Thank you for choosing Delta DVP-SE. DVP-SE is a 12-point (8DI + 4DO) PLC MPU,
offering various instructions and with 16k steps program memory, able to connect to all
DVP Slim type series extension modules and high-speed extension modules, including
digital I/O (max. 480 I/O points) and analog modules (for A/D, D/A conversion and
temperature measurement). 2 points of 100 kHz and 2 points of 10 kHz high-speed
pulse output satisfy all kinds of applications. DVP-SE is small in size, and can be
installed easily. Users do not have to install any batteries in DVP-SE series PLCs. The
PLC programs and the latched data are stored in the high-speed flash memories.
This instruction sheet only provides introductory information on electrical
specifications, general specifications, installation and wiring. For detailed information
on programming and instructions, please refer to DVP-SE Operation Manual:
Programming. For information about optional peripherals, please see individual
product instruction sheet enclosed with DVP-SE.
This is an OPEN TYPE device and therefore should be installed in an enclosure free
of airborne dust, humidity, electric shock and vibration. The enclosure should prevent
non-maintenance staff from operating the device (e.g. key or specific tools are
required to open the enclosure) in case danger and damage on the device may
occur.
DO NOT connect input AC power supply to any of the I/O terminals; otherwise
serious damage may occur. Check all the wiring again before switching on the power.
is correctly grounded in order to prevent
Make sure the ground terminal
electromagnetic interference. DO NOT touch any terminals when the power is
switched on.
COM1 on this model is the Mini USB communication port. It only can be used to
upload the program from the PLC, download the program to the PLC, and debug the
program temporarily. It is not suitable for the long term monitoring function.

Product Profiles
16

37. 4

3
2

ss

4
5

60

8
13

14

3
10
90

11
D V P -12S E

6
12

15

12
-

[Figure 1]

Unit: mm
1. POWER, RUN, ERROR, COM1 indicator
2. RUN/STOP switch
3. COM1 port (Mini USB)
4. I/O terminals and COM3 comm. port (RS-485)
5. I/O point and COM2, COM3 indicator
6. Ethernet communication port
7. DIN rail clip
8. Mounting hole for extension module

9. Nameplate
10. Right-side extension port
11. DIN rail mounting slot (35mm)
12. Extension unit clip
13. COM2 communication port (RS-485)
14. Mounting rail for extension module
15. DC power input
16. Left-side module connection port

Electrical Specifications
Model
Item

DVP12SE11R

DVP12SE11T

24 VDC (-15 to 20%)


Power supply voltage (with counter-connection protection on the polarity of DC input power)
DVPPS01/PS02: input 100 to 240 VAC, output 24 VDC/1A (PS02: 2A)
Connector
European standard removable terminal block (Pin pitch: 3.5mm)
Operation
Maximum power loss time is 10ms or less.
Inrush current
Max. 7.5 A@24 VDC, I2t = 0.25 A2S
Fuse capacity
2.5 A/30 VDC, Polyswitch
Power consumption
1.8 W
1.5 W
Power protection
With counter-connection protection on the polarity of DC input power
Insulation resistance > 5 M (all I/O point-to-ground: 500 VDC)
-1-

Model

DVP12SE11R

Item

DVP12SE11T

ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge


EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,
Analog & Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
The diameter of grounding wire cannot be smaller than the wire
diameter of terminals L and N (All DVP units should be grounded
directly to the ground pole).
Operation: 0 to 55C (temp.), 50 to 95% (humidity), Pollution degree 2
Storage: -25 to 70C (temp.), 5 to 95% (humidity)
International standards: IEC61131-2, IEC 68-2-6 (TEST
Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
145
135

Noise immunity

Grounding
Operation / storage
Vibration / shock
resistance
Weight (g)

Spec.
Input Points
Items
24 VDC (-15 to 20%) single common port input
Input No.
X0 to X2
X3 to X7
Input type
DC (SINK or SOURCE)
Input current (10%)
24 VDC, 5 mA
Input impedance
4.7 k
Max. frequency
100 kHz
10 kHz
Action
Off On
> 15 VDC
level
On Off
< 5 VDC
Response Off On
< 2.5 s
< 20 s
time
On Off
< 5 s
< 50 s
Filter time
Adjustable within 0 ~ 20ms by D1020 (Default: 10ms)
Spec.
Output Points
Items
Relay
Transistor
Output No.
Y0 to Y3
Y0, Y2
Y1, Y3
Max. frequency
1 Hz
100 kHz
10 kHz
#1
Working voltage
250 VAC, < 30 VDC
5 to 30 VDC
Resistive 1.5 A/1 point (5 A/COM)
0.5 A/1 point (2 A/COM)
#2
Max. load Inductive
15 W (30 VDC)
Lamp
20 WDC/100 WAC
2.5 W (30 VDC)
#3
#3
2 s
20 s
Response Off On
Approx. 10 ms
#3
#3
time
On Off
3 s
30 s
#1: UP, ZP must work with external auxiliary power supply 24 VDC (-15 to +20%), rated
consumption approx. 1mA/point.
#2: Life curves
120 VAC, resistive
30 VDC, inductive (t=7ms)

