DESIGN BASIS STATEMENT (Inc. sources of info/data, assumption made, standards, etc.)

DATE

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C102)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


b

A. Parameters
b =

2500 mm

d =

5000 mm

f'c =

28 N/mm

Spacing =

fy = 460 N/mm

N* =

930 kN

M* =
Nu =

222000 kN

Mu =

110000 kN-m

Concrete Cover =

40 mm

Main Bar Diameter =

25 mm

Link Diameter =
=

16 mm
0.6

150 mm
0 kN-m
X

No. of Bars (X-dir.) =

37

No. of Legs (X-dir.) =

No. of Bars (Y-dir.) =

88

No. of Legs (Y-dir.) =

B. Calculations
Link Area =
bc =
dc =
Ac =

Clause 10.7.3.1.b

201 mm

Clear Spacing (x) =

41 mm

2404 mm
4904 mm

Clear Spacing (y) =


Min. Spacing =

31 mm
300 mm

Bars bundled =
Smax =

300 mm

11789216 mm

No

Check if column need not be designed using Clause 10.7.3.3:


a.)
N* 0.3 fc' Ag
0.3 fc' Ag =
=

0.6 x 0.3 x 28 x 12500000


63000 kN
> N* Detail using Clause 10.7.4

0.25 > (M*/0.6Mu) + (N*/0.6Nu)

b.)

(M*/0.6Mu) + (N*/0.6Nu) = (0/0.6*110000) + (930/0.6*222000)


=

0.0

<0.25 Detail using Clause 10.7.4

Since at least one criteria passed, fitments can be detailed using Clause 10.7.4 only.
Clause 10.7.3.1 c

Min. effective confining pressure (frmin) = 0.015 fc' = 0.42 N/mm

Clause 10.7.3.3

Along X- Direction
fr = [(No. of Legs x Alink x fyL)/(s x bc)]

Along Y- Direction
fr = [(No. of Legs x Alink x fyL)/(s x ds)]

= [(4 x 201 x 460)/(150 x 2404)]

= [(4 x 201 x 460)/(150 x 4904)]

= 1.03 N/mm

= 0.50 N/mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 4
w = 41 mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 4
w = 31 mm

ke = 0.954

ke = 0.954

fr, eff =

fr, eff =

ke * f r
0.98 N/mm

Okay!

ke * f r
0.48 N/mm

Okay!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C103)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


b

A. Parameters
b =

400 mm

d =

1200 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

14000 kN

M* =
Nu =

3466 kN-m

Mu =

233 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

Link Diameter =
=

10 mm
0.6

150 mm

10000 kN
X

No. of Bars (X-dir.) =

No. of Legs (X-dir.) =

No. of Bars (Y-dir.) =

10

No. of Legs (Y-dir.) =

10

B. Calculations
Link Area =
bc =
dc =

79 mm

Clear Spacing (x) =

60 mm

290 mm
1090 mm

Clear Spacing (y) =


Min. Spacing =

92 mm
200 mm

Bars bundled =
Smax =

300 mm

Ac = 316100 mm

Clause 10.7.3.1.b

No

Check if column need not be designed using Clause 10.7.3.3:


a.)
N* 0.3 fc' Ag
0.3 fc' Ag =
=

0.6 x 0.3 x 56 x 480000


4838 kN
< N* Detail using Clause 10.7.3.3

0.25 > (M*/0.6Mu) + (N*/0.6Nu)

b.)

(M*/0.6Mu) + (N*/0.6Nu) = (3466/0.6*233) + (14000/0.6*10000)


= 620.1 >0.25 Detail using Clause 10.7.3.3
Since both criteria fail, fitments must be detailed using Clause 10.7.3.3
Clause 10.7.3.1 c

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

Along X- Direction
fr = [(No. of Legs x Alink x fyL)/(s x bc)]

Along Y- Direction
fr = [(No. of Legs x Alink x fyL)/(s x ds)]

= [(2 x 79 x 460)/(150 x 290)]

= [(10 x 79 x 460)/(150 x 1090)]

= 1.66 N/mm

= 2.21 N/mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 2
w = 60 mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 10
w = 92 mm

ke = 0.688

ke = 0.659

fr, eff =

fr, eff =

ke * f r
1.14 N/mm

Okay!

