Sormat Trustfix
version: 3.0.0.5
project data
Constructor
Name ECO
Author
Processor AS
Date 5/16/2014
Comments
CEILING BRACKET AT INSIDE
S-KAH M10
European Technical Approval ETA-08/0173
Diameter 10 mm
Material A4
Effective anchorage depth, h
ef
60 mm
Nominal drill bit diameter, d
0
10 mm
Drill hole depth, h
1
75 mm
Minimum member thickness, h
min
120 mm
Anchor length in concrete, h
nom
68 mm
Installation torque, T
inst
35 Nm
recommended installation torque, T
inst
35 Nm
SORMAT S-KAH 10/20
Available Items:
Art. No. Designation t
fix
Packing units Length
05135 25 piece 20 mm 102 mm SORMAT S-KAH 10/20
05136 25 piece 30 mm 112 mm SORMAT S-KAH 10/30
05138 25 piece 50 mm 132 mm SORMAT S-KAH 10/50
On request 0 piece 100 mm 0 mm SORMAT S-KAH 10/...
Geometry
Anchor plate dimensions
Width 90 mm
Length 150 mm
Distance s
yr,1
45 mm
Distance s
yr,2
45 mm
Centre spacing s
z1
110 mm
Distance s
zr,1
20 mm
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 2 (2/8)
Sormat Trustfix
version: 3.0.0.5
Distance s
zr,2
20 mm
Fixture thickness 14 mm
Thickness of non load-bearing layer, e.g.
plaster etc. 0 mm
Material S235
Clearance hole diameter met: d
f
12.00 mm
relevant edge distances
Edge right 50 mm
Edge bottom 100 mm
Eccentricity
e
y
0 mm
e
z
0 mm
Member thickness 200 mm
Building material class C30/37
non-cracked concrete (verified
compression zone)
Without edge reinforcement
close spacing between bars of surface
reinforcement
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 3 (3/8)
Sormat Trustfix
version: 3.0.0.5
Load
Design values
N
d
0.600 kN
V
yd
1.500 kN
V
zd
0.300 kN
M
xd
0.010 kNm
M
yd
0.010 kNm
M
zd
0.200 kNm
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 4 (4/8)
Sormat Trustfix
version: 3.0.0.5
Anchor bending
The following requirements are met::
- Fixture made of metal
- Fixture rests fully against the anchorage material
- Fixture rests fully against anchor
Design actions (Design values)
Anchor-nr. N
d
V
d
M
d
Anchor 1 2.892 kN 0.676 kN 0.000 Nm
Anchor 2 2.824 kN 0.854 kN 0.000 Nm
Calculation according ETAG 001 (August 2010) - Design Method A
Total capacity due to steel failure
= 2.89 kN Design load values N
h

Sd
= 24.00 kN European Technical Approval N
Rk,s
= 1.40 European Technical Approval
Ms
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 5 (5/8)
Sormat Trustfix
version: 3.0.0.5
= N
Rk,s
/
Ms
European Technical Approval N
Rd,s
= 17.14 kN European Technical Approval
= N
h

Sd
/ N
Rd,s

N
= 16.87 % Total capacity due to tension loading
Total capacity due to pullout
= 2.89 kN Design load values N
h

Sd
= 16.00 kN European Technical Approval N
Rk,p
= 1.80 European Technical Approval
Mp
= 1.10 European Technical Approval
c
= N
Rk,p

c
/
Mp
European Technical Approval N
Rd,p
= 9.78 kN European Technical Approval
= N
h

Sd
/ N
Rd,p

N
= 29.58 % Total capacity due to tension loading
Total capacity due to concrete cone failure
= 5.72 kN N
g

Sd
Design load values
= 10.1 f
ck,cube
h
ef

1.5
N
0

Rk,c
= 28.55 kN ETAG - Annex C (5.2a)
= 406.00 cm A
c,N
ETAG - Annex C 5.2.2.4b
= 324 cm A
0

c,N
ETAG - Annex C 5.2.2.4b
= 0.87
s,N
ETAG - Annex C (5.2c)
= 0.80
re,N
ETAG - Annex C (5.2d)
= 0.99
ec,N
ETAG - Annex C (5.2e)
= 1.00
c
European Technical Approval
= N
0