3,000

2,000

240 VAC, inductive (cos= 0.4)

Operation(X10 3)

1,000

120 VAC, inductive (cos=0.4)

500
300
200
100

30 VDC,
inductive
(t=40ms)

50

Contact

0.1

0.2 0.3

0.5 0.7

2 current(A)

[ Figure 2 ]

#3: Load = 0.5A

I/O Configuration
Model

Point

Input
Type

Point

DVP12SE11R

Output
Type

Relay

DC
(Sink Or Source)

DVP12SE11T

Transistor

I/O Configuration
Relay
Transistor
S/ S
X0
X1
X2
X3
X4
X5
X6
X7

S/ S
X0
X1
X2
X3
X4
X5
X6
X7

C0
Y0
Y1
Y2

Y0
Y1
Y2
Y3

Y3

UP
ZP
SG
C OM3 +
C OM3 -

SG
C OM3+
C OM3 -

-2-

Dimension & Installation


Please install the PLC in an enclosure with sufficient
space around it to allow heat dissipation, See
[Figure 3].
Direct Mounting: Use M4 screw according to the
dimension of the product.
DIN Rail Mounting: When mounting the PLC to
35mm DIN rail, be sure to use the retaining clip to
stop any side-to-side movement of the PLC and
reduce the chance of wires being loose. The retaining clip is at the bottom of the PLC.
To secure the PLC to DIN rail, pull down the clip, place it onto the rail and gently push
it up. To remove the PLC, pull the retaining clip down with a flat screwdriver and gently
remove the PLC from DIN rail.

Wiring
1. Use 22-16AWG (1.5mm) single or multiple core wire
22-16AWG
on I/O wiring terminals. See the figure in the right hand
side for its specification. PLC terminal screws should be
tightened to 1.90 kg-cm (1.65 in-lbs) and please use only
< 1.5mm
60/75C copper conductor.
2. DO NOT wire empty terminal. DO NOT place the I/O signal cable in the same wiring
circuit.
3. DO NOT drop tiny metallic conductor into the PLC while screwing and wiring. Tear
off the sticker on the heat dissipation hole for preventing alien substances from
dropping in to ensure normal heat dissipation of the PLC.

Power Supply
The power input of DVP-SE is DC. When operating DVP-SE please note the following
points:
1. The power is connected to two terminals, 24 VDC and 0 V, and the range of power is
20.4 to 28.8 VDC. If the power voltage is less than 17.5 VDC, the PLC will stop
running, all outputs will go Off, and the ERROR indicator will start to blink
continuously.
2. The power shutdown for less than 10ms will not affect the operation of the PLC.
However, the shutdown time that is too long or the drop of power voltage will stop the
operation of the PLC, and all outputs will go off. When the power returns to normal
status, the PLC will automatically resume the operation. (Please take care of the
latched auxiliary relays and registers inside the PLC when doing the programming).

Safety Wiring
Since DVP-SE is only compatible with DC power supply, Deltas power supply modules
(DVPPS01/DVPPS02) are the suitable power supplies for DVP-SE. We suggest you
install the protection circuit at the power supply terminal to protect DVPPS01 or
DVPPS02. See the figure below.

-3-

AC power supply:100 ~ 240VAC, 50/60Hz

Breaker

Emergency stop: This button cuts off the system power supply when accidental
emergency takes place.

Power indicator

AC power supply load

Power supply circuit protection fuse (2A)

DVPPS01/DVPPS02

DC power supply output: 24 VDC, 500 mA

DVP-PLC (main processing unit)

Digital I/O module

Input Point Wiring


There are 2 types of DC inputs, SINK and SOURCE. (See the example below. For
detailed point configuration, please refer to the specification of each model.)
DC Signal IN SINK mode
Input point loop equivalent circuit

DC Signal IN SOURCE mode


Input point loop equivalent circuit

+24V

+24V

24G

24G

S/S

S/S
X0

X0
X1
X1

[ Figure 6 ]

[ Figure 5 ]

Output Point Wiring


1. DVP-SE has two output modules on it, relay and transistor. Be aware of the
connection of shared terminals when wiring output terminals.
2. Relay output terminals, Y0 to Y3 of relay models use C0 common port. See [Figure
7]. When the output points are enabled, their corresponding indicators on the front
panel will be on.
3. Transistor output terminals, Y0 to Y3 of transistor (NPN) models use UP, ZP
common port. See [Figure 8].

