS
(399#)
28
56
48
P/N: 25G110R060
65
70 TOWER
11.3 OR 8.6
11.8
86
3/16 EHS
(399#)
32
64
56
P/N: 25G110R070
75
80 TOWER
10.9 OR 8.3
11.4
99
3/16 EHS
(399#)
50
81
25
69
64
P/N: 25G110R080
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
175
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
350
12
12
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
425
12
12
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
500
12
CB1G AB2
FDNS
GA25GD BASE ANCHOR
2
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16 EHS
BG2142
800
18
CB1G AB2
FDNS
GA25GD BASE ANCHOR
3
CB1G AB2
80 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G110R 080
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
70 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G110R 070
3/4x12PP
60 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G110R 060
3/4x12PP
50 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G110R 050
3/4x12PP
3/4x12PP
FDNS
GA25GD BASE ANCHOR
40 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l uded when order i ng
Par t No: 25G110R 040
FDNS
GA25GD BASE ANCHOR
CB1G AB2
2
ANCHORS &
GROUNDING
INCLUDED
CB1G AB2
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
FDNS
GA25GD BASE ANCHOR
31
S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
90 TOWER
10.5 OR 8.1
85
11.2
111
3/16 EHS
(399#)
56
91
28
77
72
P/N: 25G110R090
100 TOWER
10.2 OR 7.9
95
10.8
124
3/16 EHS
(399#)
63
102
32
86
80
P/N: 25G110R100
110 TOWER
9.9
OR 7.8
105
10.6
137
3/16 EHS
(399#)
70
112
35
95
88
P/N: 25G110R110
115
120 TOWER
9.7 OR 7.6
10.4
150
86
129
57
28
3/16 EHS
(399#)
112
100
96
P/N: 25G110R120
125
93
130 TOWER
9.3 OR 7.5
10.2
163
140
62
31
3/16 EHS
(399#)
121
109
104
P/N: 25G110R130
32
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
900
18
ANCHORS &
GROUNDING
INCLUDED
18
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
1000
18
18
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
10
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
1100
18
18
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
11
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
5/16THH
1575
24
24
25G
25AG2
BPC25G
12
3/16EHS
BG2142
1700
24
CB1G AB2
3
3/4x12PP
1
CB1G AB2
3/4x12PP
1
CB1G AB2
1/2TBE&J TBSAFETY
12
3/4x12PP
1
GA25GD BASEFDNS
ANCHOR
4
CB1G AB2
FDNS
GA25GD BASE ANCHOR
12
3/4x12PP
FDNS
GA25GD BASE ANCHOR
90 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G110R 090
FDNS
GA25GD BASE ANCHOR
ANCHORS &
GROUNDING
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
TOWER PARTS
INCLUDED
CB1G AB2
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
FDNS
GA25GD BASE ANCHOR
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
140 TOWER
9.2 OR 7.4
135
10.0
175
101
151
67
3/16 EHS
(399#)
131
33
117
112
P/N: 25G110R140
150 TOWER
9.0 OR 7.3
145
9.9
116
188
167
87
148
58
3/16 EHS
(399#)
133
29
123
120
P/N: 25G110R150
160 TOWER
8.8 OR 7.2
155
9.8
201
124
178
93
158
62
3/16 EHS
(399#)
142
31
132
128
P/N: 25G110R160
170 TOWER
8.7 OR 7.1
165
9.7
138
214
110
194
83
175
159
55
3/16 EHS
(399#)
74
28
57
50
136
P/N: 25G110R170
176
145
180 TOWER
8.6 OR 7.0
9.6
227
116
204
87
185
168
58
29
3/16 EHS
(399#)
77
58
50
144
P/N: 25G110R180
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
13
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
1825
24
ANCHORS &
GROUNDING
INCLUDED
24
CB1G AB2
12
