Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
DESIGNED BY:
HERMINIO C. SIMBOL
ARCHITECT
CHECKED BY:
BATANGAS
SUBMITTED BY:
RECOMMENDING APPROVAL:
APPROVED BY:
FLORENCIA G. CORDOVA
BENCIO A. AGUZAR
JULIANA D. VERGARA
Officer - in - Charge
A
A-1
1.20
3
21.00
NTS
TO
PU BALA
NT
Y
A D TIGU
EL
E
FU /
EG
O
P E R S P E C T I V E
2.00
IL
AM
OH
STAGE
.40
1.20
A
RO
TE
UP
1.20
TE
A
N
12.00
EXISTING
MULTI-PURPOSE
BUILDING
NASUG
BU
-
UP
TA LIN
BA Y
1.93
.20
.40
1.20
STAGE
EARTH
LINE OF ROOF
EAVES ABOVE
EARTH
BARANGAY NATIPUAN
2.72
G
SU
NA R
TO OPE
PR
22.68
BU
B
A-1
C
A-1
SHEET CONTENT:
DESIGNED BY:
BATANGAS
PERSPECTIVE
SITE DEVELOPMENT PLAN
LOCATION MAP
VICINITY MAP
D
A-1
LOCATION MAP
NTS
SUBMITTED BY:
RECOMMENDING APPROVAL:
V I C I N I T Y
M A P
NTS
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
A-1
1
SUMMARY OF QUANTITIES
DESCRIPTION
ITEM NO.
A.1.1.
LINE OF ROOF
EAVES ABOVE
EXISTING STAGE
COLUMN
21.00
.60
5.25
5.25
5.25
5.25
.60
2.70
1.75
STAGE
.40
LINE OF ROOF
EAVES ABOVE
EXISTING
MULTI-PURPOSE
BUILDING
1.10
.80
12.00
12.80
LINE OF ROOF
EAVES ABOVE
6.00
6.00
.80
cu.m.
34.80
802
Excavation
cu.m.
46.25
900
Reinforced Concrete
cu.m.
54.14
1014
sq.m.
543.37
1032
Painting Works
sq.m.
396.00
SPL - 1
sq.m.
32.40
SPL - 2
sq.m.
356.71
SPL - 3
Electric Works
L.S
All
SPL - 4
Mobilization / Demobilization
L.S
All
SPL - 5
L.S
All
SPL - 6
Project Billboard
ea.
2.00
SPL - 7
Main Scoreboard
set
1.00
SPL - 8
set
2.00
SPL - 9
L.S
All
1. Steel
2E+8MPa
2. Concrete
3. Reinforcing Concrete
2E+5MPa
Fy
Ft
f'c
fy
248 MPa
124 MPa
21 MPa
276 MPa
1100 Pa
100 Pa
100 Pa
100 Pa
Pa
24.5 kN/ m^3
LIVE LOAD:
1. Floor
2. Roof
EARTH
4.10
6.00
0 Pa
1000 Pa
WIND LOAD:
1. Velocity
EARTH
EARTH
LINE OF ROOF
EAVES ABOVE
1. Total load
1.20
UP
.40
Zone II
200 kPa
SEISMIC LOAD:
.40
1.20
801
DEAD LOAD:
R1
EDGE OF EXISTING
BASKETBALL COURT
SLAB
3.00
MATERIALS
UP
EXISTING
DOORWAY
mo.
Temporary Facilities
1.20
BASKETBALL RING
POST TO BE REMOVED &
RELOCATED
Qty.
DESIGN CRITERIA:
1.93
EXISTING PLANTERS
.40
1.20
.20
STAGE
UNIT
1875 kN
2.2
1.8
.60
2.95
2.93
.26
2.08
2.25
.93
2.68
2.68
2.68
2.68
ALL STRUCTURAL DESIGNS, ANALYSES, COMPUTATIONS AND SPECIFICATIONS SHALL CONFORM AND BE IN
ACCORDANCE WITH THE FOLLOWING BOOKS / CODES.
1.20
6.30
4.30
12.08
22.68
A
A-2
F L O O R
SCALE
P L A N
1:100
M.