-4-

4. Isolation circuit: The optical coupler is used to isolate signals between the circuit
inside PLC and input modules.
Relay (R) output circuit wiring

DC power supply

Emergency stop: Uses external switch

Fuse: 5 to10A fuse at the shared terminal of output contacts to protect the output circuit
Transient voltage suppressor (SB360 3A 60V): Extends the life span of contact.
1. Diode suppression of DC load: Used when in smaller power [Figure 10a]
2. Diode + Zener suppression of DC load: Used when in larger power and frequent On/Off
[Figure 10b]

Incandescent light (resistive load)


Absorber: Reduces the interference on AC load [Figure 11]
Transistor (T) output circuit wiring

-5-

DC power supply

Emergency stop

Circuit protection fuse

The output of the transistor model is open collector. If Y0/Y1 is set to pulse output, the

output current has to be bigger than 0.1 A to ensure normal operation of the model.
1. Diode suppression: Used when in smaller power [Figure 13a]
2. Diode + Zener suppression: Used when in larger power and frequent On/Off [Figure 13b]

Manually exclusive output: For example, Y2 and Y3 control the forward running and reverse
running of the motor, forming an interlock for the external circuit, together with the PLC
internal program, to ensure safe protection in case of any unexpected errors.

RS-485 Wiring
1 D+ D- SG

D+ D- SG

SG D+ D-

Master node

2
3

Slave node

Figure 14

Terminal resistor

Shielded cable

Note:
1. Terminal resistors are suggested to be connected to master and the last slave with resistor value of
120.
2. To ensure communication quality, please apply double shielded twisted pair cable (20AWG) for wiring.

Ethernet (RJ45) Wiring


Please use the twisted pair CAT-5e to connect the Ethernet RJ45 communication port.
Tx+
N/C
Tx Rx Rx+
N/C
N/C
N/C
Note: The DVP-SE series PLC is equipped with the Auto MDI/MDIX function. It does not need
any jumper wire when it connects to the network device.

Setting the Ethernet


The DVP-SE series PLC contains a built-in Ethernet communication port. Users have to
set the network parameter before the PLC connects to other network devices. The
default parameter setting values are 192.168.1.5 (the IP address) and 255.255.255.0
(the subnet mask). Users can set the parameter by using DCISoft, or by using the PLC
program to write the values into the network control register (CR).

Software: Start the DCIsoft, and connect the PC to the DVP-SE series PLC through
the ehternet cable. Enter Communication Setting page in DCISoft, and choose
Ethernet communication port. Then, click Search to search for the picture
representing the DVP-SE series PLC. After users click the picture twice, the setting
page appears. Finally, enter the related parameters, and click Apply to finish the
setting.

PLC program: Users use the instruction To to write the IP address (CR#88, 89) and
the subnet mask (CR#90, 91). For example, when the IP address is 192.168.1.5,
users write 192.168 (HC0A8) into CR#89, and .1.5 into CR#88 (H105).
Note: When users use the instruction From/To to read the data from the network
control register and write the data into it, the module number is K108.

Precision of the RTC (Second/Month)


Temperature
(C/F)
Maximum error
(Second)

0/32

25/77

55/131

-117

52

-132

Duration in which the RTC is latched: Two weeks

-6-

DVP DVP-SE 12 8 + 4
PLC 16k steps
I/O 480
A/DD/A
100 kHz 10 kHz
PLC


DVP-SE

OPEN TYPE

COM1 Mini USB , PLC ,


1 [Figure 1]mm
1. COM1
2. RUNSTOP

9.
10. I/O

3. COM1 Mini USB

11. DIN 35mm

4. COM3RS-485

12. I/O

5. COM2COM3

13. COM2RS-485

6.

14. I/O

7. DIN

15.

8. I/O

16. I/O

DVP12SE11R

DVPPS01/PS02 100 ~ 240 VAC 24 VDC/1A (PS02: 2A)

3.5mm

10ms

Max. 7.5A@24VDC, I2t = 0.25A2S

2.5 A/30 VDC (Polyswitch)

DVP12SE11T

24 VDC (-15 ~ 20%)

1.8 W

1.5 W

> 5M 500 VDC


ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge

EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,
Analog & Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
-7-

DVP12SE11R

DVP12SE11T

PLC

0 ~ 55C
50 ~ 95%
2

-25 ~ 70C5 ~ 95%


IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)

(g)

145

135

24 VDC-15 ~ 20%

No.

X0 ~ X2

X3 ~ X7

S/S SINK SOURCE

10%

24 VDC5 mA

4.7 k

100 kHz

10 kHz

Off On

> 15 VDC

On Off

< 5 VDC

Off On

< 2.5 s

< 20 s

On Off

< 5 s

< 50 s

D1020 0 ~ 20 ms 10 ms

No.

