Sei sulla pagina 1di 1

BHARAT HEAVY ELECTRICALS LIMITED, RUDRAPUR

ch, pbZ,y TEST REQUISITION AND REPORT FOR


DYE-PENETRANT EXAMINATION

P.B. - 1531 P.O No. : 91131 PROJECT : BHUSAWAL T.P.S.


PART-1
From : Quality Control: Narmada Switchgear Pvt. Ltd. Reqn. Ref. : QC / NSPL /09 –10/
: Date :
Component : ENCL.&COND. Item No. :
Qty. : Given below SL. No. :
Drg. No. : Given Below Specification : AA0850131 Rev- 02
W.O. No. : 3088012 Material : Aluminium,
Area of Test : All Welded Area 100% Surface : free from oil, spatter &
Condition burr free.
Customer : BHEL, RUDRAPUR Supplier : N.S.P.L
Welder’s Name : Mr. T.P. Sharma & Mr. Babulal Signature :
Test to be witnessed by : Name :
DETAILS OF EXAMINATION
DYE PENETRANT TEST
Procedure No. : AA 0850131 Rev-02 Method : Visible Solvent
Removable
Dye Penetrant Test : Flaw Check PP-15 Penetrant Time : 20 min.
Cleaner : Flaw Check PC-21 Developer : Flaw Check PD-31 B
S.No. Drg. No. Rev Var BOM No. P.O. Item No. Qty. Remark
01 32510911006 00 00 011 -- NA -- 04 ENCL.&COND.
02 32510911036 00 00 026 -- NA -- 08 ENCL.&COND.

Total Qty. 12 Nos

RESULT :

Tested By : Approved : Witnessed By :


Level : Level : Level :
Date : Date : Date :