NOTE:
SHEET CONTENT:
DESIGNED BY:
BATANGAS
FLOOR PLAN
SUMMARY OF QUANTITIES
SUBMITTED BY:
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
A-2
2 8
12.00
5.25
5.25
.60
BASKETBALL RING
POST TO BE REMOVED &
RELOCATED
3.00
2.75
4.90
5.50
DOWNSPOUT W/
METAL STRAP @
1.33 M.O.C.
1.20
BOTTOM LEVEL OF
ROOF SIDELINE
GA. 26 PREPAINTED LONG SPAN
RIB-TYPE ROOFING SHEET SIDEWALL
4.90
5.25
2.40
.60 .60
3.00
2.40
BOTTOM LEVEL OF
ROOF SIDELINE
5.50
5.25
TOP LEVEL
OF ROOF
1.70
.60 .60
3.00
TOP LEVEL
OF ROOF
.60
1.20
BCFFL
4 EQ. BAYS @ 5.25
.40m X .40m RC COLUMN
A
A-3
F R O N T
B
A-3
E L E V A T I O N
SCALE
1:100
M.
21.00
5.25
5.25
5.25
1.20
2.40
.60 .60
3.00
3.00
2.40
.60 .60
4.90
5.50
5.50
4.90
DOWNSPOUT W/
METAL STRAP @
1.33 M.O.C.
REGION IV-A
BATANGAS I DISTRICT ENGINEERING OFFICE
NASUGBU,
BATANGAS
BCFFL
4 EQ. BAYS @ 5.25
.40m X .40m RC COLUMN
M.
FRONT ELEVATION
RIGHT SIDE ELEVATION
LEFT SIDE ELEVATION
REAR ELEVATION
DESIGNED BY:
1.20
BOTTOM LEVEL OF
ROOF SIDELINE
BCFFL
SHEET CONTENT:
12.00
2.75
3.00
BASKETBALL RING
POST TO BE REMOVED &
RELOCATED
TOP LEVEL
OF ROOF
BOTTOM LEVEL OF
ROOF SIDELINE
1:100
M.
.60
5.25
SCALE
1:100
TOP LEVEL
OF ROOF
C
A-3
SCALE
1
GA. 26 PREPAINTED LONG SPAN ''DURACURVE''
RIB-TYPE ROOFING SHEET ON 2'' X 6'' X 1.5mm
.60
SUBMITTED BY:
D
A-3
R E A R
E L E V A T I O N
SCALE
RECOMMENDING APPROVAL:
1:100
M.
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
A-3
3 8
21.00
5.25
5.25
5.25
5.25
1.50
1.50
.40
C1/F1
TB
C1/F1
TB
C1/F1
TB
C1/F1a
.40
.40
TB
1.50
1.50
BOTH WAYS
TB
BOTH WAYS
TB
12.00
.40
C1/F1a
C1/F1a
TB
TB
C1/F1
A
S-1
TB
C1/F1
C1/F1
TB
N.G.L.
.20m X .35m
TIE BEAM
C1/F1a
FOUNDATION PLAN
1:100
M.
1.50
SCALE
1.50
N.G.L.
BCFFL
.12
.12
BCFFL
.35
BOTH WAYS
.35
BOTH WAYS
L
1.50
1.50
C1/F1
.35
C1/F1a
B
S-1
1:20
M.
C
S-1
DETAIL
SCALE
OF
TIE
BEAM
1:20
M.
SHEET CONTENT:
BATANGAS
FOUNDATION PLAN
COLUMN & FOOTING DETAIL
DETAIL OF TIE BEAM
DESIGNED BY:
SUBMITTED BY:
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
S-1
4 8
.60
21.00
5.25
5.25
DS
1.20
.60
5.25
DS
DS
SS-1
5.25
DS
SS-1
2"x6"X1.5MM C PURLINS
DS
SS-1
ANCHOR BOLTS ON
20mm THK. BASE PLATE
SS-1
2'' X 6'' X 1.5mm C-PURLINS @ 1.00 M.O.C.