Y0, Y2

Y1, Y3

1 Hz

100 kHz

10 kHz

5 ~ 30 VDC

250 VAC< 30 VDC

Y0 ~ Y3

#1

1.5 A /1 5 A/COM

#2

15 W30 VDC

20 WDC/100 WAC

2.5 W30 VDC

Off On
On Off

10 ms

0.5 A/1 2 A/COM

2 s

#3

20 s

#3

3 s

#3

30 s

#3

#1UP, ZP 24 VDC-15 ~ +20% 1 mA


#2 [Figure 2]
#3 0.5A

DVP12SE11R
DVP12SE11T

Sink Source

I/O


PLC PLC
3 [Figure 3]
M4
DIN 35mm DIN
-8-

I/O
I/O


1. 22-16AWG (1.5mm) 3
PLC 1.90 kg-cm (1.65 in-lbs) 60/75C
2.
3. PLC


DVP-SE
1. 24VDC 0V 20.4~28.8VDC 17.5VDC
PLC OffERROR LED
2. 10ms PLC
PLC OffPLC
PLC


DVP-SE DC Only
(DVPPS01/DVPPS02) DVP-SE DVPPS01/DVPPS02
4 [Figure 4]
100 ~ 240 VAC, 50/60 Hz

2A

DVPPS01/DVPPS02

24 VDC500 mA

DVP PLC


DC SINK SOURCE
4 [Figure 5] [Figure 6]


1. DVP-SE PLC

2. Y0~Y3 C0 5 [Figure 7]

3. NPN Y0~Y3 UPZP 5 [Figure


8]
4. PLC


5 [Figure 9] ~ [Figure 11]

5~10 A

-9-


1. DC 5 [Figure 10a]
2. DC + Zener On/Off
5 [Figure 10b]


5 [Figure 11]


[Figure 12] ~ [Figure 13b]


1. DC 6 [Figure 13a]
2. DC + Zener On/Off
6 [Figure 13b]

Y2 Y3
PLC

RS-485
6 [ Figure 14]

1. 120
2. 20AWG

(RJ45)
CAT-5e RJ45
Tx+
Tx Rx+

N/C
N/C
Rx-

N/C
N/C

DVP-SE Auto MDI/MDIX


DVP-SE
:192.168.1.5 (IP )255.255.255.0 () DCISoft
PLC (CR)

PLC DCISoft PC DVP-SE


DCISoft Ethernet
DVP-SE
IP

PLC PLC To IP (CR#88, 89)


(CR#90,91) IP :192.168.1.5 CR#89 192.168 (HC0A8) ;
CR88 .1.5 (H105)
DVP-SE From/To (CR)
K108


(C/F)

0/32

25/77

55/131

-117

52

-132

- 10 -

DVP DVP-SE 12 8 + 4
PLC 16k steps
I/O / 480
A/DD/A
100 kHz 10 kHz
PLC


DVP-SE

(OPEN TYPE)

COM1 Mini USB , PLC ,


1 [Figure 1]mm
1. COM1

8.

2. RUNSTOP

9. I/O

3. COM1 (Mini USB)

11. DIN 35mm

4. COM3RS-485

12. I/O

5. COM2COM3

13. COM2RS-485

6.

14. I/O

7. DIN

15.

8. I/O

16. I/O

DVP12SE11R

24VDC (-15 ~ 20%)


DVPPS01/PS02 100 ~ 240 VAC 24 VDC/1 A (PS02: 2 A)

3.5 mm

10ms

Max. 7.5 A@24 VDC, I2t = 0.25A2S

2.5A /30 VDC(Polyswitch)

DVP12SE11T

1.8 W

1.5 W

> 5M 500 VDC


ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge

EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,
Analog & Communication I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m
PLC

- 11 -

DVP12SE11R

DVP12SE11T

0 ~ 55C
50 ~ 95%
2

-25 ~ 70C5 ~ 95%


IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC
68-2-27 (TEST Ea)

(g)

145

135

24 VDC-15 ~ 20%

No.

X0 ~ X2

X3 ~ X7

S/S

10%

24 VDC5 mA

4.7 k

100 kHz

10 kHz

Off On

> 15 VDC

On Off

< 5 VDC

Off On

< 2.5 s

< 20 s

On Off

< 5 s

< 50 s

D1020 0 ~ 20 ms 10 ms

No.

