Sei sulla pagina 1di 26

U1.What will you do while Soot Blowing?

MANDATORY
Raise the boiler firing rate
Lower the boiler firing rate ok
Do nothing
2. Steam at 45 t/hr, 60 bar, 510 C. What can be the configuration of astern turbine?
One Curtis of 4 row
2 Curtis of 2 row each ok
6 rows
10 rows
3. For astern running, direction of turbine is reversed by- MANDATORY QUESTION
Admitting steam to a separate turbine connected to same shaft of one of the ahead
turbine
4.During manoeuvring , how is condenser vacuum kept low?
Throttling one or more air ejector valve to reduce air ejector steam
Allowing air from glands ok
Cooling water output
5. During maneuvering , Y is condenser vacuum kept low?
To Prevent distortion of rotor ok
6.During Preheating ,vacuum is kept minimum why?
To Prevent distortion of rotor ok
7.Why is vacuum kept high in condenser (MCQ- MORE THAN ONE)
Steam condenses at lower temperature
Steam flow is directed towards condenser
Max heat is utilised
Steam entering condenser hits condensate at bottom readily
It is apparent that the greater the vacuum obtained, the lower will be the temperature of the
steam. The lower the temperature of the steam in the condenser, the more heat we have
available for conversion into mechanical energy in the engines.
After the steam leaves the exhaust section of the turbine, it enters a condenser, where it is
cooled to its liquid state. The process of condensing the steam creates a vacuum, which then
brings in more steam from the turbine

8.Why is Vacuum condenser used? MANDATORY QUESTION
preventing steam from becoming liquid at the end of turbine
easy air and non condensable gases removal
High Efficiency
Ease of Flow
9.If steam pressure is reduced at inlet of heat exchanger then- MANDATORY QUESTION
Steam temp increases ok
Steam temp reduces
Steam temp remains same

5 What effect does lowering the steam pressure have?
a) The steam temperature rises

b) It has no effect on the temperature but increases the latent heat

c) The steam temperature falls

d) The total heat in steam increases

10.If a h/e stops working what does that signify?
Steam inlet pr is low
Steam inlet pr is equal to or less than steam outlet pressure.
What is the prime cause of stall in heat exchangers?
a) Not enough steam pressure upstream of the control valve

b) The heat exchanger pressure is equal to or less than the backpressure

c) The heat exchanger is undersized

d) The condensate discharges to atmosphere

@ spirax sarco Stall is the reduction or the cessation of condensate flow from the heat exchanger,
and occurs when the pressure in the heat exchanger is equal to, or less than, the total backpressure
imposed on the steam trap.
11.For same inlet pressure of steam, steam flow rate reduces for bigger heat exchanger because-
MANDATORY QUESTION
More surface area for heat exchange
Steam pressure is less and so enthalpy of evaporation is more
V/v inlet is small
Evap. temp. Low
3 For the same heat load on two heat exchangers, why is the mass flowrate of steam
always less in the exchanger with greater heating surface?
a) Because the control valve is smaller

b) The steam pressure is less and so the enthalpy of evaporation is more

c) Because there is more heating area in the oversized exchanger

d) The steam pressure is less and so the steam will be drier

12.What happens to steam pipeline size after pressure reducing valve MANDATORY QUESTION
Reduces since steam volume is less at lesser pressure
Increases since steam volume is more at lesser pressure ok
Remains same

6 The steam pipe after a pressure reducing valve is likely to be:
a) Smaller than the upstream pipe because of the smaller volume of low pressure
steam.

b) The same size as the connection to the plant.

c) Larger than the upstream pipe because the volume of the low pressure steam is
greater.

d) The same size as the upstream pipe because the flowrate through each pipe is the
same.


