Sei sulla pagina 1di 3

center for the designed environment profession +jeremiah sunga queddeng

FIRE CODE

Assembly

Residential
a. Dorms
b. Apartment
c. Hotel

Institutional
a. room to exit
b. point in room to exit
c. suite

Educational
a. Child Day Care
a.1 room to exit
a.2 point in room to exit
a.3 sleeping room

Mercantile
a. hi hazard
Business
a. ground

Industrial
a. hi hazard
Storage

Distance to Exit

Dead Ends

Aisles

46m w/o FFS


61m w/ FFS

6.1

<60 seats - 0.76


>60 seats:
0.91 (1 side); 1.0 (2 sides)

Hospital & Nursing - 2.44


Resi Custodian - 1.83
Common Aisle - 1.83

30.48 w/o FFS


46m w/ FFS
15.5m
15.5 (room to exit)
30m (travel to exit)

30 w/o FFS
45 w/ FFS
46 w/o FFS
61 w/FFS
15 w/ FFS
30 w/o FFS

46 w/o FFS
61 w/ FFS
30.5 w/o FFS
45.75 w/ FFS
48.8 w/o FFS
60.05 w/ FFS
15.25 w/o FFS
30.5 w/ FFS
30.5 w/o FFS
46 w/ FFS
23

Class A - 1.5

30.5
61 w/o FFS
91.5 w/ FFS
31 w/o FFS
46 w/ FFS
23
23 w/o FFS
30.5 w/ FFS

15.5

1.5 corridor

center for the designed environment profession +jeremiah sunga queddeng


a. garage

b. hanger
b.1 internval of distance
b.2 interval of hori exit
b.3 mezzanine

46 w/o FFS
61 w/ FFS

46
30.5
27

STANDPIPE

FIRE DOOR

DRY STANDPIPE
Size
23 m or less
more than 23 m
outlet

Class A - 3 hrs

openings thru a wall separating


bldgs or dividing bldg into fire
areas

Class B - 1 hr or
1 1/2 hrs

opening in enclosure of vertical


transpo in bldgs (stairs, elevs., )

Class C - 3/4 hr

corridor and room partitions

Class D - 1 1/2 hrs

door/shutters in exterior walls


subject to severe fire exposure

Class E and F 3/4 hr

subject to moderate or light


fire exposure

height from ffl

WET STANDPIPE
Size
15 m or less
more than 15 m
outlet
height from ffl

COMBINATION
Size
outlet
height from ffl

102 mm
153 mm
64 mm
min. 46 cm
max. 122cm

51 mm
64 mm
38 mm
min. 91 cm
max 182 cm

150 mm
64 mm
min. 61 cm
max. 122 cm

STAIRS

Class A

Class B

min. width

112 cm

112 cm
91 cm < 50 O.L.

max ht. of riser

19 cm

min. thread

25 cm

23 cm

headroom

2m

2m

112 cm

112 cm

landing

center for the designed environment profession +jeremiah sunga queddeng


STAIRS
Class A
Class B
max ht. between landings

2.75 m

3.70 m

RAMPS

Class A

Class B

112 cm or >

76 - 112 cm

slope

8 -10 %

10 - 17 %

max ht. between landings

no limit

3.66 m

min. width

FLAME SPREAD RATING


Interior Finish
Class A
Class B
Class C
Class D
Class E

Flame Spread
25
26-75
76-200
201-500
>500

Potrebbero piacerti anche