PROJECT :

DESIGN
CALCULATION

PAGE
NO

Lusail Tower
DSG

CHK APPD

WIND LOAD CALCULATION

Effective Building height above


1) ground level

Shaikh A.M
8.1

Hr

2) Type of Building

RCC FRAME

3) Building type factor Kb

( As Per BS 6399 - 2 1997


From table -1)

As Per BS 6399-2 1997 From Figure 3 Cr can be interpolated


4) Dynamic Augmentation factor Cr

0.015

Since Cr < 0.25 & H < 300 m , BS 6399 Apply.


5) Basic wind speed Vb

30 m/sec

6) Calculation of Site Wind Speed (Vs)

= Vb * Sa * Sd * Ss * Sp

As Per BS 6399-2 1997 From Figure 3 Cr can be interpolated


Sa

= 1+ 0.001 s

Use s conservatively = 10 m
=

1.010 (Section 2.2.2.2)

Sd

1.000 (Section 2.2.2.3)

Ss

1.000 (Section 2.2.2.4)

Sp

1.000 (Section 2.2.2.5)

Vs

Ve

= Vs * Sb

30.3

m/sec

As Per BS 6399-2 1997 Table -4 Factor for Sb shall be for the worst case

7) Calculation of Dynamic Pressure (qs)

Sb

1.78

Ve

53.93

= 0.613 * Ve

m/sec

1783.141

1.783

N/m

2
2

KN/m