Sei sulla pagina 1di 4

Tramo

A-B
B-C
C-D
D-E
E - Re
E-F
F - Wc1
F - Lv1
D-G
G - Wc2
G - Lv2
C-H
H - Ld
H - Fr

Mueble
Wc
Lv
Ld
Re
Fr

Instalacin hidrulica Agua Fra


Q mx. (Lps)
Coef. Sim.
Q mx. prob. (Lps)
Dimetro (m)
Longitud (m)
Accesorios
1.05
0.4082
0.4286
0.0268
3 TSL (1.7), Ve (0.2), TPD (0.4), E (0.3)
0.85
0.4082
0.3470
0.0268
2.5 TSB (1.7)
0.51
0.5
0.2550
0.0268
13.5 C90 (0.7), TSB (1.7)
0.34
0.7071
0.2404
0.0206
0.5 TPD (0.4)
0.17
1
0.1700
0.0206
1.5 2C90 (1.2), TSL (1.4), Ve (0.1)
0.17
1
0.1700
0.0206
1 TSL (1.4)
0.1
1
0.1000
0.0206
2.5 C90 (0.6)
0.07
1
0.0700
0.0206
3.4 2C90 (1.2)
0.17
1
0.1700
0.0268
5 TPD (0.5)
0.1
1
0.1000
0.0144
2.5 C90 (0.4)
0.07
1
0.0700
0.0144
4.4 3C90 (1.2)
0.34
1
0.3400
0.0268
1.5 TPD (0.5)
0.2
1
0.2000
0.0268
1.95 C90 (0.7)
0.14
1
0.1400
0.0206
6.4 3C90(1.8)

Presin (mca)
3.5
3.5
3.5
2.1
3.5

Long. Equiv. (m)


2.6
1.7
2.4
0.4
2.7
1.4
0.6
1.2
0.5
0.4
1.2
0.5
0.7
1.8

La norma establece una serie de presiones minimas para muebles hidrulicos, enunciadas a continuacin:
Utilizando la frmula CD = CDT - (H mueble + hf mueble)
Para Re: (1.5-(-1.5+0.1513+0.0199+0.0461+0.0689+0.0258+0.0631))=2.6249
Para Wc1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0258+0.0125))=3.5756
Para Lv1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0254))=3.5884
Para Wc2: (1.5-(-2.4+0.1513+0.0199+0.0461+0.1188))=3.5639
Para Lv2
Para Ld
Para Fr

2.6164
3.6257
3.5295
3.5972
3.5014
3.2266
3.6178

Por lo tanto los muebles conectados a tuberias de AC cumplen con las presiones mnimas, por ende con la Norma.
3.1766

Tramo
A-B
B - Cal
Cal - C
C-D
D-E

Q mx. (Lps)

Instalacin hidrulica Agua Caliente


Coef. Sim.
Q mx. prob. (Lps)
Dimetro (m)
Longitud (m)
Accesorios
1.05
0.4082
0.4286
0.0268
3 2TSL (3.4), Ve (0.2), E (0.3)
0.25
0.5774
0.1444
0.0206
0.95 2C90 (1.2)
0.21
0.5774
0.1213
0.0206
2.45 2C90(1.2), TSL (1.7), TSB (1.7)
0.14
0.7071
0.0990
0.0206
13.5 C90 (0.6), TSB (1.7)
0.11
1
0.1100
0.0144
0.5 TPD (0.3)

Long. Equiv. (m)


3.9
1.2
4.6
2.3
0.3

E - Re
E - Lv1
D - Lv2
C - Fr

Mueble
Wc
Lv
Ld
Re
Fr

0.08
0.03
0.03
0.07

Presin (mca)
3.5
3.5
3.5
2.1
3.5

1
1
1
1

0.0800
0.0300
0.0300
0.0700

0.0144
0.0144
0.0144
0.0144

1.5 2C90 (0.8), TSL (1.3), Ve (0.1)


4.4 2C90 (0.8)
9.4 3C90 (1.2)
7.9 3C90 (1.2)

La norma establece una serie de presiones minimas para muebles hidrulicos, enunciadas a continuacin:
Utilizando la frmula CD = CDT - (H mueble + hf mueble)
Para Re: (1.5-(-1.5+0.1513+0.0199+0.0461+0.0689+0.0258+0.0631))=2.6249
Para Lv1: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0258+0.0125))=3.5756
Para Lv2: (1.5-(-2.4+0.1513+0.0199+0.0461+0.0689+0.0254))=3.5884
Para Fr: (1.5-(-2.4+0.1513+0.0199+0.0461+0.1188))=3.5639
Ya que los muebles conectados a tuberias de AC cumplen con las presiones mnimas, la instalacin hidrulica cumple con la Norma.

2.2
0.8
1.2
1.2

Long. T (m)

hf (mca)
5.6
4.2
15.9
0.9
4.2
2.4
3.1
4.6
5.5
2.9
5.6
2
2.65
8.2

Long. T (m)

0.1228
0.0603
0.1234
0.0231
0.0540
0.0309
0.0138
0.0100
0.0190
0.0773
0.0731
0.0276
0.0127
0.0715

hf (mca)
6.9
2.15
7.05
15.8
0.8

0.1513
0.0199
0.0461
0.0689
0.0258

3.7
5.2
10.6
9.1

0.0631
0.0125
0.0254
0.1188

Potrebbero piacerti anche