Sei sulla pagina 1di 8

2011 - 2014 EMC Corporation. All Rights Reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR
WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY
DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.
EMC
2
, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United State and other countries.
All other trademarks used herein are the property of their respective owners.
For the most up-to-date regulator document for your product line, go to EMC Online Support (https://support.emc.com).
The information in this ESSM is a configuration summary. For more detailed information, refer to https://elabnavigator.emc.com.
EMC Simple Support Matrix
EMC Unified VNX Series
MAY 2014
P/N 300-012-396 REV 36
5/2/14
Table 1 EMC

E-Lab

qualified specific versions or ranges for EMC Unified VNX

Series (page 1 of 2)
Platform Support
Path and Volume Management Cluster
Virtual
Provisioning

Host
Reclamation
f
PowerPath

Native
MPIO/LVM
Symantec / Veritas /
DMP / VxVM / VxDMP
Native Symantec / Veritas /
SFRAC/VxCFS / SF
HA
h
Oracle
RAC
Target Rev Allowed Target Rev Allowed
AIX 5300-09-01-0847
g
5.5 P02 - 5.5 P06, 5.7
5.3 - 5.3
SP1 P01
c
;
5.5 - 5.5 P01
Y
5.1 SP1
5.0 MP3 - 5.1
PowerHA
(HACMP)
5.4 - 7.1
5.0 - 5.0 MP3 10g - 11g
Symantec SF
5.1 SP1
AIX 6100-02-01-0847
g
5.1 SP1- 6.0.1,
6.0.3, 6.1.0
5.0 MP3 - 6.0.3 11g
Symantec SF
5.1 SP1 - 6.0.1,
6.0.3, 6.1.0
AIX 7100-00-02-1041
g
5.3 SP1
P01
c
;
5.5 - 5.5 P01
5.1 SP1 PR1-
6.0.1, 6.0.3,
6.1.0
5.1 SP1 - 6.0.3, 6.1 11g R2
Symantec SF
5.1 SP1 PR1 -
6.0.1, 6.0.3, 6.1.0
(AIX) VIOS 2.1.1 or later
o
5.5 or later
HP-UX 11iv1 (11.11)
g
5.1 SP2
5.1 - 5.1 SP1
(Pvlinks)
d
/
Y
SG 11.16 10g
HP-UX 11iv2 (11.23)
g
5.1 SP2 - 5.2
5.0
SG 11.16 -
11.19
5.0
10g R2 -
11g R1
HP-UX 11iv3 (11.31)
g
Y
5.1 SP1 - 6.0.1,
6.0.3
5.0 - 6.0.1,
6.0.3
SG 11.17 -
11.20
5.0 - 6.0.3
10g R2 -
11g R2
Symantec SF
5.1 SP1 - 6.0.1,
6.03
Linux: AX 2.0 GA - 2.0 SP3
b , n, n
Y
a
Linux: AX 3
b
5.5 - 5.6 and
5.7 SP1 - 5.7 SP1 P01
k
5.3.x
c, k
Y
Linux: AX 4
5.6 and 5.7 SP1
k
Linux: Citrix XenServer 6.x
m
Y
Linux: OL 4 U4 - 4 U7
b , n
5.3.x
c, k
5.0 MP2 -
5.0 MP4
10g -
11g
Linux: OL 5.0, 5.1 - 5. 2
b
5.5
k
5.0 MP3
Linux: OL 5.3 - 5. 5
5.1 SP1 5.0 MP3 - 5.1
Symantec SF
5.1 SP1
Linux: OL 5.6
5.5 - 5.6
k
Linux: OL 5.7- 5.10
5.6
k
6.0
11 g
Symantec SF
6.0
Linux: OL 5.6, 6.0 - 6.1 (UEK) 5.6 P01, 5.7 SP1,
5.7 SP1 P01- P02
k
,
5.7 SP3
Linux: OL 5.7 (UEK) 5.6 P02, 5.7 SP1,
5.7 SP1 P01 - P02
k
,
5.7 SP3
11 g R2
Linux: OL 5.8 - 5.9, 6.2 - 6.4 (UEK) 5.7 SP1,
5.7 SP1 P01 - P02
k
,
5.7 SP3
Linux: RHEL 4.0 U2 - U4
n, b, e
;
4.5 - 4.9
n, b, e
5.3.x
c, k
Y
a 4.1 MP2 -
5.0 MP4
4.1, 5.0
10g -
11g
Linux: RHEL 5.0, 5.1
b
5.5 - 5.6.