13.Where do u take bleed steam from? (MTOA) ( MULTIPULE)
HP Turbine + LP Turbine
After LP
Crossover Pipe ok
??????
14.Boiler efficiency is determined by NON MANDATORY
Fuel injected and shaft power
Heat input and power
Steam pressure ....... ok
Steam flow n heat input
15.In BCC system which has feedback from steam pressure, feed forward is provided from
Dump steam
Condensate temp ok
Steam flow rate
16.In single element feed control system if value of steam flow increases, then feed water flow
MANDATORY
Increases ok
No change
Decreases
17.Shrink and swell compensation?
feed fwd
feed back ok
feed fwd and feed back
cannot be compensated
18. Preheating of turbine is done by
Gland steam
condenser
Aux stop valve
Main ahead stop valve
19.Preheating of steam turbine is done slow and prolonged to- (MCQmore than one)
Allow uniform heating of turbine casing
Maintain gap between moving and fixed blades
Reduce differential temperature within casing
Reduce the gap between moving and fixed blades.
20.Why do we open steam v/v slowly? (MCQmore than one) MANDATORY
prevent water hammer
prevent thermal shock doubt
drain condensate
see whether any leaks
21.More reliable method of testing Steam trap
Sight glass
Gauge glass ok
Temperature sensing device
Integrated steam trap sensor or separate chamber got on net
22.Why is steam trap not checked by temp sensing device MANDATORY QUESTION
It is expensive
It is injurious to health ok
Temp of steam changes with pressure
Temp of steam and water is same got on net
23.How many pockets in labyrinth seal of HP and LP Turbine MANDATORY QUESTION
0
2
3
4
24.In gravity type LO system, pressure sensing device is provided to MANDATORY
Ensure enough LO pressure at turbine
Ensure adequate lubrication of turbine
Both A and B
Neither A nor B
25.Advantage of regenerative(there are moving parts) air preheater over recuperative(no moving
parts) air preheater?........
Less bulky
More corrosion resistant ok
Easier to manufacture
Doesnt allow air temp to rise to an abnormal level
26.Why is air preheater used/WHY IS AIR PREHEATED? MTOA MANDATORY QUEST
For better combustion
Boiler Efficiency improves
To prevent thermal shock to furnace ok
To prevent corrosion
27.In Reheat cycle boiler,reheat steam after passing through _____ and ______ is taken back to
boiler and reheated before entering subsequent stages of ahead turbine MANDATORY QUESTION
Superheater ,HP turbine
Economizer, Astern Turbine
Superheater, economizer ok
Superheater, attemperator
28.Why is air heater in uptakes more prone to fire (MCQmore than one) MANDATORY
More oxygen
High temperature
Soot deposit
Proximity to furnace
29.Economizer tube material?
CI gill section ok
Mild Steel/Low Carbon steel
30.Whre is deaerator in a 4 stage feed heating system
At 1
st
stage of discharge of condensate pump
At 2
nd
stage feed heater
At 3
rd
stage ok
At 4
th
stage before entry to boiler
31.Position of Deaerator at top? MANDATORY QUESTION
To provide NPSH required
EFFICIENT USE OFF MACHINERY SPACE/ SO AS TO AVOID AIR POCKETS
STEAM BEING LIGTER FLOWS EASILY TO TOP
TO REMOVE AIR EASILY FROM TOP WITHOUT PASSING THROUGH MACHINERY SPACE
32.How is air removed from condenser? (MCQmore than one)
by cooling down the steam
by using steam in the air ejector
using water as a motive fluid for air ejector
daltons principal of partial pressure (this option may or may not be correct depending upon
what is written in the question)
33.How does air ejector remove air?
Uses steam
Uses cooling water ok
Uses condensate
Improves cooling water flow
34.Function of ejector in a condenser is (MTOA) MANDATORY
To allow steam to pass through to eject air
To allow feed water to pass through to eject air
To allow cooling water to cool
To allow cooling water to pass through to eject air
35.What information is provided on safety valve (MCQmore than one
Lifting pressure
Capacity-flow rate ok
Reseat press
Standard no

