1 - TABELAS PARA DIMENSIONAMENTO DE TOMADAS DE USO GERAL (T.U.G.) Obs.: As tabelas a seguir indicam as quantidades mnimas de tomadas.
1.1 - tomadas para COPAS, COZINHAS e REAS DE SERVIO: permetro tomadas de uso geral (T.U.G.) (m) 600W 100W total 3,5 < P 7,0 2 ---- 2 7,0 < P 10,5 3 ---- 3 10,5 < P 14,0 3 1 4 14,0 < P 17,5 3 2 5 17,5 < P 21,0 3 3 6 21,0 < P 24,5 3 4 7 24,5 < P 28,0 3 5 8 28,0 < P 31,5 3 6 9 31,5 < P 35,0 3 7 10 35,0 < P 38,5 3 8 11 38,5 < P 42,5 3 9 12
1.2 - tomadas para BANHEIROS: rea permetro T.U.G. ( m 2 ) ( m ) ( 600W ) qualquer qualquer 1
1.3 - tomadas para SUBSOLOS, VARANDAS, GARAGENS e SOTOS: rea permetro T.U.G. ( m 2 ) ( m ) ( 100W ) qualquer qualquer 1
1.4 - tomadas para DEMAIS CMODOS e DEPENDNCIAS: rea permetro T.U.G. ( m 2 ) (m) ( 100W ) A 6 qualquer 1 5,0 < P 10,0 2 10,0 < P 15,0 3 15,0 < P 20,0 4 A > 6 20,0 < P 25,0 5 25,0 < P 30,0 6 30,0 < P 35,0 7 35,0 < P 40,0 8
2 2 - TABELA PARA DIMENSIONAMENTO DE PONTOS DE LUZ:
carga ( W ) rea ( m 2 ) incandescente (1) fluorescente (2) fluorescente (3)
+ reator A < 10,0 100 40 50 10,0 A < 14,0 160 60 75 14,0 A < 18,0 220 80 100 18,0 A < 22,0 280 100 125 22,0 A < 26,0 340 120 150 26,0 A < 30,0 400 140 175 30,0 A < 34,0 460 160 200 34,0 A < 38,0 520 180 225 (1) - iluminao utilizando lmpadas incandescentes (2) - iluminao utilizando lmpadas fluorescentes (3) - consumo do conjunto lmpada fluorescente e reator
3 - TABELA AUXILIAR PARA DIMENSIONAMENTO:
cmodo ou permetro tomadas ( T.U.G. ) rea lmpadas dependncia ( m ) calculado instalado ( m 2 ) incandesc. fluoresc.
Obs.: * T.U.G. - quantidade de tomadas de uso geral obtida atravs das tabelas do item 4.1; * T.U.E. - quantidade de tomadas de uso especfico, de acordo com a quantidade de aparelhos que requerem tais tomadas (chuveiro, torneira eltrica, forno microondas, ar condicionado etc.) * lmpada fluorescente - indicar a potncia sem o reator