Sei sulla pagina 1di 7

Folha.de.

Rosto_2

Client:

PUMA ENERGY SERVICES SOUTH AFRICA

Site Location:

CDIZ ESPANHA

Project:

REVERSE ENGINEERING PROJECT - TYPICAL BITUMEN T

Document n:

167.04.12-LP602

Client Reference:

P-AGLFPE-LS-167.04.12-PRO-602

EQUIPMENT LIST
FIRE FIGHTING

Pgina 1

Folha.de.Rosto_2

DISCIPLINE: PROCESS/ EQUIPMENT/ PIPPING/ CIVIL/ ARQUITECTURE/ ELECTRICITY/ INSTRUMENTATION/ AUTOMATION


PROJECT MANAGER: Jos Silva

07-08-12

FOR APPROVAL

VC

JS

HM

Revision:

Date:

Issued for:

Executed by:

Checked by:

Approved by:

This document and all its information are property of Projecto.Detalhe, Lda. Copies and reproductions are not allowed without proper authorization. Consult site www.projectodetalhe.com for m
Model 42 - Revision 4

Pgina 2

Folha.de.Rosto_2

CA

TYPICAL BITUMEN TERMINAL

Pgina 3

Folha.de.Rosto_2

ION/ AUTOMATION

HM
Approved by:

Approved by (Client):

on. Consult site www.projectodetalhe.com for more information.

Pgina 4

Modelo 42

FIRE FIGHTING EQUIPMENT LIST

Reviso 4

ITEM

Equipment identification

TAG N

TK-700

TK-700

P&ID

DP202 Sheet
1 of 2
DP202
Sheet 2 of 2

CUSTOMER:

PUMA ENERGY

SITE:

CDIZ

JOB:

REVERSE ENGINEERING PROJECT - TYPICAL BITUMEN TERMINAL

LOCAL:

ESPANHA

DOCUMENT N:

167.04.12-LP602

PROCESS CONDITIONS

MATERIAL

SERVIO
SERVICE

Equipment list

07-08-2012

VC

JS

HM

REV.

DESCRIO/DESCRIPTION

DATA/DATE

EMITIDO/ISSUED

VERIFICADO/VERIFIED

APROVADO/APPROVED

EQUIPMENT

FLUDO
FLUID

FORNECEDOR
SUPPLIER

MATERIAL

Dimensions

NORMAS
LAW

DN

PN

in

(#)

PROJECT IDENTIFICATION
LIGAO
PROCESSO
PROCESS
CONNECTION

ACCESSORIES
ISOMTRICA
ISOMETRIC

LINHA
LINE

DATA-SHEET

OBSERVATIONS

n.a.

Supply Fire Water

Fire water

Water tank

Volume = 2400 m3

n.a.

Supply Fire Water

FIre water

Water tank

Volume = 500 m3

n.a.

Fire water pump

Fire water

Diesel pump

n.a.

Fire water pump

Fire water

Diesel pump

n.a.

Fire water pump

Fire water

Diesel pump

n.a.

Fire water pump

Fire water

Jockey pump

n.a.

Fire water pump

Fire water

Diesel pump

n.a.

Fire water pump

Fire water

Diesel pump

n.a.

Fire water pump

Fire water

Jockey pump

3
4

P-701

P-702

P-703

P-704

DP202 Sheet
1 of 2
DP202 Sheet
1 of 2
DP202 Sheet
1 of 2
DP202 Sheet
1 of 2

8
9

P-701

10

P-702

11

P-703

DP202 Sheet
2 of 2
DP202 Sheet
2 of 2
DP202 Sheet
2 of 2

12
HI-701

DP202 Sheet
1 of 2

n.a.

LOADING GANTRY AREA

Fire water

Hydrant

4"

150#

FLGD

HI-702

DP202 Sheet
1 of 2

n.a.

WAREHOUSE AREA

Fire water

Hydrant

4"

150#

FLGD

15

HI-703

DP202 Sheet
1 of 2

n.a.

Cooling Tanks

Fire water

Hydrant

4"

150#

FLGD

16

HI-704

DP202 Sheet
1 of 2

n.a.

Cooling Tanks

Fire water

Hydrant

4"

150#

FLGD

HI-705

DP202 Sheet
1 of 2

n.a.

Cooling Tanks

Fire water

Hydrant

4"

150#

FLGD

18

HI-706

DP202 Sheet
1 of 2

N.a.

Cooling Tanks

FIre water

Hydrant

4"

150#

FLGD

19

HI-707

DP202 Sheet
1 of 2

N.a.

Cooling Tanks

FIre water

Hydrant

4"

150#

FLGD

21

HI-701

DP202 Sheet
2 of 2

n.a.

LOADING GANTRY AREA

Fire water

Hydrant

22

HI-702

DP202 Sheet
2 of 2

n.a.