1 Which of the following information is not normally included on the safety valve
marking plate?
a) Set pressure

b) Relieving pressure

c) The relevant standard number

d) Information relating to the capacity of the valve

36.Why safety valves are in pair (mandatory) (MCQmore than one)
One is at a higher pressure than the other
One is at a lower pressure than the other
One cant handle all the steam flow
If one fails, other will open
37.When safety vv is overhauled,the end of the spindle is MANDATORY
Rigidly connted to vv lid
is lapped in the recess of the valve seat after grounding the seat by carborundum paste
Ground
Kept detached from vv lid while assembly
38.What type of reduction gear used in turbine? MANDATORY
double helical and double reduction
Single helical ok
39.What type of reduction used in turbine?
Helical ok
40. Flexible coupling in turbine is installed between
turbine and pinion ok
41. If before you take over the watch, you see that there is no water level in the gauge glass,what
will u do?
Inform duty engineer
Secure the fire ok
42.Purpose of economizer?
To increase Main propulsion plant efficiency ok
To reduce the size of boiler

5 What is the purpose of an economiser ?
a) To cool boiler exhaust gases to below dew point

b) To reduce the amount of energy required in the production of steam

c) To enable more steam to be produced from a boiler

d) To utilise heat from boiler exhaust gases


43. Sea water is leaking in condenser then? (MCQmore than one)
Chloride content increases
Vacuum falls
Condenser temp increases
Condenser temp decreases
44.What cant be used as IG on LNG Ships?
IG from boiler ok
Pure Nitrogen from shore
45.Why is steam line occasionally drained before entering the ahead turbine (MCQmore than one)
MANDATORY
To allow steam to come out
Water in steam can damage blades of turbine ok
There is a possibility of water hammering
TO REMOVE ANY DIRT IN LINE

46.Where is steam drain from FO tanks lead to
Observation tank ok
47.Steam line is drained to
Prevent water hammer ok
Remove dirt in line
48. ESRD Boiler(ESD type with reheat) , reheated tube is protected by.gas damper (fill in the blanks)
MANDATORY
During long periods of steaming without the need for reheat, i.e. when running astern or during port
stay, the reheater tube is protected by cooling air from FD fan. Closing of the reheat dampers
automatically opens cooling dampers to admit air above the reheater.
49. How many gauge glasses are required and why at different levels? MANDATORY QUESTION
2,for compensating rolling-pitchng

50. When load decreases, what happens
Fuel decreases at a rate faster than air
51. When the boiler load is increased air is increased first and then fuel and vice versa. Why?
MANDATORY QUESTION
part of feed fwd control
to avoid incomplete combustion
fast response
for stablity
52.Chloride test-what all is added and what is the color?
N/35 of silver nitrate;reddish brown
53.Why is hydrazine handled properly?
Toxic n carcinogenic ok
54.What will happen if hydrazine is added to Low Pressure bOiler?
Reduces oxygen
Breaks down to ammonia
Copper Nitrate
55.What is done in high pressure boiler to remove oxygen? MANDATORY
Hydrazine added ok
Sodium sulphite added
Feed water taken to boiling point in feed heater
All of the above
56. In N/50 H2SO4, strength of conc is MANDATORY QUESTION
1/50 of normality
50 times normality ok
50% of normality
None of above
57.What does N mean in N/50?
Normality ok
58.Purpose of blowdown valve? (MCQmore than one........ not sure about this)
To remove deposits
To empty the boiler ok
Legal requiremen
Fill up the Boiler
59.Blowdown sequence
Open ship side then boiler side ok
Open boiler side then ship side
60.HP turbine is entirely impulse-reaction type MANDATORY QUESTION
True ok
False
61.Steam Bleeding from HP Turbine increases the turbine speed MANDATORY QUESTION
True
False
62.Manoeuvring can be done for more than 2hrs continuously
True
False
63.Does bleeding steam improve efficiency of plant
Yes
No
64.In Reaction turbine, Pr. Drop takes place in the nozzle and in the blades
True
False
65.Are all the sodium salts soluble?
Yes
No
66. HP Turbine gland is not sufficient for LP turbine gland pocket in low load condition?
True
False
67.What is open feed system?
Where u allow air to enter
Where u dont preheat the water
68.What is closed feed system?
Where u dont allow the air to enter ok
Where u preheat the water
69.Meaning of cross compounding? Mandatory question
HP n LP connection using a crossover pipe ok
70.Purpose of attemperator and desuperheater?
Attemperator- maintains the superheat; desuperheater- reduces the temp of superheated steam
71.Disadvantage of regenerative and recuperative air preheater?
Heavy and occupies more space
Less efficiency
Easily corroded
Leak through air seal

