Sei sulla pagina 1di 1

: HBL-150.

IES
Candela Plot
Luminaire Properties

180

0.0
22.5
45.0
67.5
90.0
112.5
135.0
157.5
180.0

6668

135

Number of Lamps:
Lumens Per Lamp:
Input Watts:
Distribution:
Symmetry:
Photometric Type:
Luminous Shape:
Units:
Luminous Dimensions:
0-180 Axis:
90-270 Axis:
Height:

5001

1
21380
174
Direct
Bilateral 0-180
Type C
Rectangle
Feet

3334

1667

90

1667

3334

5001

4.17
1.40
0.00

45

6668

Zonal Lumen Summary


Zone

Lumens

% Lamp

% Fixture

0-30

5758

27

27

0-40

9520

45

45

0-60

17271

81

81

0-90

21324

100

100

90-120

90-150

90-180

0-180

21326

100

100

Coefficients of Utilization
pfc= 0.20
pcc->

0.80

0.70

0.50

0.30

0.10

0.00

pw-> 0.70 0.50 0.30 0.10 0.70 0.50 0.30 0.10 0.50 0.30 0.10 0.50 0.30 0.10 0.00 0.00 0.00

0.00

RCR
0

119

119

119

109

105

99

91

90

83

5
6

119

116

116

101

97

106

102

99

95

98

95

92

94

92

90

86

86

86

85

85

79

97

89

83

78

86

81

76

83

78

75

72

72

72

71

80

72

66

88

79

71

65

76

69

64

73

67

63

60

60

60

60

71

62

56

80

70

61

55

67

60

54

65

59

54

51

51

51

51

76

63

54

48

74

62

54

47

60

53

47

58

51

46

44

44

44

44

70

57

48

42

68

56

47

41

54

47

41

52

46

41

38

38

38

38

65

51

43

37

63

51

42

36

49

42

36

48

41

36

34

34

34

34

60

47

38

32

59

46

38

32

45

37

32

44

37

32

30

30

30

30

56

43

35

29

55

42

34

29

41

34

29

40

34

29

27

27

27

27

10

53

40

32

26

51

39

31

26

38

31

26

37

31

26

24

24

24

24

Designer Project
Prepared For:
Prepared By:

116

116

111

111

111

106

106

106

102

102

102

100

Produced: 18-mar-2014

[Prepared for]
Ingenierias

Output generated by Lumen Designer. Copyright 2003-2006 .


Note: Calculations performed based on IESNA and/or CIE standards. Measured values may vary due to actual field conditions, calculation tolerances and measurement techniques.