5.7 SP1,
5.7 SP1 P01- P02
k
,
5.7 SP3
Y
5.0 MP3 -
5.0 MP4
Y
5.0 MP3 - 5.1
Linux: RHEL 5.2
b
Linux: RHEL 5.3 - 5.4
i
5.1 SP1 5.0 MP3 - 5.1
5.0 MP4 - 5.1 SP1
Symantec SF
5.1 SP1
Linux: RHEL 5.5 - 5.6
i
5.1 SP1 - 6.0.3,
6.1.0
5.0 MP4 - 5.1
Symantec SF
5.1 SP1 - 6.0.3,
6.1.0
Linux: RHEL 5.7
i
5.6, 5.7 SP1,
5.7 SP1 P01- P02
k
,
5.7 SP3
Linux: RHEL 5.8
Linux: RHEL 5.9
Linux: RHEL 5.10 5.7 SP1 P01- P02
k
,
5.7 SP3
5/2/14
Linux: RHEL 6.0
5.6, 5.7 SP1,
5.7 SP1 P01 - P02
k
,
5.7 SP3
Y
5.1 SP1 PR1 &
PR2
Y
5.1 SP1 PR2
11g R2
Symantec SF
5.1 SP1 PR2
Linux: RHEL 6.1, 6.2
5.1 SP1 PR1 -
6.0.3, 6.1.0
5.1 SP1 PR2 - 6.0.3
Symantec SF
5.1 SP1 PR2 -
6.0.3, 6.1.0
Linux: RHEL 6.3, 6.4
5.1 SP1 PR2 &
RP3, 6.0.1 -
6.0.3, 6.1.0
5.1 SP1 RP3, 6.0.1 -
6.0.3
Symantec SF
5.1 SP1 PR2 &
RP3, 6.0.1 -
6.0.3, 6.1.0
Linux: RHEL 6.5
6.0.3 6.0.3
Symantec SF
6.0.3
Linux: SLES 9 SP3 - SLES 9 SP4
5.5
5.3.x
c, k
5.0 - 5.0 MP4 4.1, 5.0 10 g
Linux: SLES 10 - SLES 10 SP3
b
5.5 - 5.7 SP1,
5.7 SP1 P01 - P02
k
5.1 SP1 - 6.0.3
5.0 MP3 - 5.1
5.0 - 5.1,
5.1 SP1- 6.0.3
10g R2 -
11g
Symantec SF
5.1 SP1 - 6.0.3
Linux: SLES 10 SP4
b
5.0 MP4 - 5.1
Linux: SLES 11 - SLES 11 SP2 5.1 SP1 - 6.0.3,
6.0.4, 6.1.0
5.0 MP3 - 5.1,
5.1 SP1- 6.0.3, 6.1
11g R2-
12c R1
Symantec SF
5.1 SP1 - 6.0.3,
6.0.4, 6.1.0
Linux: SLES 11 SP3
5.7 SP2 - 5.7 SP3 6.0.4, 6.1.0 6.0.4 11g R2
Symantec SF
6.0.4, 6.1.0
Microsoft Windows 2003 (x86 and x64) SP2
and R2 SP2
5.5 - 5.7 SP2 5.3 -
5.3 SP1
c
5.1 SP2
5.0 - 5.1 SP1 MSCS 5.0- 5.1
10g R2 -
11g
Symantec SF
5.1 SP2
Microsoft Windows 2008 (x86) SP1 and SP2
MPIO/Y
5.1 - 5.1 SP1
Failover
Cluster
5.0- 5.1 SP2
Microsoft Windows 2008 (x64) SP1 and SP2
i
5.1 SP2 - 6.0.1
5.0 - 6.0.1
Symantec SF
5.1 SP2 - 6.0.1
Microsoft Windows 2008 R2 and R2 SP1
i
5.1 - 6.0.1
Microsoft Windows Server 2012
5.5 SP1 - 5.7 SP2
6.0.2 6.0.2 Symantec SF
6.0.2
Microsoft Windows Server 2012 R2
5.7 SP1 - 5.7 SP2
6.1.0 Symantec SF
6.1.0
OpenVMS Alpha v7.3-2, 8.2, 8.3, 8.4
g
Y Y
OpenVMS Integrity v8.2-1, 8.3, 8.3-1H1, 8.4
g
Solaris 8 SPARC
e
Refer to the Solaris Letters of Support at https://elabnavigator.emc.com, Custom Queries > Extended Support > Specialized Configurations.
