Sei sulla pagina 1di 1

GENERAL SPECIFICATIONS

TO THE NEAREST POWER SOURCE

ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH

THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, THE
FIRE CODE OF THE PHILIPPINES, THE NATIONAL BUILDING CODE, THE RULES AND

USE 2 - 22 mm square THHN wire

REGULATIONS OF ENFORCING LOCAL GOVERNMENT, AND UNDER THE IMMEDIATE


SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER / MASTER ELECTRICIAN.
ONLY BRAND NEW DEVICES, EQUIPMENT MATERIALS AND SUPPLIES (DEMS) APPROVED

100 AT

BY THE BUREAU OF PRODUCT STANDARDS (BPS) OF THE DEPARTMENT OF TRADE AND


INDUSTRY (DTI) OR FOREIGN MADE PRODUCTS APPROVED BY INTERNATIONALLY

L.O.

15 AT

15 AT

RECOGNIZED TESTING ORGANIZATION SHALL BE USED IN THE PROJECT WHEN


L.O.

REQUIRED, THE SUPPLIER SHOULD FURNISH PROOFS REGARDING THE QUALITY OF


DEMS TO BE USED.

L.O.

15 AT

15 AT

L.O.

ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE " THWN " UNLESS
OTHERWISE INDICATED. THE MINIMUM SIZE FOR POWER CABLE SHALL BE 3.5 SQ. MM.

L.O.

15 AT

15 AT

L.O.

WIRES SHOULD BE COLOR CODED. RECOMMENDED COLOR FOR POWER FEEDERS ARE
BLACK, BLUE AND RED. FOR GROUND WIRE GREEN OR WHITE.

L.O.

15 AT

15 AT

REF.

ALL FLUORESCENT FIXTURES SHALL HAVE HIGH POWER FACTOR AND PRE - HEAT
BALLAST. LAMP SHALL BE COOL WHITE THROUGHOUT SPECIFIED AREA OF

RANGE

C.O.

11

15 AT

30 AT

15 AT

15 AT

10

C.O.

12

C.O.

APPLICATION.

THE MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS :


A.) LIGHTING SWITCHES ............... 1.40 M. ABOVE FLOOR FINISH
B.) CONVENIENCE OUTLET ........... 0.30 M. ABOVE FLR. FIN. OR AS REQUIRED

SPARE

C.) PANEL BOARDS & CABINETS... 1.60 M. ABOVE FLR. FIN. @ CENTER OR AS REQUIRED

SPARE

D.) KILOWATTHOUR METER .......... MIN. OF 1.2 M., MAX. OF 1.8 M. ABOVE FLOOR LINE. ALL
MOUNTING HEIGHTS SHALL BE SUBJECTED TO THE ARCHITECT'S / ENGINEER'S
APPROVAL PRIOR TO THE INSTALLATION.
BRAND NAMES MENTIONED IN THE PLANS AND SPECIFICATIONS ARE ONLY FOR THE
PURPOSE OF INDICATING THE DESIRED QUALITY BUT NOT TO LIMIT THE USE OF OTHER
BRANDS.

GROUND

TWO - STOREY RESIDENTIAL BLDG.

E
36 20

RISER DIAGRAM
NOT

DRAWN

TO

SCALE

PRESENTED BY:

SUBJECT:

MANAGBANAG, EMMANUEL II L.
MAGALLANES, EDRALYN

COMP TWO - STOREY RESIDENTIAL BLDG.


413

EVSU_CAAD_BSAR 4A STUDENT

PROJECT TITLE:

LOCATION:

CHECKED BY:

ARCH. HERVY G. CATILOGO, UAP


INSTRUCTOR
DATE CHECKED:

SHEET CONTENTS:

SCALE

RISER DIAGRAM

N.D.T.S.

N.D.T.S.

20 24

GENERAL SPECIFICATION

N.D.T.S.

SHEET NO.

ELECTRICAL