72.Flow of cooling water through condenser?
Axial OK
radial
73.Why is steam passed through a strainer before passing PRV? MTOA MANDATORY (MULTIPLE)
To prevent any impurity
To prevent any insoluble impurity OK
To prevent water from passing through

Strainer Strainers arrest any dirt before it is able to pass into the pressure reducing valve
74. In cross compound turbine, set of nozzle at beginning of HP turbine casing is spread over?
NON MANDATORY
An arc of periphery depending on no of sets of nozzles
Entire periphery ok
Abt 180 deg of peripehery
Abt 270 deg of peripehery
75. Gland steam in LP Turbine is required so that
No air leaks in turbine
NO steam leaks out of turbine
Both
None
76. Air is preheated in (MCQ- more than one) MANDATORY QUESTION
Economizer
Air heater OK
Boiler Casing
Air register
77. Joint material between turbine is
Chart paper
Reinforced heat and pressure resistant Metal to metal contact
Reinforced heat resistant
None
78. Gauge glass is blown through for (MTOA)
To ensure cocks are clear ok
Correct level is shown
To Ensure water level is above heating surface
79. Chemicals are added in boiler
As dissolved in small quantity and added to feed water going to the boiler
As dissolved in small quantity and added to boiler in one shot
Tri sodium phosphate and Di sodium hydrogen phosphate with the Na/PO
4
mole ratio of 2.8
added directly to boiler. Hydrazine for removing oxygen from feed water is added to the feed
water.
80. In safety vv overhaul, the bottom side drain is
Kept open
Kept plugged
Connected to a drain pipe
Connected to a drain pipe and pipe is made clear
81. Low Pressure steam is obtained from (MCQ--- more than one)
Steam reducing vv
Low pressure boiler
Steam to steam generator
prv ok
82. 2 Feed vv is placed in series at the inlet of the boiler to-
One is a non return vv which will prevent back flow of water in case the pipe ruptures
Both can be used to control the feed flow ok
Only one is used at a time
83. Cooling water flow through the condenser (MCQmore than one NON MANDATORY
Is just sufficient to take the latent heat away
Is kept as high as possible to cool the condenser ok
Cannot be adjusted as the capactity of the pump is the same
Is adjusted commensurate with the outlet temp of the cooling water
84. Outlet of the steam trap is partially chocked
Capacity of steam trap will reduce ok
Increased differential pressure on steam trap
85. Pressure drop in steam distribution pipeline is due to MANDATORY QUESTION
Frictional loss and heat loss
Pipeline is meant for lesser pressure
Pipeline is meant for higher pressure
Due to distribution
5 Which of the following results in pressure losses in distribution pipework?
a) Sizing the pipes on low pressure instead of high pressure.

b) Frictional resistance within and heat loss from the pipe and fittings.

c) Sizing the pipes on start-up load of the plant.

d) Large steam users.


86. Feed water is preheated to
Less thermal shock while entering furnace
So that bleed steam can be used ok
So that only latent heat is required from the boiler
All of these
87. Steam entering HP turbine is dry and superheated .Why? (mcqmore than one) MANDATORY
It doesnt contain water which is injurious to blades
It contains more enthalpy than saturated steam ok
It doesnt condense readily in steam pipeline
It doesnt condense till it reaches the condenser
88. Steam turbine plant efficiency is increased by
Bleeding steam in stages from turbine ok
89.Protecting material on Economizer tubes is
CI gills ok
90. During warming up, the vacuum is kept at maximum
True
False ok

91. Boiler level control is
Feed back with feed forward signal
Feed forward control with feed back signal ok
Only feed back signal
Only feed forward signal
92. NaOH reacts with : MANDATORY QUESTION
MgCl2
CaSO4
NaCl ok
Na2SO4
93. A combustion control system-air is always kept more than required during load changes :

To avoid incomplete combustion
For more stable operation @spirax sarcoTo ensure complete combustion, an
amount of 'excess air' needs to be provided. This has an effect on boiler efficiency.
For quick response
Part of feed forward system

