Sei sulla pagina 1di 1

ARGUMENTOS

Tp :

0.6

4
1.2

S:

Rx :
8

Z:

0.4

hn :
T:
C:

2.9 m.
0.06
45
2.5

217.7325

C/R

0.313

V:

217.7

U:

8
1.5

DATOS DE LA ESTRUCTURA

PCM total :
788 Ton
PCV total:
359 Ton
%
50%
Peso de la Estructura:

FALSE
Sistema Irregular?

CT :
967.7 Ton

Cortante en la Base

V/P :

0.2250

V:

OK!

Distribucion de la Fuerza Sismica en Altura

Fa :

0.0

32.66

ok!

Nivel
(N)

Pi
(ton)

Hi
(m.)

Pi.Hi

Pi.Hi
Pi.Hi

Fx:
(ton)

1
2
3
4
5
6
7
8
9
10

182.1
154.18
154.17
154.17
154.18
168.83
0
0
0
0

2.88
5.76
8.64
11.52
14.4
17.28
20.16
23.04
25.92
28.8

0.054
0.092
0.138
0.184
0.230
0.302
0.000
0.000
0.000
0.000

11.8
20.0
30.0
40.0
50.1
65.8
0.0
0.0
0.0
0.0
217.7

524.45
888.08
1332
1776
2220.2
2917.4
0
0
0
0
Pi.Hi 9658.2

10

0.00

0.00

0.00

0.00

65.77
50.05
40.04
30.03
20.02
11.82

5
4
3
2
1

Potrebbero piacerti anche