Y0Y2

Y1Y3

1 Hz

100 kHz

10 kHz

LED ON OFF

5 ~ 30 VDC

250 VAC< 30 VDC

Y0 ~ Y3

#1

1.5 A /1 5 A/COM

#2

15 W30 VDC

20WDC/100WAC

2.5 W30 VDC

Off On

10 ms

On Off

0.5 A/1 2 A/COM

2 s

#3

20 s

#3

3 s

#3

30 s

#3

#1UP, ZP 24 VDC-15 ~ +20% 1 mA


#2 [Figure 2]
#3 0.5A

DVP12SE11R
DVP12SE11T


- 12 -

I/O

NPN

PLC PLC
3 [Figure 3]
M4
DIN 35mm DIN
I/O
I/O


1. 22 ~ 16AWG1.5mm 3
PLC 1.90 kg-cm1.65 in-lbs 60/75C
2.
3. PLC


DVP-SE
1. 24 VDC 0 V 20.4 ~ 28.8 VDC 17.5
VDC PLC OffERROR LED
2. 10 ms PLC
PLC OffPLC
PLC


DVP-SE DC Only
(DVPPS01/DVPPS02) DVP-SE DVPPS01/DVPPS02
4 [Figure 4]
100 ~ 240 VAC, 50/60 Hz

2A

DVPPS01/DVPPS02

24 VDC500 mA

DVP PLC


DC DC
4 [Figure 5] [Figure 6]


1. DVP-SE PLC -NPN -PNP

2. Y0 ~ Y3 C0 5 [Figure 7]

3. NPN Y0 ~ Y3 UPZP 5 [Figure


8]
4. PLC


5 [Figure 9] ~ [Figure 11]

5 ~ 10A
- 13 -


1. DC 5 [Figure 10a]
2. DC + Zener On/Off

5 [Figure 10b]


5 [Figure 11]


[Figure 12] ~ [Figure 13b]


1. DC 6 [Figure 13a]
2. DC + Zener On/Off
6 [Figure 13b]

Y2 Y3
PLC

RS-485
6 [Figure 14]

1. 120
2. 20AWG

(RJ45)
CAT-5e RJ45
Tx+
Tx Rx+
N/C

N/C
Rx N/C
N/C

DVP-SE Auto MDI/MDIX


DVP-SE
:192.168.1.5 (IP )255.255.255.0 () DCISoft
PLC (CR)

PLC DCISoft PC DVP-SE


DCISoft Ethernet
DVP-SE
IP

PLC PLC To IP (CR#88, 89)


(CR#90,91) IP :192.168.1.5 CR#89 192.168 (HC0A8) ;
CR88 .1.5 (H105)
DVP-SE From/To (CR)
K108


(C/F)

0/32

25/77

55/131

-117

52

-132

- 14 -

....... TRKE .........

Deltann DVP-SE modelini setiiniz iin teekkrler. DVP- SE PLC rn 12-nokta


(8DI + 4DO) MPU, eitli komutlar ve 16K step program ile tm DVP-S serisi genileme
modlleri (Maksimum 480 adet dijital I/O) ve yksek hzl ilave modllerle (A/D, D/A
dnm ve scaklk lm) ile balanabilir. 2 adet 100 kHz ve 2 adet 10 kHz yksek
hzl pulse k ile birok uygulamann gereksinimlerini karlar. DVP-SE rn kk
boyutlu ve kurulumu kolaydr.
Bu bilgi dkman sadece rnn elektriksel zellikleri, genel fonksiyonlar, kurulumu
ve balants ile ilgili bilgiler salar. Detayl programlama ve DVP-SE uygulama
komutlar ile ilgili ltfen DVP-SE Operation Manual: Programming dkmann
inceleyiniz. Opsiyonel evre birimleri ile ilgili ltfen kutunun iindeki rnle birlikte
gelen bilgi dkmann inceleyiniz. DVP-SE serisi PLClere herhangi bir pil taklmas
gerekmez. PLC programlar ve kalc veriler yksek hzl flash belleklerde saklanr.
Bu rn AIK TP bir PLCdir. PLC rn toz, rutubet, elektrik oku riski ve
titreimden uzak yerlerde muhafaza edilmelidir. Ayrca cihaza yetkili olmayan kiilerin
mdahale etmesini engelleyecek nlemler alnmaldr. (rnein rnn kurulduu
panoya kilit konulmas gibi). Aksi halde kullanclar ve/veya PLC zarar grebilir.
Giri/k terminallerine kesinlikle AC besleme balamaynz. Aksi halde rn zarar
grebilir. Enerji vermeden nce rnn tm balantlarn kontrol ediniz.
Elektromanyetik grlty nlemek iin topraklamann
dzgn yapldna emin
olunuz. Enerjili iken rn terminallerine mdahale etmeyiniz.
COM1 bu model zerinde Mini USB haberleme portudur. Bu port sadece PLCden
program ekmek, PLCye program yklemek ve geici olarak program hata ayklama
iin kullanlabilir. Uzun sreli grntleme ilevi iin uygun deildir.