Solaris 9 SPARC
5.3 -
5.3 P04
c
MPxIO/Y
5.1 SP1
5.0 - 5.1
SC 3.1 - 3.2 5.0 - 5.1 10g - 11g
Symantec SF
5.1 SP1
Solaris 10 SPARC
5.5 - 5.5 P02
5.1 SP1 - 6.0.3,
6.1.0
SC 3.1 - 3.3
5.0 - 6.0.1, 6.0.3 10g R2 -
11g
Symantec SF
5.1 SP1 - 6.0.3,
6.1.0
Solaris 10 (x86)
5.1 SP1_x64 -
6.0.3_x64
5.0_x64 -
5.1_x64
Symantec SF
5.1 SP1_x64 -
6.0.3_x64
Solaris 11 SPARC
6.0 PR1 - 6.0.1,
6.0.3, 6.1.0
SC 4.0
6.0 PR1 - 6.0.1,
6.03, 6.1
11g R2
Symantec SF
6.0 PR1 - 6.0.1,
6.0.3, 6.1.0
Solaris 11.1 SPARC 5.5 P01 - 5.5 P02 6.0.3, 6.1.0
SC 4.1
6.0.3, 6.1
11g R2,
12c R1
Symantec SF
6.0.3, 6.1.0
Solaris 11 x86 5.5 - 5.5 P02
6.0 PR1_x64 -
6.0.1, 6.0.3_x64
SC 4.0 6.0 PR1 - 6.0.1, 6.03 11g R2
Symantec SF
6.0 PR1_x64 -
6.0.1, 6.0.3_x64
Solaris 11.1 x86
5.5 P01 - 5.5 P02
6.0.3_x64
SC 4.1
6.0.3
11g R2,
12c R1
Symantec SF
6.0.3_x64
VMware ESX/ESXi 4.0 (vSphere)
PP/VE 5.4 - 5.4 SP1
N/A NMP ESX
11g
VMware ESX/ESXi 4.1 (vSphere)
i
PP/VE 5.4 SP2
VxDMP 6.0 -
6.0.1
VMware ESXi 5.0 (vSphere)
i, j
PP/VE 5.7
l
,
5.7 P02
l
, 5.8, 5.9 SP1
VxDMP 6.0.1,
6.1
VMware ESXi 5.1 (vSphere)
i, j
PP/VE 5.7 P02
l
, 5.8,
5.9, 5.9 SP1
VMware ESXi 5.5 (vSphere)
i, j
PP/VE 5.9, 5.9 SP1
VxDMP 6.1
Target Rev = EMC recommended versions for new and existing installations. These versions contain the latest features and provide the highest level of reliability.
Allowed = Older EMC-approved versions that are still functional, or newer/interim versions not yet targeted by EMC. These versions may not contain the latest fixes and features and may require
upgrading to resolve issues or take advantage of newer product features. Versions are suitable for sustaining existing environments but should not be targeted for new installations.
Table 1 EMC

E-Lab

qualified specific versions or ranges for EMC Unified VNX

Series (page 2 of 2)
Platform Support
Path and Volume Management Cluster
Virtual
Provisioning

Host
Reclamation
f
PowerPath

Native
MPIO/LVM
Symantec / Veritas /
DMP / VxVM / VxDMP
Native Symantec / Veritas /
SFRAC/VxCFS / SF
HA
h
Oracle
RAC
Target Rev Allowed Target Rev Allowed
5/2/14
Table 1 Legend, Footnotes, and Components
Legend
Blank = Not supported
Y = Supported
NA = Not applicable
a. MPIO with AX supported at AX 2.0 SP1 and later. MPIO with RHEL supported at RHEL 4.0 U3 and later.
b. 8 Gbs initiator support begins with AX 2.0 SP3, AX 3.0 SP2, OL 4.0 U7, OL 5.2, RHEL 4.7, RHEL 5.2, SLES 10 SP2.
c. These PowerPath versions have reached End-of-Life (EOL). For extended support contact PowerPath Engineering or
https://support.emc.com/products/PowerPath.
d. Pvlinks is an HP-UX alternate pathing solution that does not support load balancing.
e. Refer to the appropriate Letter of Support on the E-Lab Navigator, Extended Support tab, End-of-Life Configurations heading, for information on
end-of-life configurations.
f. Refer to the EMC Virtual Provisioning table (https://elabnavigator.emc.com) for all VP (without host reclamation) qualified configurations.
g. Only server vendor-sourced HBAs are supported.
h. Refer to Symantec Release Notes (www.symantec.com) for supported VxVM versions, which are dependent on the Veritas Cluster version.
i. For EMC XtremSF and XtremCache software operating system and host server support information, refer to the ESM, located at
https://elabnavigator.emc.com, and use VNX, along with the XtremSF model, in the search engine.
j. Refer to the VMware vSphere 5 ESSM, at https://elabnavigator.emc.com, Simple Support Matrix tab, Platform Solutions, for details.
k. Version and kernel specific.
l. Before upgrading to vSphere 5.1, refer to EMC Knowledgebase articles emc302625 and emc305937.
m. All guest operating systems and features that Citrix supports, such as XenMotion, XenHA, and XenDesktop, are supported.
n. This operating system is currently EOL. All corresponding configurations are frozen. It may no longer be publicly supported by the operating
system vendor and will require an extended support contract from the operating system vendor in order for the configuration listed in the ESSM
to be supported by EMC. It is highly recommended the customer upgrade the server to an ESSM-supported configuration or install it as a virtual
machine on an EMC-approved virtualization hypervisor.
o. Consult the Virtualization Hosting Server (Parent) Solutions table in E-Lab Navigator at https://elabnavigator.emc.com for your specific VIOS
version prior to implementation.
