Sei sulla pagina 1di 66

CALYPSO

Release-Info






Documentation on CALYPSO 5.2 and ServicePack 2

Version 5.2.06
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
Release Info - CALYPSO 5.2

Overview of Contents:
_____________________________________________________________

1 About CALYPSO 5.2 Notes and Familiar Problems

1.1 Important Information
1.2 Installation and System Related Notes
1.3 Notes on the Application

2 Contents and latest changes

3 New Features

4 Installation Instructions

4.1 Installing the CALYPSO Basic DVD
4.2 Installing CALYPSO ServicePacks and Patches
4.3 Data Backup
4.4 Installing the ViScan Drivers
4.5 Installing Software for Metrotom

5 Compatibility

5.1 CMM Validity
5.2 Controllers & Sensors
5.3 PC System
5.4 Software compatibility
5.5 CAD Interfaces

6 Contact
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
1 About CALYPSO 5.2 - Notes and Familiar Problems


Please read the following notes before installing this software!


1.1 Important information


O-Inspect with Rotary Table 5.2 09.05.2011
While creating a measurement plan with an O-Inspect equipped with a rotary table (RT), the RT should be
set to 0, even if the RT functionality is not utilized. This can be achieved by calling RT-Reference (the RT
axis must be valid) or temporarily deactivating the RT altogether:
Pulldown menu > Extras > Settings > CMM > Rotary Table > Activate Rotary Table Functionality to OFF

As a default the RT is deactivated when a new plan is opened (by 'RT activated for this plan in the rotary
table settings page), however, by switching between optical and tactile probing, the internal incorporation of
the RT angle is activated and can lead to incorrect rotated values for features measured.


Circumnavigation with C98 Controllers 5.2 01.03.2011
Circular arc movements (e.g. for outer cylinder features) are always carried out in V-max on Coordinate
Measuring Machines using the C98 controller even if the controller key switch is set to 'MAN' and the CMM
speed should not exceed 70 mm/s. This behaviour is caused by the controller firmware.


Option FlyScan with Sensor type XXT TL2 5.2 01.03.2011
The FlyScan function is no longer supported for application with XXT TL2 sensors.


Stylus data no longer valid when updating CALYPSO 4.0 or older to CALYPSO 5.2 5.0 20.05.2010
Existing stylus and configuration data can no longer be used when updating from older CALYPSO versions.
This concerns CALYPSO versions 4.0 as well as all older versions. If specific data has to be retained, please
contact our Software Hotline.


Stylus System Data Import 5.0 20.05.2010
Styli data exported with version 4.4.04.xx from systems with Zeiss or Renishaw index head (e.g. RDS, DSE,
MIH, PH9 and PH10) may not be imported into newer versions! The useability of imported styli when used on
a CMM is different than usage in simulation mode (without CMM). For use on a CMM re-qualification is
required, in simulation the styli can be used without re-qualifying.


ViScan Scanning unknown Contour 5.0 20.05.2010
With version 5.2 the scanning direction of the optical scanning of unknown contours has been changed. If
necessary existing measurement plans must be adjusted.





CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
ViScan Important Note for all users of F25, O-Inspect and CMMs equipped with ViScan 5.0 20.05.2010
Please take note of the following information regarding existing optical probe data (F25, O-Inspect or ViScan
camera data) created with CALYPSO 4.7.02 or older.

Any existing optical probe data originating from CALYPSO 4.7.02 or older must be deleted before using
Release 5.2. The required camera data must be re-qualified with Release 5.2.

Trying to switch to older camera data with CALYPSO 5.2 will be denied and can result in output of various
error messages.





Shaft Radius of the Reference Sphere 5.0 20.05.2010
The Shaft Radius of the Reference Sphere on the 'Reference sphere management' page must be set to a
value large enough to cover all of the stylus diameters in use:


In order to prevent collision during probe qualification the 'Shaft Radius' setting must be
increased to a value that sufficiently takes into consideration the largest stylus radius in
use (see D2 for the red sphere illustrated).

However, increasing the radius will also reduce the amount of possible angular positions
for qualification (RDS,DSE etc.). A workaround to this situation is achieved by saving
multiple copies of one and the same reference sphere with a varying shaft radius and
selecting the sphere according to the requirements for probe qualification.


RCCAA 5.0 20.05.2010
RCCAA qualified stylus systems must not and need not be re-qualified using the list qualification method.


Sphere Coverage Angle for qualification of passive sensors 5.0 20.05.2010
The Sphere Coverage angle for a full qualification of passive sensors (XXT, SP25) is limited to a minimum of
180, values lower than 180 are ignored. In order to qualify smaller styli a reference sphere with a smaller
diameter (e.g. a stylus of which the radius is known) is required. Following a full qualification it is possible to
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
re-qualify a stylus using the regular reference sphere. For this a lower sphere coverage angle may be
selected and a 6-point qualification is performed.


Interruption of VAST-XXT CNC-Qualification 4.10 17.11.2009
Interrupting a CNC-qualification of a VAST-XXT, will result in undefined probe data! In this case the stylus
must be re-qualified manually completely before using it for measurement or re-running the CNC-
qualification. Please use 'Qualify passive stylus, the selection 'Geometry Re-qualification is not sufficient.



Special characters in Stylus System Names 4.10 17.11.2009
Special characters must not be used in stylus names and stylus system names! Under no circumstances
may apostrophes (' ') or quotation marks (" ") be used in names for styli or stylus systems nor may these
names begin with a special character (e.g. ) or end with a dot! Underscores ('_') may be used as
separators.