Rk,c
(A
c,N
/ A
0

c,N
)
s,N

re,N

ec,N

c
N
Rk,c
= 24.63 kN ETAG - Annex C (5.2)
= 1.80
Mc
European Technical Approval
= N
Rk,c
/
Mc
N
Rd,c
= 13.68 kN European Technical Approval
= N
g

Sd
/ N
Rd,c

N
= 41.78 % Total capacity due to tension loading
Total capacity due to splitting
= 5.72 kN Design load values N
g

Sd
= 10.1 f
ck,cube
h
ef

1.5
N
0

Rk,c
= 28.55 kN ETAG - Annex C (5.2a)
= 561.00 cm ETAG - Annex C 5.2.2.4b A
c,N
= 576.00 cm ETAG - Annex C 5.2.2.4b A
0

c,N
= 0.83 ETAG - Annex C (5.2c)
s,N
= 0.80 ETAG - Annex C (5.2d)
re,N
= 0.99 ETAG - Annex C (5.2e)
ec,N
= 1.41 ETAG - Annex C (5.3a)
h,sp
= N
0

Rk,c
(A
c,N
/ A
0

c,N
)
s,N

re,N

ec,N

h,sp
N
Rk,sp
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 6 (6/8)
Sormat Trustfix
version: 3.0.0.5
= 25.66 kN ETAG - Annex C (5.3)
= 1.80 European Technical Approval
Msp
= N
Rk,sp
/
Msp
European Technical Approval N
Rd,sp
= 14.26 kN European Technical Approval
= N
g

Sd
/ N
Rd,sp

N
= 40.10 % Total capacity due to tension loading
Total capacity due to steel failure resulting from shear load
= 0.85 kN Design load values V
h

Sd
= 17.00 kN European Technical Approval V
Rk,s
= 1.50 European Technical Approval
Ms
= V
Rk,s
/
Ms
European Technical Approval V
Rd,s
= 11.33 kN European Technical Approval
= V
h

Sd
/ V
Rd,s

V
= 7.54 % Total capacity due to shear loading
Total capacity due to pryout
= 1.53 kN Design load values V
g

Sd
= 10.1 f
ck,cube
h
ef

1.5
N
0

Rk,c
= 28.55 kN ETAG - Annex C (5.2a)
= 406.00 cm ETAG - Annex C 5.2.2.4b A
c,V
= 324.00 cm ETAG - Annex C 5.2.2.4b A
0

c,V
= 0.87 ETAG - Annex C (5.2c)
s,V
= 0.80 ETAG - Annex C (5.2d)
re,V
= 1.00 European Technical Approval
c
= 24.22 kN ETAG - Annex C 5.2.2.4 N
Rk,c
= 2.00 European Technical Approval k
= k N
Rk,c
V
Rk,cp
= 48.44 kN ETAG - Annex C (5.6)
= 1.50 European Technical Approval
Mc
= V
Rk,cp
/
Mc
V
Rd,cp
= 32.29 kN European Technical Approval
= V
g

Sd
/ V
Rd,cp

V
= 4.74 % Total capacity due to shear loading
Total capacity due to pryout (single anchor)
V
g

Sd
= 0.85 kN Design load values
N
0

Rk,c
= 10.1 f
ck,cube
h
ef

1.5
= 28.55 kN ETAG - Annex C (5.2a)
A
c,V
= 203.00 cm ETAG - Annex C 5.2.2.4b
A
0

c,V
= 324.00 cm ETAG - Annex C 5.2.2.4b

s,V
= 0.87 ETAG - Annex C (5.2c)

re,V
= 0.80 ETAG - Annex C (5.2d)

c
= 1.00 European Technical Approval
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 7 (7/8)
Sormat Trustfix
version: 3.0.0.5
N
Rk,c
= 12.40 kN ETAG - Annex C 5.2.2.4
k = 2.00 European Technical Approval
V
Rk,cp
= k N
Rk,c
= 24.81 kN ETAG - Annex C (5.6)

