6KV AC MOTOR TEST REPORT

Usage purpose

Primary
seawater
desalination
High pressure pump B

Installation location

Chemical system

1.Nameplate:
Type

YKK400-2TH

Rated capacity

280KW

Rated voltage

6000V

Rated current

30.3A

Frequency

50HZ

Cos

0.931

Connection Symbol

Ex-factory date

2008.1

Revr/m

2976

Equipment Code

TC80011-1

Manufacturer

SHANGHAI SHANGDIAN ELEC.MACHINERY CO.LTD.

2. Test Polarity:

Applied instrument: MF14 Multimeter operation


3. Test Insulation Resistance:
Windings

Insulation ResistanceG

U V W & G

R15

R60

2.73

8.12

Applied instrument: UT512/2500V


4. Test Resistance:
Windings

U-V

V-W

U-W

Resistance ()

1.778

1.778

1.780

Applied instrument: QJ44 DC. resistance bridge


5. AC Withstand Test:
Windings

Apply Voltage &


Time

U V W

Leakage Current
(mA)

10kV/1min

140

Insulation ResistanceG
Before Test
15S/60S

After Test
15S/60S

2/5.27

2.5/6

Applied instrument:GZF-4KVA/10KV GZF-6K


6.Test Conclusion:
OK
Tested Date
Date:
Tested By:

PT.TRUBA JAYA ENGINEERING

2008.10.06
Date:
Approved By:

Temperature

30

Date:
Witnessed By:

CHENGDA ENG. CORP.OF CHINA


PLN JMK

Page 1 of 1