ke * f r
1.46 N/mm

Okay!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C106)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


b

A. Parameters
b =

400 mm

d =

1500 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

21200 kN

M* =
Nu =

6658 kN-m

Mu =

2982 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

32 mm

Link Diameter =
=

10 mm
0.6

150 mm

10000 kN
X

No. of Bars (X-dir.) =

No. of Legs (X-dir.) =

No. of Bars (Y-dir.) =

12

No. of Legs (Y-dir.) =

12

B. Calculations
Link Area =
bc =
dc =

79 mm

Clear Spacing (x) =

51 mm

290 mm
1390 mm

Clear Spacing (y) =


Min. Spacing =

91 mm
200 mm

Bars bundled =
Smax =

300 mm

Ac = 403100 mm

Clause 10.7.3.1.b

No

Check if column need not be designed using Clause 10.7.3.3:


a.)
N* 0.3 fc' Ag
0.3 fc' Ag =
=

0.6 x 0.3 x 56 x 600000


6048 kN
< N* Detail using Clause 10.7.3.3

0.25 > (M*/0.6Mu) + (N*/0.6Nu)

b.)

(M*/0.6Mu) + (N*/0.6Nu) = (6658/0.6*2982) + (21200/0.6*10000)


=

26.3 >0.25 Detail using Clause 10.7.3.3

Since both criteria fail, fitments must be detailed using Clause 10.7.3.3
Clause 10.7.3.1 c

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

Along X- Direction
fr = [(No. of Legs x Alink x fyL)/(s x bc)]

Along Y- Direction
fr = [(No. of Legs x Alink x fyL)/(s x ds)]

= [(2 x 79 x 460)/(150 x 290)]

= [(12 x 79 x 460)/(150 x 1390)]

= 1.66 N/mm

= 2.08 N/mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 2
w = 51 mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 12
w = 91 mm

ke = 0.700

ke = 0.673

fr, eff =

fr, eff =

ke * f r
1.16 N/mm

Okay!

ke * f r
1.40 N/mm

Okay!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C113)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


b

A. Parameters
b =

300 mm

d =

900 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

7900 kN

M* =
Nu =

1500 kN-m

Mu =

92 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

Link Diameter =
=

10 mm
0.6

150 mm

10000 kN
X

No. of Bars (X-dir.) =

No. of Legs (X-dir.) =

No. of Bars (Y-dir.) =

No. of Legs (Y-dir.) =

B. Calculations
Link Area =
bc =
dc =

79 mm

Clear Spacing (x) =

53 mm

190 mm
790 mm

Clear Spacing (y) =


Min. Spacing =

126 mm
150 mm

Bars bundled =
Smax =

300 mm

Ac = 150100 mm

Clause 10.7.3.1.b

No

Check if column need not be designed using Clause 10.7.3.3:


a.)
N* 0.3 fc' Ag
0.3 fc' Ag =
=

0.6 x 0.3 x 56 x 270000


2722 kN
< N* Detail using Clause 10.7.3.3

0.25 > (M*/0.6Mu) + (N*/0.6Nu)

b.)

(M*/0.6Mu) + (N*/0.6Nu) = (1500/0.6*92) + (7900/0.6*10000)


= 740.2 >0.25 Detail using Clause 10.7.3.3
Since both criteria fail, fitments must be detailed using Clause 10.7.3.3
Clause 10.7.3.1 c

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

Along X- Direction
fr = [(No. of Legs x Alink x fyL)/(s x bc)]

Along Y- Direction
fr = [(No. of Legs x Alink x fyL)/(s x ds)]

= [(2 x 79 x 460)/(150 x 190)]

= [(6 x 79 x 460)/(150 x 790)]

= 2.54 N/mm

= 1.83 N/mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 2
w = 53 mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 6
w = 126 mm

ke = 0.544

ke = 0.490

fr, eff =

fr, eff =

ke * f r
1.38 N/mm

Okay!

ke * f r
0.90 N/mm

Okay!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C113)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


b

A. Parameters
b =

300 mm

d =

700 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

6500 kN

M* =
Nu =

320 kN-m

Mu =

221 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

Link Diameter =
=

10 mm
0.6

150 mm

10000 kN
X

No. of Bars (X-dir.) =

No. of Legs (X-dir.) =

No. of Bars (Y-dir.) =

No. of Legs (Y-dir.) =

B. Calculations
Link Area =
bc =
dc =

79 mm

Clear Spacing (x) =

53 mm

190 mm
590 mm

Clear Spacing (y) =


Min. Spacing =

86 mm
150 mm

Bars bundled =
Smax =

300 mm

Ac = 112100 mm

Clause 10.7.3.1.b

No

Check if column need not be designed using Clause 10.7.3.3:


a.)
N* 0.3 fc' Ag
0.3 fc' Ag =
=

0.6 x 0.3 x 56 x 210000


2117 kN
< N* Detail using Clause 10.7.3.3

0.25 > (M*/0.6Mu) + (N*/0.6Nu)

b.)

