Sl.

No.
1.

Test

Specification

Vibration
a

Resonance search -1

Random Vibration
(Method 514.6
Fig. 514.6E-1)

Resonance Search 2*

2.

Freq. Range: 6 to 500 Hz


Acceleration: 0.5g
Sweep Rate: 1 octave / min,
Resonance is noted if response is 3 times the
stimulus.
Unit to be in OFF condition
Frequency
: 20 - 2000 Hz
PSD:
20 - 1000 Hz
: 0.04 g2/Hz
1000 - 2000 Hz : Linearly dropping @ - 6bB/Octave
1 Hrs / Axis with vibration Isolators and 30 min
without vibration isolators
Resonance search to be repeated after completing
random vibration. Shift on resonating frequency
should be less than 10% of original.

Mechanical Shock
d

Crash Hazard (NonOperational) (Method


516.6, Procedure - 5)

40 g saw tooth or 30g half-sine, 11 mSec Pulse


Width

2 shocks in each of six directions