Fault
code
Fault description
Display
000
004
005
009
010
011
012
No faults
Comments
Remedial action
overheating
sensor (combination
sensor)
013
Overheating at the
flame sensor
(combination sensor)
014
Temperature
difference between
flame sensor and
overheating
sensor too large
015
Operating lock-out
017
Overheating
020
Glow plug
interruption
021
022
025
030
031
032
Check glow plug lead harness for correct laying and damage, if
ok > check
lead harness for continuity, if ok > replace control box,
carry out
the functional check
with max.
11.3 volt.
In the 24 volt heater,
carry out
the functional check
with max.
23.6 volt.
The component is
destroyed if
the voltage values are
exceeded.
Ensure the power pack
has
adequate short-circuit
resistance min. 20
A.
034
047
048
049
050
Check that the lead harness of the blower motor has been
correctly laid and
check for damage, if ok > remove lead harness at control box
and check for
continuity, if ok > replace control box.
Remove connector from the metering pump, if the fault code
048 (interruption)
is displayed the metering pump is defective > replace metering
pump.
Metering pump short
If the fault code 047 continues to be displayed, disconnect
circuit or
connector S1 / B1
overload
at the heater, and at the connector B1, PIN 5 check the cable 12
gn / rt up to
the metering pump for short circuit to negative (PIN 10), if ok >
replace control box.
Remove connector from the metering pump and measure the
resistance value
of the metering pump (12 V = 9,5 0.5 / 24 V = 36 1.8
Metering pump
), if resistance
interruption
value ok > reconnect cable loom to the metering pump.
Disconnect connector S1 / B1 at the heater and measure the
resistance value
between PIN 5 and PIN 10, if ok > replace control box.
Metering pump outlet Check that the lead harness of the metering pump has been
(+),
correctly laid and
short circuit after UB check for damage, if ok > remove lead harness and check for
(battery
continuity,
voltage)
if ok > replace control box.
Too many failed start The control box locks after too many failed start attempts (max.
attempts
255 start
(operating lock-out) attempts).
Blower motor outlet
(+), short
circuit after UB
(battery voltage)
051
052
053
054
055
056
060
061
Unlock the control box by deleting the fault memory using the
EDiTH customer
service program, diagnostic unit or various control units.
If, after being switched on, the resistance value of the flame
sensor is 1274
(> 70 C) the heaters fan rungs for approx. 15 min to cool down,
Flame detected when
if the resistance
switching
does not fall below the aforementioned value within 15 min the
on
heater is switched
off.
Check the flame sensor.
No flame detected during the start phase.
Check exhaust and combustion air system.
Safety time exceeded Check fuel supply / measure fuel quantity,
Check spark plug (see fault code 020 and 021).
Check flame sensor, if ok > replace control box.
The heater has ignited (flame detected) and signals flame cutout
Flame cutout in the
during a power
POWER control
stage.
stage
Check exhaust and combustion air system.
HIGH control stage
Check fuel supply / measure fuel quantity, see page 33.
MEDIUM control
Check flame sensor, for diagram and table of values please refer
stage
to page 30, if
LOW control stage
ok > replace control box.
Disconnect the plug-in connection of the external room
temperature sensor
and measure the resistance value, see page 9 for diagram and
values table, if
temperature sensor ok > reconnect plug-in connection.
External room
Disconnect connector S1 / B1 at the heater and measure the
temperature
resistance value
sensor interruption
in connector housing B1 between PIN 6 and PIN 12. If an
interruption exists
the ohmic value between PIN 6 and PIN 12 > 3000 . If
resistance value ok
> replace control box.
Disconnect plug-in connection of the external room temperature
sensor, if error
code 060 is displayed > check external room temperature sensor,
see
page 9 for diagram and values table.
External room
If external room temperature sensor ok > check the connection
temperature
cables 0.52 gr
sensor short circuit and 0.52 br/ws for short circuit, if ok > reconnect plug-in
connection.
Disconnect connector S1 / B1 at the heater and measure the
resistance value
in connector housing B1 between PIN 6 and PIN 12.
If a short circuit exists the ohmic value between PIN 6 and PIN
062
Control unit
interruption
063
064
Flame sensor
(combination
sensor) interruption
065
Flame sensor
(combination
sensor) short circuit
071
Overheating sensor
interruption
072
Overheating sensor
short
circuit
12 < 800 . If
the error 061 continues to be displayed, > replace control box.
Remove connector at the control unit and measure the resistance
value of the
setpoint potentiometer, for connector pins. If the resistance value
is ok > reconnect connector at the control unit.
Disconnect connector S1 / B1 at the heater and measure the
resistance value
between PIN 6 and PIN 7 in the connector housing B1, if
resistance value is ok
> replace control box,
Resistance value in case of interruption between PIN 6 and PIN 7
> 3000 .
Normal value: 1750 30 2180 80 .
If Ventilate switch is installed, disconnect it and check it is
working. If ok >
disconnect the connector at the control unit, if error code 062 is
displayed, replace
control unit.