(M*/0.6Mu) + (N*/0.6Nu) = (319.7/0.6*221) + (6500/0.6*10000)


=

7.0

>0.25 Detail using Clause 10.7.3.3

Since both criteria fail, fitments must be detailed using Clause 10.7.3.3
Clause 10.7.3.1 c

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

Along X- Direction
fr = [(No. of Legs x Alink x fyL)/(s x bc)]

Along Y- Direction
fr = [(No. of Legs x Alink x fyL)/(s x ds)]

= [(2 x 79 x 460)/(150 x 190)]

= [(6 x 79 x 460)/(150 x 590)]

= 2.54 N/mm

= 2.45 N/mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 2
w = 53 mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 6
w = 86 mm

ke = 0.524

ke = 0.493

fr, eff =

fr, eff =

ke * f r
1.33 N/mm

Okay!

ke * f r
1.21 N/mm

Okay!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C113)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


b

A. Parameters
b =

300 mm

d =

800 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

7600 kN

M* =
Nu =

1306 kN-m

Mu =

609 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

Link Diameter =
=

10 mm
0.6

150 mm

10000 kN
X

No. of Bars (X-dir.) =

No. of Legs (X-dir.) =

No. of Bars (Y-dir.) =

No. of Legs (Y-dir.) =

B. Calculations
Link Area =
bc =
dc =

79 mm

Clear Spacing (x) =

53 mm

190 mm
690 mm

Clear Spacing (y) =


Min. Spacing =

69 mm
150 mm

Bars bundled =
Smax =

300 mm

Ac = 131100 mm

Clause 10.7.3.1.b

No

Check if column need not be designed using Clause 10.7.3.3:


a.)
N* 0.3 fc' Ag
0.3 fc' Ag =
=

0.6 x 0.3 x 56 x 240000


2419 kN
< N* Detail using Clause 10.7.3.3

0.25 > (M*/0.6Mu) + (N*/0.6Nu)

b.)

(M*/0.6Mu) + (N*/0.6Nu) = (1306/0.6*609) + (7600/0.6*10000)


=

14.4 >0.25 Detail using Clause 10.7.3.3

Since both criteria fail, fitments must be detailed using Clause 10.7.3.3
Clause 10.7.3.1 c

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

Along X- Direction
fr = [(No. of Legs x Alink x fyL)/(s x bc)]

Along Y- Direction
fr = [(No. of Legs x Alink x fyL)/(s x ds)]

= [(2 x 79 x 460)/(150 x 190)]

= [(8 x 79 x 460)/(150 x 690)]

= 2.54 N/mm

= 2.79 N/mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 2
w = 53 mm

2
ke = (1-nw /6Ac)(1-s/2bc)(1-s/2dc)
n = 8
w = 69 mm

ke = 0.536

ke = 0.514

fr, eff =

fr, eff =

ke * f r
1.36 N/mm

Okay!

ke * f r
1.43 N/mm

Okay!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C111)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


A. Parameters
d =

1200 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

32000 kN
6961 kN-m
3688 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

M* =
Nu =

Link Diameter =

12 mm

Mu =

0.6

No. of Bars =

58

150 mm

10000 kN

No. of Legs =

B. Calculations
Link Area =
dcore =

Clause 10.7.3.1 c

113 mm
1088 mm

Min. Spacing =

300 mm

Bars bundled =
Smax =

No
300 mm

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

fr

= [(No. of Legs x Alink x fyL)/(s x bc)]


= [(4 x 113 x 460)/(150 x 1088)]
= 1.28 N/mm

2
ke = (1 - s/2ds)

150

ds =

1.11 N/mm

Okay!

s =
ke = 0.867
fr, eff =
=

ke * f r

1090 mm

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C112)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