ViScan Upgrade 4.10 17.11.2009
After upgrading from older versions to CALYPSO 4.10 or higher the ViScan sensor must be re-qualified
using the chrome template and the reference sphere after installing! LN_653.


ViScan Manual CNC Mode 4.10 17.11.2009
After focussing during manual CNC-runs the optical probing method must be manually re-selected.


ViScan - Grafics Adapters 4.10 17.11.2009
The Grafics adapters ATI FireGL 8800 and NVIDIA Quadro FX1100 are not compatible with CALYPSO in
combination with the ViScan sensor as from version 5.0. The camera image is not displayed correctly in the
graphics window.


.pdf Output Merge Function
GhostScript is required for merging .pdf results, version 8.56 or newer is required for error free application.


Automatic configuration of temperature sensors
You have to reconnect CALYPSO with the controller after adding or removing a temperature sensor, if
automatic configuration is activated in the C99 controller.




Back to overview



CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
1.2 Installation and System Related Notes


Metrology Academy Login Up to Date Info on Metrology Software under Windows 5.2 05.05.2011
Get the latest information regarding Zeiss metrology software on Windows systems here:

http://academy.imt.zeiss.de

With a login and a password you can access 'Software Knowledge' und 'Windows Tips' for the latest tips and
tricks.


Microsoft SQL Server required 5.2 05.05.2011
For running the application the Microsoft SQL Server is needed. The setup routine checks the prerequisites
of your operating system.












Change to
German
language
1. Follow the instructions step
by step.

















3. Press OK.
Press Button for
detailed
information
2. SQL Server check dialog
will be shown.



CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011










Press Button for
detailed
information
4. Press OK.




In case of failure, please contact your IT administrator in order to enable the required
prerequisites.

Locally installed safety systems (firewall and/or intrusion prevention systems) can prevent access to the SQL
server which is installed automatically as a prerequisite of CALYPSO 5.2. In such a case the setup will be
cancelled. To adjust the configuration of your locally used firewall system please contact your IT department.
The communication between the Microsoft Installer (msiexec.exe) and the SQL server (sqlserver.exe)
processes must be assured.

The setup of the SQL server contains the package 'MSXML 6. On some systems the package 'MSXML 6
Service Pack 2' is already installed. This package can be incompatible with the package 'MSXML 6'. If the
SQL server setup is aborted during the installation of the 'MSXML 6' package 'MSXML 6 Service Pack 2'
must be uninstalled first.


.NET Framework 1.1 omitted 5.2 05.05.2011
Microsoft .NET Framework 1.1 is no longer required with CALYPSO 5.2.


ViScan - Windows 7 Compatibility 5.0 20.05.2010
The ViScan Sensor can only be used with Windows 7 in combination with a suitable Framegrabber card
(32bit only). Please refer to chapter 3.4.


64bit Windows System restrictions 5.0 20.05.2010
Operation of the ViScan Sensor is only permissible with 32bit Windows systems!
Operation of the LineScan Sensor is only permissible with 32bit Windows systems!
Operation via HP-IB interface is only permissible with 32bit Windows systems!


Windows 7 - Aero Mode 5.0 20.05.2010
Use of the Aero Mode with installations on Windows 7 systems may cause malfunction of the landscape view
of the graphics window in the custom printout. This can be corrected temporarily by switching off the Aero
Mode. Teleservice/Netviewer application can also be impaired by having Aero Mode active.


Back to overview

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
Windows 7 - Setting Properties for Network Cards
In Windows 7, the NIC Power Management must be set so that the operating system cannot switch off
Network Cards or USB Hubs. To do this the following setting must be made in the Device Manager for the
network cards and USB-Hubs in use:






The 'Allow the computer to turn off this device to save power' box must not be checked.

Recommendation: In addition, set the power mode to 'Never' and the performance to 'High Performance' in
the system power management.
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

Windows 7 - Warning Message during Installation
After installing CALYPSO (successfully) on a Windows 7 system the following warning message might pop
up:




The message is confusing and does not relate to an unsuccessful install. It is caused by the outdated install
assistant tool. A newer version of the install assistant tool is not available.

The warning can be suppressed by executing the install in compatibility mode:




CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
By right clicking the .exe select 'Properties' and set the compatibility mode for Windows XP (ServicePack 2).
Activate by clicking OK:



Windows will 'remember' this setting and further installs will be carried out without the warning message.


Windows 7/64-Bit - Graphics drivers for NVIDIA FX1800
A modification must be made to the driver 266.45 when in use with the graphics adapter NV FX1800 on
Windows 7/64-Bit systems. The 3D setting must be changed to 'Autodesk Motion Builder compatible' to
prevent slow reaction when rotating or moving CAD models.







Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

Windows 7 - Regional Settings

Should your CAD view display incomplete or inaccurate circles:



Open Windows 'Regions and Languages' in 'System control' and select 'Further settings', then replace the
decimal comma by a decimal point or vice versa.



Back to overview






CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

Windows System Control Show window contents while dragging
In order to optimize the screen settings for CALYPSO the setting 'Show window contents while dragging'
should be deactivated. For Windows XP right click on the destop, select Properties and then select 'Effects'
and for Windows 7 adjust the setting in Advanced system settings/Visual effects:



Manipulation of Installed Files and Folders
Installed CALYPSO files must not be manipulated! By renaming or removing files that are installed in the
CALYPSO folder (including installed user data!), you can cause malfunction of your application. By doing so
the Windows Installer autorepair function might be launched unsuccessfully. Inserting program files manually
(via Windows Explorer) can also cause faulty operation.