rn Grn
ngilizce (English) blmnde ekil 1ye [Figure 1] baknz. Birim: mm.
1. POWER, RUN, ERROR, COM1 indikatr
2. RUN/STOP anahtar

9. Etiket
10. Sa-kenar ilave port

3. COM1 port (Mini USB)

11. DIN ray montaj slotu (35mm)

4. I/O terminalleri ve COM3 hab. portu (RS-485)

12. lave nite klipsi

5. I/O nokta ve COM2,COM3 indikatr

13.COM2 haberleme portu (RS-485)

6. Ethernet haberleme portu

14. lave niteler iin montaj ray

7. DIN ray klip

15. DC power girii

8. lave unite iin montaj delii

16. Sol-kenar modl balant portu

Elektriksel zellikler
Model
Madde

DVP12SE11R

DVP12SE11T

Besleme voltaj

24VDC (-15 ~ 20%)


(DC giri besleme ters balant korumas)
DVPPS01/PS02: giri 100 ~ 240 VAC, k 24 VDC/ 1A (PS02: 2A)

Konnektr

Avrupa standart sklebilir terminal blok (Pin ls: 3.5mm)

alma

Maksimum enerji kesintisi zaman 10 ms veya alt.

Sznt Akm

Maksimum 7.5 A@24 VDC, I2t = 0.25A2S

Sigorta Kapasitesi

2.5 A/30 VDC, Polyswitch

G Tketimi

1.8 W

1.5 W

Besleme Koruma

DC giri besleme ters balant korumas

Izolasyon direnci

> 5 M (Tm I/O nokta - ground: 500 VDC)

- 15 -

Model

DVP12SE11R

Madde

DVP12SE11T

ESD (IEC 61131-2, IEC 61000-4-2): 8kV Hava Dearj


EFT (IEC 61131-2, IEC 61000-4-4): G Hatt: 2kV, Dijital I/O: 1kV,
Analog & Haberleme I/O: 1kV
RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

Ses Bakl

Topraklama

Topraklama kablosunun kesiti 24V - 0V terminalleri kablolar


kesitinden kk olmamaldr. (Tm DVP rnleri dorudan ground
ucundan topraklanmaldrlar).

alma/Saklama

alma: 0 ~ 55C (scaklk), 50 ~ 95% (rutubet), Kirlenme derece 2


Saklama: -25 ~ 70C (scaklk), 5 ~ 95% (rutubet)

Titreim/ok direnci

Uluslararas Standartlar: IEC61131-2, IEC 68-2-6 (TEST


Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

Arlk (g)

145

135
Giri Noktas

zellik.
Madde

24 VDC (-15 ~ 20%) tek ortak u girii

Giri No.

X0 ~ X2

Giri Tipi

X3 ~ X7
DC (SINK veya SOURCE)

Giri Akm (10%)

24 VDC, 5 mA

Giri Empedans
impedance

4.7 k

Maksimum frekans
Aktif seviye
Cevap
Zaman

100 kHz

10 kHz

Off On

> 15 VDC

On Off

< 5 VDC

Off On

< 2.5 s

< 20 s

On Off

< 5 s

< 50 s

Filtre zaman

D1020 datasndan 0 ~ 20 ms (Default: 10 ms)


k Noktas

zellik
Madde

Rle

k No.

Y0, Y2

Y1, Y3

1 Hz

100 kHz

10 kHz

Maksimum frekans
alma Voltaj
Maksimum
Yk
Cevap
Zaman

Transistor

Y0 ~ Y3
250 VAC, < 30 VDC
Rezistif

5 ~ 30 VDC

1.5 A /1 nokta (5 A/COM)

#1

0.5 A/1 nokta (2 A/COM)

Endktif

#2

15 W (30 VDC)

Lamba

20 WDC/100 WAC

2.5 W (30 VDC)

Off On

Yaklak 10 ms

On Off

2 s

#3

20 s

#3

3 s

#3

30 s

#3

#1: UP, ZP harici 24 VDC (-15 ~ +20%) g kayna ile alr, g tketimi oran yaklak 1
mA/nokta.
#2: ngilizce (English) blmnde ekil 2ye [Figure 2] baknz.
#3: Yk = 0.5 A.

I/O Konfigurasyon
Model

Giri
Tip

DC
(Sink veya
Source)

DVP12SE11R
DVP12SE11T

Nokta

Nokta

I/O konfigurasyon
Tip

Rle

Transistor

Rle

ngilizce
(English)
blmnde
baknz

ngilizce
(English)
blmnde
baknz

4
Transistor
- 16 -

ller & Kurulum


Ltfen PLCnin kurulumunu yaparken s dalmnn verimli olmas iin evresinde
gerekli boluun brakldna emin olunuz.
Ltfen ngilizce (English) blmnde ekil 3e [Figure 3] baknz.
Dorudan Montaj: rnn llerine gre ltfen M4 vida kullannz.
DIN Ray Montaj: PLC rn 35mm DIN rayna monte edilecei zaman, rnn
hareket ederek kablo balantlarnn zarar grmesini engellemek iin sabitleyici klipsleri
kullannz. Sabitleyici klipsler PLCnin altnda olup, PLCyi DIN rayna sabitlemek iin bu
klipsleri bastrnz. PLCyi yerinden karmak iinse ince tornavida yardm ile nce bu
klipsleri anz ve PLCyi DIN rayndan ekerek kartnz.