If control unit ok > check connection cables 0.52 gr / rt and
0.52 br / ws for
short circuit, if ok > reconnect connector at control unit.
Disconnect connector S1 / B1 at the heater, if the error 063
continues to be
displayed > replace control box.
Resistance value in case of short circuit between PIN 6 and PIN 7
< 800 .
Normal values: 1750 30 2180 80 .
Dismantle control box and disconnect green connector from
control box.
Check flame sensor, for diagram and table of values, if flame
sensor ok > replace control box.
Resistance value in case of interruption > 3000 .
Dismantle control box, remove green connector from control
box, if error 064
is displayed > replace combination sensor.
If error 065 continues to be displayed > replace control box,
Resistance value in case of short circuit < 500 ,
Dismantle control box, disconnect blue and green connectors
from control
box. Measure resistance value at the blue connector PIN 1 (cable
0.52 bl) and
at the green connector PIN 2 (cable 0.52 br / ws), if ok > replace
control box,
Resistance value in case of interruption >700 k,
Dismantle control box, remove blue connector from control box,
if error 071 is
displayed > replace combination sensor, see Page 27.
074
090
2
093
094
095
096
097
098
099
Cdigo
de fallo
Display
Comentarios
Las medidas correctivas
000
No hay fallos
004
Advertencia:
Corto circuito en la caja de
control, fresco
salida de aire
005
Advertencia:
Corto circuito en la caja de
control, el coche
salida de alarma
009
ADR apagado
Recorte de sobretensin
011
012
013
El sobrecalentamiento en el
010
sensor de llama
(Sensor de combinacin)
014
015
017
demasiado alta.
Compruebe las tuberas de aire caliente de bloqueo -> Quitar bloqueo.
La suma de las puntuaciones de componentes de aire conductor partes es
demasiado grande -> Check aire
sistema si es necesario re-lay - para las calificaciones de los componentes,
consulte adicional
Lista de piezas.
Compruebe el sensor de llama, si bien -> Comprobar sensor
sobrecalentamiento, si el sensor de sobrecalentamiento
defectuosa -> reemplace el sensor de combinacin, si el sensor de
sobrecalentamiento ok -> medida
Funcionamiento bloqueo
Calentamiento excesivo
020
021
Produccin de bujas de
incandescencia (-), sobrecarga
o
tierra de cortocircuito
022
Buja de precalentamiento, la
salida (+), corto
circuito despus de UB (voltaje
de la batera)
025
030
031
Verificar que el mazo de cables del motor del ventilador est bien instalado
y
por los daos, si bien -> quitar el arns de plomo en la caja de control y
verificar la continuidad,
si bien -> reemplazar la caja de control.
032
El componente se destruye si
se exceden los valores de
tensin.
Asegrese de que la fuente de
alimentacin tiene
adecuada de cortocircuito
resistencia - min. 20 A.
034
047
Verificar que el mazo de cables del motor del ventilador est bien instalado
y
comprobar los daos, si bien -> eliminar mazo de cables en la caja de
control y comprobar
continuidad, si bien -> reemplazar la caja de control.
Retire el conector de la bomba de dosificacin, si el cdigo de error 048
(interrupcin)
Se muestra la bomba dosificadora es defectuoso -> cambiar la bomba
dosificadora.
Si el cdigo de error 047 se sigue mostrando, desconecte el conector S1 /
B1
en el calentador, y en el conector B1, PIN 5 compruebe el cable 12 gn / rt
hasta
la bomba dosificadora de cortocircuito hacia el negativo (PIN 10), si bien ->
reemplazar la caja de control.
048
Interrupcin de la bomba de
medicin
049
Demasiados intentos de
arranque fallidos
(Operando bloqueo)
050
051
052
053
054
055
056
Llama recorte en el
Etapa de control "POWER"
Etapa de control "HIGH"
Etapa de control "MEDIA"
Etapa de control "LOW"
060
061
062
063
064
de control.
Compruebe el sensor de la llama, para el diagrama y la tabla de valores, si el
sensor de llama ok -> reemplazar la caja de control.
Valor de resistencia en caso de interrupcin> 3000 .
Desmontar el cuadro de control, retire el conector verde de la caja de
control, en caso de error 064
aparece -> reemplazar sensor combinado.
Si el error 065 sigue apareciendo -> reemplazar la caja de control,
Valor de resistencia en caso de cortocircuito <500 ,
065
071
072
074
090
093
094
095
096
097
098
Demasiados reinicios en
secuencia
099
Transistor error en la caja de
control
Tensin de corto plazo <5 - 6 voltios (para 12 voltios) o <7-8 voltios (para
24 voltios).
En caso de cada de tensin, controle los fusibles, los cables de
alimentacin, las conexiones negativas
y el punto de apoyo positivo de la batera de la corrosin y correcta
contacto.
Caja de control de prueba con el dispositivo de prueba, si bien ->
compruebe el haz principal del exterior
componentes se ha realizado correctamente y comprobar los daos, si bien > comprobar
llevar arns de continuidad, si bien -> reemplazar la caja de control.