Back to overview

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

1.3 Notes on the Application


Device Administration
Please ensure that all CMM connections are closed (by closing traffic light windows) before removing a
device from the 'Measuring-Systems' page under 'Extras', 'Workroom', 'CMM'.


Calculating the alignment
When calculating an alignment, the evaluation setting ISO 5459 is not taken into consideration if the
compatibility mode 'Calculate Alignment as Base Alignment' is set to 'On'.


Importing dimension tolerances from ProE
Importing data from ProE is still faulty. Dimension tolerances have no reference and no coordinates. This
problem will be resolved with a CALYPSO ServicePack.


Selecting CMM System Setup for search path to nominal position
This setting is used for using the respective CMM default value for the probing search path. Previously the
value 5 (with **) was displayed as suggestion when selecting the default setting in the editor. However this
was not effective because of a limiting value prompt; the current CMM default value applied. Without
changing the measurement plan, 'CMM System Setup is now displayed as default setting (suggestion), the
performance does not change. If a numerical value is now given as search path, this value is effective even if
it is smaller than the previous limiting value. Too small a value should be avoided.


'Missing Bore' function with probing problems in bores
Difficult probing conditions for individual bores can make finishing CNC measurements difficult and delay
their completion. To avoid this, starting from CALYPSO 4.10, the Missing Bore function can be activated. If
an incorrect probing leads to a cancellation, the bore is recognized as Missing Bore and is omitted with a
renewed CNC Start (with Reset Old Results). If measurement of the bore is to be tried again, then the
actual values for this bore have to be deleted beforehand.


Probing Point Distribution in Slot Features
The distribution of points in slot features changed from CALYPSO 4.6 onwards. Now the same logic as for
circles is used. Should an evaluation of a slot feature not be possible using an odd number of probings, an
additional probing point should be added in order to have an even number of probing points.


Measurement Plan Compatibility using Multiple-Strategy
Application of the multiple-strategy function in new measurement plans created with CALYPSO 4.4.04 or
newer or opening and saving existing measurement plans with CALYPSO 4.4.04 or newer will prevent the
usability of these plans with older CALYPSO versions!



Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

Optimized Articulating Probes
A software enhancement was introduced with CALYPSO 4.4.04 for coordinate measuring machines
equipped with articulating probes (e.g. RDS, DSE, MIH, PH9 and PH10. This enables the usage of all tactile
probes as MasterProbe. The definition of the RDS probe holders was simplified.


myCALYPSO- Language Selection
myCALYPSO can be used in German and in English. When switching from one language to the other, the
following changes must be carried out by the user:
1. Depending on the language selected, the respective 'myCALYPSO.arn' file must be saved under
\CALYPSO\home\om\workarea\myCALYPSO_Macros\autorun\. Use the Windows Explorer to copy the
desired file from the \de subfolder (for German) or the \en subfolder (for English).
2. The language dependent Macro files for macro 121 must be copied to the folder
\CALYPSO\home\om\workarea\myCALYPSO_Macros\inspections\1_macro_al\121\. Use the Windows
Explorer to copy the desired files from the \Macro_121_de subfolder (for German) or the \Macro_121_en
subfolder (for English) to this location.


Measurement Plan Compatibility 'Sphere' with Circular Sections
Measurement plans created with versions older than CALYPSO 4.4 which contain spheres with circular
sections should be checked for the correct start angle in these features!


Distance to Proberack
The preset default value for the distance to the proberack during stylus system changing of XXT and SP25
(for empty probe) was increased from 0 mm to 70 mm with CALYPSO 4.4. All holders which are created new
for XXT and SP25 are now preassigned with 70 mm. This can be adapted subsequently for each holder by
the Master user.



Back to overview

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

Side Styli and List Qualification
With the RDSCAA or DSECAA option, side styli can now also be qualified semi-automatically (except for
XXT sensors!). Please note: List qualification cannot be applied for stylus systems with side styli! However
as a result, on CMMs with articulating probes after a software update to CALYPSO 4.4.04 or newer, all the
styli have to be subsequently completely re-qualified! If you are using the RDSCAA or DSECAA option, it is
imperative that the MasterProbe can be used for the qualification of the fitting position. Passive sensors such
as XXT and SP25 cannot be used for this. To facilitate this, the List Qualification can be used (not for stylus
systems with side styli! ). The procedure is described on the following pages.



1. Open the Probing system qualification window


CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011



2. By clicking on the

icon, the dialog for setting
the RDS axis is opened.













Back to overview








3. Select the Styli list tab:


CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
4. By clicking on the


icon, the message displayed
on the right will appear.

Select Overwrite and click
OK.




5. Close the window for setting the RDS axis with 'Close' and in the ''Probe
system qualification' window start the List Qualification using the caliper icon.


6. In the following dialog, please select List Qualification:



You are prompted to set the index holder to the angle A 0 B 0. You are then prompted to make a probing at
this angle position. This process also takes place if you have not defined a stylus in the angle position 0.
Using this position, the lengths of all the other styli in this stylus system are calculated and automatically
qualified.





Back to overview

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
2 Contents and latest changes




Contents: CALYPSO ServicePack 5.2.06

Default Languages: German, English

Additional Languages: -

Instruction manuals: German, English



Latest changes:

5.2.06 12.09.2011
ServicePack release.

5.2.0405 08.09.2011
12511 XXT with RC-CAA in CNC mode corrected.

5.2.0404 07.09.2011
12613 Bugfix for dynamic Tensor qualification.
12703, 12707 Temperature compensation corrected.
12699 Bugfix for switching to Duplex from workroom.

5.2.0403 29.08.2011
12692, 12685 Bugfixes CAD.
12695 Bugfix for CT measurement.