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
14
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
2425
30
30
FDNS
GA25GD BASE ANCHOR
5
CB1G AB2
15
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
15
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
2600
30
FDNS
GA25GD BASE ANCHOR
5
CB1G AB2
15
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GA25GD
BASE
16
CB2G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
5/16THH
2800
36
36
TOWER PARTS
INCLUDED
GUYS &
CONNECTIONS
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
INNER
OUTER
ANCHOR ANCHOR
18
25G
25AG2
BPC25G
GA25GD
BASE
17
CB2G
3/16EHS
BG2142
5/16THH
2925
36
36
INNER
OUTER
ANCHOR ANCHOR
AB2
AB2
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
Al l par ts shown i n
tabl e are i nc l uded
when ord er i ng
Par t No: 25G110R 170
1/2TBE&J TBSAFETY
18
3/4x12PP
AB2
AB2
1/2TBE&J TBSAFETY
3/4x12PP
ANCHORS &
GROUNDING
INCLUDED
3/4x12PP
3/4x12PP
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
FDNS
GA25GD BASE ANCHOR
33
S TA N D A R D D E S I G N - 2 5 G
1 1 0 M P H R E V. G , 9 0 M P H R E V. F
186
155
124
190 TOWER
8.5 OR 6.9
9.5
240
217
93
196
178
62
80
31
59
3/16 EHS
(399#)
50
152
P/N: 25G110R190
34
INNER
OUTER
ANCHOR ANCHOR
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GA25GD
BASE
18
CB2G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
5/16THH
1/2TBE&J
TBSAFETY
3100
36
36
18
ANCHORS &
GROUNDING
INCLUDED
AB2
3/4x12PP
AB2
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
S TA N D A R D D E S I G N - 2 5 G
1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F
40 TOWER
10.8 OR 7.9
38
11.2
50
3/16 EHS
(399#)
32
P/N: 25G130R040
48
50 TOWER
10.1 OR 7.5
10.0
62
3/16 EHS
(399#)
22
46
40
P/N: 25G130R050
58
60 TOWER
9.7 OR 7.2
9.8
75
3/16 EHS
(399#)
28
56
48
P/N: 25G130R060
68
70 TOWER
9.2 OR 7.0
9.6
88
3/16 EHS
(399#)
32
64
56
P/N: 25G130R070
78
80 TOWER
8.9 OR 6.8
9.4
101
3/16 EHS
(399#)
50
81
25
69
64
P/N: 25G130R080
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
175
ANCHORS &
GROUNDING
INCLUDED
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
350
12
12
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
425
12
CB1G AB2
12
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
500
12
CB1G AB2
FDNS
GA25GD BASE ANCHOR
2
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
800
18
CB1G AB2
FDNS
GA25GD BASE ANCHOR
3
CB1G AB2
80 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l uded when order i ng
Par t No: 25G130R 080
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
70 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l uded when order i ng
Par t No: 25G130R 070
3/4x12PP
60 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l uded when order i ng
Par t No: 25G130R 060
3/4x12PP
50 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l uded when order i ng
Par t No: 25G130R 050
3/4x12PP
3/4x12PP
FDNS
GA25GD BASE ANCHOR
40 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l uded when order i ng
Par t No: 25G130R 040
FDNS
GA25GD BASE ANCHOR
ANCHORS &
GROUNDING
INCLUDED
CB1G AB2
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
ANCHORS &
GROUNDING
INCLUDED
FDNS
GA25GD BASE ANCHOR
35
S TA N D A R D D E S I G N - 2 5 G
1 3 0 M P H R E V. G , 1 1 0 M P H R E V. F
90 TOWER
8.6 OR 6.7
88
9.2
114
3/16 EHS
(399#)
56
91
28
77
72
P/N: 25G130R090
98
100 TOWER
8.3 OR 6.5
9.0
127
3/16 EHS
(399#)