CS-1
CS-1
12.00
CS-1
CS-1
GA. 26 PREPAINTED LONG SPAN
''DURACURVE'' RIB-TYPE ROOFING
SHEET ON 2'' X 6'' X 1.5mm C-PURLINS
.40
.08
.25
.08
10mm THK. STEEL CLAMP FULLY WELDED
TO 20mm BASE PLATE W/ ANCHOR BOLTS
.07
WEB MEMBERS
.40
DS
SS-1
SS-1
DS
DS
A
S-2
SS-1
DS
.07
SS-1
1.20
DS
SCALE
1:100
C
S-2
1:10
M.
PLAN
6.00
6.00
.50
.50
7.37
.40
.40
ANCHOR BOLTS ON
20mm THK. BASE PLATE
.90
7.3
WEB MEMBERS
.60
.60
.60
1.20
1.00
.60
1.00
1
6.5
TO BCFFL (5.50m)
ANCHOR BOLTS ON
20mm THK. BASE PLATE
.27
D
S-2
1:50
D
S-2
M.
B
S-2
SCALE
1:50
REGION IV-A
SCALE
1:10
M.
M.
SHEET CONTENT:
.08
ELEVATION
.25
.40
.08
BOTTOM LEVEL OF
ROOF SIDE WALL
BATANGAS
DESIGNED BY:
SUBMITTED BY:
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
S-2
5 8
1.70
.60
21.00
5.25
5.25
DS
5.25
DS
DS
DS
6mm THK. GUSSET PLATE
4.55
5.25
1.20
DS
.60
SLOPE
12.00
DS
DS
DS
A
S-3
DS
R O O F
SCALE
1.20
1.80
.12
.85
DS
D
S-3
P L A N
1:100
1.20
SLOPE
.45
.60
1:50
M.
GA. 26 PREPAINTED LONG SPAN
''DURACURVE'' RIB-TYPE ROOFING
SHEET ON 2'' X 6'' X 1.5mm C-PURLINS
M.
WEB MEMBERS
5.25
.13
.50
.50
.40
GA. 26 PLAIN
G.I. GUTTER
.40
1:50
M.
4.85
.40
.50
.60
.50
M.
15
.60
.15
.43
1:10
DYNABOLT
.60
.40
SCALE
.30
SCALE
ANCHOR BOLTS ON
20mm THK. BASE PLATE
.60
B
S-3
F
S-3
.30
6mm THK.
GUSSET PLATE
.1
0
.1
6mm THK.
GUSSET PLATE
DOWNSPOUT W/
METAL STRAP @
1.33 M.O.C.
.10
DYNABOLT
5.25
C
S-3
E
S-3
1:50
SHEET CONTENT:
DETAIL OF GUTTER
SCALE
1:20
M.
DESIGNED BY:
BATANGAS
ROOF PLAN
CENTER STRUT
BASKETBALL RING DETAIL
.40m X .40m
COLUMN
.15
SUBMITTED BY:
M.
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
S-3
6 8
.80
.30
.25
GA. 10 CYCLONE WIRE ON 6mm X 25mm
PLATE BAR FRAME CONNECTED ON 50mm
.25
.30
.80
.25
.25
TOP LEVEL
OF FENCE
G.I. PIPE
1.50
G.I. PIPE
TOP LEVEL
OF EXISTING FENCE
1.50
.70
3.70
TAPERED CONCRETE
PEDESTAL
E X I S T I N G
W I R E
M E S H E D
F E N C E
TOP LEVEL
OF PEDESTAL
.50
.70
.30
NGL
2.95
2.93
.26
2.08
A
S-2a
2.25
.93
2.68
2.68
2.68
TB
.20
TB
2.68
.25
.30
1:50
.25
.80
M .
B
S-2a
1:20
M.
.15
1.50
.20
TOP LEVEL
OF EXISTING FENCE
1.50
3.70
TOP LEVEL
OF PEDESTAL
.70
D
S-2a
D E T A I L
SCALE
O F
T I E
1:10
B E A M
M.
NGL
1.90
C
S-2a
2.49
2.50
1:50
M.
SHEET CONTENT:
BATANGAS
DESIGNED BY:
SUBMITTED BY:
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
S-2a
5a 8
.60
21.00
5.25
1.
2.
3.
.60
5.25
5.25
5.25
2.70
1.75
STAGE
STAGE
STAGE
1.20
SW (WEATHER PROOF,
FLUSHED MOUNTED)
4.
