Sei sulla pagina 1di 5

LAMPIRAN C

FLOWSHEET

H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
DRAWN BY
HAR
REVISED
8/12/2007
TITLE
PFD CD-VI / CD&GP

1 : KOLOM
2 : STRIPPER
4 : COOLER
5 : CONDENSER
6 : HEAT EXCHANGER
7 : REBOILER
8 : ACCUMULATOR

TEMPERATURE,
O
C
PRESSURE,kg/cm
2

FLOW, M.TON/Day
DRAWDESCRIPTION
Gambar C.12
E-6
D-2
2
7
8
9
10
T - 1
PRIMARY
TOWER
10'X30'
9
14
T - 2
SEC.
TOWER
9'X40'2"
12
11
7
5
4
1 P-1A/B/C
E-3
E-7
D-3
Kerosine
P-2A/B
P-3A/B
Long residue
to HVU
Long residue
to tank
E-2
P 5A/B
Diesel
oil
D-4
P-6
Naphta
E-5
cw
E-4
cw

Gambar C.1 Diagram Alir Proses CD VI
STRIPPING STEAM
LONG RESIDU FROM
STORAGE
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
SERVICE
VACUUM DISTILLATION COLUMN
OFF GAS SEAL DRUM
OFF GAS RELIEF DRUM
STEAM DISENGAGING DRUM
LVGO REFLUK COOLER
LVGO PRODUK COOLER
MVGO EXCHANGER
MVGO REFLUK COOLER
MVGO PRODUK COOLER
HVGO EXCHANGER
HVGO STEAM GENERATOR
HVGO PRODUK COOLER
NO.8 VACUUM RESIDUE EXCHANGER
NO.8 VACUUM RESIDUE EXCHANGER
VACUUM RESIDUE
STEAMGENERATORPRE CONDENSOR
PRIMARY INTERCONDENSER
SECONDARY INTERCONDENSER
AFTER CONDENSER
LSWR RUN DOWN COOLER
VACUUM CHARGE HEATER
LONG RESIDUE CHARGE PUMP
LVGO PUMPS
MVGO PUMPS
HVGO PUMPS
HEATER RECYCLE PUMPS
VACUUM RESIDUE PUMPS
CONDENSATE PUMPS
NO.1 EJECTOR
NO.2 EJEKTOR
NO.3 EJECTOR
ITEM NO.
V-14-001
V-14-002
V-14-003
V-14-006
E-14-001
E-14-002
E-14-003
E-14-004
E-14-005
E-14-006
E-14-007
E-14-008
E-14-009
E-14-010
E-14-011
E-14-012
E-14-013
E-14-014
E-14-015
E-14-016
F-14-001
P-14-001
P-14-002
P-14-003
P-14-004
P-14-005
P-14-006
P-14-007
A-14-001
A-14-002
A-14-003
NOTE
NOTE(1) FOR EJECTOR SYSTEM DESIGN
THE FOLLOWING FLOWRATE
SMALL BE USED :
COMP. MH KG/N
STEAM 18,0 12650
NON. COND. 27,0 840
CONDENSABLE GAS 178,3 2255
TOTAL 31,1 15745
SYMBOL DESCRIBTION UNIT
TEMPERATUR OC
PRESSURE Kg/CM2 G
PRESSURE MMGH
HEAT DUTY 104KCAL/N
DESIGN FLOWRATE BPSD
LINE NO. _
FC FLOWRATE CONTROLLER
FrC FLOWRATIO CONTROLLER
LC LEVEL CONTROLLER
PC PRESSURE CONTROLLER
PDC PRESSURE DIFFERENCE CONTROLLER
TC TEMPERATUR CONTROLLER
LINE NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
STREAM
DESCRIPTIO
N
LONG
RESIDUE
LONG
RESIDUE
LVGO
REFLUK
MVGO
REFLUK
HVGO HOT
REFLUK