WAREHOUSE AREA

Fire water

Hydrant

HI-703

DP202 Sheet
2 of 2

n.a.

Cooling Tanks

FIre water

Hydrant

24

HI-704

DP202 Sheet
2 of 2

n.a.

Cooling Tanks

FIre water

Hydrant

25

HI-705

DP202 Sheet
2 of 2

n.a.

Cooling Tanks

FIre water

Hydrant

HI-706

DP202 Sheet
2 of 2

n.a.

Cooling Tanks

FIre water

Hydrant

HI-707

DP202 Sheet
2 of 2

n.a.

Cooling Tanks

FIre water

Hydrant

13
14

17

20

23

26
27

167.04.12-LP602-Fire Fighting Equipment List-rev0.ods- LEQUIP-DIVERSOS

5 de 7

Modelo 42

FIRE FIGHTING EQUIPMENT LIST

Reviso 4

ITEM

Equipment identification

TAG N

P&ID

CUSTOMER:

PUMA ENERGY

SITE:

CDIZ

JOB:

REVERSE ENGINEERING PROJECT - TYPICAL BITUMEN TERMINAL

LOCAL:

ESPANHA

DOCUMENT N:

167.04.12-LP602

PROCESS CONDITIONS

MATERIAL

Equipment list

07-08-2012

VC

JS

HM

REV.

DESCRIO/DESCRIPTION

DATA/DATE

EMITIDO/ISSUED

VERIFICADO/VERIFIED

APROVADO/APPROVED

EQUIPMENT

SERVIO
SERVICE

FLUDO
FLUID

FORNECEDOR
SUPPLIER

MATERIAL

Dimensions

NORMAS
LAW

PROJECT IDENTIFICATION

DN

PN

in

(#)

LIGAO
PROCESSO
PROCESS
CONNECTION

ACCESSORIES
ISOMTRICA
ISOMETRIC

LINHA
LINE

DATA-SHEET

OBSERVATIONS

28
29

HM-701

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

30

HM-702

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

HM-703

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

32

HM-705

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

33

HM-706

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

34

HM-707

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

HM-708

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

HM-709

DP202 Sheet
1 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

HM-701

DP202 Sheet
2 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

39

HM-702

DP202 Sheet
2 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

40

HM-703

DP202 Sheet
2 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

HM-704

DP202 Sheet
2 of 2

n.a.

Fire Fighting Sytem

Foam

Monitor with Foam connection

F-701

DP202 Sheet
1 of 2

n.a.

Input Fire Water pumps

Fire water

Filter Y

12"

150#

FLGD

F-702

DP202 Sheet
1 of 2

n.a.

Input Fire Water pumps

Fire water

Filter Y

12"

150#

FLGD

45

F-703

DP202 Sheet
1 of 2

n.a.

Input Fire Water pumps

Fire water

Filter Y

12"

150#

FLGD

46

F-704

DP202 Sheet
1 of 2

n.a.

Input Fire Water pumps

Fire water

Filter Y

3"

150#

FLGD

48

F-701

DP202 Sheet
2 of 2

n.a.

Input Fire Water pumps

Fire water

Filter Y

10"

150#

FLGD

49

F-702

DP202 Sheet
2 of 2

n.a.

Input Fire Water pumps

FIre water

Filter Y

10"

150#

FLGD

F-703

DP202 Sheet
2 of 2

n.a.

Input Fire Water pumps

FIre water

Filter Y

3"

150#

FLGD

31

35
36
37
38

41
42
43
44

47

50
51

167.04.12-LP602-Fire Fighting Equipment List-rev0.ods- LEQUIP-DIVERSOS

6 de 7

Modelo 42

FIRE FIGHTING EQUIPMENT LIST

Reviso 4

ITEM

Equipment identification

TAG N

P&ID

CUSTOMER:

PUMA ENERGY

SITE:

CDIZ

JOB:

REVERSE ENGINEERING PROJECT - TYPICAL BITUMEN TERMINAL

LOCAL:

ESPANHA

DOCUMENT N:

167.04.12-LP602

PROCESS CONDITIONS

MATERIAL

SERVIO
SERVICE

Equipment list

07-08-2012

VC

JS

HM

REV.

DESCRIO/DESCRIPTION

DATA/DATE

EMITIDO/ISSUED

VERIFICADO/VERIFIED

APROVADO/APPROVED

EQUIPMENT

FLUDO
FLUID

FORNECEDOR
SUPPLIER

MATERIAL

Dimensions

NORMAS
LAW

DN

PN

in

(#)

PROJECT IDENTIFICATION
LIGAO
PROCESSO
PROCESS
CONNECTION

ACCESSORIES
ISOMTRICA
ISOMETRIC

LINHA
LINE

DATA-SHEET

OBSERVATIONS

52
OBSERVAES:

167.04.12-LP602-Fire Fighting Equipment List-rev0.ods- LEQUIP-DIVERSOS

7 de 7