Host Servers/ Adapters All Fibre Channel HBAs from Emulex, QLogic (2 Gb/s or greater), and Brocade (8 Gb/s or greater), including vendor rebranded versions. Solaris
requires an RPQ when using any Brocade HBA. All 10 Gb/s Emulex, QLogic, Brocade, Cisco, Broadcom, and Intel CNAs (10GbE NICs that
support FCoE). All 1 Gb/s or 10 Gb/s NICs for iSCSI connectivity, as supported by Server/OS vendor. Any EMC or vendor-supplied OS-
approved driver/firmware/BIOS is allowed. EMC recommends using latest E-Lab Navigator listed driver/firmware/BIOS versions. Adapters must
support link speed compatible with switch (fabric) or array (direct connect). All host systems are supported where the host vendor allows the
host/OS/adapter combination. If systems meet the criteria in this ESSM, no further ELN connectivity validation and no RPQ is required.
Switches All FC SAN switches (2 Gb/s or greater) from EMC Connectrix

, Brocade, Cisco, and QLogic for host and storage connectivity are supported.
Refer to the Switched Fabric Topology Parameters table located on the E-Lab Navigator (ELN) at
https://elabnavigator.emc.com for supported switch fabric interoperability firmware and settings.
Operating environment R30 VNX 5100/5300/5500/5700/7500; EFD Cache, SATA, EFD support added. Minimum FLARE revision 04.30.000.5.xxx.
R30++ VNX 5100/5300/5500/5700/7500; FCoE support added. Minimum FLARE revision 04.30.000.5.5xx.
R31 VNX 5100/5300/5500/5700/7500; Unisphere/Navisphere Manager v1.1; Minimum FLARE revision 05.31.
R32 VNX 5100/5300/5500/5700/7500; Unisphere/Navisphere Manager v1.2; Minimum FLARE revision 05.32.
R33 (only) VNX 5200/5400/5600/5800/7600/8000; Unisphere/Navisphere Manager v1.3; Minimum FLARE revision 05.33.
Table 2 VNX2 Limitations (page 1 of 5)
VNX8000 VNX7600 VNX5800 VNX5600 VNX5400 VNX5200
Storage Pool capacity
Maximum number of storage pools 60 40 40 20 15 15
Maximum number of disks in a storage pool 996 996 746 496 246 121
Maximum number of usable disks for all storage pools 996 996 746 496 246 121
Maximum number of disks that can be added to a pool at a
time
180 120 120 120 80 80
Maximum number of pool LUNs per storage pool 4000 3000 2000 1000 1000 1000
Pool LUN limits
Minimum user capacity 1block 1block 1block 1block 1block 1block
Maximum user capacity 256 TB 256 TB 256 TB 256 TB 256 TB 256 TB
Maximum number of pool LUNs per storage system 4000 3000 2000 1000 1000 1000
SnapView supported configurations
Clones per storage system 2048 2048 2048 1024 256 256
Clones per source LUN 8 8 8 8 8 8
Clones per consistent fracture 64 64 32 32 32 32
Clone groups per storage system 1024 1024 1024 256 128 128
Clone private LUNs
a, b
per storage system (required)
2 2 2 2 2 2
SnapView Snaps
c
per storage system
2048 1024 512 512 256 256
Snapshots per source LUN 8 8 8 8 8 8
SnapView sessions per source LUN 8 8 8 8 8 8
Reserved LUNs
d
per storage system
512 512 256 256 128 128
Source LUNs with Rollback active 300 300 300 300 300 300
SAN Copy Storage system limits
Concurrent Executing Sessions 32 32 16 8 8 8
Destination LUNs per Session 100 100 50 50 50 50
Incremental Source LUNs
e
512 512 256 256 256 256
Defined Incremental Sessions
f
512 512 512 512 512 512
Incremental Sessions per Source LUN 8 8 8 8 8 8
VN X Snapshots Configuration Guidelines
Snapshots per storage system 32000 24000 16000 8000 8000 8000
Snapshots per Primary LUN 256 256 256 256 256 256
Snapshots per consistency group 64 64 64 64 64 64
5/2/14
VNX8000 VNX7600 VNX5800 VNX5600 VNX5400 VNX5200
Consistency Groups 256 256 128 128 128 128
Snapshot Mount Points 4000 3000 2000 1000 1000 1000
Concurrent restore operations 512 512 256 128 128 128
MirrorView
Maximum number of mirrors
256 (MVA)
1024 (MVS)
256 (MVA)
512 (MVS)
256 (MVA)
256 (MVS)
256 (MVA)
128 (MVS)
256 (MVA)
128 (MVS)
128 (MVA)
128 (MVS)
Maximum number of consistency groups
64 64 64 64 64 64
Maximum number of members per consistency group
64 (MVA)
64 (MVS)
64 (MVA)
64 (MVS)
32 (MVA)
32 (MVS)
32 (MVA)
32 (MVS)
32 (MVA)
32 (MVS)
32 (MVA)
32 (MVS)