63
102
32
86
80
P/N: 25G130R100
36
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
900
18
ANCHORS &
GROUNDING
INCLUDED
18
TOWER PARTS
INCLUDED
25G
25AG2
BPC25G
GUYS &
CONNECTIONS
INCLUDED
3/16EHS
BG2142
1000
18
3
3/4x12PP
1
CB1G AB2
90 ROHN 25G
Al l par ts shown i n tabl e
a re i nc l ud ed when ord er i ng
Par t No: 25G130R 090
FDNS
GA25GD BASE ANCHOR
CB1G AB2
ANCHORS &
GROUNDING
INCLUDED
FDNS
GA25GD BASE ANCHOR
3/4x12PP
1
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
PA R T S & A CC E S S O R I E S
8 1/4
1 - 0
2.00 O.D.
1.87 I.D.
1 - 6
1.66 O.D.
1.38 I.D.
1.25 N.P.T.
Set Screw
9 - 9
TOP SECTION
25AG
COMES WITH TOP BUSHING INSTALLED,
1.31 I.D.
TOP SECTION
25AG2
TOP SECTION
25AG1
1 - 1/4
1 - 5 1/4
8 - 3 1/2
1 - 4 3/4
9 - 3 1/2
Set Screw
1-3 3/4
1-3 3/4
1 - 3 3/4
2.25 O.D.
2.08 I.D.
1 - 0
1 - 3
9 - 3 1/4
1 - 3
9 - 0
1 - 4
8 - 3/16
2.25 O.D.
2.08 I.D.
TOP SECTION
25AG3
Set Screw
2.75 O.D.
2.58 I.D.
1-3 3/4
BEARING PLATE
BPL25G
TOP SECTION
25AG4
TOP PLATE
APL25G
TOP SECTION
25AG5
TOP MOUNT
25TDMKD - NO MAST
25TDM2S3KD - 2 3/8 O.D. MAST
25TDM25S3KD - 2 7/8 O.D. MAST
25TDM3S3KD - 3 1/2 O.D. MAST
25TDM35S3KD - 4 O.D. MAST
MOUNTING TUBE PROVIDED IS 7 LONG.
1- 4
BEARING/ACCESSORY SHELF
BAS25G
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
LIGHTNING ROD
LRCL
37
PA R T S & A CC E S S O R I E S
PIER PIN
3/4X12PP
FOR USE WITH BPC25G
EMBEDDED IN CONCRETE.
PIER PIN MUST BE ORDERED
SEPARATELY, UNLESS BEING
PURCHASED AS PART OF
A COMPLETE TOWER KIT.
5/8 x 12
1/2 x 12
BASE BOLTS
1/2X12BB
FOR USE WITH BPH 25G
(6) REQUIRED, ORDERED SEPARATELY.
TAPERED BASE
25TG*
CAN BE USED WITH A4197L
BASE INSULATOR OR WITH 3/4x12PP,
ORDERED SEPARATELY.
34 SHORT BASE
SB25G
5 SHORT BASE
SB25G5
WALL MOUNT
25GWM
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
38
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
PA R T S & A CC E S S O R I E S
1
7/8 - 1 1/8 O.D.
Mounting Pipe
1
FACE MOUNT
DM25G2 - 2 3/8 O.D. 5 LONG
Adjustable
2.5 - 3.0
TORQUE BAR
TB25D
GUY BRACKET
GA25GD
MOUNTS TO TOWER AT ANY
HORIZONTAL BRACE.
ACCESSORY SHELF
AS25G
FOR MOUNTING MANY POPULAR
ROTORS. FIELD DRILLING MAY BE
NECESSARY FOR SOME ROTORS.
* TOWERS MOUNTED ON THESE BASES MUST BE BRACKETED OR GUYED AT ALL TIMES. TEMPORARY STEEL GUYING MAY ALSO BE NECESSARY DURING INSTALLATION AND DISMANTLING.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
39
PA R T S & A CC E S S O R I E S
Tower
Leg
RP25G
THRUST BEARING
TB3 - SUPPORTS UP TO 2 O.D. MAST.
TB4 - SUPPORTS UP TO 3 O.D. MAST.
TOWER BUSHING
TB50 - 1-1/4 I.D. X 2 O.D.
TB75 - 1-1/2 I.D. X 2 O.D.
Tower
Leg
RP25G CM
ROTOR POST
1.25 O.D.
1.08 I.D.
90 JOINTS
2590FF - BOTH ENDS OPEN
JOINTS ARE NOT DRILLED WHERE THEY
SLIP FIT TO 25G SECTIONS. CAN BE
FIELD DRILLED OR CUSTOM CONNECTED
TO MEET PARTICULAR NEEDS.
