Client: extended Polymer Systems Pvt. Ltd.

Stair Weight calculation:

Sr. No.
1
2
3
4
5
6
7
8
9

9
10
11
12
13
14
10

Particular
No. of stairs
No of post
Post Height
ISMC 150, Length
Angle Plate,Length
Chequred Plate
Hand Rail Length
No. of Angle plate
No. of Plates

18-11-2008

mm
=
=
=
=
=
=
=
=
=

Weight of ISMC 150


=
Weight of chequred plates
=
Weight of Angle plate
=
Weight of Post
=
Weight of Hand Rail
=
Plates
=
Landing Area
=
Total weight of stair assembly

89
45
1000
57000
750
88
182000
178
176

957.6
1306.14
758.28
142.875
577.85
835.9296
237.48
4816.1546
4.8161546

32 NB Tube
size 50*50*6
750*250
32 NB Tube
300*200
1000*750*10

kg
kg
kg
kg
kg
kg
kg
T

10 thickness

Client: extended Polymer Systems Pvt. Ltd.


Anchor Chair Weight calculation:

1
2
3
4
5
6
7
8
9

Diameter of the Tank


No.of anchor Chairs
Diameter of the Anchor Circle
Anchor Bolt Material

=
=

18-11-2008

14.5 m
24