94. Function of a nozzle is :
to convert enthalpy into kinetic

95. gland packing avoids steam leak at LP side and air leak at HP side of turbine?
True ok
False

96. gland sealing in LP turbine is required why?
no air enters turbine
no steam leaks from turbine ok
neither of them
both

97. Air is Preheated in boiler . why? (mcqmore than one) MANDATORY QUESTION
To improve combustion
To effectively utilise bleed steam ok
To improve thermal efficiency

98. Disadvantage of regenerative type to recuperative type is MANDATORY
Heavy and occupies more space
Less efficiency
Easily corroded ok
Leak through air seal

99. During sea running conditions, direct contact type feed heater normally receives steam from:
(mcqmore than one)
Feed pump exhaust
Bleed steam ok
Pressure reducing v/v
???????

100. why weir is provided in remote water level indicator
Steam is always there in the steam side
water is always there in the steam side
water is always there in the water side ok
Steam is always there in the water side

101. Why phosphate is used in boiler?
To reduce chloride
To reduce alkalinity ok
To precipitate sludge

102. If water level increases in h/e what happens?
Temperature fluctuates and causes corrosion
Increases the pressure of steam ok
None

2 What effects will waterlogging cause in some heat exchangers?
a) None at all

b) It increases the steam pressure in the heat exchanger

c) It can cause swings in the temperature of the heated fluid and corrode the heat
exchanger?

d) It increases the thermal performance


103. Balancing of turbo feed p/p rotating part means?
a) static balancing of rotor
b) dynamic balancing of rotor ok
c) hydraulic balancing the pump end
d) all the above

104. Manoevring vacuum low
a) to have more steam bb
b) control relative expansion in ahead turbine
c) control relative expansion in astern turbine ok
d) to allow less steam to circulate within turbine

105. Hydrazine can be added in low pressure boiler
True
False

106. Formula of Hydrazine
N
2
H
4


Ques 107 During maintenance what happens to the valve lid edge MANDATORY QUESTION
Its lapped and grinded by carbonised plate
Only grinded
Not removed/ fixed on valve seat
When it is assembled valve lid is put first
Ques 108 Steam trap if exit is restricted what will happen?
Differential pressure will increase
Temp increase
Temp of condensate released reduces
Capacity reduces (depending upon options available, mark C or D)

6 What is the effect of increasing backpressure on a bimetallic trap?
a) It reduces the temperature of the condensate released by the trap

b) It allows the trap to be used on a higher steam pressure

c) It increases the differential pressure across the trap

d) The trap must be the same size as the condensate drain line

4 What is the effect of higher backpressure on a steam trap?
a) None whatsoever

b) It reduces the steam pressure in the heat exchanger

c) It reduces the capacity of a steam trap

d) It increases the differential pressure across the steam trap


Ques109 Steam trap fails to operate in open position , what happen to the equipment before it?
Efficiency increases
Efficiency decreases
The steam trap is lost
The Equipment does not work

What effect does a steam trap have when failed in the open position?
a) It will stop the plant from operating

b) It will loose steam and cost money

c) Plant efficiency is maintained

d) Plant efficiency is increased


Ques 110 what type of steam trap used on board?
Thermodynamic type ok

Ques 111 Motive fluid for air ejector in condenser?
Lp steam doubt
HP Steam super heated steam used to avoid erosion of ejector nozzle.
Ques 112 when the feed pump is not supplying water to the boiler then,
It stops
It churns in the casing ok
It recirculates
Ques 113 before taking watch from another watchkeeper you notice that the gauge glass is empty
for the boiler, what do you do?
Blow down the boiler
Increase the feed flow to the boiler ok
Inform the watchkeeper
Secure the fire