Block compressed LUN limitations
Maximum number of concurrent compression operations per
Storage Processor(SP)
40 32 20 20 20 20
Maximum number of compressed LUNs involving migration
per storage system
24 24 16 16 16 16
Maximum number of compressed LUNs 4000 3000 2000 1000 1000 1000
Block compression operation limitations
Concurrent compression/decompression operations per SP 40 32 20 20 20 20
Concurrent migration operations per system 24 24 16 16 16 16
Block-level deduplication limitations (VNX for Block)
LUN migrations
8 maximum
Deduplication pass
Started every 12 hours upon the last completed run for that pool
Will only trigger if 64GBs of new/changed data is found
Pass can be paused
Resume causes a check to run shortly after resuming
Deduplications processes per SP
3 maximum
Deduplication run time
4 hour maximum
After 4 hours, deduplication process is paused and other queued process on the SP are allowed to run
If no other processes are queued, deduplication will keep running
Storage systems used for SAN Copy replication
Storage System
Fibre Channel iSCSI
SAN Copy system
Target
g
system
SAN Copy system Target
System
VNX8000, VNX7600, VNX5800, VNX5600
h
, VNX5400, VNX5200
P P P P
VNX7500, VNX5700, VNX5500, VNX5300, VNX5100 P P P P
CX4-960, CX4-480, CX4-240, CX4-120
i
P P P P
CX3-80, CX3-40, CX3-20, CX3-10 P P N/A N/A
CX3-40C, CX3-20C, CX3-10C P P P P
CX700, CX500 P P N/A N/A
CX500i, CX300i N/A N/A X P
CX600, CX400 P P N/A N/A
CX300
X
j
P N/A N/A
CX200 X P N/A N/A
AX100, AX150, X P N/A N/A
AX100i, AX150i N/A N/A X P
AX4-5F P P N/A N/A
AX4-5SCF X P N/A N/A
AX4-5i, AX4-5SCi N/A N/A X P
Operating Environment for File 8.1 Configuration guidelines
Guideline/ Specification Maximum tested value Comment
CIFS guidelines
CIFS TCP connection 64K (default and theoretical
max.), 40K (max. tested)
Param tcp.maxStreams sets the maximum number of TCP connections a Data Mover can have. Maximum
value is 64K, or 65535. TCP connections (streams) are shared by other components and should be changed
in monitored small increments.
With SMB1/SMB2 a TCP connection means single client (machine) connection.
With SMB3 and multi channel, a single client could use several network connections for the same session. It
will depend on the number of available interfaces on the client machine, or for high speed interface like 10Gb
link, it can go up to 4 TCP connections per link.
Share name length 80 characters (Unicode). Unicode: The maximum length for a share name with Unicode enabled is 80 characters.
Number of CIFS shares 40,000 per Data Mover(Max.
tested limit)
Larger number of shares can be created. Maximum tested value is 40K per Data Mover.
Table 2 VNX2 Limitations (page 2 of 5)
5/2/14
Guideline/ Specification Maximum tested value Comment
Number of NetBIOS names/
compnames per Virtual Data
Mover
509 (max) Limited by the number of network interfaces available on the Virtual Data Mover. From a local group
perspective, the number is limited to 509. NetBIOS and compnames must be associated with at least one
unique network interface.
NetBIOS name length 15 NetBIOS names are limited to 15 characters (Microsoft limit) and cannot begin with an@ (at sign) or a - (dash)
character. The name also cannot include white space, tab characters, or the following symbols: / \ : ; , = *
+ | [ ] ? < > . If using compnames, the NetBIOS form of the name is assigned automatically and is derived
from the first 15 characters of the <comp_name>.
Comment (ASCII chars) for
NetBIOS name for server
256 Limited to 256 ASCII characters.
Restricted Characters: You cannot use double quotation ("), semicolon (;), accent (`), and comma (,)
characters within the body of a comment. Attempting to use these special characters results in an error
message. You can only use an exclamation point (!) if it is preceded by a single quotation mark ().
Default Comments: If you do not explicitly add a comment, the system adds a default comment of the
form EMC-SNAS:T<x.x.x.x> where <x.x.x.x> is the version of the NAS software.