5.2.0402 17.08.2011
12671, 12688 Bugfixes for curve option.

5.2.0401 15.08.2011
12681 User selection from workroom corrected.
12670 Translation correcetd.
Updated Stylus System Creator.

5.2.0400 22.07.2011
12641 Optimized stylus system selection.

5.2.0306 04.07.2011
Bugfix

5.2.0305 01.07.2011
12595 Stylus data import corrected regarding angle positions.

5.2.0304 22.06.2011
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
12558 Measurement planeditor corrected.
12600 System position display for True Pos corrected.

5.2.0002 10.06.2011
12592 Serviceplan, run enabled.

5.2.0001 31.05.2011
12472, 12352 Bugfixes CAD.
12531 Bugfix Intersection 3d line with cylinder surface.
- Enhancement for DME.




Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
3 New Features

A presentation describing the new functions in CALSPO 5.2 can be found at the end of this document.

3.1 Improved User Interface - Enhanced Layout AF-00264



3.2 Improved User Interface - Simplified introduction for new users AF-00266



CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

3.3 Improved User Interface - Redesigned buttons for CAD window AF-00270




3.4 Readout of external temperature values AF-00280

3.5 Select any workpiece alignment for CAD feature creation AF-00252

3.6 Variable decimal places fr individual characteristics AF-00248

3.7 Circle deviation plot AF-00274

3.8 Export nominals from freeform surface AF-00218

3.9 DME-Server extension AF-00259

3.10 Curve evaluation in section plane AF-00238

3.11 Exploit unused dimensional tolerance for position evaluation with MMC AF-00254

3.12 ASCII export for Stylus System Creator AF-00251

3.13 Probes supported for Lasertracker AF-00256

3.14 Curve distance plot with min-max AF-00239

3.15 Homogeneous coordinates AF-00275

3.16 Profile calculation ASME Y14.5.1M AF-00011

3.17 Curve nominal from actual result in CNC mode AF-00277
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

3.18 Mutual printout for several my CALYPSO -Macros AF-00282

3.19 Improved warning messages in CNC mode (e.g. for undesired lift-off during scanning with XXT)
AF-00271

3.20 LDAP support AF-00208

3.21 Cumulative radial and axial runout AF-00258

3.22 Extended geometry recording AF-00257

3.23 Enhanced Form&Location tolerances from CAD AF-00263

3.24 CFS (Chromatic Focus Sensor) integrated AF-00194






Back to overview

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
4 Installation Instructions

4.1 Installing the CALYPSO Basic DVD


Please refer to all notes regarding the installation in chapter 1.2.

CALYPSO is a single-user application. It cannot be installed on a network and used as a client-server
application.

In order to install CALYPSO you must have full local Administrator rights.

If you are performing an update of an existing CALYPSO installation, the existing installation has to be
uninstalled first. Existing data such as measurement plans, probe data or other CMM-specific data will not be
deleted by uninstalling CALYPSO. However we still recommend creating backup copies of your data at
regular intervals.

Uninstall is performed using the Windows Uninstall function. In Windows, click on 'Start' and select
'CALYPSO' via 'Settings\Control Panel\Add or Remove Programs' and then click on 'Remove'.

When the DVD is inserted, the installation routine usually starts automatically. If this is not the case, use the
Windows Explorer to select 'CALYPSO.exe' on the DVD and start the installation by double-clicking.



Select 'Install' and 'CALYPSO'.

CALYPSO 5.2 will automatically install Windows Installer 4.5, dotNET Framework 3.5 SP1, SQL Server
2008, a PDF printer set and the Zeiss License Manager 1.8.0.0 as prerequisites should these not already be
available on the target system. This usually requires several system reboots and can take a long time
(especially the dotNET Framework).

Simultaneous installation of several CALYPSO versions on one computer is not supported! Error-free
functioning of CALYPSO is only guaranteed it there is just one version installed!


Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
4.2 Installing CALYPSO ServicePacks and Patches


Required program modifications and additions are provided as ServicePacks or Patches. These can arrive
by eMail, on data medium or via download. The procedure is basically the same for all media types.

If you have received a CALYPSO ServicePack or a Patch together with the CALYPSO Basic DVD, the
ServicePack or Patch must be installed after the installation of the Basic DVD.


Prerequisite for the installation of a ServicePack or a Patch is always an existing installation of the
corresponding basic version from a DVD. The version currently installed can be seen in CALYPSO in the
Miscellaneous menu. The version currently installed is also automatically output in the 'Error Report. You
reach this via the 'Extras menu.





How to install a ServicePack:

- First exit CALYPSO if this is running.

- If the ServicePack is on a CD:
The installation routine starts automatically once the CD is inserted. You only need to click once on the
'Install ServicePack button and the installation is carried out in full. If the CD does not start automatically,
open your Windows Explorer and start the CALYPSO _ServicePack.exe by double-clicking.

- If you have received the ServicePack per email (setup.exe):
Copy the setup.exe file to your local hard disk and start the file by double-clicking in the Windows Explorer.

- CALYPSO's system files will be updated the first time the program is called after installation of the
CALYPSO Service Pack. This may take some time. CALYPSO asks you to close, to wait for a moment and
to restart.






For current ServicePacks and Patches concerning CALYPSO visit our website:

http://www.zeiss.com/imt-servicepacks

Please register in order to access the ServicePack download area and you will immediately receive your
personal access code via eMail.



Back to overview

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011

4.3 Data Backup


The installation of specific CMM data is required to guarantee the accuracy of your measuring results.