Ques 114 Condensate heating from the cargo tanks goes to the
observation tank

Ques 115 Reaction turbine has both fixed and free moving nozzles?
True ok
false


Ques 116 Outer gland pocket in steam turbine what it is used for? MANDATORY
Supply
Exhaust of excess steam
Leak off Gland
Supply and exhaust
There are two pockets in the glands fitted to all the ends of the turbine; the inner
pocket is connected to the gland steam supply and the outer to the exhaust line . The
HP turbine has to further inner pockets due to it having to deal with steam at higher
pressures and hence increased leakage. The innermost pocket simply passes leakage
steam back to the casing a few stages downstream, the next pocket passes the leakage
steam to the HP turbine exhaust.
When the engine is stopped the gland steam make-up supplies the system
requirements. When the engine is in use the flow of steam to the supply pocket of the
inlet end to the HP end reverses and the gland starts to supply the system reducing the
quantity the make-up has to provide. At full power the only gland requiring steam will
be the exhaust end of the LP turbine, the other will be either supplying the system or
supplying themselves sufficiently to not require steam from the system.In this
condition the make-up would be shut and the pressure regulated by the dump opening.

Ques 117 In normal running condition HP gland steam is not sufficient for LP gland. Do we need
external steam?
True
false

Ques 118 what type of turbine is HP turbine?
Impulse reaction
Reaction
Impulse ok
Rateau
Ques 119 How is the speed of turbo alternator governed?
By governing the main steam valve
By governing the aux steam valve
By governor controlling the set of nozzle ok
Something about set of nozzles
Ques 120 why is steam drain from fuel oil heating lead to filter tank? (MTOA) MANDATORY
QUESTION
a) Trap the oil
b) Filter oil and insoluble impurity ok
c) To watch if any oil coming with the condensate
d) To cool the condensate in the condenser

Ques 121 Excess steam from hp gland cannot be supplied to the LP gland during normal running of
the vessel? MANDATORY QUESTION
True ok
False

Q 122 LP Turbine is purely impulse turbine?
True ok
False
Q 123 What type of turbine is feed pump?
Impulse ok
Impulse reaction


Q 124 Material of air heater for low temp. Corrosion? MANDATORY QUESTION
CI Grills
MS fins
Glass or Enamel coating ok
Electroplating of tin


Q 125 Low vacuum during warming up period so that steam flows slowly
True
False ok
Q 126 What happens when bearing runs out of turbine?
Severly damaged
Flow of steam automatically stops
Layers of white metal comes out Layers of white metal comes out (Reeds pg-142, Taylor pg-
65.bearing damaged and being soft comes out.. contact of rotor with bronze sleeve and
this alerts operator but no excessive vibration caused as offset due to bearing clearance
already accounted for during axial alignment of rotor
Q 127 Markings on steam safety vv
Set pressure
Relieving pressure
Capacity/flow rate
Std. no.
Q 128 How does feed water control system regulate the feed inlet and compensate for large
fluctuations of shrink n swell MANDATORY QUESTION
feed fwd ok
feed back
feed fwd and feed back
cannot be compensated
Q 129 Advantage of Rotary cup burner MANDATORY
High tdr
Less maintenance
Cheaper
Less complex
Q 130 Hydrazine can be used in all boilers
True ok
False
Q 131 How is the content of chloride tested in boiler . MANDATORY QUESTION
Titration by H2SO4
Titration by silver nitrate ok
By adding drops of silver nitrate
Q 132 If HP Turbine breaks then what arrangement kept on continuing to reach the port?
Desuperheated steam sent to the l.p turbine, flexible coupling removed ok
Nozzle attached to flange on LP And steam supplied to it.
Q 133 During overhaul of high lift safety valve how is the spindle attached to valve lid
Rigidly so as to allow no movement. ok
By a pin so that there is some movement between them. Found in safety valve survey(Loose
pin is provided to secure valve lid and allow thermal expansion.)

Q 134 Why boiler gauge glass is used in pair ? (MTOA)
a) Legal requirement
b) To compare readings of the two
c) One show different viewing angle from other. gauge glass cover d different area
d) Only one is used at a time

Q 135 What is inner pocket of gland used for
Exhaust
Makeup ok
Both
??????
Q 136 During sea runnin g conditions, direct contact type feed heater normally receives steam from
(MTOA)
a) Feed pump exhaust ok
b) PRV
c) Bleed steam
d) Something ?????
Q 137 Why gauge glass blown peroidcaly?
a)to check level
b)visible range ok
c)1 is standyby
d)to clear cocks.