Compname length 63 bytes For integration with Windows environment releases later than Windows 2000, the CIFS server computer
name length can be up to 21 characters when UTF-8 (3 bytes char) is used.
Number of domains 10 tested 509 (theoretical max.) The maximum number of Windows domains a Data Mover can be a member of. To
increase the max default value from 32, change parameter cifs.lsarpc.maxDomain. The Parameters Guide for
VNX for File contains more detailed information about this parameter.
Block size negotiated 64 KB
128KB with SMB2
Maximum buffer size that can be negotiated with Microsoft Windows clients. To increase the default value,
change param cifs.W95BufSz, cifs.NTBufSz or cifs.W2KBufSz. The Parameters Guide for VNX for File
contains more detailed information about these parameters.
Note: With SMB2.1, read and write operation supports 1MB buffer (this feature is named large MTU).
Number of simultaneous
requests per CIFS session
(maxMpxCount)
127(SMB1)
512(SMB2)
For SMB1, value is fixed and defines the number of requests a client is able to send to the Data Mover at the
same time (for example, a change notification request). To increase this value, change wsathe maxMpxCount
parameter.
For SMB2 and newer protocol dialect, this notion has been replaced by credit number, which has a max of
512 credit per client but could be adjusted dynamically by the server depending on the load.
The Parameters Guide for VNX for File contains more detailed information about this parameter.
Total number files/directories
opened per Data Mover
500,000 A large number of open files could require high memory usage on the Data Mover and potentially lead to out-
of-memory issues.
Number of Home Directories
supported
20,000(Max possbile limit, not
recommended)
As Configuration file containing Home Directories info is read completely at each user connection,
recommendation would be to not exceed few thousands for easy management.
Number of Windows/UNIX users
connected at the same time
40,000(limited by the number of
TCP connections)
Earlier versions of the VNX server relied on a basic database, nameDB, to maintain Usermapper and secmap
mapping information. DBMS now replaces the basic database. This solves the inode consumption issue and
provides better consistency and recoverability with the support of database transactions. It also provides
better atomicity, isolation, and durability in database management.
Number of users per TCP
connection
64K To decrease the default value, change param cifs.listBlocks (default 255, max 255). The value of this
parameter times 256 = max number of users.
Note: TID/FID/UID shares this parameter and cannot be changed individually for each ID. Use caution when
increasing this value as it could lead to an out-of-memory condition. Refer to the Parameters Guide for VNX
for File for parameter information.
Number of files/directories
opened per CIFS connection in
SMB1
64K To decrease the default value, change param cifs.listBlocks (default 255, max 255). The value of this
parameter times 256 = max number of files/directories opened per CIFS connection.
Note: TID/FID/UID shares this parameter and cannot be changed individually for each ID. Use caution when
increasing this value as it could lead to an out-of-memory condition. Be sure to follow the recommendation for
total number of files/directories opened per Data Mover. Refer to the System Parameters Guide for VNX for
File for parameter information.
Number of files/directories
opened per CIFS connection in
SMB2
127K To decrease the default value, change parameter cifs.smb2.listBlocks (default 511, max 511). The value of
this parameter times 256 = max number of files/directories opened per CIFS connection.
Number of VDMs per Data
Mover
128 The total number of VDMs, file systems, and checkpoints across a whole cabinet cannot exceed 2048.
FileMover
Max connections to secondary
storage per primary (VNX for
File) file system
1024
Number of HTTP threads for
servicing FileMover API requests
per Data Mover
64 Number of threads available for recalling data from secondary storage is half the number of whichever is the
lower of CIFS or NFS threads. 16 (default), can be increased using server_http command, max (tested) is 64.
File system guidelines
Mount point name length 255 bytes (ASCII) The "/" is used when creating the mount point and is equal to one character. If exceeded, Error 4105:
Server_x:path_name: invalid path specified is returned.
File system name length 240 bytes (ASCII)
19 chars display for list option
For nas_fs list, the name of a file system will be truncated if it is more than 19 characters. To display the full
file system name, use the info option with a file system ID (nas_fs -i id=<fsid>).
Filename length 255 bytes (NFS)
255 characters (CIFS)
With Unicode enabled in an NFS environment, the number of characters that can be stored depends on the
client encoding type such as latin-1. For example: With Unicode enabled, a Japanese UTF-8 character may
require three bytes.
With Unicode enabled in a CIFS environment, the maximum number of characters is 255. For filenames
shared between NFS and CIFS, CIFS allows 255 characters. NFS truncates these names when they are
more than 255 bytes in UTF-8, and manages the file successfully.
Table 2 VNX2 Limitations (page 3 of 5)
5/2/14
Guideline/ Specification Maximum tested value Comment
Pathname length 1,024 bytes Note: Make sure the final path length of restored files is less than 1024 bytes. For example, if a file is backed
up which originally had path name of 900 bytes, and it is restoring to a path with 400 bytes, the final path
length would be 1300 bytes and would not be restored.