90 JOINTS
2590FM - ONE END SWAGED,
ONE OPEN
JOINTS ARE NOT DRILLED WHERE THEY
SLIP FIT TO 25G SECTIONS. CAN BE
FIELD DRILLED OR CUSTOM CONNECTED
TO MEET PARTICULAR NEEDS.
ANTI-CLIMB PANELS
25ACL3
THREE ANTI-CLIMB PANELS BOLT
TO STANDARD TOWER SECTION.
90 JOINTS
2590MM - BOTH ENDS SWAGED
JOINTS ARE NOT DRILLED WHERE THEY
SLIP FIT TO 25G SECTIONS. CAN BE
FIELD DRILLED OR CUSTOM CONNECTED
TO MEET PARTICULAR NEEDS.
SAFETY RING
SR245
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
CLIMBING HARNESS
TTFBH-4D
JOURNEYMAN HARNESS
TTFBH-C/P
PROFESSIONAL HARNESS
ERECTION FIXTURE
EF2545 - 2 1/2 SHEAVE WITH
3/8 I.D. GROOVE.
WORK PLATFORM
WP25G
SNAPS INTO PLACE AT ANY LEVEL.
NO BOLTS REQUIRED.
40
PART
NUMBER
TT05025
TT10025
TT15025
TT20025
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
A N C H O R I N F O R M AT I O N
81
12
3/8
CL of hole to edge
of plate = 1
3/4
4 x 4 x 3/8 angle
2
11/16
GAC3455TOP
120
12
1/2
CL of hole to edge
of plate = 1 1/4
1 1/4
5 x 5 x 3/8 angle
2 1/2
13/16
GAC5655TOP
REV G
BASE GROUNDING
BGK3GGX
REV G
ANCHOR GROUNDING
AGK1GGX
6 Min.
Ground Rod,
3 provided (to be installed
o
at 120 separation at 20 spacing.
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
41
S TA N D A R D A N C H O R B LO C K S
Anchor rod
Ground Line
A
B
42
Block
AB2
4 - 0 1 - 6 4 - 0 6 - 0
AB3
6 - 0 1 - 6 3 - 0 6 - 0
AB4
6 - 0 1 - 6 4 - 0 9 - 0
AB5
8 - 0 2 - 0 3 - 0 10 - 0
AB6
8 - 0 2 - 0 4 - 0 10 - 0
Horizontal Bars
(Qty. & Size)
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #6 Bars, Top Layer
(4) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(5) #6 Bars, Top Layer
(5) #6 Bars, Bottom Layer
(0) Additional Bar, Each Side
(4) #7 Bars, Top Layer
(4) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
(5) #7 Bars, Top Layer
(5) #7 Bars, Bottom Layer
(1) Additional Bar, Each Side
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
A N C H O R R O D I N S TA L L AT I O N A N G L E S
120
Rod Angle
(in degrees)
Tower Plan
25G | 90MPH
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Rod
Rod
Number
Angle
GAC3455TOP 48
GAC3455TOP 42
GAC3455TOP 42
GAC3455TOP 42
GAC3455TOP 39
GAC3455TOP 39
GAC3455TOP 39
GAC3455TOP 39
GAC3455TOP 38
GAC3455TOP 38
GAC3455TOP 38
GAC3455TOP 37
GAC3455TOP 37
GAC3455TOP 37
GAC3455TOP 37
GAC3455TOP 37
Ground Line
25G | 130MPH
25G | 110MPH
Tower
Height
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
Tower
Height
40
50
60
70
80
90
100
Rod
Rod
Number
Angle
GAC3455TOP 50
GAC3455TOP 41
GAC3455TOP 41
GAC3455TOP 40
GAC3455TOP 38
GAC3455TOP 38
GAC3455TOP 38
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC
43
S TA N D A R D B A S E P I E R S
Pier Pin
4 Projection
Grade
ELEVATION VIEW
Alternate
Square
Pier
CL
CL
PLAN VIEW
Base
CB1G* 2 - 6 4 - 0
1.0
(8) #7
CB2G
1.2
(10) #7
3 - 0 4 - 0
44
Phone (309) 566-3000 Fax (309) 566-3079 www.rohnnet.com The Industry Standard
2011 ROHN PRODUCTS LLC