The CMM-specific data can be saved and then reimported with the 'Save CMM Data and 'Install CMM Data
functions. The data is saved with Save CMM Data and burned on a CD (CMM data CD), which can then be
installed at a later date with Install CMM Data.


The following data is saved:
CAA data
Temperature sensor data
Reference sphere data
Stylus data and stylus holder locations


Saving CMM data:
Prerequisite: CALYPSO is installed correctly and the data is saved on the hard disk.

- Exit CALYPSO.

- In the Windows Start menu, select Start/Programs/Zeiss/Calypso/Save CMM data and follow the
instructions.

- You can enter any folder. After completion of the data backup, the config folder with the saved data is
stored in the specified folder.

- Burn the config folder on a CD ROM.


Installing CMM data:
Prerequisite: Your CMM data is saved on data medium (e.g. CD-ROM).

- Exit CALYPSO.

- In the Windows Start menu, select 'Start/Programs/Zeiss/Calypso/Install CMM data' and follow the
instructions.

- Select the drive of the CMM data CD or the CMM disk.

- Confirm with OK.






Back to overview


CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
4.4 Installing the ViScan Drivers


Hardware drivers are required for ViScan operation, the setup routine described in this chapter installs all of
the required drivers.

Older Framegrabber cards, as shown here, can only be used with Windows XP!




Newer Framegrabber cards, as shown below, can be used either with Windows XP or with Windows 7 (32-
Bit version only!).



The setup is run from the CALYPSO DVD by selecting Drivers and Components and Optical Sensors'.

The ViScan Dongle must be inserted (Type 1 on the parallel port or Type 2 on a USB port).




1. Select Drivers and Components.

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
2. Select Optical Sensors and 'ViScan'.

3. Confirm the following dialog with Install:



4. After Hardlock and IFC the Sapera framework is installed. Confirm with Next:

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011


5. Confirm with Yes:


6. Confirm with Next:



CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
7. Confirm with Next:


8. Select No, I will restart my computer later and confirm with Finish:


CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
9. The driver for the Framegrabber will now be installed. Confirm with Next:


10. Confirm with Yes:



CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
11. Confirm with Next:


12. Select Run-time and confirm with Next:


CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
13. Confirm with Next:



14. Finally the current Framegrabber Firmware will be loaded. Confirm with Automatic:

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011


15. Close the installation with Yes ...


and 'OK':



Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
4.5 Installing Software for Metrotom


Depending upon the operting system in use (32-Bit or 64-Bit) the Metrotom Measuring Module needs to be
installed in addition to the CALYPSO basic software.

Metrotom-CT install sequence:

1. Install CALYPSO basic version.

2. Select 'Drivers and Components' and 'Metrotom Measuring Module' from the menu on the basic DVD and
then decide between the 32-Bit and 64-Bit versions.



3. Finally install CALYPSO ServicePack or Patch if applicable.




Back to overview


CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
5 Compatibility


Please read the Notes and Familiar Problems in Chapter 1 before you use this software.


5.1 CMM Validity


CALYPSO Release 5.2 is intended for application on the following coordinate measuring machines:

Bridge measuring machines: C400, C700
Eclipse
Vista
Contura
Contura G2
Spectrum
Accura
Accura II
Prismo
MC, WMM, PMC, ZMC
UMC
UPMC
CenterMax
GageMax

Horizontal arm measuring machines: Carmet
SMC
SMM
PRO

Large measuring machines: MMZ-T
MMZ-G
MMZ-E
MMZ-B

Special measuring machines: F-25
O-Inspect
METROTOM
DuraMax





Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
5.2 Controllers & Sensors


Permissible combinations of CMM type, controller and firmware version:

Control Firmware Interface Probe
C 90 =7 HPIB Direct: ST, TP2, TP6
Holder PH9 (13*): TP2, TP6
C 98 >=1.80 (*) LAN Direct: VAST, MT 9060
Holder RDS: RST,TP6
Holder DSE(26*): RST,TP2,TP6
C 99 >=10.30 Vista
r ecommended 11.04
>=10.47 Prismo,
Contura
WMM, MC
PMC
r ecommended 11.04
>=11.04 Centermax
>=14.07 Access
>=15.00 Gagemax
UMC, UPMC,
ZMC
>= 16.05 Pro (22*)
Carmet
SMM (23*)
SMC (24*)

>=16.05 , Accura,
Eclipse(11*),
Spectrum(11*)
>= 18.06 Athena, Hera
>= 18.08 Contura G2
>= 20.03,PRISMO MASS
ACCURA MASS

>=21.00 DuraMax
>=20.15 F25
>=20.15 O-Inspect
>=24.0 ACCURA 2
LAN Direct: ST 3, ST, VAST, VAST Gold, XT, DT(3*),
HSS(19*), XXT 18 pin (18*), CFS (29*)
Holder RDS: RST, TP6, TP20 (14*,17*), TP200(14*,
17*; 20*),XXT 5 pin (20*, 21*), SP25(14*), XXT 18 pin
(18*, 20*), Linescan(25*), XDT (27*, 28*)
Holder PH9/PH10 (16*): TP2, TP6, TP20(16*),
TP200(3*, 9*,16*, 20*)
Holder DSE(6*): RST, TP6, TP2
Holder MIH/MH8: TP2, TP6
Holder MSICube(15*): MIH
MZ 1060 RS 232 Holder MIH: TP2, TP6,
MZ 1070,
MA 1070
MZ 2010
RS 232 Holder MIH, MIH-S: TP2, TP6, not tested at present

CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
Notes:

- This matrix assumes that the controls have been configured correctly. In the case of the C99 control, it may happen that the
configuration does not correspond to the sensors used. In this case, the firmware must be at least 14.07 or higher. From this
version onwards, the firmware can mostly recognize the sensors used.
- On column 2 - The software must not be used with firmware releases older than the minimum release stated. Some problems
also could arise with newer intermediate firmware releases which however are older than the current release, see remark at
the bottom of this section. The software was tested with up to date CMMs and current firmware releases. This configuration
will guarantee maximum performance and full functionality.
- Not all stated firmware releases and CMM types (column 2) are compatible with all probe types (column 4)! They are each
referenced independently to this software release. Possible valid combinations of CMM types and probes are documented
and described in separate configuration lists and pricelists.