Balant
1. PLCnin I/O terminal balantlarn yapmak iin
22-16AWG
22-16AWG (1.5mm) tek damarl veya ok damarl kablo
kullannz. Kablo zellikleri yandaki ekilde gsterildii
gibi olmaldr. PLC terminal vidalar 1.90 kg-cm (1.65
< 1.5mm
in-lbs) orannda sklmal ve sadece bakr iletkenler
kullanlmaldr.
2. Bo terminallere balant yapmaynz ve I/O sinyal kablolar ile power kablolarn
ayr kablo bloundan balaynz.
3. PLC kablo balantlarn yaparken PLCnin iine iletken paracklar drmeyiniz.
Balantlar tamamladktan sonra s dalmn salanabilmesi iin kk cisimlerin
PLCnin iine dmesini engelleyen koruyucu etiketleri kartnz.

G Kayna (Power Supply)


DVP-SE serisi rnlerin besleme girii DCdir. DVP-SE serisi rnleri kullanrken
aadaki uyarlara dikkat ediniz:
1. Besleme, 24 VDC ve 0 V terminallerine balanmal ve besleme voltaj 20.4 ~ 28.8
VDC aralnda olmaldr. Eer besleme voltaj 17.5 VDC altna derse, PLC
almay durdurur, tm klar OFF olur ve ERROR indikatr srekli flash yapar.
2. 10 ms altndaki enerji kesintisi PLCnin almasna etki etmeyecektir. Fakat daha
uzun sureli bir enerji kesintisi veya voltaj dmesi durumunda PLC almas
duracak ve tm klar OFF olacaktr. PLCnin beslemesi normal duruma
dndnde, PLC otomatik olarak normal almasna geri dner.
(PLC programlanaca zaman iindeki kalc rle ve registerlerin kullanmna dikkat
ediniz).

Gvenli Balant
DVP-SE rnleri sadece DC voltaj ile beslenir. DELTAnn g kaynaklar
(DVPPS01/DVPPS02), DVP-SE PLClerin beslemesi iin uygundur. DVPPS01 veya
DVPPS02 rnlerini korumak iin power supply terminallerine koruyucu devre kurulmas
nerilir. ngilizce (English) blmnde ekil 4e [Figure 4] baknz.
AC power supply: 100 ~ 240 VAC, 50/60 Hz Devre kesici
Acil Stop: Acil durumda sistemin enerjisini kesmek iin kullanlr.
Power indikatr

AC power supply yk

Power supply devre koruma sigortas (2A)

DVPPS01/DVPPS02

DC power supply k: 24 VDC, 500 mA

DVP-PLC (Ana ilemci birimi)

Digital I/O modl

Giri Balants
- 17 -

2 eit DC giri vardr, SINK veya SOURCE. ngilizce (English) blmde ekil 5e
[Figure 5] ve ekil 6ya [Figure 6] baknz.

k Balants
1. DVP-SE serisi rnlerde 2 eit k vardr. Rle ve Transistr (NPN/PNP). k
terminal balantlarn yaparken ortak terminallerin kullanmna dikkat ediniz. (COM).
2. Rle k terminalleri, Y0 ~ Y3 rle k modellerde C0 ortak ucunu kullanr.
ngilizce (English) blmde ekil 7ye [Figure 7] baknz. k terminalleri aktif
olduu zaman n panelde klara karlk gelen ilgili indikatrler de ON olur.
3. Transistr k terminalleri (NPN), Y0 ~ Y3 UP, ZP ortak ularn kullanr. ngilizce
(English) blmde ekil 8e [Figure 8] baknz.
4. zolasyon devresi: PLC i devreleri ve giri modlleri arasn izole etmek iin
optokuplr kullanlr.
Rle (R) k devre balants
Balant detay iin ngilizce (English) blmde ekil 9a - ekil 11e [Figure 9] ~
[Figure 11] baknz.
DC power supply

Acil stop: Harici switch kullanr.