HVGO
REFLUK
HEATER
RECYCLE
RESIDUE
QUENCH
OVERHEAD
CONDENSAT
E
LVGO MVGO HVGO RESIDUE
STRIPPING
STEAM
INJECTION
STEAM
MOTIVE
STEAM
WASN OIL
Kl/H @15
o
C
(NM
3
/H)
337,7 178,9 120,8 88,3 103,0 230,6 35,8 35,5 2,5 oil/water 49,0 98,3 98,3 125,6 (6,230) (8,100) 5,245 27,0
KG/H 325,810 162,905 102,200 77,000 95,860 204,000 34,610 34,370
2,030
oil/water
41,730 78,138 81,890 121,410 3,000 6,500 4,245 24,460
SP.GR @
15
o
C (API
GRAFITY)
0,913 0,913 0,854 0,873 0,908 0,908 0,948 0,969 0,819 oil/water 0,834 0,878 0,908 0,969 (18,0) (18,0) (18,0) 0,908
PERTAMINA UP III
PLAJU & SUNGAI
GERONG
DRWby AntON. TK.UNSRI98
APPROVED BY IGB
Vacuum Distillation Diagram
MVGO / HVGO
TO FCCU
LC
1
5
289
327
170
262
105
150
55
415
290
42,03
FOR
PROCESS
F - 14 -
001
1
4
15
350
MP STEAM
FUEL
P - 14 - 005
AB
389
7
278
P - 14 - 006
AB
P - 14 - 004
AB
354
E - 14 - 009
ABCD
9,27 5,72
269
E - 14 - 0010
ABC
8
236
2
180
18,01
E - 14 - 006 AB
PC
236
E - 14 - 003
ABC
P- 14 - 003 AB
5,7
2
1
7
3
PC TC
100
75
85 1
A - 14 - 001 AB A - 14 - 002 AB A - 14 - 003 AB
LC LC
P - 14 - 007 AB
LC
TC
PC
TC
TC PC
V - 14 - 006
E - 14 - 007 AB
PC
170
LC
PC
TC
12
13630
85
AMMONIA
SOLUTION
PC
2440
CW
LCO
RESIDU TO
STORAGE E - 14 - 016
13
18960
E - 14 - 008
4,62
34000
MP STEAM
CW CW
70
1
6
65 7,1
1
1,43
0,86 CW
BY VENDOR
CW
V - 14 -
001
V - 14 -
002
0,6
7
940
82,1
V - 14 -
003
TO ATMOSFIR
OFF GAS
TO F - 14 -
001
9
3,5
55
OVERHEAD
CONDENSATE
TO EXITING
SEWER
OVERHEAD
CONDENSATE
TO SLOP
TANK
E - 14 - 002
E - 14 - 004
7400
10
2,18 1580
5,1
55
5,1
55
5,1
55
5515
LVGO TO
STORAGE
LVGO FOR
ADO BLEND
E - 14 - 005
13630
11
6,4
7
4,6
7
4
207
6
TC
238
BLOW
DOWN
LP
STEAM
BFW
12,
7
18000
3,0
223
MVGO TO
STORAGE
160
4,7
E - 14 - 0011
AB
3,58
211
P- 14 - 002 A
E - 14 - 001
5,3
3
5
405
110
NOTE 17
PC
TC
LC
LC
PC
LC
TC
FC
PC
TC
PC
FC
FC
FC
LC
PC
E - 14 - 015
E - 14 - 014
E - 14 - 013 E - 14 - 012
ABC
Gambar C.13
Gambar C.2 Diagram Alir Proses HVU II
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
H
G
F
E
D
C
B
A
8 7 6 5 4 3 2 1
DRAWN BY
REVISED
28/7/2003
TITLE PFD FCCU
PERTAMINA

DRAWDESCRIPTION

Gambar C.14


Gambar C.3 Diagram Alir Proses RFCCU
Gambar C.4 Diagram Blok Kilang Unit Produksi-1 Sungai Gerong
Off gas