*) Control units for RDS probe changing systems with older firmware must be upgraded with a new probe changer macro
2*) not for RDS probe change system
3*) Valid for firmware revision 11.04 or higher
4*) Valid for firmware revision 12.02 or higher
5*) Valid for firmware revision 16.02 or higher
6*) Valid for firmware revision 13.03 or higher
9*) Valid for firmware revision 16.03 or higher
11*) Eclipse and Spectrum New deliveries only with firmware >= 18.06. For software updates on CMMs with ST3 without MPS the
firmware need not be changed. Measures to attain compatibility with older firmware versions are being looked into. IMT CMM lab
will inform when available.
12*) For multi-stage probe change system with RDS valid from firmware revision 18.06 or higher
13*) Only with RS232 of evaluation computer
14*) Valid for firmware revision 18.06 or higher
15*) Valid for firmware revision 18.03 or higher
16*) The multi-stage probe change system is not implemented for this holder.
17*) The firmware release 18.06 requires CALYPSO version 4.2 for the probe change system
18*) The XXT 18 pin requires firmware >= 19.05
19*} The HSS probe is supported for firmware 15.04 or higher.
20*) not for horizontalarm CMMs with DSE,CSC.
21*) The 5 pin XXT requires firmware 19.06!
22*) PRO CMMs with firmware older than 17 require attention by a Zeiss service technician.
23*) SMM CMMs with DSE and firmware older than 20 require attention by a Zeiss service technician.
24*) SMC CMMs with firmware older than 20 require attention by a Zeiss service technician.
25*) Linescan is supported for firmware 20.03, WBScan >= 1.11 and MASS wiring
26*) For controller ST87 only.
27*) The XDT sensor requires firmware >= 23.04.
28*) The XDT sensor requires CALYPSO version 5.0
29*) For CFS (Chromatic Focus Sensor) application CALYPSO Version 5.2 & Firmware >= 25 is mandatory.



The following functionality is not supported by the C98 contoller.
Option Navigator
Self centering Scanning
Cylindrical positioning
Dynamic stylus system qualification
Passive sensors are not supported
No CAA in the controller
No optical sensors
Positioning with rounded edges
Automatic depth control for unknown contour measurement

Any other components and combinations are not valid and not compatible!

The software was tested using up-to-date coordinate measuring machines. This configuration
guarantees for full performance and the complete functionality.
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
If you operate older combinations of hardware and firmware this may lead to restrictions (see above
*). Restrictions may result regarding e.g.:



- Measurement
- Scanning functions
- Support of probe changes
- System performance






Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
5.3 PC System


Recommended data systems:
ZEISS High End Workstation: HP Workstation Z800 2x Intel Xeon X5560 2.80 8MB QC CPU-1
1x160 GB SATA 10k SFF, 1x1000GB SATA 7200
24GB RAM DDR3-1333 ECC
NVIDIA Quadro FX3800 1GB
HP Broadcom 5761
PCIe NIC
16x DVD+/-RW, USB Optical Scroll Mouse

ZEISS Entry Workstation: HP Workstation Z200 Intel Core i3-540 3.06 4MB/1333 DC CPU
320 GB SATA 7200
4GB RAM DDR3-1333 ECC
ATI FirePro V3800 512MB
Intel Pro 1000CT GbE NIC
16x DVD+/-RW, USB Optical Scroll Mouse


Minimum system requirements:
The following minimum requirements must be fulfilled for installing and operating CALYPSO 5.2:

PC with 1,6GHz and 2GByte RAM, mouse, printer and data backup facility.

The minimum screen resolution is 1280x1024 pixels. This is the default size for the ' CALYPSO User Desk'
window.

2 network connections must be possible (incl. installed driver):1x for control connection, 1x for customer
network. The TCP/IP network protocol must be installed. The installed graphics card must be installed with
OPEN-GL drivers. At least one of the ZEISS approved graphics cards should be used (NVIDIA QuadroFX
oder ATI Fire GL).


Windows Operating Systems:
The following Windows versions are suitable for running CALYPSO 5.2:

Windows XP with SP 2 32bit
Windows 7 32bit
Windows 7 64bit

CALYPSO 5.2 has been tested successfully on Windows 7 systems. Please note the following restrictions:

- Eagle Eye systems are not supported on Windows 7 systems! Windows XP is required.
- The ViScan Sensor can only be used with Windows 7 in combination with suitable hardware. Please refer
to chapter 4.4.

Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
5.4 Software compatibility


CALYPSO is a single-user application. It is cannot be installed on a network and used as a client-server
application.

If CALYPSO 5.2 is installed in combination with Pi-Web, version 3.8 (or newer) of Pi-Web is required.

Older versions of Pi-Web can cause problems creating PDF-files.