Sigorta: k devrelerini korumak iin klarn ortak terminallerinde 5~10A sigorta kullanr.
Yksek gerilim darbe koruyucu (SB360 3A 60V): Kontak mrn uzatmak iin kullanlr.
1. DC yk diyot koruma: Dk power olduu zaman kullanlr. (ngilizce (English) blmde
ekil 10aya [Figure 10a] baknz).
2. DC yk Diyot + Zener koruma: Yksek power veya ok sk On/Off durumlarda kullanlr.
(ngilizce (English) blmde ekil 10bye [Figure 10b] baknz)

Akkor Lamba (resistif yk)


Dalga Emici (Absorber): AC ykteki grlty nlemek iin kullanlr. (ngilizce (English)
blmde ekil 11e [Figure 11] baknz)

Transistr (T) k devre balants


Balant detay iin ngilizce (English) blmde ekil 12 ~ ekil 13bye [Figure 12] ~
[Figure 13] baknz.
DC power supply

Acil stop

Devre koruma sigortas

Transistor kl modeler ak kolektr(open collector) dr. Eer Y0/Y1 pulse k olarak


ayarlandysa, normal alma iin k akm 0.1Aden byk olmaldr.
1. Diyot koruma: Dk power olduu zaman kullanlr. (ngilizce (English) blmde
ekil 13aya [Figure 13a] baknz)
2. Diyot + Zener koruma: Yksek power veya ok sk On/Off durumlarda kullanlr
(ngilizce (English) blmde ekil 13bye [Figure 13b] baknz)

Manual tek k: rnein, Y2 ve Y3 klar motorun ileri ve geri almasn kontrol etsin.
klarn ayn anda almasn ve beklenmeyen hatalar nlemek iin PLC programnda
ve harici devre balantsnda gerekli nlemler alnarak ayn anda sadece tek kn
almas salanabilir.

RS-485 Wiring
ngilizce (English) blmde ekil 14ye [Figure 14] baknz.
Master istasyon

Slave istasyon

Terminal resistor

Ekranl kablo

Not:
1. Terminal resistorun master ve son slave arasnda 120W olacak ekilde balanlmas nerilir.
2. Haberleme kalitesini arttrmak iin, ltfen balantda double shield (ift ekranl) twisted pair
(sarmal iftli) kablo (20AWG) kullannz.

Ethernet (RJ45) Balants


- 18 -

Ethernet RJ-45 haberleme portuna balant iin ltfen sarmal iftli CAT-5e kullann.
Tx+
N/C
Tx Rx Rx+
N/C
N/C
N/C
Not: DVP-SE serisi PLC Auto MDI/MDIX fonksiyonu ile donatlmtr. Bir aa balanrken cross
balantya ihtiya duymaz.

Ethernet Ayar
DVP-SE serisi PLC dahili Ethernet haberleme portu ierir. PLC dier a aygtlarna
balanmadan nce a ayarlarnn yaplmas gerekmektedir. Varsaylan a parametreleri
192.168.1.5 (IP adresi) ve 255.255.255.0 (alt a maskesi) eklindedir. Kullanclar kendi
parametrelerini DCISoft yardm ile veya PLC ladder programndan a kontrol
registerlarna (CR) yazma yaparak ayarlayabilir.

Yazlm: DCIsoft yazlmn balatn ve DVP-SE PLCyi ethernet kablosu aracl ile
PCye balayn. DCIsoft ierisinde Communication Setting sayfasna girin ve
Ethernet haberleme portunu sein. Daha sonra DVP-SE serisi PLC resmini
gsteren simgeyi buldurmak iin Search zerine tklayn. Resim simgesi
bulunduktan sonra zerine ift tkladnzda ayarlar penceresi alacaktr. Son olarak
gerekli parametreleri girdikten sonra ayar ilemini tamamlamak iin Apply butonuna
tklayn.

PLC program: Kullanclar, IP adresi (CR#88, 89) ve Alt A Maskesi (CR#90, 91)
deerlerini yazdrmak iin TO komutunu kullanr. rnein; IP adresi 192.168.1.5 ise
kullanclar 192.168 (HC0A8) deerini CR#89 ierisine ve 1.5 (H0105) deerini
CR#88 ierisine yazmaldr.
Not: Kullanclar FROM/TO komutlarn a kontrol registerlarndan data okumak ve
data yazmak iin kullandnda modl numaras K108 dir.

RTC Doruluu (Saniye/Ay)


Scaklk (C/F)

0/32

25/77

55/131

Maksimum hata
(Saniye)

-117

52

-132

RTC kalc olduu sre: ki hafta

TRKYE

THALATI FRMA:
F.A.S.T. Fabrika Aygtlar Sistem Teknolojisi Ltd.ti.
Fast Plaza Atilla lhan Cad No:53
34750 Ataehir/ STANBUL
T: +90 216 574 9434 F: +90 216 574 1660
E: satis@fastltd.net W: www.fastltd.net

- 19 -

Potrebbero piacerti anche