1.93
.20
1.20
EXISTING
MULTI-PURPOSE
BUILDING
1.10
12.80
LINE OF ROOF
EAVES ABOVE
6.00
LINE OF ROOF
EAVES ABOVE
UP
.80
12.00
6.00
4.10
EDGE OF EXISTING
BASKETBALL COURT
SLAB
5.
6.
7.
8.
b. CONVENIENCE OUTLET
c. PANEL BOARD
EARTH
6.00
EXISTING
DOORWAY
TRADE/NOMINAL SIZE.
EARTH
EARTH
LINE OF ROOF
EAVES ABOVE
SYMBOL
SW
.60
4.30
5.70
12.08
PANEL BOARD
22.08
C
S-3
1:100
M.
SERVICE ENTRANCE
SINGLE PHASE 2 WIRE
NO. OF OUTLET
CKT
DESCRIPTION
CEE @ 16 Amp.
LIGHTING @ 400W
/ OUTLET
LO
LIGHTING OUTLET
SPARE
2.2
1.7
.60
DESCRIPTION
1.20
UP
1.20
VOLTS
WATTS
AMPHERE
PER
CIRCUIT
AMPHERE
PROTECT
SIZE OF
WIRE
SW
1
MCB
220
3,600
16.36
30
220
16
30
220
16
30
220
LIGHTING OUTLET
30 AT
30 AT
60 AT
30 AT
SPARE
NOTE:
VOLTAGE = 220V AC
MAIN CB = 60 Amp.
SHEET CONTENT:
BATANGAS
DESIGNED BY:
SUBMITTED BY:
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
GINA B. GUINTO
ENGINEER II
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
E-1
7 8
.40
.10
.20
.08 .02
.60
21.00
.02.08
.60
5.25
5.25
5.25
2.70
1.75
.20
1.20
5.25
.10
12.80
12.00
.80
R1
6.00
LINE OF ROOF
EAVES ABOVE
UP
EARTH
6.00
PLAN
.40
.10
.20
UP
1.20
.02.08
1.20
.08 .02
.10
@ .60 M.O.C.
1
2.2
TO STREET
DRAINAGE
.30
22.08
.10
A
P-1
2 % SLOPE
1:100
M.
SECTION
B
P-1
2.
CHANGE IN DIRECTION
1:10
M.
WYES, LONG SWEEP QUARTER BEND, SIXTH - EIGHT OR SIXTEENTH BEND. WHEN THE CHANGE OF
FLOW IS FROM HORIZONTAL TO VERTICAL A SINGLE 81 BEND COMBINATION MAYBE USED ON VERTICAL
STACK AND SHORT QUARTER BENDS MAYBE USED ON WASTE LINE, TEE AND CROSSES MAYBE USED
IN BENT PIPES.
3.
PROHIBITED FITTINGS
NO DOUBLE HUB OR TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL AND WASTE LINES, THE
DRILLINGS AND TAPPING OF HOUSE DRAIN, WASTE OR VENT PIPES OF SADDLE HUB AND BEND PROHIBITED.
4.
5.
6.
NOT LESS THAN 0.30 METER OF AIR SPACE MUST BE LEFT BETWEEN THE TOP OF THE SEWAGE AND THE
UNDER PART OF VAULT ROOF SLAB.
7.
8.
ALL PLUMBING WORKS SHALL BE UNDER THE SUPERVISION OF A LICENSED MASTER PLUMBING AND
LICENSED PLUMBING CONTRACTOR.
SHEET CONTENT:
DESIGNED BY:
BATANGAS
PLUMBING LAYOUT
DETAIL OF CHB LINE CANAL W/
STEEL GRATING
GENERAL NOTES (PLUMBING)
SUBMITTED BY:
RECOMMENDING APPROVAL:
SET NO.
APPROVED BY:
SHEET NO.
HERMINIO C. SIMBOL
ARCHITECT II
CHECKED BY:
FLORENCIA G. CORDOVA
CHIEF, PLANNING & DESIGN SECTION
BENCIO A. AGUZAR
OIC - ASSISTANT DISTRICT ENGINEER
JULIANA D. VERGARA
Officer - in - Charge
P-1
8 8