Directory name length 255 bytes This is a hard limit and is rejected on creation if over the 255 limit.The limit is bytes for UNIX names, Unicode
characters for CIFS.
Subdirectories (per parent
directory)
64,000 This is a hard limit, code will prevent you from creating more than 64,000 directories.
Number of file systems per VNX 4096 This max number includes VDM and checkpoint file systems.
Number of file systems per Data
Mover
2048 The mount operation will fail when the number of file systems reaches 2048 with an error indicating maximum
number of file systems reached. This maximum number includes VDM and checkpoint file systems.
Maximum disk volume size Dependent on RAID group (see
comments)
Unified platforms Running setup_clariion on the VNX7500 platform will provision the storage to use 1
LUN per RAID group which might result in LUNS > 2 TB, depending on drive capacity and number of drives in
the RAID group. On all VNX integrated platforms (VNX5300, VNX5500, VNX5700, VNX7500), the 2 TB LUN
limitation has been lifted--this might or might not result in LUN size larger than 2 TB depending on RAID group
size and drive capacity. For all other unified platforms, setup_clariion will continue to function as in the past,
breaking large RAID groups into LUNS that are < 2 TB in size.
Gateway systems For gateway systems, users might configure LUNs greater than 2 TB up to 16 TB or
max size of the RAID group, whichever is less. This is supported for VG2 and VG8 NAS gateways when
attached to CX3, CX4, VNX, and Symmetrix DMX

-4 and VMAX

backends.
Multi-Path File Systems (MPFS) MPFS supports LUNs greater than 2 TB. Windows 2000 and 32-bit
Windows XP, however, cannot support large LUNs due to a Windows OS limitation. All other MPFS Windows
clients support LUN sizes greater than 2 TB if the 5.0.90.900 patch is applied. Use of these 32-bit Windows
XP clients on VNX7500 systems require request for price quotation (RPQ) approval.
Total storage for a Data Mover
(Fibre Channel Only)
VNX Version 7.0
200 TB VNX5300
256 TB VNX5500, VNX5700,
VNX7500, VG2 & VG8
These total capacity values represent Fibre Channel disk maximum with no ATA drives. Fibre Channel
capacity will change if ATA is used. Notes:
On a per-Data-Mover basis, the total size of all file systems, and the size of all SavVols used by SnapSure
must be less than the total supported capacity. Exceeding these limit can cause out of memory panic.
Refer to the VNX for file capacity limits tables for more information, including mixed disk type
configurations.
File size 16 TB This hard limit is enforced and cannot be exceeded.
Number of directories supported
per file system
Same as number of inodes in file system. Each 8 KB of space = 1 inode.
Number of files per directory 500,000 Exceeding this number will cause performance problems.
Maximum number of files and
directories per VNX file system
256 million (default) This is the total number of files and directories that can be in a single VNX file system. This number can be
increased to 4 billion at file system creation time but should only be done after considering recovery and
restore time and the total storage utilized per file. The actual maximum number in a given file system is
dependent on a number of factors including the size of the file system.
Maximum amount of
deduplicated data supported
256 TB When quotas are enabled with file size policy, the maximum amount of deduplicated data supported is 256
TB. This amount includes other files owned by UID 0 or GID.
All other industry-standard caveats, restrictions, policies, and best practices prevail. This includes, but is not limited to, fsck times (now made faster through multi-threading), backup
and restore times, number of objects per file system, snapshots, file system replication, VDM replication, performance, availability, extend times, and layout policies. Proper planning
and preparation should occur prior to implementing these guidelines.
Naming services guidelines
Number of DNS domains 3 - WebUI
unlimited CLI
Three DNS servers per Data Mover is the limit if using WebUI. There is no limit when using the command line
interface (CLI).
Number of NIS Servers per Data
Mover
10 You can configure up to 10 NIS servers in a single NIS domain on a Data Mover.
NIS record capacity 1004 bytes A Data Mover can read 1004 bytes of data from a NIS record.
Number of DNS servers per DNS
domain
3
NFS guidelines
Number of NFS exports 2,048 per Data Mover tested
Unlimited theoretical max.
You might notice a performance impact when managing a large number of exports using Unisphere.
Number of concurrent NFS
clients
64K with TCP (theoretical)
Unlimited with UDP (theoretical)
Limited by TCP connections.
Netgroup line size 16383 The maximum line length that the Data Mover will accept in the local netgroup file on the Data Mover or the
netgroup map in the NIS domain that the Data Mover is bound to.
Number of UNIX groups
supported
64K 2 billion max value of any GID. The maximum number of GIDs is 64K, but an individual GID can have an ID in
the range of 0- 2147483648.