Mc
= 1.50 European Technical Approval
V
Rd,cp
= V
Rk,cp
/
Mc
European Technical Approval
= 16.54 kN European Technical Approval

V
= V
g

Sd
/ V
Rd,cp
= 5.16 % Total capacity due to shear loading
Total capacity due to concrete edge failure Edge right
= 1.53 kN V
g

Sd
Design load values
= 2.4 d
nom

h
nom

f
ck,cube
c
1

1.5
V
0

Rk,c
= 8.94 kN ETAG - Annex C (5.7a)
= 195.00 cm A
c,V
ETAG - Annex C 5.2.3.4b
= 0.11 ETAG - Annex C (5.7c)
= 0.07 ETAG - Annex C (5.7d)
= 112.50 cm A
0

c,V
ETAG - Annex C (5.7d)
= 1.00
s,V
ETAG - Annex C (5.7e)
= 1.00
h,V
ETAG - Annex C (5.7f)
= 1.02
,V
ETAG - Annex C (5.7g)
= 0.92
ec,V
ETAG - Annex C (5.7h)
= V
0

Rk,c
(A
c,V
/ A
0

c,V
)
s,V

h,V

,V

ec,V
V
Rk,c
= 14.48 kN ETAG - Annex C (5.7)
= 1.50
Mc
European Technical Approval
= V
Rk,c
/
Mc
V
Rd,c
= 9.66 kN European Technical Approval
= V
g

Sd
/ V
Rd,c

V
= 15.84 % Total capacity due to shear loading
Total capacity due to concrete edge failure Edge bottom
= 0.84 kN V
g

Sd
Design load values
= 2.4 d
nom

h
nom

f
ck,cube
c
1

1.5
V
0

Rk,c
= 22.59 kN ETAG - Annex C (5.7a)
= 300.00 cm A
c,V
ETAG - Annex C 5.2.3.4b
= 0.08 ETAG - Annex C (5.7c)
= 0.06 ETAG - Annex C (5.7d)
= 450.00 cm A
0

c,V
ETAG - Annex C (5.7d)
= 0.80
s,V
ETAG - Annex C (5.7e)
= 1.00
h,V
ETAG - Annex C (5.7f)
= 2.50
,V
ETAG - Annex C (5.7g)
= 1.00
ec,V
ETAG - Annex C (5.7h)
= V
0

Rk,c
(A
c,V
/ A
0

c,V
)
s,V

h,V

,V

ec,V
V
Rk,c
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888
Page 8 (8/8)
Sormat Trustfix
version: 3.0.0.5
= 30.12 kN ETAG - Annex C (5.7)
= 1.50
Mc
European Technical Approval
= V
Rk,c
/
Mc
V
Rd,c
= 20.08 kN European Technical Approval
= V
g

Sd
/ V
Rd,c

V
= 4.19 % Total capacity due to shear loading
Total capacity due to interaction of combined tension and shear loads
The selected Anchor is suitable.

N
= 0.42 <= 1

V
= 0.16 <= 1
(
N
)

+ (
V
)

= 0.42
1.5
+ 0.16
1.5
= 0.33 <= 1
Thickness of anchor plate
Because of the missing information about the connected profile, the calculation of the required anchor plate
thickness can not be carried out. It has to be done by the responsible designer.
Annotations
Information regarding calculation
The following documents are referenced for the verification of the anchor load capacity:
- - ETA approval
The following assumptions are made for the calculations:
- - The selected building material class has been verified
- - all of the anchors in a group are of the same type and size
- - The anchor plate remains even during loading
The verification of the local transfer of loads into the anchorage material has been performed. The transfer of
these loads to the rest of the structure must be shown.
The design is based on numerous anchor-specific values. In case of using an alternative anchor or when the data
entered has changed, the calculations have to be redone.
The requirements and regulations of the approval have to be considered.
Additional requirements of the anchor approvals have to be taken into account, especially if the anchors are
loaded dynamically.
File: EDGE ANCHOR.sor
Sormat Oy
Harjutie 5, FIN-21290 Rusko
www.sormat.com
phone: +358 (207) 940 200
fax: +358 (201) 76 - 3888

Potrebbero piacerti anche