A. Parameters
d =

500 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

6300 kN
497 kN-m
82 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

M* =
Nu =

Link Diameter =

12 mm

Mu =

0.6

No. of Bars =

16

150 mm

10000 kN

No. of Legs =

B. Calculations
Link Area =
dcore =

Clause 10.7.3.1 c

113 mm
388 mm

Min. Spacing =

250 mm

Bars bundled =
Smax =

No
300 mm

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

fr

= [(No. of Legs x Alink x fyL)/(s x bc)]


= [(3 x 113 x 460)/(150 x 388)]
= 2.68 N/mm

2
ke = (1 - s/2ds)

150

ds =

1.84 N/mm

Okay!

s =
ke = 0.687
fr, eff =
=

ke * f r

438 mm

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN C117)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


A. Parameters
d =

1000 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

21000 kN
4097 kN-m
519 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

M* =
Nu =

Link Diameter =

12 mm

Mu =

0.6

No. of Bars =

34

150 mm

10000 kN

No. of Legs =

B. Calculations
Link Area =
dcore =

Clause 10.7.3.1 c

113 mm
888 mm

Min. Spacing =

300 mm

Bars bundled =
Smax =

No
300 mm

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

fr

= [(No. of Legs x Alink x fyL)/(s x bc)]


= [(4 x 113 x 460)/(150 x 888)]
= 1.56 N/mm

2
ke = (1 - s/2ds)

150

ds =

1.32 N/mm

Okay!

s =
ke = 0.846
fr, eff =
=

ke * f r

938 mm

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (COLUMN TC1 - B2 TO UGF)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


A. Parameters
d =

2000 mm

f'c =

56 N/mm

Spacing =

fy = 460 N/mm

N* =

21000 kN
4164 kN-m
537 kN-m

Concrete Cover =

50 mm

Main Bar Diameter =

25 mm

M* =
Nu =

Link Diameter =

12 mm

Mu =

0.6

No. of Bars =

34

150 mm

10000 kN

No. of Legs =

B. Calculations
Link Area =
dcore =

Clause 10.7.3.1 c

113 mm
1888 mm

Min. Spacing =

300 mm

Bars bundled =
Smax =

No
300 mm

Min. effective confining pressure (frmin) = 0.015 fc' = 0.84 N/mm

Clause 10.7.3.3

fr

= [(No. of Legs x Alink x fyL)/(s x bc)]


= [(4 x 113 x 460)/(150 x 1888)]
= 0.73 N/mm

2
ke = (1 - s/2ds)

s =

150

ds =

1938 mm

ke = 0.924
fr, eff =
=

ke * f r
0.68 N/mm

<frmin Increase Links!

DOCUMENT NO.

SHEET

MQ000090
SUBJECT

LATERAL REINFORCEMENT CHECK (TC9 - 5F TO UNDERSIDE OF 9F)

SUBJECT

CALCULATIONS

OUTPUT

Link Reinforcement Check to AS 3600-2009


A. Parameters
d =

1000 mm

f'c =

28 N/mm

Spacing =

fy = 460 N/mm

N* =

928 kN
0 kN-m
222000 kN
110000 kN-m

Concrete Cover =

40 mm

Main Bar Diameter =

25 mm

M* =
Nu =

Link Diameter =

12 mm

Mu =

0.6

No. of Bars =

254

150 mm

No. of Legs =

B. Calculations
Link Area =
dcore =

Clause 10.7.3.1 c

113 mm
908 mm

Min. Spacing =

300 mm

Bars bundled =
Smax =

No
300 mm

Min. effective confining pressure (frmin) = 0.015 fc' = 0.42 N/mm

Clause 10.7.3.3

fr

= [(No. of Legs x Alink x fyL)/(s x bc)]


= [(2 x 113 x 460)/(150 x 908)]
= 0.76 N/mm

2
ke = (1 - s/2ds)

150

ds =

0.65 N/mm

Okay!

s =
ke = 0.846
fr, eff =
=

ke * f r

938 mm

DOCUMENT NO.

SHEET

0001 - MN00175 - MNC - 00

OF

SUBJECT

SUBJECT

CALCULATIONS

OUTPUT

DOCUMENT NO.

SHEET

0001 - MN00175 - MNC - 00

OF

SUBJECT

SUBJECT

CALCULATIONS

OUTPUT

DOCUMENT NO.

SHEET

0001 - MN00175 - MNC - 00

OF

SUBJECT

SUBJECT

CALCULATIONS

OUTPUT

Potrebbero piacerti anche