Networking guidelines
Link aggregation/ether channel 8 ports (ether channel)
12 ports (link aggregation
(LACP)
Ether channel: the number of ports used must be a power of 2 (2, 4, or 8). Link aggregation: any number of
ports can be used. All ports must be the same speed. Mixing different NIC types (that is copper and fibre) is
not recommended.
Number of VLANs supported 4094 IEEE standard.
Number of interfaces per Data
Mover
45 tested Theoretically 509.
Number of FTP connections Theoretical value 64K By default the value is (in theory) 0xFFFF, but it is also limited by the number of TCP streams that can be
opened. To increase the default value, change param tcp.maxStreams (set to 0x00000800 by default). If you
increase it to 64K before you start TCP, you will not be able to increase the number of FTP connections. Refer
to the Parameters Guide for VNX for File for parameter information.
Table 2 VNX2 Limitations (page 4 of 5)
5/2/14
Guideline/ Specification Maximum tested value Comment
Quotas guidelines
Number of tree quotas 8191 Per file system
Max size of tree quotas 256 TB Includes file size and quota tree size.
Max number of unique groups 64K Per file system
Quota path length 1024
Replicator V2 guidelines
Number of replication sessions
per VNX
1365 (NSX) 682
(other platforms)
Max number of replication
sessions per Data Mover
1024 This enforced limit includes all configured file system, VDM, and copy sessions.
Max number of local and remote
file system and VDM replication
sessions per Data Mover
682
Max number of loopback file
system and VDM replication
sessions per Data Mover
341
Guideline/ Specification Maximum tested value Comment
Snapsure guidelines
Number of checkpoints per file
system
96 read-only
16 writeable
Up to 96 read-only checkpoints per file system are supported as well as 16 writeable checkpoints.
On systems with Unicode enabled, a character might require between 1 and 3 bytes, depending on encoding type or character used. For example, a Japanese character typically uses
3 bytes in UTF-8. ASCII characters require 1 byte.
VNX for File 8.1 capacity limits
VNX5200 VNX5400 VNX5600 VNX5800 VNX7600 VNX8000 VG10 VG20
Usable IP storage capacity limit per
blade (all disk types /uses)
k
256 TB 256 TB 256 TB 256 TB 256 TB 256 TB 256 TB 256 TB
Max FS size 16TB 16TB 16TB 16TB 16TB 16 TB 16TB 16TB
Max # FS per DM/Blade
l
2048 2048 2048 2048 2048 2048 2048 2048
Max # FS per cabinet 4096 4096 4096 4096 4096 4096 4096 4096
Max configured replication sessions
per DM/blade for Replicator v2
m
1024 1024 1024 1024 1024 1024 1024 1024
Max # of checkpoints per PFS
n
96 96 96 96 96 96 96 96
Max # of NDMP sessions per DM/
blade
4 4 8 8 8 8 8 8
Memory per DM/blade 6GB 6GB 12GB 12GB 24GB 24GB 6GB 24GB
Table 2 Footnotes:
a. Each clone private LUN must be at least 1 GB.
b. A thin or thick LUN may not be used for a clone private LUN.
c. The limits for snapshots and sessions include SnapView snapshots or SnapView sessions as well as reserved snapshots or reserved sessions used in other applications, such as SAN
Copy (incremental sessions) and MirrorView/Asynchronous.
d. A thin LUN cannot be used in the reserved LUN pool.
e. These limits include MirrorView Asynchronous (MirrorView/A) images and SnapView snapshot source LUNs in addition to the incremental SAN Copy LUNs. The maximum number of source
LUNs assumes one reserved LUN assigned to each source LUN.
f. These limits include MirrorView/A images and SnapView sessions in addition to the incremental SAN Copy sessions.
g. Target implies the storage system can be used as the remote system when using SAN Copy on another storage system.
h. The VNX5400 and VNX5600 may not be supported as target array over Fibre when source array Operating Environment is 04.30.000.5.525 and earlier for CX4 storage systems and
05.32.000.5.207 and earlier for VNX storage systems.
i. The VNX storage systems can support SAN Copy over Fibre Channel or SAN Copy over iSCSI only if the storage systems are configured with I/O ports of that type. Please see the release
notes for VNX Operating Environment version 05.33.000.5.015.
j. The CX300, AX100 and AX150 do not support SAN Copy, but support SAN Copy/E. See the release notes for this related product for details.
k. This is the usable IP storage capacity per blade. For overall platform capacity, consider the type and size of disk drive and the usable Fibre Channel host capacity requirements, RAID group
options and the total number of disks supported.
l. This count includes production file systems, user-defined file system checkpoints, and two checkpoints for each replication session.
m. A maximum of 256 concurrently transferring sessions are supported per DM.
n. PFS (Production File System).
Table 2 VNX2 Limitations (page 5 of 5)