Q 138 To prevent stm leak and air leak from/to turbines,they r sealed packed.
a)true ok
b)false.

Q 139 Bleed stm used for-
a)heat fo
b)heat feed water
c)stm to stm generator
d)use in evaporating plant for heating.

Q 140 Hardest salt
MgSO4
CaSO4
CaCO3
Q 141 Direct Contact Feed Water comes in direct contact with
1 Chemicals
2 Steam
3 air
4 O2
Q 142 Vac condensor P low
1 condenstae level increases
2 air ejector not working
3 air leak
4 cooling water througput decrease
Q 143 how is condensor Pressure kept low
1 By throttling
2 allowing air via valve from valve connected onto the shell
3 cooling water output
4 via glands on turbine
Q 144 what if steam trap fails open
1. its expensive and steam lost ok
2. eff decreases
3. eff increases
Q 145 Function of outer pocket
a exhaust of excess steam
b supply and exhaust
c supply
Q 146 Function of inner pocket
a exhaust of excess steam
b supply and exhaust
c supply
Open feed system
In the feed water tank we cool deed water reducing the vapour loss
Feed water tank is used for heating feed water
Q 147 shrink and swell compensation

feed back only
feed fwd
feed back control with feed fwd signal

Q 148 feed pump turbine type
impulse
curtis
velcoity compounded
impulse reaction

Q 149 How blades are secured (neither question nor options are clear)
It will not come out by centrifugal force
They dont touch each other
rotational force
All of the above
Q150 HOW WILL YOU ENSURE THAT SCUM IS DIRECT OUT OF BOILER
a.TAKE THE LEVEL OF WATER ABOVE THE SCUM PAN
b.SCUM PAN FLOATS ON WATER
c.SOME AMOUNT OF LOSS OF WATER IS INAVOITABLE
d..FLOW OF SCUMB THROUGH GAUGE GLASS
Q 151 Turbine heating should be in what drn
Uniform
Fwd
Aft
Q 152 If LO pump of turbine fails then what happens
Maneuvering vv closes instantly and alarm is actuated
Maneuvering vv closes gradually after alarm is actuated

Q 153 How is lp steam obtained onboard MTOA
Using a steam to steam generator
Bleed steam
Lp boiler
PRV
Q154 Speed of feed pump always remains constant
True
Flase
Q155 Enthalpy of ecaporation of water
540 Kcal/Kg



2 Which of the following is the most reliable steam trap tester?
a) A sight glass

b) An ultrasonic listening device

c) A temperature monitoring device

d) An integrated steam trap sensor or separate chamber


3 What are the operating principles of an integrated trap sensing system?
a) Ultrasound detection

b) Conductivity and temperature for leaks and blockages respectively

c) Temperature sensing only

d) Pressure sensing


4 Why is it not feasible to rely on temperature sensing for testing steam leaks?
a) Because it is too difficult

b) Temperature sensing devices cost too much


c) Because steam and condensate can co-exist at the same temperature

d) Because saturation temperature varies with steam pressure


5 What are the most convenient steam trap connections to consider for maintenance
purposes?
a) Screwed connections

b) Flanged connections

c) Socket weld connections

d) Universal swivel connections


6 Which of the following statements is true?
a) Ultrasonic trap testers cannot differentiate live steam and flash steam

b) A Spiratec hand held unit cannot indicate a failed closed steam trap

c) Sight glasses cannot differentiate between live steam and flash steam

d) All of the above


Q156. WHILE REVERSING THE TURBINE THE MESHING TEETHS OF GEAR FACE
GETS CHANGED
a.TRUE
b.FALSE

Q157.LP TURBINE IS ENTIRELY IMPULSE-REACTION
a.TRUE
b.FALSE

Q158. HOW TO DETERMINE STEAM PLANT EFFICIENCY
1 FUEL BURNT IN BOILER TO SHAFT POWER OF TURBINE
2.HEAT INPUT TO POWER DEVELOPED
3. HEAT INPUT TO SPPED OF SHIP
4. STEAM PRODUCED TO STEAM ABSORBED

Potrebbero piacerti anche