Given data
V=100 volts
P=15 Kw
Poles= 2
Frequency= 50 Hz
Ns= 3000 rpm
Number of phase m= 3
Length= 115 mm
Number of slots s=24
Di= 120.46mm
Ds = 23mm
D=165 mm
CALCULATION
Slots/phase Sm=
24
=8
3
Slots/pole/phase Spp=
24
=4
6
Phasor displacement S =
2
= 15
24
24
WINDING LOCATION
R
R
RR = 1,2,3,4
13,14,15,16
B
B
BB = 5,6,7,8
17,18,19,20
Y
Y
YY = 9,10,11,12
21,22,23,24
STATOR TURNS
Ts =
100
4.44 50 9.563 103 0.955
Ts = 49.32
Ss
Pm
Ss = 24
Qs = 4
Calculation of slot pitch ( to verify the data book value)
D
Ss
120.46
=
24
= 15.768mm
Yss =
296
= 12.33
24
Conductor/slot = 12 cond/slot
Cross check with 6Ts
296
= 49.33
6
15 103
3 100 0.9 0.9
2 assumed as 90%
Stator current per phase = 61.72 A
Js
61.72
= 12.344m 2
5
we know
d2
as =
4
12.344=
d2
4
d2 =
4 12.344
d 2 =15.716