Sei sulla pagina 1di 2

1

1. Main Dimensions

Reference

Results

Book
(A.k. .

Input power supplied to rotor

KVA rating (S) =

Sawhney)

746 X HP

( x Cos)

Where;
Kw = Rated power of the machine = 7Kw
= Efficiency of the machine
Cos = Power Factor

Assumption:
Efficiency () = 85%
= 0.85

Cos = 0.9
Page
600

Therefore,
S=

746 X HP

Cos = 0.9

( x Cos)
=

0.9 x 0.85
S = 9.15 KVA

Numbers Of Poles and Synchronous Speed:

S=9.15 KVA

Number of poles = 120 x f


NS
P = 120 x 50
Pole 6
1000

Pole 1

= 6 poles
ns = 1000/60 rps
= 16.67 rps

Pole 5
2

Pole 4

Output Coefficient:

Pole

Poles = 6
ns = 16.67 rps

Pole 3