5.5 CAD Interfaces

CALYPSO supports the following CAD Interfaces:


CAD Software Version
Catia 5 20
Catia 4 4.2.4
Pro/ENGINEER Wildfire 5.0
Unigraphics NX7.5
SolidWorks 2011
Inventor 2011
JT Open 8.0 & 8.1
Parasolid 23
IGES 5.3
VDAFS 2.0
STEP AP214






Back to overview
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
CALYPSO Copyright 1996-2011 Carl Zeiss IMT GmbH. All rights reserved. 12.09.2011
6 Contact


If you have questions, ideas or problems regarding CALYPSO, please always use the integrated CALYPSO
Error Report to contact us.

You can call the form for this by selecting 'Error Report' from the 'Extras' menu.

In the 'Comment' field you can add any text to explain your problem.

With the pull down menu in the Error Report, you can save the report (to forward this per email) or print it (for
faxing). Our email address and the fax number can be round in the report together with the respective phone
numbers.


For Germany:

Carl Zeiss IMT
IO-SK Software Support
73446 Oberkochen

Tel.: 07364-20-6336 oder 6337
Fax: 07364-20-4304

eMail: calypsohot@zeiss.de


www.zeiss.de/imt

For USA:

Carl Zeiss IMT Corp.
Software Support
Novi MI 48377

Tel.: 1-800-327-9735
Fax: 248-624-1258 or
763-535-9792
eMail: calypso@zeiss.com


www.zeiss.com


For current ServicePacks concerning CALYPSO visit our website:

http://www.zeiss.com/imt-servicepacks

Please register in order to access the ServicePack download area and you will immediately receive your
personal access code via eMail.





Back to overview

5.2
New functions
Aalen, 11.05.2011
Product management software
11.05.2011 2 Carl Zeiss IMT GmbH, product management software
Agenda
1
2 Functions
Look & Feel Facelift of Graphical User Interface
11.05.2011 3 Carl Zeiss IMT GmbH, product management software
Agenda
11.05.2011 3
1
2 Functions
Look & Feel Facelift of Graphical User Interface
11.05.2011 4 Carl Zeiss IMT GmbH, product management software
Motivation:


Intuitive and easy entrance for new inexperienced users


Support of experienced users for efficient daily work


Improvement of usability with clear structure of the graphical
user interface and easy to understand icons


Modern look & feel for the main CALYPSO and CALIGO
application software


Reduction of visual noise and better user guidance by focused
use of colors.
11.05.2011 4
New in 5.2
Graphical user interface
11.05.2011 5 Carl Zeiss IMT GmbH, product management software
New in 5.2
Graphical user interface
Entrance screen


Direct access to
important functions


Direct access to last
measurement plans


Fast access to settings


Fast access to styles
system settings


Immediate information
which CALYPSO
version is used


Direct start of new
measurement plan
(with or without CAD model)
11.05.2011 5
11.05.2011 6 Carl Zeiss IMT GmbH, product management software
Settings


Use of tabs instead of
action buttons


Work flow from left to right
and from top to bottom


New look of feature and
characteristic lists


CNC start; easy to find
and reach


Rollover effect in list for
better navigation
11.05.2011 6
New in 5.2
Graphical user interface
11.05.2011 7 Carl Zeiss IMT GmbH, product management software
CAD tool bar


Restructuring of the buttons


New icons for intuitive understanding


Faster access to needed function
New philosophy for settings and editor


Tool key for general CALYPSO settings


Gear for measurement plan relevant settings


Pencil for editors
11.05.2011 7
New in 5.2
Graphical user interface
11.05.2011 8 Carl Zeiss IMT GmbH, product management software
Agenda
11.05.2011 8
1
2 Functions
Look & Feel Facelift of Graphical User Interface
11.05.2011 9 Carl Zeiss IMT GmbH, product management software 11.05.2011 9
New in 5.2
Functions
Overview of the new functions
1. Use tolerance bonus for position with LMC/MMC
2. Cumulative run out
3. External temperature value
4. Two results instead of one for the GDT Profile
and GDT Line Profile characteristics
5. Design custom printout for curve distance plot
6. Improved information during measurement run
7. Enhanced support for laser tracker stylus (e.g. T-stylus)
and improved display in CAD window
8. Combination of the custom printouts with myCALYPSO macros possible
11.05.2011 10 Carl Zeiss IMT GmbH, product management software 11.05.2011 10
New in 5.2
Functions
Overview of the new functions
9. Support of LDAP protocol for user authentication
10. Set number of digits for each characteristic
11. New configuration for ViScan (Framegrabber) for improved installation
12. Integration of chromatic focus sensor
13. Importing actual values and nominal values in curve
14. New evaluation 3D curve evaluation in the intersection plane
15. Circle deviation plot
16. Actual values to nominal
17. GD&T from CAD model
18. Generate CAD feature (space point) in any workpiece coordinate system
19. Stylus System Creator export to ASCII
11.05.2011 11 Carl Zeiss IMT GmbH, product management software
1. Use tolerance bonus for position with LMC/MMC


DIN conformant evaluation in addition to mechanical caliber method


In case of MMC/LMC for position the dimensional tolerance not used is used for the
position tolerance


Adjustment in Settings or in
characteristic settings editor


Default setting is mechanical caliber


Calculation result is only different if
dimensional tolerance is exceeded


Used mode can be displayed in the
protocol head
Benefit: MMC bonus limitation to the permissible diameter tolerance for the
toleranced features and for references
11.05.2011 11
New in 5.2
Functions
11.05.2011 12 Carl Zeiss IMT GmbH, product management software
2. Cumulative run out


In addition to single radial and axial run
out the cumulative one now has its own symbol


Calculation is still the same
Benefit: Easier assignment between drawing
and Calypso printout
3. External temperature value


Is needed for automated system


Read from file via PCM
Benefit: Its possible to correct the temperature using
a temperature value read from an external sensor
11.05.2011 12
New in 5.2
Functions
11.05.2011 13 Carl Zeiss IMT GmbH, product management software
4. Two results instead of one for the GDT Profile
and GDT Line Profile characteristics


As specified in the ISO 1101 and ASME Y14.5M-1994 standard
Benefit: Its possible to determine the largest deviations
(two results) inside and outside the part
5. Design custom printout for curve distance plot


Display of inside and outside curve for
curve distance plot (graphics feature)
with indication of the min. and max.
curve distance
11.05.2011 13
New in 5.2
Functions
11.05.2011 14 Carl Zeiss IMT GmbH, product management software
6. Improved information during measurement run


Information shows the user where the error
has occurred and helps him find a solution
(e.g. air scanning)
Benefit: Immediate help if there are errors
in the run
11.05.2011 14
New in 5.2
Functions
11.05.2011 15 Carl Zeiss IMT GmbH, product management software
7. Enhanced support for laser tracker stylus (e.g. T-stylus)


Benefit: Easier handling and improved display in CAD
11.05.2011 15
T-Probe
New in 5.2
Functions
11.05.2011 16 Carl Zeiss IMT GmbH, product management software
8. Combination of the custom printouts with myCALYPSO macros possible
Benefit: Enhanced options for output of measurement printouts
9. Support of LDAP protocol for user authentication


Calypso users must match the users on the LDAP server
Benefits: Less time and effort required in user data management
11.05.2011 16
New in 5.2
Functions
11.05.2011 17 Carl Zeiss IMT GmbH, product management software
10. Set number of digits for each characteristic


New setting to define number of digits for each characteristic in settings editor


Number of digits is also listed in the table file and protocol


Setting is used for nominal/actual calculation therefore a characteristic
with same tolerance and actual value is more likely in tolerance


Two settings: one is a fixed number of digits, the second is one digit more than the
tolerance range
Benefit: Individual calculation and output of single characteristics
Example:
Tolerance range (TR) > 1,0 then 0.1 mm accuracy for rounding
E.g. TR 1.0 actual = 2.143 rounded = 2.1
Tolerance range (TR) >= 0.1 then 0,01 mm accuracy for rounding
E.g. TR 0.01 actual = 1.523 rounded = 1.52
11.05.2011 17
New in 5.2
Functions
11.05.2011 18 Carl Zeiss IMT GmbH, product management software
11. New configuration for ViScan (Framegrabber) for improved installation


New tab Optics - for setting the
work environment


The set configuration can be saved in
the config files, making them
independent during updates
Benefit: Improved installation
and configuration for ViScan
11.05.2011 18
New in 5.2
Functions
11.05.2011 19 Carl Zeiss IMT GmbH, product management software
12. Integration of chromatic focus sensor


Application spectrum enhanced for fast and
accurate (non-contact) distance
measurements


Implementation of steps 1 and 2


Scope of function such as LineScan, i.e.
feature strategy, is defined via Point Set


More user-friendly stylus change has been
designed (new manual stylus change dialog,
during the CNC no prompt for storing the
CFS)


Step 3 with next release
Benefit: Enhanced scope of functions and
stylus change is more user-friendly
11.05.2011 19
New in 5.2
Functions
11.05.2011 20 Carl Zeiss IMT GmbH, product management software
13. Importing actual values and nominal values in curve


New import and export function,
in particular for wear and tear
measurements
Benefit: Simple digitization for creating
new measured/nominal data
14. New evaluation 3D curve
evaluation in the intersection plane


Can also be assigned to Blade
Benefit: Enhanced options for the
evaluation in the intersection plane
11.05.2011 20
New in 5.2
Functions
Nom in plane
(the nominal normals are
shown yellow, the deviations
in the plane red)
Act Nom
(the measured points are shown
green, the vectorial deviations red)
11.05.2011 21 Carl Zeiss IMT GmbH, product management software
15. Circle deviation plot


Evaluation of single points for contour or
circle. Setting for each n point
Benefit: Fast overview for results in a plot
16. Actual values to nominal


Export of single points manually and CNC (VDA, DXF
and text)


Can be set in the feature settings editor


Can also be used via PCM command
Benefit: (among others) Simplified tool correction,
improved wear measurement
11.05.2011 21
New in 5.2
Functions
11.05.2011 22 Carl Zeiss IMT GmbH, product management software
17. GD&T from CAD model


If layer structure is included in the model
it is used in CALYPSO (e.g. CATIA V5)


If it is not available (e.g. ProE, UG) CALYPSO
makes its one layer structure with
TOLERANCES, DATUMES and TEXT
Benefit: Better handling of the GD&T data
11.05.2011 22
New in 5.2
Functions
11.05.2011 23 Carl Zeiss IMT GmbH, product management software
18. Generate CAD feature (space point) in any workpiece coordinate system
11.05.2011 23
New in 5.2
Functions
11.05.2011 24 Carl Zeiss IMT GmbH, product management software
19. Stylus System Creator export to ASCII


All docking points and positions of the stylus sphere center
can now be exported into an ASCII file.
One line will be generated for each position in the coordinate
system of the Stylus System Creator.
Benefit: For this reason the data from the Stylus System Creator can easily
be used to construct the stylus system elements in a CAD system.
11.05.2011 24
New in 5.2
Functions
11.05.2011 25 Carl Zeiss IMT GmbH, product management software 11.05.2011 25 Carl Zeiss IMT, Holger Blum, IS-SP

Potrebbero piacerti anche